Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 38
Filtrar
1.
Eur J Cardiothorac Surg ; 62(2)2022 07 11.
Artigo em Inglês | MEDLINE | ID: mdl-35583290

RESUMO

OBJECTIVES: Despite growing evidence that aortic valve repair improves long-term patient outcomes and quality of life, aortic valves are mostly replaced. We evaluate the effect of aortic valve repair versus replacement in patients with dystrophic aortic root aneurysm up to 4 years. METHODS: The multicentric CAVIAAR (Conservation Aortique Valvulaire dans les Insuffisances Aortiques et les Anévrismes de la Racine aortique) prospective cohort study enrolled 261 patients: 130 underwent standardized aortic valve repair (REPAIR) consisting of remodelling root repair with expansible aortic ring annuloplasty, and 131 received mechanical composite valve and graft replacement (REPLACE). Primary outcome was a composite criterion of mortality, reoperation, thromboembolic or major bleeding events, endocarditis or operating site infections, pacemaker implantation and heart failure, analysed with propensity score-weighted Cox model analysis. Secondary outcomes included major adverse valve-related events and components of primary outcome. RESULTS: The mean age was 56.1 years, and valve was bicuspid in 115 patients (44.7%). Up to 4 years, REPAIR did not significantly differ from REPLACE in terms of primary outcome [Hazard Ratio (HR) 0.66 (0.39; 1.12)] but showed significantly less valve-related deaths (HR 0.09 [0.02; 0.34]) and major bleeding events (HR 0.37 [0.16; 0.85]) without an increased risk of valve-related reoperation (HR 2.10 [0.64; 6.96]). When accounting for the occurrence of multiple events in a single patient, the REPAIR group had half the occurrence of major adverse valve-related events (HR 0.51 [0.31; 0.86]). CONCLUSIONS: Although the primary outcome did not significantly differ between the REPAIR and REPLACE groups, the trend is in favour of REPAIR by a significant reduction of valve-related deaths and major bleeding events. Long-term follow-up beyond 4 years is needed to confirm these findings.


Assuntos
Aneurisma Aórtico , Insuficiência da Valva Aórtica , Anuloplastia da Valva Cardíaca , Implante de Prótese de Valva Cardíaca , Humanos , Pessoa de Meia-Idade , Valva Aórtica/cirurgia , Anuloplastia da Valva Cardíaca/efeitos adversos , Aneurisma Aórtico/cirurgia , Estudos Prospectivos , Qualidade de Vida , Resultado do Tratamento , Reoperação/efeitos adversos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Estudos Retrospectivos
2.
Stem Cell Rev Rep ; 17(6): 2332-2337, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34622384

RESUMO

The Aeson® total artificial heart (A-TAH) has been developed as a total heart replacement for patients at risk of death from biventricular failure. We previously described endothelialization of the hybrid membrane inside A-TAH probably at the origin of acquired hemocompatibility. We aimed to quantify vasculogenic stem cells in peripheral blood of patients with long-term A-TAH implantation. Four male adult patients were included in this study. Peripheral blood mononuclear cells were collected before A-TAH implantation (T0) and after implantation at one month (T1), between two and five months (T2), and then between six and twelve months (T3). Supervised analysis of flow cytometry data confirmed the presence of the previously identified Lin-CD133+CD45- and Lin-CD34+ with different CD45 level intensities. Lin-CD133+CD45-, Lin-CD34+CD45- and Lin-CD34+CD45+ were not modulated after A-TAH implantation. However, we demonstrated a significant mobilization of Lin-CD34+CD45dim (p = 0.01) one month after A-TAH implantation regardless of the expression of CD133 or c-Kit. We then visualized data for the resulting clusters on a uniform manifold approximation and projection (UMAP) plot showing all single cells of the live Lin- and CD34+ events selected from down sampled files concatenated at T0 and T1. The three clusters upregulated at T1 are CD45dim clusters, confirming our results. In conclusion, using a flow cytometry approach, we demonstrated in A-TAH-transplanted patients a significant mobilization of Lin-CD34+CD45dim in peripheral blood one month after A-TAH implantation. Using a flow cytometry approach, we demonstrated in A-TAH transplanted patients a significant mobilization of Lin-CD34+CD45dim in peripheral blood one month after A-TAH implantation. This cell population could be at the origin of newly formed endothelial cells on top of hybrid membrane in Carmat bioprosthetic total artificial heart.


Assuntos
Células Endoteliais , Coração Artificial , Adulto , Antígenos CD34 , Humanos , Leucócitos Mononucleares , Masculino , Células-Tronco
3.
Interact Cardiovasc Thorac Surg ; 33(6): 978-985, 2021 11 22.
Artigo em Inglês | MEDLINE | ID: mdl-34313320

RESUMO

OBJECTIVES: Right ventricular failure after left ventricular assist device (LVAD) insertion is associated with significant mortality and morbidity. Mechanical support options include right ventricular assist devices, venoarterial extracorporeal membrane oxygenation (ECMO) and venopulmonary artery ECMO, the latter often involving central cannulation. We sought to evaluate the feasibility and early outcomes of a truly percutaneous venopulmonary artery (pVPA) ECMO strategy, with the potential advantage of bedside removal once weaned. METHODS: Data from a single tertiary centre were reviewed retrospectively from January 2014 to January 2019. During this time, 54 patients underwent LVAD insertion, with 19 requiring mechanical support for right ventricular failure. Among them, 10 patients received pVPA ECMO. Implantation of the pVPA ECMO was performed under transoesophageal echocardiography and fluoroscopy guidance, with an inflow cannula placed in the right atrium via the right femoral vein and an outflow cannula placed in the left pulmonary artery (PA) via the right internal jugular vein. RESULTS: Cannula insertion was 100% successful with no need for repositioning. Eight patients (80%) were able to be successfully weaned (at the bedside); 6 were discharged from the hospital and there were no cases of early sepsis, mediastinitis or thromboembolism. At follow-up, 5 patients had received transplants (50%), with 1 on LVAD support as destination therapy (10%). Survival was 60 ± 15% and 50 ± 16% at 6 and 12 months, respectively. CONCLUSIONS: pVPA ECMO is 100% technically feasible and is an efficient method for temporary right ventricular support after LVAD insertion with the advantage of simple bedside removal and avoidance of a PA graft remnant in the chest cavity.


Assuntos
Oxigenação por Membrana Extracorpórea , Insuficiência Cardíaca , Coração Auxiliar , Oxigenação por Membrana Extracorpórea/métodos , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/terapia , Coração Auxiliar/efeitos adversos , Humanos , Artéria Pulmonar/diagnóstico por imagem , Estudos Retrospectivos
4.
J Clin Monit Comput ; 34(3): 559-566, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-31278543

RESUMO

Little is known about the evolution of diaphragmatic function in the early post-cardiac surgery period. The main purpose of this work is to describe its evolution using ultrasound measurements of muscular excursion and thickening fraction (TF). Single-center prospective study of 79 consecutive uncomplicated elective cardiac surgery patients, using motion-mode during quiet unassisted breathing. Excursion and TF were measured sequentially for each patient [pre-operative (D1), 1 day (D2) and 5 days (D3) after surgery]. Pre-operative median for right and left hemidiaphragmatic excursions were 1.8 (IQR 1.6 to 2.1) cm and 1.7 (1.4 to 2.0) cm, respectively. Pre-operative median right and left thickening fractions were 28 (19 to 36) % and 33 (22 to 51) %, respectively. At D2, there was a reduction in both excursion (right: 1.5 (1.1 to 1.8) cm, p < 0.001, left: 1.5 (1.1 to 1.8), p = 0.003) and thickening fractions (right: 20 (15 to 34) %, p = 0.021, left: 24 (17 to 39) %, p = 0.002), followed by a return to pre-operative values at D3. A positive moderate correlation was found between excursion and thickening fraction (Spearman's rho 0.518 for right and 0.548 for left hemidiaphragm, p < 0.001). Interobserver reliability yielded a bias below 0.1 cm with limits of agreement (LOA) of ± 0.3 cm for excursion and - 2% with LOA of ± 21% for thickening fractions. After cardiac surgery, the evolution of diaphragmatic function is characterized by a transient impairment followed by a quick recovery. Although ultrasound diaphragmatic excursion and thickening fraction are correlated, excursion seems to be a more feasible and reproducible method in this population.


Assuntos
Diafragma/fisiologia , Monitorização Fisiológica/métodos , Respiração , Ultrassonografia , Idoso , Procedimentos Cirúrgicos Cardíacos , Estudos de Coortes , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Movimento (Física) , Período Pré-Operatório , Estudos Prospectivos , Reprodutibilidade dos Testes , Centros de Atenção Terciária , Fatores de Tempo , Interface Usuário-Computador
5.
Intensive Care Med ; 45(10): 1401-1412, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-31576435

RESUMO

PURPOSE: To evaluate whether a perioperative open-lung ventilation strategy prevents postoperative pulmonary complications after elective on-pump cardiac surgery. METHODS: In a pragmatic, randomized, multicenter, controlled trial, we assigned patients planned for on-pump cardiac surgery to either a conventional ventilation strategy with no ventilation during cardiopulmonary bypass (CPB) and lower perioperative positive end-expiratory pressure (PEEP) levels (2 cm H2O) or an open-lung ventilation strategy that included maintaining ventilation during CPB along with perioperative recruitment maneuvers and higher PEEP levels (8 cm H2O). All study patients were ventilated with low-tidal volumes before and after CPB (6 to 8 ml/kg of predicted body weight). The primary end point was a composite of pulmonary complications occurring within the first 7 postoperative days. RESULTS: Among 493 randomized patients, 488 completed the study (mean age, 65.7 years; 360 (73.7%) men; 230 (47.1%) underwent isolated valve surgery). Postoperative pulmonary complications occurred in 133 of 243 patients (54.7%) assigned to open-lung ventilation and in 145 of 245 patients (59.2%) assigned to conventional ventilation (p = 0.32). Open-lung ventilation did not significantly reduce the use of high-flow nasal oxygenotherapy (8.6% vs 9.4%; p = 0.77), non-invasive ventilation (13.2% vs 15.5%; p = 0.46) or new invasive mechanical ventilation (0.8% vs 2.4%, p = 0.28). Mean alive ICU-free days at postoperative day 7 was 4.4 ± 1.3 days in the open-lung group vs 4.3 ± 1.3 days in the conventional group (mean difference, 0.1 ± 0.1 day, p = 0.51). Extra-pulmonary complications and adverse events did not significantly differ between groups. CONCLUSIONS: A perioperative open-lung ventilation including ventilation during CPB does not reduce the incidence of postoperative pulmonary complications as compared with usual care. This finding does not support the use of such a strategy in patients undergoing on-pump cardiac surgery. TRIAL REGISTRATION: Clinicaltrials.gov Identifier: NCT02866578. https://clinicaltrials.gov/ct2/show/NCT02866578.


Assuntos
Procedimentos Cirúrgicos Cardíacos/normas , Complicações Pós-Operatórias/etiologia , Respiração Artificial/normas , Resultado do Tratamento , Idoso , Procedimentos Cirúrgicos Cardíacos/métodos , Procedimentos Cirúrgicos Cardíacos/estatística & dados numéricos , Oxigenação por Membrana Extracorpórea/métodos , Feminino , França/epidemiologia , Humanos , Pulmão/fisiopatologia , Masculino , Pessoa de Meia-Idade , Respiração com Pressão Positiva/métodos , Respiração com Pressão Positiva/normas , Respiração com Pressão Positiva/estatística & dados numéricos , Complicações Pós-Operatórias/epidemiologia , Respiração Artificial/métodos , Respiração Artificial/estatística & dados numéricos , Volume de Ventilação Pulmonar/fisiologia
6.
Arch Cardiovasc Dis ; 112(5): 305-313, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-30772270

RESUMO

BACKGROUND: Aortopathy is common in patients with bicuspid aortic valve (BAV). AIM: To evaluate the fate of unreplaced Valsalva sinuses in patients with BAV, 10 years after aortic valve replacement (AVR) with or without replacement of the ascending aorta (RAA). METHODS: We retrospectively reviewed all surgical patients with BAV who were operated on between January 2005 and December 2007. Patients who underwent AVR with or without RAA were included. Surgical data were entered prospectively. Ten-year clinical and echocardiographic follow-up data as well as survival data were collected by contacting the patients and their personal cardiologists, and by consulting the French national mortality registry. Overall, 25% of the patients had computed tomography angiographic assessment of the aortic root at follow-up. RESULTS: A total of 133 patients with BAV were operated on within the selected period. Thirty-two patients did not meet the inclusion criteria, and had primary Valsalva sinus surgery. Twenty-four patients underwent AVR with RAA and 77 patients had isolated AVR; all of these 101 patients were included in the study. The median follow-up was 9 years (up to 12 years). During follow-up, eight patients (7.9%) underwent late reoperation; two of them (2.0%) required root surgery. Ten-year freedom from reoperation was 86.2±4.7%. Ten-year freedom from dilatation of the Valsalva sinuses (>45mm) was 86.6±5.2%. Ten-year cumulative survival was 83.5±4%. CONCLUSIONS: Ascending aorta and Valsalva sinuses seem to have different fates after AVR in BAV disease. When the Valsalva sinuses are not dilated at the initial surgery, the risk of secondary dilatation at 10 years is low. Preservation of the sinuses is therefore justified in patients with BAV with a non-dilated root. In BAV with isolated aortic insufficiency, a more aggressive approach may be justified, especially in young patients.


Assuntos
Valva Aórtica/anormalidades , Doenças das Valvas Cardíacas/cirurgia , Implante de Prótese de Valva Cardíaca , Seio Aórtico , Adulto , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Valva Aórtica/cirurgia , Aortografia/métodos , Doença da Válvula Aórtica Bicúspide , Angiografia por Tomografia Computadorizada , Dilatação Patológica , Feminino , Seguimentos , Doenças das Valvas Cardíacas/diagnóstico por imagem , Doenças das Valvas Cardíacas/fisiopatologia , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/instrumentação , Humanos , Masculino , Pessoa de Meia-Idade , Intervalo Livre de Progressão , Reoperação , Estudos Retrospectivos , Fatores de Risco , Seio Aórtico/diagnóstico por imagem , Seio Aórtico/fisiopatologia , Seio Aórtico/cirurgia , Fatores de Tempo , Remodelação Vascular
7.
Intensive Care Med ; 45(1): 33-43, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-30617461

RESUMO

PURPOSE: Postoperative pain after cardiac surgery, exacerbated by cough and sternal mobilization, limits clearance of bronchopulmonary secretions and may predispose to postoperative pneumonia. In this study, we tested the ability of local anesthetic continuous wound infusion to prevent pneumonia after cardiac surgery with sternotomy and cardiopulmonary bypass (CPB) owing to better analgesia and bronchopulmonary drainage. METHODS: In this randomized, double-blind, placebo-controlled trial conducted in five academic centers, patients undergoing cardiac surgery with sternotomy and CPB were enrolled from February 2012 until November 2014, and were followed over 30 days. Patients were assigned to a 48-h infusion (10 ml h-1) of L-bupivacaine (12.5 mg h-1) or placebo (saline) via a pre-sternal multiperforated catheter. Anesthesia and analgesia protocols were standardized. The primary end point was the incidence of pneumonia during the study period, i.e., until hospital discharge or 30 days. We hypothesized a 30% reduction in the incidence of pneumonia. RESULTS: Among 1493 randomized patients, 1439 completed the trial. Pneumonia occurred in 36/746 patients (4.9%) in the L-bupivacaine group and in 42/739 patients (5.7%) in the placebo group (absolute risk difference taking into account center and baseline risk of postoperative pneumonia, - 1.3% [95% CI - 3.4; 0.8] P = 0.22). In the predefined subgroup of patients at high risk, L-bupivacaine decreased the incidence of pneumonia (absolute risk difference, - 5.6% [95% CI - 10.0; - 1.1], P = 0.01). CONCLUSIONS: After cardiac surgery with sternotomy, continuous wound infusion of L-bupivacaine failed to decrease the incidence of pneumonia. These findings do not support the use of local anesthetic continuous wound infusion in this indication. Further study should investigate its effect in high-risk patients. TRIAL REGISTRATION: EudraCT Number: 2011-003292-10; Clinicaltrials.gov Identifier: NCT01648777.


Assuntos
Anestésicos Locais/administração & dosagem , Bombas de Infusão/normas , Esternotomia/efeitos adversos , Centros Médicos Acadêmicos/organização & administração , Centros Médicos Acadêmicos/estatística & dados numéricos , Idoso , Idoso de 80 Anos ou mais , Anestésicos Locais/uso terapêutico , Bupivacaína/administração & dosagem , Bupivacaína/uso terapêutico , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Procedimentos Cirúrgicos Cardíacos/métodos , Procedimentos Cirúrgicos Cardíacos/normas , Método Duplo-Cego , Feminino , França/epidemiologia , Humanos , Bombas de Infusão/estatística & dados numéricos , Bombas de Infusão/tendências , Masculino , Pessoa de Meia-Idade , Placebos , Pneumonia/tratamento farmacológico , Pneumonia/epidemiologia , Pneumonia/prevenção & controle , Complicações Pós-Operatórias/tratamento farmacológico , Complicações Pós-Operatórias/epidemiologia , Esternotomia/métodos , Esternotomia/normas , Esternotomia/estatística & dados numéricos
9.
Cardiovasc Eng Technol ; 10(1): 22-31, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30288692

RESUMO

OBJECTIVES: To analyze the volumetric evolution of abdominal aortic aneurysms after endovascular sealing (EVAS) with the Nellix™ device during follow-up. METHODS: Patients who underwent elective EVAS in our institution in 2014 and 2015 were retrospectively reviewed. Preoperative, postoperative and 1-year scans were processed. A custom software was conceived to assess semi-automated measurements of the aneurysm sac and the endograft sizes including volume, maximum diameter, sectional area and perimeter. Thrombus volume, aneurysm length, mean distance between the stents inside the polymer-filled sacs and endograft migration were also estimated. Manual maximum diameters were measured for comparison. Inter and intra-observer variability of the proposed semi-automated method was evaluated. RESULTS: Pre-EVAS, post-EVAS and last follow-up scans of 12 patients were finally analyzed during a mean follow-up of 17 ± 5 months. No endograft migration or endoleak were detected. During follow-up, aneurysm volume and perimeter slightly increased compared to post-EVAS scans (+ 1 and + 5%, respectively, p < 0.05). A systematic 6% enlargement of the endobag volume was also observed (range 1-15 mL, p < 0.001). Endobag maximum diameter, area and perimeter increased 4, 8, and 8%, respectively (all p < 0.01). Mean plane-by-plane distance between stents increased 4% (p < 0.05). Mean thrombus volume did not change during follow-up, although a high variability was observed. Aneurysm and thrombus volume changes were highly correlated (r = 0.93, p < 0.001). No associations were observed between aneurysm and endobag volume changes. Intra- and inter-observer variability was below 1.7 and 2.4% for diameter and volume measurements, respectively. The automated measurements of post-EVAS aneurysm diameter and volume were higher than preoperative (p < 0.05). Maximum diameters measured manually did not differ between scans. CONCLUSION: Small aneurysm volume enlargement detected during a mid-term follow-up was associated with thrombus size change, whereas systematic endograft expansion resulted independent from the aortic growth. Volumetric measurements using a semi-automated method could quantify small changes in aneurysm, endograft and thrombus sizes not detected by manually defined maximal diameters.


Assuntos
Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Aortografia/métodos , Implante de Prótese Vascular/instrumentação , Angiografia por Tomografia Computadorizada , Procedimentos Endovasculares/instrumentação , Tomografia Computadorizada Multidetectores , Idoso , Idoso de 80 Anos ou mais , Implante de Prótese Vascular/efeitos adversos , Procedimentos Endovasculares/efeitos adversos , Feminino , Humanos , Masculino , Variações Dependentes do Observador , Valor Preditivo dos Testes , Interpretação de Imagem Radiográfica Assistida por Computador , Reprodutibilidade dos Testes , Estudos Retrospectivos , Trombose/diagnóstico por imagem , Fatores de Tempo , Resultado do Tratamento
10.
Eur J Cardiothorac Surg ; 53(6): 1251-1257, 2018 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-29293911

RESUMO

OBJECTIVES: Surgical mortality and long-term outcomes are important considerations when determining strategies for multiple reoperations on the aortic valve (AV). With the rise of percutaneous valve-in-valve, we sought to evaluate the current outcomes of conventional surgery for AV reoperation, focusing first on the effect of the number of previous AV interventions with a subsequent analysis of the risk factors for adverse outcomes. METHODS: From January 2007 to December 2016, 316 consecutive patients underwent an open redo operation (replacement) on their AV at a single centre. It was the first AV reintervention in 263 patients (Group 1), second in 42 patients (Group 2) and third or more in 11 patients (Group 3). RESULTS: There were 230 men and 86 women, with a median age of 58 (Q1-Q3: 46-70) years. Structural valve deterioration (SVD) of the bioprosthesis (n = 136, 44%), endocarditis (n = 57, 18%) and prosthetic valve dehiscence (n = 41, 13%) were the most common reasons for reintervention. Overall, in-hospital mortality was 7.3%: 7.2% in Group 1, 4.76% in Group 2 and 18.2% in Group 3 (P = 0.233) and ranged from 3.7% for SVD to 14.0% when endocarditis was the reason for reintervention. Higher preoperative New York Heart Association (NYHA) class (III/IV) [odds ratio (OR) 15.9, P = 0.011], injury during re-entry (OR 16.9, P = 0.015), endocarditis (OR 3.7, P = 0.038) and concomitant mitral valve replacement (OR 5.6, P = 0.006) were independent risk factors for in-hospital mortality. Survival at 8 years was 79.0 ± 3.0% for the entire cohort and 88.4 ± 3.2% for re-replacement after SVD. CONCLUSIONS: Multiple AV reoperations carry an acceptable risk of early postoperative mortality, particularly for isolated valve replacements of SVD.


Assuntos
Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca , Reoperação , Idoso , Bioprótese , Feminino , Doenças das Valvas Cardíacas/cirurgia , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Implante de Prótese de Valva Cardíaca/mortalidade , Implante de Prótese de Valva Cardíaca/estatística & dados numéricos , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias , Reoperação/efeitos adversos , Reoperação/mortalidade , Reoperação/estatística & dados numéricos , Estudos Retrospectivos , Resultado do Tratamento
11.
Eur J Cardiothorac Surg ; 53(1): 170-177, 2018 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-28950304

RESUMO

OBJECTIVES: Heart transplantation (HT) and ventricular assist devices (VAD) for the management of end-stage heart failure have not been directly compared. We compare the outcomes and use of resources with these 2 strategies in 2 European countries with different allocation systems. METHODS: We studied 83 patients managed by VAD as the first option in Bad Oeynhausen, Germany (Group I) and 141 managed with either HT or medical therapy, as the first option, in Paris, France (Group II). The primary end-point was 2-year survival. Kaplan-Meier analyses were performed after the application of propensity score weights to mitigate the effects of non-random group assignment. The secondary end-points were resource utilization and costs. Subgroup analyses were performed for patients undergoing HT and patients treated with inotropes at the enrolment time. RESULTS: The Group I patients were more severely ill and haemodynamically compromised, and 28% subsequently underwent HT vs 55% primary HT in Group II, P < 0.001. The adjusted probability of survival was 44% in Group I vs 70% in Group II, P <0.0001. The mean cumulated 2-year costs were €281 361 ± 156 223 in Group I and €47 638 ± 35 061 in Group II, P < 0.0001. Among patients who underwent HT, the adjusted probability of survival in Group I (n = 23) versus Group II (n = 78) was 76% versus 68%, respectively (0.09), though it differed in the inotrope-treated subgroups (77% in Group I vs 67% in Group II, P = 0.04). CONCLUSIONS: HT should remain the first option for end-stage heart failure patients, associated with improved outcomes and better cost-effectiveness profile. VAD devices represent an option when transplant is not possible or when patient presentation is not optimal.


Assuntos
Insuficiência Cardíaca/cirurgia , Transplante de Coração , Coração Auxiliar , Adolescente , Adulto , Idoso , Análise Custo-Benefício , Feminino , Seguimentos , França , Alemanha , Custos de Cuidados de Saúde/estatística & dados numéricos , Insuficiência Cardíaca/economia , Insuficiência Cardíaca/mortalidade , Transplante de Coração/economia , Transplante de Coração/mortalidade , Coração Auxiliar/economia , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Pontuação de Propensão , Resultado do Tratamento , Adulto Jovem
12.
Eur Heart J ; 39(20): 1794-1798, 2018 05 21.
Artigo em Inglês | MEDLINE | ID: mdl-29244074

RESUMO

Aims: Heart failure (HF) is accompanied by major neuroendocrine changes including the activation of the natriuretic peptide (NP) pathway. Using the unique model of patients undergoing implantation of the CARMAT total artificial heart and investigating regional differences in soluble neprilysin (sNEP) in patients with reduced or preserved systolic function, we studied the regulation of the NP pathway in HF. Methods and results: Venous blood samples from two patients undergoing replacement of the failing ventricles with a total artificial heart were collected before implantation and weekly thereafter until post-operative week 6. The ventricular removal was associated with an immediate drop in circulating NPs, a nearly total disappearance of circulating glycosylated proBNP and furin activity and a marked decrease in sNEP. From post-operative week 1 onwards, NP concentrations remained overall unchanged. In contrast, partial recoveries in glycosylated proBNP, furin activity, and sNEP were observed. Furthermore, while in patients with preserved systolic function (n = 6), sNEP concentrations in the coronary sinus and systemic vessels were similar (all P > 0.05), in patients with reduced left-ventricular systolic function, sNEP concentration, and activity were ∼three-fold higher in coronary sinus compared to systemic vessels (n = 21, all P < 0.0001), while the trans-pulmonary gradient was neutral (n = 5, P = 1.0). Conclusion: The heart plays a pivotal role as a regulator of the endocrine response in systolic dysfunction, not only by directly releasing NPs but also by contributing to circulating sNEP, which in turn determines the bioavailability of other numerous vasoactive peptides.


Assuntos
Insuficiência Cardíaca/fisiopatologia , Coração/fisiopatologia , Peptídeos Natriuréticos/fisiologia , Neprilisina/fisiologia , Idoso , Biomarcadores/sangue , Feminino , Insuficiência Cardíaca/sangue , Insuficiência Cardíaca/cirurgia , Coração Artificial , Humanos , Masculino , Pessoa de Meia-Idade , Peptídeo Natriurético Encefálico/sangue , Neprilisina/sangue , Neprilisina/genética , Fragmentos de Peptídeos/sangue , Período Pós-Operatório , RNA Mensageiro/genética , Transdução de Sinais/fisiologia , Sístole/fisiologia
13.
J Cardiothorac Vasc Anesth ; 31(5): 1595-1602, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-28648774

RESUMO

OBJECTIVES: To determine hemostasis perturbations, including von Willebrand factor (VWF) multimers, after implantation of a new bioprosthetic and pulsatile total artificial heart (TAH). DESIGN: Preclinical study SETTING: Single-center biosurgical research laboratory. PARTICIPANTS: Female Charolais calves, 2-to-6 months old, weighing 102-to-122 kg. INTERVENTIONS: Surgical implantation of TAH through a mid-sternotomy approach. MEASUREMENTS AND MAIN RESULTS: Four of 12 calves had a support duration of several days (4, 4, 8, and 10 days), allowing for the exploration of early steps of hemostasis parameters, including prothrombin time; coagulation factor levels (II, V, VII+X, and fibrinogen); and platelet count. Multimeric analysis of VWF was performed to detect a potential loss of high-molecular weight (HMW) multimers, as previously described for continuous flow rotary blood pumps. Despite the absence of anticoagulant treatment administered in the postoperative phase, no signs of coagulation activation were detected. Indeed, after an immediate postsurgery decrease of prothrombin time, platelet count, and coagulation factor levels, most parameters returned to baseline values. HMW multimers of VWF remained stable either after initiation or during days of support. CONCLUSIONS: Coagulation parameters and platelet count recovery in the postoperative phase of the Carmat TAH (Camat SA, Velizy Villacoublay Cedex, France) implantation in calves, in the absence of anticoagulant treatment and associated with the absence of decrease in HMW multimers of VWF, is in line with early hemocompatibility that is currently being validated in human clinical studies.


Assuntos
Bioprótese/tendências , Transplante de Coração/tendências , Coração Artificial/tendências , Hemostasia/fisiologia , Doenças de von Willebrand , Fator de von Willebrand/metabolismo , Animais , Bioprótese/efeitos adversos , Bovinos , Feminino , Transplante de Coração/efeitos adversos , Transplante de Coração/instrumentação , Coração Artificial/efeitos adversos , Recuperação de Função Fisiológica/fisiologia , Doenças de von Willebrand/sangue , Doenças de von Willebrand/diagnóstico
14.
Lancet ; 386(10003): 1556-63, 2015 Oct 17.
Artigo em Inglês | MEDLINE | ID: mdl-26231456

RESUMO

BACKGROUND: The development of artificial hearts in patients with end-stage heart disease have been confronted with the major issues of thromboembolism or haemorrhage. Since valvular bioprostheses are associated with a low incidence of these complications, we decided to use bioprosthetic materials in the construction of a novel artificial heart (C-TAH). We report here the device characteristics and its first clinical applications in two patients with end-stage dilated cardiomyopathy. The aim of the study was to evaluate safety and feasibility of the CARMAT TAH for patients at imminent risk of death from biventricular heart failure and not eligible for transplant. METHODS: The C-TAH is an implantable electro-hydraulically actuated pulsatile biventricular pump. All components, batteries excepted, are embodied in a single device positioned in the pericardial sac after excision of the native ventricles. We selected patients admitted to hospital who were at imminent risk of death, having irreversible biventricular failure, and not eligible for heart transplantation, from three cardiac surgery centres in France. FINDINGS: The C-TAH was implanted in two male patients. Patient 1, aged 76 years, had the C-TAH implantation on Dec 18, 2013; patient 2, aged 68 years, had the implantation on Aug 5, 2014. The cardiopulmonary bypass times for C-TAH implantation were 170 min for patient 1 and 157 min for patient 2. Both patients were extubated within the first 12 postoperative hours and had a rapid recovery of their respiratory and circulatory functions as well as a normal mental status. Patient 1 presented with a tamponade on day 23 requiring re-intervention. Postoperative bleeding disorders prompted anticoagulant discontinuation. The C-TAH functioned well with a cardiac output of 4·8-5·8 L/min. On day 74, the patient died due to a device failure. Autopsy did not detect any relevant thrombus formation within the bioprosthesis nor the different organs, despite a 50-day anticoagulant-free period. Patient 2 experienced a transient period of renal failure and a pericardial effusion requiring drainage, but otherwise uneventful postoperative course. He was discharged from the hospital on day 150 after surgery with a wearable system without technical assistance. After 4 months at home, the patient suffered low cardiac output. A change of C-TAH was attempted but the patient died of multiorgan failure. INTERPRETATION: This preliminary experience could represent an important contribution to the development of total artificial hearts using bioprosthetic materials. FUNDING: CARMAT SA.


Assuntos
Bioprótese , Cardiomiopatia Dilatada/cirurgia , Transplante de Coração/instrumentação , Coração Artificial , Idoso , Evolução Fatal , Estudos de Viabilidade , Transplante de Coração/métodos , Humanos , Masculino , Resultado do Tratamento
15.
Eur J Cardiothorac Surg ; 47(5): e172-8; discussion e178-9, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25719178

RESUMO

OBJECTIVES: The Carmat bioprosthetic total artificial heart (TAH) contains bioprosthetic blood-contacting surfaces, and is designed for orthotopic cardiac replacement. In preparation for clinical studies, we evaluated the TAH performance and its effects on end-organ function in an animal model. METHODS: Twelve female Charolais calves, 2-3 months of age and weighing 102-122 kg, were implanted with the TAH through a mid-sternotomy to ensure an adequate anatomic fit. The intended support duration was 4-10 days. Haematological values, creatinine, bilirubin and lactate levels were measured and mean arterial and central venous pressure, central venous oxygen saturation and TAH parameters were monitored. RESULTS: The calves were placed in a cage immediately postoperatively, and extubated on postoperative day 1 in most cases. Average support duration was 3 days, with 4 of 12 calves supported for 4, 4, 8 and 10 days. The initial procedures were used to refine surgical techniques and postoperative care. Pump output ranged from 7.3 to 10 l/min. Haemodynamic parameters and blood analysis were within acceptable ranges. No device failures occurred. No anticoagulation was used in the postoperative phase. The calves were euthanized in case of discomfort compromising the animal well-being, such as respiratory dysfunction, severe blood loss and cerebral dysfunction. Device explant analysis showed no thrombus formation inside the blood cavities. Histological examination of kidneys showed isolated micro-infarction in 2/12 animals; brain histology revealed no thromboembolic depositions. CONCLUSION: The Carmat bioprosthetic TAH implanted in calves up to 10 days provided adequate blood flow to organs and tissues. Low levels of haemolysis and no visible evidence of thromboembolic depositions in major organs and device cavities, without the use of anticoagulation, may indicate early-phase haemocompatibility of the TAH.


Assuntos
Bioprótese , Insuficiência Cardíaca/cirurgia , Coração Artificial , Implantação de Prótese/métodos , Animais , Bovinos , Modelos Animais de Doenças , Feminino , Transplante de Coração , Desenho de Prótese
16.
J Thorac Cardiovasc Surg ; 149(2 Suppl): S37-45, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25240525

RESUMO

OBJECTIVE: The study objective was to compare the 30-day outcomes of a standardized aortic valve repair technique (REPAIR group) associating root remodeling with an expansible aortic ring annuloplasty versus mechanical composite valve and graft (CVG group) replacement in treating aortic root aneurysms. METHODS: A total of 261 consecutive patients with aortic root aneurysm were enrolled in this multicentric prospective cohort (131 in the CVG group, 130 in the REPAIR group) in 20 centers. The main end point is a composite criterion including mortality; reoperation; thromboembolic, hemorrhagic, or infectious events; and heart failure. Secondary end points were major adverse valve-related events. Crude and propensity score adjusted estimates are provided. RESULTS: The mean age was 56.1 years, and the valve was bicuspid in 115 patients (44.7%). The median (interquartile range) preoperative aortic insufficiency grade was 2.0 (1.0-3.0) in the REPAIR group and 3.0 (2.0-3.0) in the CVG group (P = .0002). Thirty-day mortality was 3.8% (n = 5) in both groups (P = 1.00). Despite a learning curve and longer crossclamp times for valve repair (147.7 vs 99.8 minutes, P < .0001), the 2 groups did not differ significantly for the main criterion (odds ratio, 1.31; 95% confidence interval, 0.72-2.40; P = .38) or 30-day mortality (odds ratio, 0.99; 95% confidence interval, 0.28-3053; P = .99), with a trend toward more frequent major adverse valve-related events in the CVG group (odds ratio, 2.52; 95% confidence interval, 0.86-7.40; P = .09). At discharge, 121 patients (96.8%) in the REPAIR group had grade 0 or 1 aortic insufficiency. CONCLUSIONS: A new standardized approach to valve repair, combining an expansible aortic annuloplasty ring with the remodeling technique, presented similar 30-day results to mechanical CVG with a trend toward reducing major adverse valve-related events. Analysis of late outcomes is in process for 3- and 10-year follow-ups.


Assuntos
Aneurisma Aórtico/cirurgia , Valva Aórtica/anormalidades , Implante de Prótese Vascular , Anuloplastia da Valva Cardíaca , Doenças das Valvas Cardíacas/cirurgia , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Adulto , Idoso , Idoso de 80 Anos ou mais , Aneurisma Aórtico/diagnóstico , Aneurisma Aórtico/mortalidade , Valva Aórtica/cirurgia , Doença da Válvula Aórtica Bicúspide , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/mortalidade , Anuloplastia da Valva Cardíaca/efeitos adversos , Anuloplastia da Valva Cardíaca/mortalidade , Distribuição de Qui-Quadrado , Intervalo Livre de Doença , Feminino , França , Doenças das Valvas Cardíacas/diagnóstico , Doenças das Valvas Cardíacas/mortalidade , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/mortalidade , Humanos , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Razão de Chances , Preferência do Paciente , Complicações Pós-Operatórias/mortalidade , Complicações Pós-Operatórias/cirurgia , Pontuação de Propensão , Estudos Prospectivos , Desenho de Prótese , Reoperação , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Adulto Jovem
18.
Respir Physiol Neurobiol ; 171(2): 151-6, 2010 Apr 30.
Artigo em Inglês | MEDLINE | ID: mdl-20219698

RESUMO

The change in exhaled NO after cardio-pulmonary bypass remains controversial. The aims were to determine whether exhaled NO sources (alveolar or bronchial) are modified after bypass, and whether mechanical ventilation (MV) settings during bypass modify exhaled NO changes. Thirty-two patients were divided into three groups: without MV during bypass and positive end-expiratory pressure (PEEP) (n=12), dead space MV without PEEP (n=10) and dead space MV with PEEP (n=10). Alveolar NO concentration and bronchial NO flux were calculated before and 1h after surgery using a two-compartment model of NO exchange developed in spontaneous breathing patients. Whereas a significant decrease in bronchial NO was found after bypass in the two groups without PEEP during bypass, this decrease was not observed in patients with dead space ventilation with PEEP. Alveolar NO was not significantly modified whatever the ventilation settings. In conclusion, the impairment of bronchial NO seemed related to airway closure since dead space mechanical ventilation with PEEP prevented its decrease.


Assuntos
Brônquios/metabolismo , Procedimentos Cirúrgicos Cardíacos , Ponte Cardiopulmonar/efeitos adversos , Expiração , Lesão Pulmonar/metabolismo , Óxido Nítrico/análise , Alvéolos Pulmonares/metabolismo , Idoso , Idoso de 80 Anos ou mais , Biomarcadores/análise , Feminino , Humanos , Lesão Pulmonar/etiologia , Masculino , Pessoa de Meia-Idade , Respiração com Pressão Positiva/métodos , Respiração Artificial/métodos , Espaço Morto Respiratório
19.
Ann Thorac Surg ; 89(3): 768-72, 2010 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-20172124

RESUMO

BACKGROUND: Stent deployment within stenotic native aortic valves has been shown to depend on valve anatomy (presence of bicuspid valve or not). This study investigated the influence of stent stiffness on stent expansion. METHODS: The study included 88 patients with severe aortic stenosis, and 36 (41%) had bicuspid aortic valves. Two self-expandable stents with different radial force were deployed intraoperatively inside stenotic aortic valves before surgical aortic valve replacement. Patients in group B received a stent stiffer than that in group A. Effect of stent radial force on stent shape and incidence of paraprosthetic gaps was determined. RESULTS: Noncircular stent deployment was more frequent in bicuspid (81%) than in tricuspid aortic valves (33%; p < 0.0001). Increasing stent radial force significantly improved stent shape in tricuspid valves (circular shape: 60% in group A vs 93% in group B; p = 0.005) but had no significant effect in bicuspid valves (12.5% in group A vs 27% in group B;p = 0.394). Likewise, incidence of paraprosthetic gaps was significantly reduced with the stiff stent in tricuspid valves (64% in group A vs 30% in group B, p = 0.025) but not in bicuspid valves (50% in group A vs 60% in group B; p= 0.722). CONCLUSIONS: Increased stent radial force had a favorable effect on stent deployment in tricuspid but not in bicuspid valves. In bicuspid valves, stent maldeployment was constant. Leaflet distortion of implanted valved stent might be a concern in this setting.


Assuntos
Estenose da Valva Aórtica/terapia , Valva Aórtica/patologia , Stents , Adulto , Idoso , Idoso de 80 Anos ou mais , Fenômenos Biomecânicos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
20.
J Clin Microbiol ; 47(12): 4180-2, 2009 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-19812272

RESUMO

We report a case of Finegoldia magna (formerly known as Peptostreptococcus magnus) mediastinitis following coronary artery bypass in a 50-year-old patient. Even if staphylococci remain the main causative organism of postoperative mediastinitis, the responsibility of anaerobic bacteria must be considered in cases of fever and sternal drainage with negative blood cultures.


Assuntos
Ponte de Artéria Coronária/efeitos adversos , Infecções por Bactérias Gram-Positivas/microbiologia , Mediastinite/microbiologia , Peptostreptococcus , Complicações Pós-Operatórias/microbiologia , Anaerobiose , Sangue/microbiologia , Meios de Cultura , Humanos , Masculino , Pessoa de Meia-Idade , Peptostreptococcus/classificação , Peptostreptococcus/crescimento & desenvolvimento , Peptostreptococcus/isolamento & purificação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA