Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J Biomech ; 168: 112110, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38677025

RESUMO

Rotator cuff (RC) tears are a common source of pain and decreased shoulder strength. Muscle length is known to affect muscle strength, and therefore evaluating changes in supraspinatus muscle length associated with RC pathology, surgical repair, and post-operative recovery may provide insights into functional deficits. Our objective was to develop a reliable MRI-based approach for assessing supraspinatus muscle length. Using a new semi-automated approach for identifying 3D location of the muscle-tendon junction (MTJ), supraspinatus muscle length was calculated as the sum of MTJ distance (distance between 3D MTJ position and glenoid plane) and supraspinatus fossa length (distance between root of the scapular spine and glenoid plane). Inter- and intra-operator reliability of this technique were assessed with intraclass correlation coefficient (ICC) and found to be excellent (ICCs > 0.96). Muscle lengths of 6 patients were determined before RC repair surgery and at 3- and 12-months post-surgery. Changes in normalized muscle length (muscle length as a percentage of pre-surgical muscle length) at 3 months post-surgery varied considerably across patients (16.1 % increase to 7.0 % decrease) but decreased in all patients from 3- to 12-months post-surgery (0.3 % to 17.2 %). This study developed a novel and reliable approach for quantifying supraspinatus muscle length and provided preliminary demonstration of its utility by assessing muscle length changes associated with RC pathology and surgical repair. Future studies can use this technique to evaluate changes over time in supraspinatus muscle length in response to clinical intervention, and associations between muscle length and shoulder function.


Assuntos
Imageamento Tridimensional , Imageamento por Ressonância Magnética , Lesões do Manguito Rotador , Manguito Rotador , Humanos , Imageamento por Ressonância Magnética/métodos , Manguito Rotador/diagnóstico por imagem , Manguito Rotador/cirurgia , Manguito Rotador/fisiologia , Masculino , Lesões do Manguito Rotador/cirurgia , Lesões do Manguito Rotador/diagnóstico por imagem , Lesões do Manguito Rotador/fisiopatologia , Pessoa de Meia-Idade , Feminino , Imageamento Tridimensional/métodos , Idoso , Adulto , Músculo Esquelético/diagnóstico por imagem , Músculo Esquelético/fisiologia , Reprodutibilidade dos Testes
2.
Arch Phys Med Rehabil ; 104(3): 403-409, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36202228

RESUMO

OBJECTIVE: To better understand how the shoulder moves in breast cancer survivors with axillary web syndrome (AWS), we compared 3-dimensional (3D) shoulder kinematics during shoulder elevation among breast cancer survivors with and without AWS 5 years postoperatively. Although research consistently shows decreased shoulder range of motion with AWS, we do not understand the underlying biomechanics. DESIGN: Nested case control study. SETTING: University Academic Breast Center. PARTICIPANTS: Twenty-five women who had surgery 5 years previously for unilateral breast cancer with the removal of at least 1 lymph node participated in this study (N=25). Twelve participants had AWS; 13 women did not have AWS. INTERVENTIONS: Not applicable. MAIN OUTCOME MEASURES: Three-dimensional shoulder kinematic data during shoulder forward flexion, scapular plane abduction, and coronal plane abduction were collected using 3D electromagnetic motion tracking. Kinematic data were extracted at 30°, 60°, 90°, and 120° of arm elevation for scapular upward rotation, internal rotation, and posterior tilt as well as for glenohumeral external rotation. RESULTS: Women with AWS demonstrated 15.2° less scapular upward rotation at 120° humerothoracic elevation (95% confidence interval [-25.2, -5.2], P=.005), regardless of plane. No significant between-group differences were found for any other angle of scapular upward rotation, nor for scapular internal rotation, scapular posterior tilt, or glenohumeral axial rotation at any angle. CONCLUSIONS: Five years after surgery for breast cancer, women diagnosed with AWS have altered scapulohumeral kinematics that may place them at an increased risk of shoulder pain based on existing kinematic literature in healthy cohorts. This information can help guide rehabilitation programs for breast cancer survivors to facilitate pain-free upper extremity function after treatment.


Assuntos
Neoplasias da Mama , Articulação do Ombro , Humanos , Feminino , Ombro , Fenômenos Biomecânicos , Estudos de Casos e Controles , Escápula , Amplitude de Movimento Articular
3.
Orthop J Sports Med ; 10(3): 23259671221084294, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35387360

RESUMO

Background: Rotator cuff repair is a common orthopaedic procedure that provides pain relief for many patients, but unfortunately, an estimated 20% to 70% of repair procedures will fail. Previous research has shown that elongation (ie, retraction) of a repaired tendon is common even in patients with a repair construct that appears intact on magnetic resonance imaging. However, it is unknown how this repair tissue functions under dynamic conditions. Purpose: To quantify static retraction and maximum dynamic elongation of repair tissue after rotator cuff repair. Study Design: Case series; Level of evidence, 4. Methods: Data from 9 patients were analyzed for this study. During surgery, a 3.1-mm tantalum bead was sutured to the supraspinatus tendon, medial to the repair site. Glenohumeral kinematics were assessed at 1 week (static) and 3 months (static and during scapular-plane abduction) after surgery using a biplanar videoradiographic system. The 3-dimensional position of the bead was calculated relative to the tendon's insertion on the humerus (ie, bead-to-insertion distance). Static retraction was calculated as the change in the bead-to-insertion distance under static conditions between 1 week and 3 months after surgery, and maximum dynamic elongation was calculated as the maximal positive change in the bead-to-insertion distance during dynamic motion relative to the start of motion. The magnitudes of static retraction and maximum dynamic elongation were assessed with 1-sample t tests. Results: At 3 months after surgery, static retraction occurred in all patients by a mean of 10.0 ± 9.1 mm (P = .01 compared with no elongation). During scapular-plane abduction, maximum dynamic elongation averaged 1.4 ± 1.0 mm (P < .01 compared with no elongation). Descriptively, dynamic elongation consistently took 1 of 2 forms: an initial increase in the bead-to-insertion distance (mean, 2.0 ± 0.6 mm) before decreasing until the end of motion or an immediate and substantial decrease in the bead-to-insertion distance at the onset of motion. Conclusion: Repair tissue elongation (static retraction and maximum dynamic elongation) appeared to be a common and significant finding at 3 months after arthroscopic rotator cuff repair. Dynamic elongation of repair tissue during scapular-plane abduction exhibited 1 of 2 distinct patterns, which may suggest different patterns of supraspinatus mechanical and neuromuscular function.

4.
JSES Int ; 6(1): 62-69, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-35141678

RESUMO

BACKGROUND: Rotator cuff repair provides pain relief for many patients; however, retears are relatively common and affect approximately 20%-70% of patients after repair. Although magnetic resonance imaging (MRI) offers the ability to assess tissue characteristics such as tear size, retraction, and fatty infiltration, it provides little insight into the quality of the musculotendinous tissues the surgeon will encounter during surgery. However, shear wave elastography (SWE) could provide an indirect assessment of quality (ie, stiffness) by measuring the speed of shear waves propagating through tissue. The objective of this study was to determine the extent to which estimated shear modulus predicts repair integrity and functional outcomes 1 year after rotator cuff repair. METHODS: Thirty-three individuals scheduled to undergo arthroscopic rotator cuff repair were enrolled in this study. Before surgery, shear modulus of the supraspinatus tendon and muscle was estimated using ultrasound SWE. MRIs were obtained before and 1 year after surgery to assess tear characteristics and repair integrity, respectively. Shoulder strength, range of motion, and patient-reported pain and function were assessed before and after surgery. Functional outcomes were compared between groups and across time using a two-factor mixed model analysis of variance. Stepwise regression with model comparison was used to investigate the extent to which MRI and shear modulus predicted repair integrity and function at 1 year after surgery. RESULTS: At 1 year after surgery, 56.5% of patients had an intact repair. No significant differences were found in any demographic variable, presurgical tear characteristic, or shear modulus between patients with an intact repair and those with a recurrent tear. Compared with presurgical measures, patients in both groups demonstrated significant improvements at 1 year after surgery in pain (P < .01), self-reported function (P < .01), range of motion (P < .01), and shoulder strength (P < .01). In addition, neither presurgical MRI variables (P > .16) nor shear modulus (P > .52) was significantly different between groups at 1 year after surgery. Finally, presurgical shear modulus generally did not improve the prediction of functional outcomes above and beyond that provided by MRI variables alone (P > .22). CONCLUSION: Although SWE remains a promising modality for many clinical applications, this study found that SWE-estimated shear modulus did not predict repair integrity or functional outcomes at 1 year after surgery, nor did it add to the prediction of outcomes above and beyond that provided by traditional presurgical MRI measures of tear characteristics. Therefore, it appears that further research is needed to fully understand the clinical utility of SWE for musculoskeletal tissue and its potential use for predicting outcomes after surgical rotator cuff repair.

5.
Med Biol Eng Comput ; 52(3): 211-9, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23572144

RESUMO

"Impingement syndrome" is a common diagnostic label for patients presenting with shoulder pain. Historically, it was believed to be due to compression of the rotator cuff tendons beneath the acromion. It has become evident that "impingement syndrome" is not likely an isolated condition that can be easily diagnosed with clinical tests or most successfully treated surgically. Rather, it is likely a complex of conditions involving a combination of intrinsic and extrinsic factors. A mechanical impingement phenomenon as an etiologic mechanism of rotator cuff disease may be distinct from the broad diagnostic label of "impingement syndrome". Acknowledging the concepts of mechanical impingement and movement-related impairments may better suit the diagnostic and interventional continuum as they support the existence of potentially modifiable impairments within the conservative treatment paradigm. Therefore, it is advocated that the clinical diagnosis of "impingement syndrome" be eliminated as it is no more informative than the diagnosis of "anterior shoulder pain". While both terms are ambiguous, the latter is less likely to presume an anatomical tissue pathology that may be difficult to isolate either with a clinical examination or with diagnostic imaging and may prevent potentially inappropriate surgical interventions. We further recommend investigation of mechanical impingement and movement patterns as potential mechanisms for the development of shoulder pain, but clearly distinguished from a clinical diagnostic label of "impingement syndrome". For shoulder researchers, we recommend investigations of homogenous patient groups with accurately defined specific pathologies, or with subgrouping or classification based on specific movement deviations. Diagnostic labels based on the movement system may allow more effective subgrouping of patients to guide treatment strategies.


Assuntos
Síndrome de Colisão do Ombro/diagnóstico , Síndrome de Colisão do Ombro/cirurgia , Humanos , Ortopedia/métodos , Modalidades de Fisioterapia , Manguito Rotador , Síndrome de Colisão do Ombro/etiologia , Síndrome de Colisão do Ombro/terapia , Tendões
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA