1.
PLoS One ; 11(3): e0152152, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27011312

RESUMO

OBJECTIVES: To evaluate sources of error in the Magnetic Resonance Imaging (MRI) measurement of percent fibroglandular tissue (%FGT) using two-point Dixon sequences for fat-water separation. METHODS: Ten female volunteers (median age: 31 yrs, range: 23-50 yrs) gave informed consent following Research Ethics Committee approval. Each volunteer was scanned twice following repositioning to enable an estimation of measurement repeatability from high-resolution gradient-echo (GRE) proton-density (PD)-weighted Dixon sequences. Differences in measures of %FGT attributable to resolution, T1 weighting and sequence type were assessed by comparison of this Dixon sequence with low-resolution GRE PD-weighted Dixon data, and against gradient-echo (GRE) or spin-echo (SE) based T1-weighted Dixon datasets, respectively. RESULTS: %FGT measurement from high-resolution PD-weighted Dixon sequences had a coefficient of repeatability of ±4.3%. There was no significant difference in %FGT between high-resolution and low-resolution PD-weighted data. Values of %FGT from GRE and SE T1-weighted data were strongly correlated with that derived from PD-weighted data (r = 0.995 and 0.96, respectively). However, both sequences exhibited higher mean %FGT by 2.9% (p < 0.0001) and 12.6% (p < 0.0001), respectively, in comparison with PD-weighted data; the increase in %FGT from the SE T1-weighted sequence was significantly larger at lower breast densities. CONCLUSION: Although measurement of %FGT at low resolution is feasible, T1 weighting and sequence type impact on the accuracy of Dixon-based %FGT measurements; Dixon MRI protocols for %FGT measurement should be carefully considered, particularly for longitudinal or multi-centre studies.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Mamografia/métodos , Adulto , Mama/patologia , Neoplasias da Mama/patologia , Feminino , Humanos , Pessoa de Meia-Idade
2.
AJR Am J Roentgenol ; 204(2): W141-9, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25615774

RESUMO

OBJECTIVE. The purpose of this article is to review the use of MRI in breast density measurement and breast cancer risk estimation and to discuss the role of MRI as an alternative screening to mammography for screening women with dense breasts. CONCLUSION. The potential of MRI for screening women with dense breasts remains controversial because of the paucity of clinical evidence, the possibility of overdiagnosis, and the cost-effectiveness of the technique in this population. Although methods of MRI measurement require standardization and automation, future addition of MRI density to risk models may positively impact their value.


Assuntos
Neoplasias da Mama/diagnóstico , Mama/patologia , Detecção Precoce de Câncer/métodos , Imageamento por Ressonância Magnética , Feminino , Humanos
3.
Acad Radiol ; 21(11): 1394-401, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25179563

RESUMO

RATIONALE AND OBJECTIVES: To retrospectively investigate the effect of flip angle (FA) and k-space sampling on the performance of dynamic contrast-enhanced (DCE-) magnetic resonance imaging (MRI) breast sequences. MATERIALS AND METHODS: Five DCE-MRI breast sequences were evaluated (10°, 14°, and 18° FAs; radial or linear k-space sampling), with 7-10 patients in each group (n = 45). All sequences were compliant with current technical breast screening guidelines. Contrast agent (CA) uptake curves were constructed from the right mammary artery for each examination. Maximum relative enhancement, E(max), and time-to-peak enhancement, T(max), were measured and compared between protocols (analysis of variance and Mann-Whitney). For each sequence, calculated values of maximum relative enhancement, E(calc), were derived from the Bloch equations and compared to E(max). Fat suppression performance (residual bright fat and chemical shift artifact) was rated for each examination and compared between sequences (Fisher exact tests). RESULTS: Significant differences were identified between DCE-MRI sequences. E(max) increased significantly at higher FAs and with linear k-space sampling (P < .0001; P = .001). Radial protocols exhibited greater T(max) than linear protocols at FAs of both 14° (P = .025) and 18° (P < .0001), suggesting artificially flattened uptake curves. Good correlation was observed between E(calc) and E(max) (r = 0.86). Fat suppression failure was more pronounced at an FA of 18° (P = .008). CONCLUSIONS: This retrospective approach is validated as a tool to compare and optimize breast DCE-MRI sequences. Alterations in FA and k-space sampling result in significant differences in CA uptake curve shape which could potentially affect diagnostic interpretation. These results emphasize the need for careful parameter selection and greater standardization of breast DCE-MRI sequences.


Assuntos
Algoritmos , Neoplasias da Mama/patologia , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Meglumina , Compostos Organometálicos , Processamento de Sinais Assistido por Computador , Meios de Contraste , Feminino , Humanos , Aumento da Imagem/métodos , Reprodutibilidade dos Testes , Tamanho da Amostra , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA