Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 111
Filtrar
1.
Quant Imaging Med Surg ; 14(5): 3432-3446, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38720859

RESUMO

Background: Image-based assessment of prostate cancer (PCa) is increasingly emphasized in the diagnostic workflow for selecting biopsy targets and possibly predicting clinically significant prostate cancer (csPCa). Assessment is based on Prostate Imaging-Reporting and Data System (PI-RADS) which is largely dependent on T2-weighted image (T2WI) and diffusion weighted image (DWI). This study aims to determine whether deep learning reconstruction (DLR) can improve the image quality of DWI and affect the assessment of PI-RADS ≥4 in patients with PCa. Methods: In this retrospective study, 3.0T post-biopsy prostate magnetic resonance imaging (MRI) of 70 patients with PCa in Korea University Ansan Hospital from November 2021 to July 2022 was reconstructed with and without using DLR. Four DWI image sets were made: (I) conventional DWI (CDWI): DWI with acceleration factor 2 and conventional parallel imaging reconstruction, (II) DL1: DWI with acceleration factor 2 using DLR, (III) DL2: DWI with acceleration factor 3 using DLR, and (IV) DL3: DWI with acceleration factor 3 and half average b-value using DLR. Apparent diffusion coefficient (ADC) value, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) were measured by one reviewer, while two reviewers independently assessed overall image quality, noise, and lesion conspicuity using a four-point visual scoring system from each DWI image set. Two reviewers also performed PI-RADSv2.1 scoring on lesions suspected of malignancy. Results: A total of 70 patients (mean age, 70.8±9.7 years) were analyzed. The image acquisition time was 4:46 min for CDWI and DL1, 3:40 min for DL2, and 2:00 min for DL3. DL1 and DL2 images resulted in better lesion conspicuity compared to CDWI images assessed by both readers (P<0.05). DLR resulted in a significant increase in SNR, from 38.4±14.7 in CDWI to 56.9±21.0 in DL1. CNR increased from 25.1±11.5 in CDWI to 43.1±17.8 in DL1 (P<0.001). PI-RADS v2.1 scoring for PCa lesions was more agreeable with the DL1 reconstruction method than with CDWI (κ value CDWI, DL1; 0.40, 0.61, respectively). A statistically significant number of lesions were upgraded from PI-RADS <4 in CDWI image to PI-RADS ≥4 in DL1 images for both readers (P<0.05). Most of the PI-RADS upgraded lesions were from higher than unfavorable intermediate-risk groups according to the 2023 National Comprehensive Cancer Network guidelines with statistically significant difference of marginal probability in DL1 and DL2 for both readers (P<0.05). Conclusions: DLR in DWI for PCa can provide options for improving image quality with a significant impact on PI-RADS evaluation or about a 23% reduction in acquisition time without compromising image quality.

2.
J Korean Soc Radiol ; 85(2): 445-450, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38617873

RESUMO

Gastric metastasis (GM) from cervical cancer is extremely rare, and only a few cases have been reported in the English literature. Gastric-type mucinous adenocarcinomas (GAS) of the uterine cervix are rare. GAS is an aggressive cancer commonly found in advanced stages; however, GM has not been reported. This study presents a rare case of GM from GAS of the uterine cervix in a 61-year-old female and describes the radiological findings of both the GM and cervical mucinous adenocarcinoma. GM appeared as a poor enhancing submucosal mass. The cervical mucinous adenocarcinoma appeared as an infiltrating mass with poor contrast enhancement. It exhibited mildly high and low signal intensities on the diffusion-weighted image and apparent diffusion coefficient map, respectively. This case is extremely rare and challenging to diagnose; however, if cervical cancer is an human papillomavirus-independent GAS type and a submucosal lesion is found in the stomach, the possibility of metastasis with a pattern similar to our case could be considered.

3.
J Hepatol ; 2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38636849

RESUMO

BACKGROUND & AIMS: Ultrasonography (US) is recommended for HCC surveillance in high-risk patients but has limited performance in detecting early-stage HCC. We aimed to compare the diagnostic performance of biannual US and annual non-contrast abbreviated magnetic resonance imaging (NC-AMRI) as HCC surveillance modalities in high-risk patients. METHODS: This prospective, multicenter cohort study enrolled participants with an estimated annual risk of HCC greater than 5% between October 2015 and April 2017. Participants underwent six rounds of HCC surveillance at 6-month intervals, with both US and NC-AMRI at rounds 1, 3, and 5, and only US at rounds 2, 4, and 6. The sensitivity, diagnostic yield (DY), and false referral rate (FRR) for HCC detection by US and NC-AMRI were compared. RESULTS: In total, 208 participants underwent 980 US and 516 NC-AMRI examinations during 30 months of follow-up. Among them, 34 HCCs were diagnosed in 31 participants, with 20 (64.5%) classified as very early-stage and 11 (35.5%) as early-stage HCC. The sensitivity of annual NC-AMRI (71.0%, 22/31) was marginally higher than that of biannual US (45.2%, 14/31; p = 0.077). NC-AMRI showed a significantly higher DY than US (4.26% vs. 1.43%, p <0.001), with a similar FRR (2.91% vs. 3.06%, p = 0.885). A simulation of alternating US and NC-AMRI at 6-month intervals yielded a sensitivity of 83.9% (26/31), significantly exceeding that of biannual US (p = 0.006). CONCLUSIONS: Annual NC-AMRI showed a marginally higher sensitivity than biannual US for HCC detection in high-risk patients. The DY of annual NC-AMRI was significantly higher than that of biannual US, without increasing the FRR. Thus, alternating US and NC-AMRI at 6-month intervals could be an optimal surveillance strategy for high-risk patients. IMPACT AND IMPLICATIONS: Current guidelines permit the use of magnetic resonance imaging (MRI) as a surveillance tool for hepatocellular carcinoma in patients in whom ultrasonography (US) is inadequate. However, the specific indications, imaging sequences, and intervals for MRI surveillance remain unclear. In our study, we found that annual non-contrast abbreviated MRI exhibited marginally higher sensitivity and significantly better diagnostic yield than biannual US in patients at high risk of hepatocellular carcinoma. Alternating US and non-contrast abbreviated MRI at 6-month intervals led to significantly improved sensitivity compared to biannual US, making it a potentially optimal surveillance strategy for high-risk patients. GOV IDENTIFIER: NCT02551250.

4.
Radiology ; 311(1): e233114, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38563667

RESUMO

Background Noninvasive diagnostic guidelines for hepatocellular carcinoma (HCC) vary across different global geographic areas, especially regarding criteria about gadoxetic acid-enhanced MRI. Purpose To compare the diagnostic performance of four different international HCC diagnosis guidelines and readers' judgment in diagnosing HCC using gadoxetic acid-enhanced MRI in patients at high risk for HCC. Materials and Methods This retrospective study included patients who had not undergone treatment, were at risk for HCC, and who underwent gadoxetic acid-enhanced MRI from January 2015 to June 2018 from 11 tertiary hospitals in South Korea. Four radiologists independently reviewed focal liver lesions (FLLs) according to four guidelines: American Association for the Study of Liver Diseases (AASLD)/Liver Imaging Reporting and Data System (LI-RADS), Korean Liver Cancer Association-National Cancer Center (KLCA-NCC), European Association for the Study of the Liver (EASL), and Asian Pacific Association for the Study of the Liver (APASL). Reader judgment (HCC or not HCC) was also recorded. Malignant FLLs were confirmed at pathology, and histologic and clinical follow-up data were used for benign FLLs. The guidelines' diagnostic performance was compared using generalized estimating equations. Additionally, the diagnostic odds ratio was assessed. Results A total of 2445 FLLs (median size, 27.4 mm) were analyzed in 2237 patients (mean age, 59 years ± 11 [SD]; 1666 male patients); 69.3% (1694 of 2445) were HCCs. KLCA-NCC showed the highest accuracy (80.0%; 95% CI: 78.7, 81.2; P = .001), with high sensitivity in Eastern guidelines (APASL, 89.1% [95% CI: 87.8, 90.3]; KLCA-NCC, 78.2% [95% CI: 76.6, 79.7]) and high specificity in Western guidelines (AASLD/LI-RADS, 89.6% [95% CI: 87.8, 91.2]; EASL, 88.1% [95% CI: 86.2, 89.9]) (P = .001). The diagnostic odds ratios were 20.7 (95% CI: 17.0, 25.3) for AASLD/LI-RADS, 18.9 (95% CI: 15.8, 22.6) for KLCA-NCC, 16.8 (95% CI: 13.8, 20.4) for EASL, and 8.9 (95% CI: 7.4, 10.7) for APASL. The readers' judgment demonstrated higher accuracy than that of the guidelines (accuracy, 86.0%; 95% CI: 84.9, 86.9; P = .001). Conclusion Among four different international HCC diagnosis guidelines, Eastern guidelines demonstrated higher sensitivity, whereas Western guidelines displayed higher specificity. KLCA-NCC achieved the highest accuracy, and AASLD/LI-RADS exhibited the highest diagnostic odds ratio. © RSNA, 2024 Supplemental material is available for this article.


Assuntos
Carcinoma Hepatocelular , Gadolínio DTPA , Neoplasias Hepáticas , Humanos , Masculino , Pessoa de Meia-Idade , Carcinoma Hepatocelular/diagnóstico por imagem , Estudos Retrospectivos , Neoplasias Hepáticas/diagnóstico por imagem , Imageamento por Ressonância Magnética
5.
Chem Sci ; 15(2): 555-565, 2024 Jan 03.
Artigo em Inglês | MEDLINE | ID: mdl-38179521

RESUMO

The epidermal growth factor receptor (EGFR) is a cell-surface glycoprotein that is involved mainly in cell proliferation. Overexpression of this receptor is intimately related to the development of a broad spectrum of tumors. In addition, glycans linked to the EGFR are known to affect its EGF-induced activation. Because of the pathophysiological significance of the EGFR, we prepared a fluorescently labeled EGFR (EGFR128-AZDye 488) on the cell surface by employing the genetic code expansion technique and bioorthogonal chemistry. EGFR128-AZDye 488 was initially utilized to investigate time-dependent endocytosis of the EGFR in live cells. The results showed that an EGFR inhibitor and antibody suppress endocytosis of the EGFR promoted by the EGF, and that lectins recognizing glycans of the EGFR do not enhance EGFR internalization into cells. Observations made in studies of the effects of appended glycans on the entry of the EGFR into cells indicate that a de-sialylated or de-fucosylated EGFR is internalized into cells more efficiently than a wild-type EGFR. Furthermore, by using the FRET-based imaging method of cells which contain an EGFR linked to AZDye 488 (a FRET donor) and cellular glycans labeled with rhodamine (a FRET acceptor), sialic acid residues attached to the EGFR were specifically detected on the live cell surface. Taken together, the results suggest that a fluorescently labeled EGFR will be a valuable tool in studies aimed at gaining an understanding of cellular functions of the EGFR.

6.
Radiol Artif Intell ; 6(2): e230192, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38231025

RESUMO

Purpose To compare the image quality and diagnostic capability in detecting malignant liver tumors of low-dose CT (LDCT, 33% dose) with deep learning-based denoising (DLD) and standard-dose CT (SDCT, 100% dose) with model-based iterative reconstruction (MBIR). Materials and Methods In this prospective, multicenter, noninferiority study, individuals referred for liver CT scans were enrolled from three tertiary referral hospitals between February 2021 and August 2022. All liver CT scans were conducted using a dual-source scanner with the dose split into tubes A (67% dose) and B (33% dose). Blended images from tubes A and B were created using MBIR to produce SDCT images, whereas LDCT images used data from tube B and were reconstructed with DLD. The noise in liver images was measured and compared between imaging techniques. The diagnostic performance of each technique in detecting malignant liver tumors was evaluated by three independent radiologists using jackknife alternative free-response receiver operating characteristic analysis. Noninferiority of LDCT compared with SDCT was declared when the lower limit of the 95% CI for the difference in figure of merit (FOM) was greater than -0.10. Results A total of 296 participants (196 men, 100 women; mean age, 60.5 years ± 13.3 [SD]) were included. The mean noise level in the liver was significantly lower for LDCT (10.1) compared with SDCT (10.7) (P < .001). Diagnostic performance was assessed in 246 participants (108 malignant tumors in 90 participants). The reader-averaged FOM was 0.880 for SDCT and 0.875 for LDCT (P = .35). The difference fell within the noninferiority margin (difference, -0.005 [95% CI: -0.024, 0.012]). Conclusion Compared with SDCT with MBIR, LDCT using 33% of the standard radiation dose had reduced image noise and comparable diagnostic performance in detecting malignant liver tumors. Keywords: CT, Abdomen/GI, Liver, Comparative Studies, Diagnosis, Reconstruction Algorithms Clinical trial registration no. NCT05804799 © RSNA, 2024 Supplemental material is available for this article.


Assuntos
Carcinoma Hepatocelular , Aprendizado Profundo , Neoplasias Hepáticas , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Abdome , Estudos Prospectivos , Doses de Radiação , Tomografia Computadorizada por Raios X/métodos , Idoso
7.
Cancer Imaging ; 23(1): 126, 2023 Dec 18.
Artigo em Inglês | MEDLINE | ID: mdl-38111054

RESUMO

OBJECTIVES: To assess the resectability of pancreatic ductal adenocarcinoma (PDAC), the evaluation of tumor vascular contact holds paramount significance. This study aimed to compare the image quality and diagnostic performance of high-resolution (HR) pancreas computed tomography (CT) using an 80 kVp tube voltage and a thin slice (1 mm) for assessing PDAC resectability, in comparison with the standard protocol CT using 120 kVp. METHODS: This research constitutes a secondary analysis originating from a multicenter prospective study. All participants underwent both the standard protocol pancreas CT using 120 kVp with 3 mm slice thickness (ST) and HR-CT utilizing an 80 kVp tube voltage and 1 mm ST. The contrast-to-noise ratio (CNR) between parenchyma and tumor, along with the degree of enhancement of the abdominal aorta and main portal vein (MPV), were measured and subsequently compared. Additionally, the likelihood of margin-negative resection (R0) was evaluated using a five-point scale. The diagnostic performance of both CT protocols in predicting R0 resection was assessed through the area under the receiver operating characteristic curve (AUC). RESULTS: A total of 69 patients (37 males and 32 females; median age, 66.5 years) were included in the study. The median CNR of PDAC was 10.4 in HR-CT, which was significantly higher than the 7.1 in the standard CT (P=0.006). Furthermore, HR-CT demonstrated notably higher median attenuation values for both the abdominal aorta (579.5 HU vs. 327.2 HU; P=0.002) and the MPV (263.0 HU vs. 175.6 HU; P=0.004) in comparison with standard CT. Following surgery, R0 resection was achieved in 51 patients. The pooled AUC for HR-CT in predicting R0 resection was 0.727, slightly exceeding the 0.699 of standard CT, albeit lacking a significant statistical distinction (P=0.128). CONCLUSION: While HR pancreas CT using 80 kVp offered a notably greater degree of contrast enhancement in vessels and a higher CNR for PDAC compared to standard CT, its diagnostic performance in predicting R0 resection remained statistically comparable.


Assuntos
Carcinoma Ductal Pancreático , Neoplasias Pancreáticas , Idoso , Feminino , Humanos , Masculino , Carcinoma Ductal Pancreático/diagnóstico por imagem , Carcinoma Ductal Pancreático/cirurgia , Meios de Contraste , Pâncreas/diagnóstico por imagem , Pâncreas/cirurgia , Pâncreas/patologia , Neoplasias Pancreáticas/diagnóstico por imagem , Neoplasias Pancreáticas/cirurgia , Neoplasias Pancreáticas/patologia , Estudos Prospectivos , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Estudos Multicêntricos como Assunto
8.
J Korean Soc Radiol ; 84(3): 698-704, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-37324981

RESUMO

According to the 2020 World Health Organization classification, mesonephric-like adenocarcinoma (MLA) is newly categorized as a subtype of endometrial carcinoma and remains a relatively unknown disease owing to its rarity. To the best of our knowledge, radiological findings of MLA have not been reported in the English literature. The uterine MLAs show a worse clinical prognosis and a more aggressive biological behavior than the usual endometrial carcinoma. Herein, we present the imaging findings of a 65-year-old female with a MLA in the uterine corpus. The tumor was a solid endometrial mass with deep myometrial invasion, poor contrast enhancement, and moderate diffusion restriction.

9.
Eur Radiol ; 33(9): 5965-5975, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-36988715

RESUMO

OBJECTIVE: This prospective multicenter study aimed to evaluate the diagnostic performance of 80-kVp thin-section pancreatic CT in determining pancreatic ductal adenocarcinoma (PDAC) resectability according to the recent National Comprehensive Cancer Network (NCCN) guidelines. METHODS: We prospectively enrolled surgical resection candidates for PDAC from six tertiary referral hospitals (study identifier: NCT03895177). All participants underwent pancreatic CT using 80 kVp tube voltage with 1-mm reconstruction interval. The local resectability was prospectively evaluated using NCCN guidelines at each center and classified into three categories: resectable, borderline resectable, and unresectable. RESULTS: A total of 138 patients were enrolled; among them, 60 patients underwent neoadjuvant therapy. R0 resection was achieved in 103 patients (74.6%). The R0 resection rates were 88.7% (47/53), 52.4% (11/21), and 0.0% (0/4) for resectable, borderline resectable, and unresectable disease, respectively, in 78 patients who underwent upfront surgery. Meanwhile, the rates were 90.9% (20/22), 76.7% (23/30), and 25.0% (2/8) for resectable, borderline resectable, and unresectable PDAC, respectively, in patients who received neoadjuvant therapy. The area under curve of high-resolution CT in predicting R0 resection was 0.784, with sensitivity, specificity, and accuracy of 87.4% (90/103), 48.6% (17/35), and 77.5% (107/138), respectively. Tumor response was significantly associated with the R0 resection after neoadjuvant therapy (odds ratio [OR] = 38.99, p = 0.016). CONCLUSION: An 80-kVp thin-section pancreatic CT has excellent diagnostic performance in assessing PDAC resectability, enabling R0 resection rates of 88.7% and 90.9% for patients with resectable PDAC who underwent upfront surgery and patients with resectable PDAC after neoadjuvant therapy, respectively. KEY POINTS: • The margin-negative (R0) resection rates were 88.7% (47/53), 52.4% (11/21), and 0.0% (0/4) for resectable, borderline resectable, and unresectable pancreatic ductal adenocarcinoma (PDAC), respectively, on 80-kVp thin-section pancreatic CT in the 78 patients who underwent upfront surgery. • Among the 60 patients who underwent neoadjuvant therapy, the R0 rates were 90.9% (20/22), 76.7% (23/30), and 25.0% (2/8) for resectable, borderline resectable, and unresectable PDAC, respectively. • Tumor response, along with the resectability status on pancreatic CT, was significantly associated with the R0 resection rate after neoadjuvant therapy.


Assuntos
Carcinoma Ductal Pancreático , Neoplasias Pancreáticas , Humanos , Estudos Prospectivos , Neoplasias Pancreáticas/diagnóstico por imagem , Neoplasias Pancreáticas/cirurgia , Neoplasias Pancreáticas/patologia , Carcinoma Ductal Pancreático/diagnóstico por imagem , Carcinoma Ductal Pancreático/cirurgia , Carcinoma Ductal Pancreático/patologia , Tomografia Computadorizada por Raios X/métodos , Terapia Neoadjuvante , Neoplasias Pancreáticas
10.
Eur Radiol ; 33(6): 4401-4411, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36562784

RESUMO

OBJECTIVES: To evaluate the feasibility of simulated abbreviated MRI (AMRI) with second shot arterial phase (SSAP) for HCC surveillance and diagnosis. METHODS: A total of 129 consecutive patients (age, 58.8 ± 11.4 years; male, 71.3%) underwent gadoxetic acid-enhanced MRI using a modified injection protocol for HCC evaluation from July 2017 to February 2018. The modified injection protocol consisted of routine dynamic imaging (6 mL) and SSAP imaging (4 mL). Two radiologists independently reviewed two AMRI sets: AMRI without SSAP (surveillance set) and AMRI with SSAP (diagnosis set). A modified version of the Liver Imaging Reporting and Data System (LI-RADS) for the diagnosis set was devised by referring to contrast-enhanced ultrasound LI-RADS. RESULTS: Sixty-seven patients with HCC and 62 patients without HCC were included. In the surveillance set, sensitivity and specificity for the detection of patients with HCC were 95.5% and 96.8%, and 94.0% and 96.8% in reviewers 1 and 2, respectively. In the diagnosis set, the scores of most HCCs (76/78, 97.4%) were consistent between LI-RADS of full-protocol and modified LI-RADS of AMRI with SSAP protocol. When the HCC surveillance and diagnosis strategy was changed from strategy 1 (AMRI without SSAP) to strategy 2 (AMRI with SSAP), the recall rate significantly decreased from 52.7 to 3.9% (p < 0.001). CONCLUSIONS: The modified LI-RADS score of the AMRI with SSAP protocol showed high agreement with the LI-RADS score of the full protocol. The HCC surveillance and diagnosis strategy using the AMRI with SSAP protocol reduced the recall rate. These results may enable to diagnose HCC simultaneously with surveillance. KEY POINTS: • A modified version of LI-RADS was devised for the diagnostic algorithm using AMRI with the second shot arterial phase (SSAP) by referring to CEUS LI-RADS. • The modified LI-RADS scores using AMRI with SSAP showed a high concordance rate with the conventional LI-RADS score using full-protocol MRI. • The recall rate significantly decreased when the HCC surveillance and diagnosis strategy was changed from strategy 1 (AMRI without SSAP; surveillance then recall test) to strategy 2 (AMRI with SSAP; simultaneous surveillance and diagnosis).


Assuntos
Carcinoma Hepatocelular , Neoplasias Hepáticas , Humanos , Masculino , Pessoa de Meia-Idade , Idoso , Carcinoma Hepatocelular/diagnóstico por imagem , Neoplasias Hepáticas/diagnóstico por imagem , Meios de Contraste/farmacologia , Estudos Retrospectivos , Gadolínio DTPA , Imageamento por Ressonância Magnética/métodos , Sensibilidade e Especificidade
11.
Chem Sci ; 13(43): 12738-12746, 2022 Nov 09.
Artigo em Inglês | MEDLINE | ID: mdl-36519038

RESUMO

Phototherapy has been a promising therapeutic modality for pathological tissue due to its spatiotemporal selectivity and non-invasive characteristics. However, as a core component of phototherapy, a single photosensitizer (PS) nanoplatform integrating excellent therapeutic efficiency and minimal side effects remains an urgent but unmet need. Here, we construct a J-aggregated nano-porphyrin termed MTE based on the self-assembly of methyl-pheophorbide a derivative MPa-TEG (MT) and natural polyphenolic compound epigallocatechin gallate (EGCG). Due to the synergistic interaction between similar large π-conjugated structural EGCG and MT, MTE with small and uniform size is obtained by effectively hindering Ostwald ripening of MT. Noteworthily, MTE not only effectively avoids the inadvertent side effects of phototoxicity during transport thank to the ability of reactive oxygen species (ROS) scavenging, but also achieves two-pathway augmented superior phototherapy: (1) enhancing photodynamic therapy (PDT) via inhibiting the expression of anti-apoptosis protein surviving; (2) achieving adjuvant mild-temperature laser interstitial thermal therapy (LITT) via reducing the tumor thermoresistance on account that MTE inhibits the overexpression of HSP 70 and HSP 90. This research not only offers a facile strategy to construct multicomponent nanoplatforms but also provides a new pathway for efficient and low-toxicity phototherapy, which is beneficial to the future clinical application.

12.
Quant Imaging Med Surg ; 12(11): 5251-5262, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36330193

RESUMO

Background: The grade of hepatic steatosis is assessed semi-quantitatively and graded as a discrete value. However, the proton density fat fraction (PDFF) measured by magnetic resonance imaging (MRI) and FF measured by MR spectroscopy (FFMRS) are continuous values. Therefore, a quantitative histopathologic method may be needed. This study aimed to (I) provide a spectrum of values of MRI-PDFF, FFMRS, and FFs measured by two different histopathologic methods [artificial intelligence (AI) and pathologist], (II) to evaluate the correlation among them, and (III) to evaluate the diagnostic performance of MRI-PDFF and MRS for grading hepatic steatosis. Methods: Forty-seven patients who underwent liver biopsy and MRI for nonalcoholic steatohepatitis (NASH) evaluation were included. The agreement between MRI-PDFF and MRS was evaluated through Bland-Altman analysis. Correlations among MRI-PDFF, MRS, and two different histopathologic methods were assessed using Pearson correlation coefficient (r). The diagnostic performance of MRI-PDFF and MRS was assessed using receiver operating characteristic curve analyses and the area under the curve (AUC) were obtained. Results: The means±standard deviation of MRI-PDFF, FFMRS, FF measured by pathologist (FFpathologist), and FF measured by AI (FFAI) were 12.04±6.37, 14.01±6.16, 34.26±19.69, and 6.79±4.37 (%), respectively. Bland-Altman bias [mean of MRS - (MRI-PDFF) differences] was 2.06%. MRI-PDFF and MRS had a very strong correlation (r=0.983, P<0.001). The two different histopathologic methods also showed a very strong correlation (r=0.872, P<0.001). Both MRI-PDFF and MRS demonstrated a strong correlation with FFpathologist (r=0.701, P<0.001 and r=0.709, P<0.001, respectively) and with FFAI (r=0.700, P<0.001 and r=0.690, P<0.001, respectively). The AUCs of MRI-PDFF for grading ≥S2 and ≥S3 were 0.846 and 0.855, respectively. The AUCs of MRS for grading ≥S2 and ≥S3 were 0.860 and 0.878, respectively. Conclusions: Since MRS and MRI-PDFF demonstrated a strong correlation with each other and with the two different histopathologic methods, they can be used as an alternative noninvasive reference standard in nonalcoholic fatty liver disease (NAFLD) patients. However, these preliminary results should be interpreted with caution until they are validated in further studies.

13.
RSC Adv ; 12(35): 22435-22439, 2022 Aug 10.
Artigo em Inglês | MEDLINE | ID: mdl-36105987

RESUMO

We describe fluorescent probes to detect formaldehyde (FA) in aqueous solutions and cells. The probes rapidly respond to FA in aqueous solutions and have great selectivity toward FA over other biologically relevant analytes. The results of cell studies reveal that probe 1 can be utilized to monitor endogenous and exogenous FA in live cells.

14.
Food Sci Anim Resour ; 42(5): 903-914, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-36133633

RESUMO

Probiotics are currently considered as one of tools to modulate immune responses under specific clinical conditions. The purpose of this study was to evaluate whether oral administration of three different probiotics (Lactiplantibacillus plantarum CJLP243, CJW55-10, and CJLP475) could evoke a cell-mediated immunity in immunodeficient mice. Before conducting in vivo experiments, we examined the in vitro potency of these probiotics for macrophage activation. After co-culture with these probiotics, bone marrow derived macrophages (BMDMs) produced significant amounts of proinflammatory cytokines including interleukin-6 (IL-6), IL-12, and tumor necrosis factor-α (TNF-α). Levels of inducible nitric oxide synthase (inos) and co-stimulatory molecules (CD80 and CD86) were also upregulated in BMDMs after treatment with some of these probiotics. To establish an immunocompromised animal model, we intraperitoneally injected mice with cyclophosphamide on day 0 and again on day 2. Starting day 3, we orally administered probiotics every day for the last 15 d. After sacrificing experimental mice on day 18, splenocytes were isolated and co-cultured with these probiotics for 3 d to measure levels of several cytokines and immune cell proliferation. Results clearly indicated that the consumption of all three probiotic strains promoted secretion of interferon-γ (IFN-γ), IL-1ß, IL-6, IL-12, and TNF-α. NK cell cytotoxicity and proliferation of immune cells were also increased. Taken together, our data strongly suggest that consumption of some probiotics might induce cell-mediated immune responses in immunocompromised mice.

15.
Abdom Radiol (NY) ; 47(6): 2254-2276, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35441342

RESUMO

Various ectopic lesions occur in the abdomen and pelvis and affect multiple organs including liver, gallbladder, pancreas, spleen, and organs of the genitourinary system. Ectopic organs may be present outside their normal positions, or ectopic tissues may develop while the original organ exists in its normal position. Both benign and malignant lesions can occur in ectopic organs and tissues. Owing to their unusual location, they can often be misdiagnosed as other lesions or even malignant lesions, such as metastasis or seeding. This multimodality pictorial review provides various cases of ectopic lesions in the abdomen and pelvis, which will help narrow the differential diagnosis and guide clinical decision-making.


Assuntos
Abdome , Neoplasias , Abdome/diagnóstico por imagem , Abdome/patologia , Humanos , Imagem Multimodal , Neoplasias/patologia , Pelve/diagnóstico por imagem , Baço
16.
Quant Imaging Med Surg ; 12(3): 1815-1829, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35284276

RESUMO

Background: Liver biopsy is a gold standard for the diagnosis of non-alcoholic steatohepatitis (NASH), but has several disadvantages including invasiveness, high cost, and sampling error. Ultrasonography (US) is a noninvasive imaging modality widely used in non-alcoholic fatty liver disease (NAFLD) patients. This study aimed: (I) to assess the feasibility of US in the prediction of NASH and (II) to develop various US indices combining US parameters and laboratory data for the detection of NASH in NAFLD patients and to compare the diagnostic performance of them. Methods: Sixty patients who underwent liver biopsy, gray-scale US [hepatorenal index (HRI) and shear-wave elastography (SWE)], and Fibroscan [controlled attenuation parameter (CAP) and transient elastography (TE)] for the evaluation of NASH were included. Patients were classified according to the NAFLD Activity Score (NAS) into the NASH (NAS ≥5) and non-NASH (NAS <5) groups. The diagnostic performance of HRI, CAP, SWE, TE, and laboratory data for grading steatosis, lobular inflammation, ballooning degeneration, and fibrosis was evaluated. After the identification of laboratory data that were independently associated with NASH through univariable and multivariable logistic regression analyses, various US indices were developed by combining US parameters with or without these laboratory data. The diagnostic performance of the US indices was assessed with obtaining area under the curve (AUC) and compared using DeLong test. Results: Twenty-five NASH and 35 non-NASH patients were included. The mean AUCs for grading steatosis were 0.871 using HRI and 0.583 using CAP. The mean AUCs for grading fibrosis and ballooning degeneration were 0.777 and 0.729 using SWE and 0.830 and 0.708 using TE, respectively. Aspartate aminotransferase (AST) was the only significant laboratory data associated with NASH (OR, 1.019; P=0.032). Using AST, the mean AUCs for grading lobular inflammation and ballooning degeneration were 0.712 and 0.775, respectively. Among various US indices, the index consisting of gray-scale US parameters (SWE and HRI) and AST showed the best diagnostic performance for the detection of NASH in NAFLD patients (AUC =0.806). Conclusions: The index combining gray-scale US parameters and AST is useful for the detection of NASH and may be used to exclude the need for liver biopsy in NAFLD patients.

17.
Ultrasonography ; 41(2): 416-429, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35045593

RESUMO

Ultrasonography (US) is widely used for abdominal imaging. Its noninvasiveness, extensive range of application, and low cost make US a useful and valuable tool for the detection, diagnosis, and follow-up of splenic abnormalities. Concomitantly with the increasing frequency of imaging, more splenic lesions are being discovered and the requirements for the differential diagnosis are rising. In this pictorial essay, we introduce the representative US findings of many different splenic lesions, including normal sonographic findings, normal variants and congenital anomalies, infectious conditions, benign and malignant neoplasms, and non-neoplastic lesions. Knowledge of the US features of various splenic lesions will help narrow the differential diagnosis and guide clinical decision-making.

18.
J Mater Chem B ; 9(48): 9946-9950, 2021 12 15.
Artigo em Inglês | MEDLINE | ID: mdl-34852032

RESUMO

Fluorescence imaging agents have recently received huge attention due to their important role in disease diagnostics. However, the intrinsic problems of these probes, such as complex synthetic routes and high molecular weight, remain challenging. Here, we developed novel phenaleno isoquinolinium-based fluorescent agents, Medical Fluorophores 37-41 (MF37-41), applicable to the quantitative and sensitive detection of sentinel lymph nodes (SLNs). These imaging agents showed no adverse effects on the proliferation of immune and normal cells and did not induce in vivo toxicity. In vivo fluorescence lifetime imaging demonstrated the accumulation of phenaleno isoquinolinium salts in the SLNs of nude mice within 15 min postinjection, consistent with our biodistribution findings. These results suggest that phenaleno isoquinolinium salts are feasible fluorescence imaging agents that can be used as potential lymphatic tracers.


Assuntos
Materiais Biocompatíveis/química , Descoberta de Drogas , Corantes Fluorescentes/química , Isoquinolinas/química , Imagem Óptica , Fenalenos/química , Linfonodo Sentinela/diagnóstico por imagem , Animais , Materiais Biocompatíveis/administração & dosagem , Materiais Biocompatíveis/síntese química , Linhagem Celular , Cricetulus , Corantes Fluorescentes/administração & dosagem , Corantes Fluorescentes/síntese química , Injeções Intravenosas , Isoquinolinas/administração & dosagem , Teste de Materiais , Camundongos , Estrutura Molecular , Fenalenos/administração & dosagem
19.
Org Biomol Chem ; 19(37): 8009-8013, 2021 09 29.
Artigo em Inglês | MEDLINE | ID: mdl-34236071

RESUMO

To improve tumor selectivity, a triple-targeting delivery system (Oct-FK(PBA-Az)-Dox) carrying two anticancer agents (apoptozole (Az) and doxorubicin (Dox)) was designed and synthesized. The results showed that both anticancer agents in Oct-FK(PBA-Az)-Dox are liberated in the presence of both H2O2 and cathepsin B, which are normally present at high levels in tumors.


Assuntos
Peróxido de Hidrogênio
20.
Taehan Yongsang Uihakhoe Chi ; 82(2): 280-297, 2021 Mar.
Artigo em Coreano | MEDLINE | ID: mdl-36238735

RESUMO

International guidelines recommended screening with ultrasonography (US) every 6 months for patients at risk for hepatocellular carcinoma (HCC). However, US demonstrates low sensitivity for the early detection of HCC. Magnetic resonance imaging (MRI) plays an important role in the noninvasive diagnosis of HCC, but it is not suitable for surveillance due to its lengthy examination and high cost. Therefore, several studies have been using various abbreviated MRI strategies, including noncontrast abbreviated MRI, dynamic contrast-enhanced abbreviated MRI, and abbreviated MRI using hepatobiliary phase image for HCC surveillance. In this article, we aim to review these various strategies and explore the future direction of HCC surveillance considering the cost-effectiveness aspect.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA