Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
J Card Surg ; 37(10): 3436-3439, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35900304

RESUMO

BACKGROUND AND AIMS: Epithelioid hemangioendothelioma is a rare malignant vascular tumor with limited literature. AIMS: We reported an innovative endovascular biopsy of the right innominate vein tumor. MATERIALS AND METHODS: Endovascular suction thrombectomy was performed with multipurpose catheter and constant negative pressure under fluoroscopic guidance. RESULTS: Epithelioid hemangioendothelioma was diagnosed preoperatively and a complete margin-free tumor resection with patch repair of the right innominate vein was achieved via sternotomy. DISCUSSION: Preoperatively diagnosis is usually not available due to lesions' location. Identifying malignant vascular tumors becomes valuable to guide the surgical treatment. CONCLUSIONS: In this case report, this innovative endovascular approach led to a rare preoperative diagnosis of EHE and subsequent margin-free resection.


Assuntos
Hemangioendotelioma Epitelioide , Sarcoma , Adulto , Biópsia , Veias Braquiocefálicas/diagnóstico por imagem , Veias Braquiocefálicas/patologia , Veias Braquiocefálicas/cirurgia , Criança , Hemangioendotelioma Epitelioide/diagnóstico , Hemangioendotelioma Epitelioide/patologia , Hemangioendotelioma Epitelioide/cirurgia , Humanos , Sarcoma/patologia , Trombectomia
2.
J Card Surg ; 37(9): 2727-2731, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35766011

RESUMO

BACKGROUND: Stroke remains one of the most important complications of cardiac surgery and occurs in 2.2% after open-heart procedure. It is associated with significant morbidity and mortality. The use of a cerebral protection system during transcatheter aortic valve implantation may be associated with a lower risk of periprocedural strokes, and mortality at 30 days. The aim of the present study was to assess the safety and feasibility of this device in patients at high risk for stroke during open cardiac surgery. METHODS: We present six patients with a high risk of perioperative stroke who underwent placement of Sentinel cerebral protection system during various open-heart operations between 2018 and 2021. RESULTS: The system was successfully deployed, and debris was retrieved in all patients. There was no device-related complication or development of ischemic stroke postoperatively. One patient suffered from intracranial hemorrhage due to peri-operative coagulopathy. CONCLUSIONS: We demonstrated the feasibility and safety of this hybrid approach with a high debris capture rate. It encourages further study to evaluate the benefits of the Sentinel cerebral protection system in reducing stroke and mortality in selected patients undergoing open-heart surgery.


Assuntos
Estenose da Valva Aórtica , Dispositivos de Proteção Embólica , Embolia Intracraniana , Acidente Vascular Cerebral , Substituição da Valva Aórtica Transcateter , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Humanos , Embolia Intracraniana/etiologia , Desenho de Prótese , Fatores de Risco , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
4.
Drug Test Anal ; 12(9): 1274-1286, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32558326

RESUMO

The use of bioactive peptides as a doping agent in both human and animal sports has become increasingly popular in recent years. As such, methods to control the misuse of bioactive peptides in equine sports have received attention. This paper describes a sensitive accurate mass method for the detection of 40 bioactive peptides and two non-peptide growth hormone secretagogues (< 2 kDa) at low pg/mL levels in horse urine using ultra-high performance liquid chromatography-high resolution mass spectrometry (UHPLC/HRMS). A simple mixed-mode cation exchange solid-phase extraction (SPE) cartridge was employed for the extraction of 42 targets and/or their in vitro metabolites from horse urine. The final extract was analyzed using UHPLC/HRMS in positive electrospray ionization (ESI) mode under both full scan and data independent acquisition (DIA, for MS2 ). The estimated limits of detection (LoD) for most of the targets could reach down to 10 pg/mL in horse urine. This method was validated for qualitative detection purposes. The validation data, including method specificity, method sensitivity, extraction recovery, method precision, and matrix effect were reported. A thorough in vitro study was also performed on four gonadotrophin-releasing factors (GnRHs), namely leuprorelin, buserelin, goserelin, and nafarelin, using the S9 fraction isolated from horse liver. The identified in vitro metabolites have been incorporated into the method for controlling the misuse of GnRHs. The applicability of this method was demonstrated by the identification of leuprorelin and one of its metabolites, Leu M4, in urine obtained after intramuscular administration of leuprorelin to a thoroughbred gelding (castrated horse).


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Espectrometria de Massas/métodos , Peptídeos/análise , Detecção do Abuso de Substâncias/métodos , Animais , Dopagem Esportivo , Hormônio Liberador de Gonadotropina/análise , Hormônio Liberador de Gonadotropina/urina , Cavalos , Humanos , Leuprolida/análise , Leuprolida/urina , Limite de Detecção , Masculino , Peptídeos/urina , Reprodutibilidade dos Testes , Extração em Fase Sólida
6.
Anal Bioanal Chem ; 405(8): 2595-606, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23318763

RESUMO

In recent years, there has been an ongoing focus for both human and equine doping control laboratories on developing detection methods to control the misuse of peptide therapeutics. Immunoaffinity purification is a common extraction method to isolate peptides from biological matrices and obtain sufficient detectability in subsequent instrumental analysis. However, monoclonal or polyclonal antibodies for immunoaffinity purification may not be commercially available, and even if available, such antibodies are usually very costly. In our study, a simple mixed-mode anion exchange solid-phase extraction cartridge was employed for the extraction of seven target peptides (GHRP-1, GHRP-2, GHRP-6, ipamorelin, hexarelin, CJC-1295, and N-acetylated LKKTETQ (active ingredient of TB-500)) and their in vitro metabolites from horse plasma. The final extract was subject to ultra-high-performance liquid chromatographic separation and analysed with a hybrid high-resolution mass spectrometer. The limits of detection for all seven peptides were estimated to be less than 50 pg/mL. Method validation was performed with respect to specificity, precision, and recovery. The applicability of this multi-analyte method was demonstrated by the detection of N-acetylated LKKTETQ and its metabolite N-acetylated LK from plasma samples obtained after subcutaneous administration of TB-500 (10 mg N-acetylated LKKTETQ) to two thoroughbred geldings. This method could easily be modified to cover more bioactive peptides, such as dermorphin, ß-casomorphin, and desmopressin. With the use of high-resolution mass spectrometry, the full-scan data acquired can also be re-processed retrospectively to search for peptides and their metabolites that have not been targeted at the time of analysis. To our knowledge, this is the first identification of in vitro metabolites of all the studied peptides other than TB-500 in horses.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Dopagem Esportivo , Cavalos/sangue , Espectrometria de Massas/métodos , Peptídeos/sangue , Detecção do Abuso de Substâncias/veterinária , Animais , Dopagem Esportivo/prevenção & controle , Peptídeos/isolamento & purificação , Extração em Fase Sólida , Detecção do Abuso de Substâncias/métodos
7.
Int Orthop ; 33(5): 1401-5, 2009 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-19050884

RESUMO

Fifty-two patients with unstable fractures of distal clavicle treated by open reduction and internal fixation with hook plates or tension band wires were retrospectively reviewed. The 52 patients were divided into two groups based on the method of treatment. The hook plate (HP) group included 32 patients and the tension band wire (TBW) group included 20 patients. Both groups were similar in respect to injury mechanisms, compounding medical conditions, and shoulder score (p > 0.1). However, hook plating had a significantly lower rate of complication (p = 0.01) and symptomatic hardware (p = 0.001). In addition, hook plating better facilitated the return to work and athletic activity (p = 0.004 and p = 0.003, respectively). In conclusion, if surgery of distal clavicular fractures is indicated, internal fixation with a hook plate has more advantages than with tension band wires.


Assuntos
Clavícula/lesões , Fixação Interna de Fraturas/instrumentação , Fraturas Mal-Unidas/cirurgia , Fixadores Internos , Fraturas do Ombro/cirurgia , Adolescente , Adulto , Idoso , Placas Ósseas , Fios Ortopédicos , Clavícula/diagnóstico por imagem , Clavícula/cirurgia , Emprego , Feminino , Fixação Interna de Fraturas/métodos , Consolidação da Fratura , Fraturas Mal-Unidas/diagnóstico por imagem , Humanos , Escala de Gravidade do Ferimento , Fixadores Internos/classificação , Masculino , Pessoa de Meia-Idade , Radiografia , Recuperação de Função Fisiológica , Estudos Retrospectivos , Fraturas do Ombro/diagnóstico por imagem , Resultado do Tratamento , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA