Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-39146514

RESUMO

The management of superior sinus venosus defects (SVD) via transcatheter covered stent (CS) placement is becoming an acceptable alternative to open heart surgery. Though the medium-term success of this procedure has been described, residual shunting from damage to the covering of the implanted stents, use of stents which are too short and unanticipated shortening of stents may result in immediate or short-term procedural failure. In such cases, placement of a second CS may be required to address a residual defect. Preprocedural prediction of the length of stent required for residual leak treatment may not be as accurate as predicting the required stent length in a native defect, meaning that compassionate use applications to facilitate acquiring non-standard stent and balloon combinations may not be practical. We present a successful case of residual SVD closure using a novel sutured telescoping stent technique. Further collaboration with industry should encourage regulatory approval of longer CS, to mitigate the need for potentially unpredictable modifications such as this.

2.
Cardiol Young ; 33(9): 1760-1762, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-36999364

RESUMO

A 4-year-old boy presented to our institution with pancytopenia, consumptive coagulopathy, hepatosplenomegaly and recurrent complex pericardial effusion secondary to kaposiform lymphagiomatosis. Due to extensive loculation, conventional drainage was minimally effective. As an adjunct to medical therapy, the Indigo™ aspiration system was used to remove thrombus within the pericardial space. Our patient had good medium-term results with complete resolution of his pericardial effusion at 4 months.


Assuntos
Derrame Pericárdico , Masculino , Humanos , Pré-Escolar , Derrame Pericárdico/diagnóstico , Derrame Pericárdico/etiologia , Derrame Pericárdico/cirurgia , Drenagem , Trombectomia , Pericárdio
3.
Artigo em Inglês | MEDLINE | ID: mdl-36244628

RESUMO

Evaluate the use of coronary CTA as an initial assessment for determining Right Ventricle Dependent Coronary Circulation (RVDCC) in neonates with Pulmonary Atresia with Intact Ventricular Septum (PA IVS). Retrospective review of cases with coronary CTA and compare with available catheter angiography, pathology, surgical reports, and outcomes from Mar 2015 to May 2022. In our cohort of 16 patients, 3 were positive for RVDCC, confirmed by pathologic evaluation, and there was concordance for presence or absence of RVDCC with catheter angiography in 5 patients (4 negatives for RVDCC, 1 positive). Clinical follow up for the 8 patients that underwent RV decompression had no clinical evidence of myocardial ischemia. Our findings suggest that coronary CTA is reliable as first-line imaging for determination of RVDCC in neonates with PA IVS. These findings, if supported by further prospective study, may reserve invasive coronary angiography for cases with diagnostic uncertainty or at the time of necessary transcatheter interventions.

4.
Pediatr Cardiol ; 42(4): 926-933, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33590323

RESUMO

The aim of the study is to evaluate the impact of multimodality imaging technology during percutaneous pulmonary valve implantation (PPVI). Among percutaneous procedures, PPVI traditionally has one of the highest patient radiation exposures. Different protocol modifications have been implemented to address this problem (i.e., improvements in guidance systems, delivery systems, valve design, post-implantation evaluation). Although the effectiveness of individual modifications has been proven, the effect of an approach which combines these changes has not been reported. We performed a retrospective chart review of 76 patients who underwent PPVI between January 2018 and December 2019. Patients were classified in "Traditional protocol," using routine biplane angiography and/or 3D rotational angiography (3DRA); and "Multimodality protocol" that included the use of VesselNavigator for guidance, selective 3DRA for coronary evaluation, Long DrySeal Sheath for valve delivery, and Intracardiac Echocardiography for valve evaluation after implantation. Radiation metrics, procedural time, and clinical outcomes were compared between groups. When the traditional protocol group was compared with the multimodality protocol group, a significant reduction was described for total fluoroscopy time (31.6 min vs. 26.2 min), dose of contrast per kilogram (1.8 mL/Kg vs. 0.9 mL/Kg), DAP/kg (26.6 µGy·m2/kg vs. 19.9 µGy·m2/kg), and Air Kerma (194 mGy vs. 99.9 mGy). A reduction for procedure time was noted (140 min vs. 116.5 min), but this was not statistically significant. There was no difference in clinical outcomes or the presence of complications between groups. The combination of novel technology in PPVI caused a significant reduction in radiation metrics without increasing the complication rate in our population.


Assuntos
Cardiopatias Congênitas/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Valva Pulmonar/cirurgia , Exposição à Radiação/prevenção & controle , Adolescente , Angiografia/métodos , Cateterismo Cardíaco/métodos , Procedimentos Cirúrgicos Cardíacos/métodos , Ecocardiografia/métodos , Feminino , Fluoroscopia/métodos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Masculino , Imagem Multimodal/efeitos adversos , Imagem Multimodal/métodos , Insuficiência da Valva Pulmonar/cirurgia , Exposição à Radiação/efeitos adversos , Estudos Retrospectivos , Resultado do Tratamento
5.
Circ Cardiovasc Interv ; 13(5): e008172, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-32408819

RESUMO

BACKGROUND: The C3PO-QI (Congenital Cardiac Catheterization Project on Outcomes - Quality Improvement), a multicenter registry launched in 2015, instituted quality improvement (QI) initiatives to reduce patient radiation exposure. Through regular collaboration, this initiative would allow for harmony among active participants, maximizing efforts and efficiency at achieving radiation best practices. This study sought to report these efforts with a detailed methodology for which institutions can target initiatives, reducing radiation exposure, and increasing patient safety. METHODS: Data were collected prospectively by 8 C3PO-QI institutions between January 1, 2015 and December 31, 2017. Radiation exposure was measured in dose area product per body weight (dose area product/kg; µGy*m2/kg) and reported by expected radiation exposure categories (REC) and institution for 40 published unique procedure types. Targeted interventions addressing selected strategic domains for radiation reduction were implemented in the pediatric catheterization labs of the C3PO-QI institutions. RESULTS: The study consisted of 15 257 unique cases. Median exposure (dose area product/kg) was decreased by 30% for all procedures. Dose area product/kg was reduced in all 3 REC, with the greatest improvement observed in REC I (REC I, -37%; REC II, -23%; REC III, -27%). Although the baseline radiation exposures and exact percent decrease varied across all C3PO-QI sites, each institution demonstrated improvements in radiation dose over time. These improvements occurred with the implementation of institution-specific QI interventions accelerated by participation in the C3PO-QI multicenter collaborative. CONCLUSIONS: Substantial radiation dose reductions can be achieved using targeted QI methodology and interventions. Participation in a multicenter QI collaborative may accelerate improvement across all centers due to enhanced engagement and shared learning between sites.


Assuntos
Cateterismo Cardíaco , Angiografia Coronária , Cardiopatias Congênitas/diagnóstico , Cardiopatias Congênitas/terapia , Doses de Radiação , Exposição à Radiação/prevenção & controle , Lesões por Radiação/prevenção & controle , Proteção Radiológica , Adolescente , Adulto , Cateterismo Cardíaco/efeitos adversos , Criança , Pré-Escolar , Angiografia Coronária/efeitos adversos , Bases de Dados Factuais , Feminino , Disparidades em Assistência à Saúde , Humanos , Lactente , Masculino , Segurança do Paciente , Estudos Prospectivos , Melhoria de Qualidade , Indicadores de Qualidade em Assistência à Saúde , Exposição à Radiação/efeitos adversos , Lesões por Radiação/etiologia , Medição de Risco , Fatores de Risco , Fatores de Tempo , Adulto Jovem
6.
J Am Coll Cardiol ; 75(4): 363-376, 2020 02 04.
Artigo em Inglês | MEDLINE | ID: mdl-32000947

RESUMO

BACKGROUND: Transcatheter pulmonary valve replacement (TPVR) is associated with a risk of procedural serious adverse events (SAE) and exposure to ionizing radiation. OBJECTIVES: The purpose of this study was to define the risk of, and associations with, SAE and high-dose radiation exposure using large-scale registry data. METHODS: The analysis of the multicenter C3PO-QI registry was limited to patients who underwent TPVR from January 1, 2014, to December 31, 2016. SAE were defined as the occurrence of ≥1 moderate, major, or catastrophic events. Radiation dose was reported as dose area product adjusted for weight. Associations with outcome measures were explored in univariate and multivariable analyses. RESULTS: A total of 530 patients (59% male) underwent TPVR at a median age of 18.3 years (interquartile range [IQR]: 12.9 to 27.3 years) and weight of 58 kg (IQR: 43 to 77 kg) at 14 centers. Implant substrate included homograft (41%), bioprosthesis (30%), native right ventricular outflow tract (RVOT) (27%) and other (2%). TPVR indications were pulmonary insufficiency (28%), stenosis (23%), and mixed (49%). AE and SAE occurred in 26% and 13% of cases, respectively, including 1 mortality. SAE were more frequent in homograft conduit than other RVOT substrates, although SAE type and severity differed between implant substrates. Median radiation dose was 198 µGy·m2/kg (IQR: 94 to 350 µGy·m2/kg). Higher radiation dose was associated with older age, greater RVOT obstruction, and concomitant interventions (p < 0.001). During a median follow-up duration of 1 year, 13.3% underwent catheterization, surgery, or both, unrelated to infection. Younger age, smaller size, and hemodynamic and anatomic factors indicative of greater RVOT obstruction were associated with TPV reintervention. CONCLUSIONS: The incidence of SAE during TPVR in the C3PO-QI registry is high, but mortality is uncommon. Radiation dose is greater than for other congenital interventions and is associated with patient and procedural factors. Reintervention is common during early follow-up.


Assuntos
Implante de Prótese de Valva Cardíaca/efeitos adversos , Próteses Valvulares Cardíacas , Insuficiência da Valva Pulmonar/cirurgia , Valva Pulmonar/cirurgia , Exposição à Radiação , Radiação Ionizante , Adolescente , Adulto , Cateterismo Cardíaco/efeitos adversos , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Cateterismo , Criança , Endocardite/cirurgia , Feminino , Cardiopatias Congênitas/cirurgia , Humanos , Incidência , Masculino , Análise Multivariada , Sistema de Registros , Risco , Tetralogia de Fallot/cirurgia , Adulto Jovem
7.
Pediatr Cardiol ; 40(2): 445-453, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30506273

RESUMO

To stratify diverse procedure types into categories with similar radiation exposure in cardiac catheterization for congenital heart disease. Radiation exposures for a comprehensive list of specific procedure types and stratification of outcomes based on radiation risk are not currently available. Data between January 2014 and December 2015 were collected on all cases performed at sites participating in C3PO-QI (Congenital Cardiac Catheterization Outcomes Project-Quality Improvement Initiative) and 9 centers were included. Using expert consensus, 40 unique procedure types were defined by diagnostic characteristics or the intervention(s) performed, and dose area product (DAP) per kilogram of body weight (µGy × m2/kg) was summarized. Using empiric and consensus methods, three radiation risk categories were created. A total of 11,735 cases were included for analysis. Thirteen (n = 7918) procedure types with median DAP/kg < 100 were categorized in the low radiation exposure category (median DAP/kg 39). The medium exposure category (n = 1807) consisted of 16 procedure types with median DAP/kg values ranging 100 to < 200 (overall median DAP/kg 131). Finally, the high radiation exposure category (n = 1073) consisted of 11 procedure types with median DAP/kg ≥ 200 (overall median DAP/kg of 231). The radiation exposure risk categories created in this multi-center dataset are a critical step towards the development of a robust risk adjustment methodology for radiation exposure in catheterization for congenital heart disease.


Assuntos
Cateterismo Cardíaco/efeitos adversos , Fluoroscopia/efeitos adversos , Cardiopatias Congênitas/cirurgia , Exposição à Radiação , Radiografia Intervencionista/efeitos adversos , Adolescente , Criança , Pré-Escolar , Consenso , Humanos , Lactente , Estudos Prospectivos , Melhoria de Qualidade , Doses de Radiação , Medição de Risco/métodos , Fatores de Risco , Adulto Jovem
8.
Catheter Cardiovasc Interv ; 90(2): 269-280, 2017 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-28198573

RESUMO

OBJECTIVES: This study sought to update benchmark values to use a quality measure prospectively. BACKGROUND: Congenital Cardiac Catheterization Outcomes Project - Quality Improvement (C3PO-QI), a multi-center registry, defined initial radiation dose benchmarks retrospectively across common interventional procedures. These data facilitated a dose metric endorsed by the American College of Cardiology in 2014. METHODS: Data was collected prospectively by 9 C3PO-QI institutions with complete case capture between 1/1/2014 and 6/30/2015. Radiation was measured in total air kerma (mGy), dose area product (DAP) (µGy*M2 ), DAP per body weight, and fluoroscopy time (min), and reported by age group as median, 75th and 95th %ile for the following six interventional procedures: (1) atrial septal defect closure; (2) aortic valvuloplasty; (3) treatment of coarctation of the aorta; (4) patent ductus arteriosus closure; (5) pulmonary valvuloplasty; and (6) transcatheter pulmonary valve implantation. RESULTS: The study was comprised of 1,680 unique cases meeting inclusion criteria. Radiation doses were lowest for pulmonary valvuloplasty (age <1 yrs, median mGy: 59, DAP: 249) and highest in transcatheter pulmonary valve implantation (age >15 yrs, median mGy: 1835, DAP: 17990). DAP/kg standardized outcome measures across weights within an age group and procedure type significantly more than DAP alone. Radiation doses decreased for all procedures compared to those reported previously by both median and median weight-based percentile curves. These differences in radiation exposure were observed without changes in median fluoroscopy time. CONCLUSIONS: This study updates previously established benchmarks to reflect QI efforts over time. These thresholds can be applied for quality measurement and comparison. © 2017 Wiley Periodicals, Inc.


Assuntos
Benchmarking/normas , Cateterismo Cardíaco/normas , Cardiopatias Congênitas/terapia , Pediatria/normas , Doses de Radiação , Exposição à Radiação/normas , Radiografia Intervencionista/normas , Adolescente , Fatores Etários , Cateterismo Cardíaco/efeitos adversos , Criança , Pré-Escolar , Feminino , Cardiopatias Congênitas/diagnóstico por imagem , Humanos , Lactente , Masculino , Segurança do Paciente/normas , Estudos Prospectivos , Exposição à Radiação/efeitos adversos , Exposição à Radiação/prevenção & controle , Radiografia Intervencionista/efeitos adversos , Sistema de Registros , Medição de Risco , Fatores de Risco , Estados Unidos
9.
JACC Cardiovasc Interv ; 7(9): 1060-9, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25234681

RESUMO

OBJECTIVES: The aim of this study was to define age-stratified, procedure-specific benchmark radiation dose levels during interventional catheterization for congenital heart disease. BACKGROUND: There is a paucity of published literature with regard to radiation dose levels during catheterization for congenital heart disease. Obtaining benchmark radiation data is essential for assessing the impact of quality improvement initiatives for radiation safety. METHODS: Data were obtained retrospectively from 7 laboratories participating in the Congenital Cardiac Catheterization Project on Outcomes collaborative. Total air kerma, dose area product, and total fluoroscopy time were obtained for the following procedures: 1) patent ductus arteriosus closure; 2) atrial septal defect closure; 3) pulmonary valvuloplasty; 4) aortic valvuloplasty; 5) treatment of coarctation of aorta; and 6) transcatheter pulmonary valve placement. RESULTS: Between January 2009 and July 2013, 2,713 cases were identified. Radiation dose benchmarks are presented including median, 75th percentile, and 95th percentile. Radiation doses varied widely between age groups and procedure types. Radiation exposure was lowest in patent ductus arteriosus closure and highest in transcatheter pulmonary valve placement. Total fluoroscopy time was a poor marker of radiation exposure and did not correlate well with total air kerma and dose area product. CONCLUSIONS: This study presents age-stratified radiation dose values for 6 common congenital heart interventional catheterization procedures. Fluoroscopy time alone is not an adequate measure for monitoring radiation exposure. These values will be used as baseline for measuring the effectiveness of future quality improvement activities by the Congenital Cardiac Catheterization Project on Outcomes collaborative.


Assuntos
Benchmarking/normas , Cateterismo Cardíaco/normas , Cardiopatias Congênitas/diagnóstico por imagem , Cardiopatias Congênitas/terapia , Doses de Radiação , Radiografia Intervencionista/normas , Adolescente , Fatores Etários , Cateterismo Cardíaco/efeitos adversos , Criança , Pré-Escolar , Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Segurança do Paciente/normas , Guias de Prática Clínica como Assunto/normas , Valor Preditivo dos Testes , Lesões por Radiação/etiologia , Lesões por Radiação/prevenção & controle , Radiografia Intervencionista/efeitos adversos , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Estados Unidos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA