Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Front Cardiovasc Med ; 10: 1213165, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37547255

RESUMO

Background: Cardiac sarcoidosis is associated with heart failure, conduction abnormalities, and life-threatening arrhythmias including ventricular tachycardia (VT). Radiotherapy has been suggested as a treatment for extra-cardiac sarcoidosis in patients refractory to immunomodulatory treatment. Methods: The effectiveness and safety of low-dose whole-heart radiotherapy for therapy refractory cardiac sarcoidosis were evaluated in a pre- and post-intervention case report comparing the 54 months before and after treatment. Immunomodulatory low-dose whole-heart irradiation as sarcoidosis treatment consisted of a 2 × 2 Gy scheme. Additionally, high-dose single-fraction stereotactic arrhythmia radioablation of 1 × 20 Gy was applied to the pro-arrhythmic region to manage the ventricular tachycardia episodes. Cardiac sarcoidosis disease activity was measured by hypermetabolic areas on repeated fluorodeoxyglucose ([18F]FDG)-PET/computed tomography (CT) scans and by evaluating changes in ventricular tachycardia episodes before and after treatment. Results: One patient with therapy refractory progressive cardiac sarcoidosis and recurrent ventricular tachycardia was treated. The cardiac sarcoidosis disease activity showed a durable regression of inflammatory disease activity from 3 months onwards. The [18F]FDG-PET/CT scan at 54 months did not show any signs of active cardiac sarcoidosis, and a state of remission was achieved. The number of sustained VT episodes was reduced by 95%. We observed that the development of moderate aortic valve regurgitation was likely irradiation-related. No other irradiation-related adverse events occurred, and the left ventricular ejection fraction remained stable. Conclusion: We report here for the first time on the beneficial and lasting effects of combined immunomodulatory low-dose whole-heart radiotherapy and high-dose stereotactic arrhythmia radioablation in a patient with therapy refractory cardiac sarcoidosis and recurrent VT.

2.
JACC Clin Electrophysiol ; 7(2): 161-170, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33602396

RESUMO

OBJECTIVES: This study sought to investigate the RADPAD No Brainer (Worldwide Innovation and Technologies, Overland Park, Kansas) efficiency in reducing brain exposure to scattered radiation. BACKGROUND: Cranial radioprotective caps such as the RADPAD No Brainer are being marketed as devices that significantly reduce operator's brain exposure to scattered radiation. However, the efficiency of the RADPAD No Brainer in reducing brain exposure in clinical practice remains unknown to date. METHODS: Five electrophysiologists performing device implantations over a 2-month period wore the RADPAD cap with 2 strips of 11 thermoluminescent dosimeter pellets covering the front head above and under the shielded cap. Phantom measurements and Monte Carlo simulations were performed to further investigate brain dose distribution. RESULTS: Our study showed that the right half of the operators' front head was the most exposed region during left subpectoral device implantation; the RADPAD cap attenuated the skin front-head exposure but provided no protection to the brain. The exposure of the anterior part of the brain was decreased by a factor of 4.5 compared with the front-head skin value thanks to the skull. The RADPAD cap worn as a protruding horizontal plane, however, reduced brain exposure by a factor of 1.7 (interquartile range: 1.3 to 1.9). CONCLUSIONS: During device implantation, the RADPAD No Brainer decreased the skin front head exposure but had no impact on brain dose distribution. The RADPAD No Brainer worn as a horizontal plane worn around the neck reduces brain exposure and confirms that the exposure comes from upward scattered radiation.


Assuntos
Exposição Ocupacional , Marca-Passo Artificial , Encéfalo/cirurgia , Desfibriladores , Fluoroscopia , Humanos , Marca-Passo Artificial/efeitos adversos , Doses de Radiação
3.
Expert Rev Cardiovasc Ther ; 19(1): 15-26, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33153326

RESUMO

Introduction: There are numerous challenges to catheter ablation in patients with congenital heart disease (CHD), including access to cardiac chambers, distorted anatomies, displaced conduction systems, multiple and/or complex arrhythmia substrates, and excessively thickened walls, or interposed material. Areas covered: Herein, we review recent developments in catheter ablation strategies for patients with CHD that are helpful in addressing these challenges. Expert opinion: Remote magnetic navigation overcomes many challenges associated with vascular obstructions, chamber access, and catheter contact. Patients with CHD may benefit from a range of ablation catheter technologies, including irrigated-tip and contact-force radiofrequency ablation and focal and balloon cryoablation. High-density mapping, along with advances in multipolar catheters and interpolation algorithms, is contributing to new mechanistic insights into complex arrhythmias. Ripple mapping allows the activation wave front to be tracked visually without prior assignment of local activation times or window of interest, and without interpolations of unmapped regions. There is growing interest in measuring conduction velocities to identify arrhythmogenic substrates. Noninvasive mapping with a multielectrode-embedded vest allows prolonged bedside monitoring, which is of particular interest in those with non-sustained or multiple arrhythmias. Further studies are required to assess the role of radiofrequency needle catheters and stereotactic radiotherapy in patients with CHD.


Assuntos
Arritmias Cardíacas/cirurgia , Ablação por Cateter/métodos , Cardiopatias Congênitas/cirurgia , Ablação por Cateter/efeitos adversos , Criocirurgia/métodos , Humanos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA