Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Bioengineering (Basel) ; 10(5)2023 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-37237590

RESUMO

Unbiased metagenomic sequencing is conceptually well-suited for first-line diagnosis as all known and unknown infectious entities can be detected, but costs, turnaround time and human background reads in complex biofluids, such as plasma, hinder widespread deployment. Separate preparations of DNA and RNA also increases costs. In this study, we developed a rapid unbiased metagenomics next-generation sequencing (mNGS) workflow with a human background depletion method (HostEL) and a combined DNA/RNA library preparation kit (AmpRE) to address this issue. We enriched and detected bacterial and fungal standards spiked in plasma at physiological levels with low-depth sequencing (<1 million reads) for analytical validation. Clinical validation also showed 93% of plasma samples agreed with the clinical diagnostic test results when the diagnostic qPCR had a Ct < 33. The effect of different sequencing times was evaluated with the 19 h iSeq 100 paired end run, a more clinically palatable simulated iSeq 100 truncated run and the rapid 7 h MiniSeq platform. Our results demonstrate the ability to detect both DNA and RNA pathogens with low-depth sequencing and that iSeq 100 and MiniSeq platforms are compatible with unbiased low-depth metagenomics identification with the HostEL and AmpRE workflow.

3.
Ann Thorac Surg ; 114(1): e29-e32, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-34678292

RESUMO

Aerosol-generating procedures are avoided for patients with coronavirus disease 2019 (COVID-19) to lower the risk of transmission to health care providers. However, when bronchoscopy is indicated, it remains unclear whether the procedure performed while the patient is under general anesthesia leads to contamination of the surroundings and whether standard endoscopy reprocessing methods are effective in eradicating severe acute respiratory syndrome coronavirus 2. This report describes a case of bronchoscopic retrieval of a foreign body in the airway of a patient under general anesthesia who tested positive for COVID-19. The report focuses on anesthesia techniques to minimize aerosolization.


Assuntos
COVID-19 , Pandemias , Aerossóis , Broncoscopia , Humanos , Transmissão de Doença Infecciosa do Paciente para o Profissional/prevenção & controle , Pandemias/prevenção & controle , SARS-CoV-2
4.
JAMA Otolaryngol Head Neck Surg ; 147(5): 418-425, 2021 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-33599684

RESUMO

Importance: Three-dimensionally printed nasopharyngeal swabs (3DP swabs) have been used to mitigate swab shortages during the coronavirus disease 2019 (COVID-19) pandemic. Clinical validation for diagnostic accuracy and consistency, as well as patient acceptability, is crucial to evaluate the swab's performance. Objective: To determine the accuracy and acceptability of the 3DP swab for identifying severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). Design, Setting, and Participants: A diagnostic study was conducted from May to July 2020 at 2 tertiary care centers in Singapore with different reference swabs (FLOQSwab [COPAN Diagnostics] or Dacron swab [Deltalab]) and swab processing techniques (wet or dry) to evaluate the performance of the 3DP swab compared with traditional, standard-of-care nasopharyngeal swabs used in health care institutions. The participants were patients with COVID-19 in the first 2 weeks of illness and controls with acute respiratory illness with negative test results for SARS-CoV-2. Paired nasopharyngeal swabs were obtained from the same nostril and tested for SARS-CoV-2 by reverse-transcriptase polymerase chain reaction. The sequence of swabs was randomized based on odd and even participant numbers. Main Outcomes and Measures: Primary outcome measures were overall agreement (OA), positive percentage agreement (PPA), and negative percentage agreement of the 3DP swab compared with reference swabs. Secondary outcome measures were the correlation of cycle threshold (Ct) values of both swabs. Results: The mean (SD) age of participants was 45.4 (13.1) years, and most participants were men (87 of 89 [97.8%]), in keeping with the epidemiology of the COVID-19 pandemic in Singapore. A total of 79 patients with COVID-19 and 10 controls were recruited. Among the patients with COVID-19, the overall agreement and PPA of the 3DP swab was 91.1% and 93.5%, respectively, compared with reference swabs. The PPA was 100% for patients with COVID-19 who were tested within the first week of illness. All controls tested negative. The reverse-transcriptase polymerase chain reaction Ct values for the ORF1ab and E-gene targets showed a strong correlation (intraclass correlations coefficient, 0.869-0.920) between the 3DP and reference swab on independent testing at each institution despite differences in sample processing. Discordant results for both gene targets were observed only at high Ct values. Conclusions and Relevance: In this diagnostic study of 79 patients with COVID-19 and 10 controls, the 3DP swab performed accurately and consistently across health care institutions and could help mitigate strained resources in the escalating COVID-19 pandemic.


Assuntos
Teste de Ácido Nucleico para COVID-19/instrumentação , COVID-19/diagnóstico , Nasofaringe/virologia , Impressão Tridimensional , Adulto , Desenho de Equipamento , Humanos , Pessoa de Meia-Idade , Pandemias , SARS-CoV-2
6.
J Clin Pathol ; 71(6): 522-531, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29180507

RESUMO

AIM: The presence of biallelic CEBPA mutations is a favourable prognostic feature in acute myeloid leukaemia (AML). CEBPA mutations are currently identified through conventional capillary sequencing (CCS). With the increasing adoption of next-generation sequencing (NGS) platforms, challenges with regard to amplification efficiency of CEBPA due to the high GC content may be encountered, potentially resulting in suboptimal coverage. Here, the performance of an amplicon-based NGS method using a laboratory-developed CEBPA-specific Nextera XT (CEBNX) was evaluated. METHODS: Mutational analyses of the CEBPA gene of 137 AML bone marrow or peripheral blood retrospective specimens were performed by the amplification of the CEBPA gene using the Expand Long Range dNTPack and the amplicons processed by CCS and NGS. CEBPA-specific libraries were then constructed using the Nextera XT V.2 kit. All FASTQ files were then processed with the MiSeq Reporter V.2.6.2.3 using the PCR Amplicon workflow via the customised CEBPA-specific manifest file. The variant calling format files were analysed using the Illumina Variant Studio V.2.2. RESULTS: A coverage per base of 3631X to 28184X was achieved. 22 samples (16.1%) were found to contain CEBPA mutations, with variant allele frequencies (VAF) ranging from 3.8% to 58.2%. Taking CCS as the 'gold standard', sensitivity and specificity of 97% and 97% was achieved. For the transactivation domain 2 polymorphism (c.584_589dupACCCGC/p.His195_Pro196dup), the CEBNX achieved 100% sensitivity and 100% specificity relative to CCS. CONCLUSIONS: Our laboratory-developed CEBNX workflow shows high coverage and thus overcomes the challenges associated with amplification efficiency and low coverage of CEBPA. Therefore, our assay is suitable for deployment in the clinical laboratory.


Assuntos
Biomarcadores Tumorais/genética , Proteínas Estimuladoras de Ligação a CCAAT/genética , Análise Mutacional de DNA/métodos , Sequenciamento de Nucleotídeos em Larga Escala , Leucemia Mieloide Aguda/genética , Mutação , Linhagem Celular Tumoral , Frequência do Gene , Humanos , Leucemia Mieloide Aguda/diagnóstico , Reação em Cadeia da Polimerase , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Estudos Retrospectivos , Fluxo de Trabalho
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA