1.
Int J Hyperthermia ; 41(1): 2369305, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38897626

RESUMO

PURPOSE: To evaluate the safety and efficacy of performing histotripsy through overlying gas-filled bowel in an ex vivo swine model. METHODS: An ex vivo model was created to simulate histotripsy treatment of solid organs through gas-filled bowel. Spherical 2.5 cm histotripsy treatments were performed in agar phantoms for each of five treatment groups: 1) control with no overlying bowel (n = 6), 2) bowel 0 cm above phantom (n = 6), 3) bowel 1 cm above phantom (n = 6), 4) bowel 2 cm above phantom (n = 6), and 5) bowel 0 cm above the phantom with increased treatment amplitude (n = 6). Bowel was inspected for gross and microscopic damage, and treatment zones were measured. A ray-tracing simulation estimated the percentage of therapeutic beam path blockage by bowel in each scenario. RESULTS: All histotripsy treatments through partial blockage were successful (24/24). No visible or microscopic damage was observed to intervening bowel. Partial blockage resulted in a small increase in treatment volume compared to controls (p = 0.002 and p = 0.036 for groups with bowel 0 cm above the phantom, p > 0.3 for bowel 1 cm and 2 cm above the phantom). Gas-filled bowel was estimated to have blocked 49.6%, 35.0%, and 27.3% of the therapeutic beam at 0, 1, and 2 cm, respectively. CONCLUSION: Histotripsy has the potential to be applied through partial gas blockage of the therapeutic beam path, as shown by this ex vivo small bowel model. Further work in an in vivo survival model appears indicated.


Assuntos
Intestino Delgado , Animais , Suínos , Gases
2.
BMC Biomed Eng ; 6(1): 2, 2024 Mar 11.
Artigo em Inglês | MEDLINE | ID: mdl-38468322

RESUMO

BACKGROUND: MAR algorithms have not been productized in interventional imaging because they are too time-consuming. Application of a beam hardening filter can mitigate metal artifacts and doesn't increase computational burden. We evaluate the ability to reduce metal artifacts of a 0.5 mm silver (Ag) additional filter in a Multidetector Computed Tomography (MDCT) scanner during CT-guided biopsy procedures. METHODS: A biopsy needle was positioned inside the lung field of an anthropomorphic phantom (Lungman, Kyoto Kagaku, Kyoto, Japan). CT acquisitions were performed with beam energies of 100 kV, 120 kV, 135 kV, and 120 kV with the Ag filter and reconstructed using a filtered back projection algorithm. For each measurement, the CTDIvol was kept constant at 1 mGy. Quantitative profiles placed in three regions of the artifact (needle, needle tip, and trajectory artifacts) were used to obtain metrics (FWHM, FWTM, width at - 100 HU, and absolute error in HU) to evaluate the blooming artifact, artifact width, change in CT number, and artifact range. An image quality analysis was carried out through image noise measurement. A one-way analysis of variance (ANOVA) test was used to find significant differences between the conventional CT beam energies and the Ag filtered 120 kV beam. RESULTS: The 120 kV-Ag is shown to have the shortest range of artifacts compared to the other beam energies. For needle tip and trajectory artifacts, a significant reduction of - 53.6% (p < 0.001) and - 48.7% (p < 0.001) in the drop of the CT number was found, respectively, in comparison with the reference beam of 120 kV as well as a significant decrease of up to - 34.7% in the artifact width (width at - 100 HU, p < 0.001). Also, a significant reduction in the blooming artifact of - 14.2% (FWHM, p < 0.001) and - 53.3% (FWTM, p < 0.001) was found in the needle artifact. No significant changes (p > 0.05) in image noise between the conventional energies and the 120 kV-Ag were found. CONCLUSIONS: A 0.5 mm Ag additional MDCT filter demonstrated consistent metal artifact reduction generated by the biopsy needle. This reduction may lead to a better depiction of the target and surrounding structures while maintaining image quality.

3.
Radiol Imaging Cancer ; 6(2): e230080, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-38334471

RESUMO

Purpose To determine if microwave ablation (MWA) of retroperitoneal tumors can safely provide high rates of local tumor control. Materials and Methods This retrospective study included 19 patients (median age, 65 years [range = 46-78 years]; 13 [68.4%] men and six [31.6%] women) with 29 retroperitoneal tumors treated over 22 MWA procedures. Hydrodissection (0.9% saline with 2% iohexol) was injected in 17 of 22 (77.3%) procedures to protect nontarget anatomy. The primary outcomes evaluated were local tumor progression (LTP) and complication rates. Oncologic outcomes, including overall survival (OS), progression-free survival (PFS), and treatment-free interval (TFI), were examined as secondary outcome measures. Results Median follow-up was 18 months (range = 0.5-113). Hydrodissection was successful in displacing nontarget anatomy in 16 of 17 (94.1%) procedures. The LTP rate was 3.4% (one of 29; 95% CI: 0.1, 17.8) per tumor and 5.3% (one of 19; 95% CI: 0.1, 26.0) per patient. The overall complication rate per patient was 15.8% (three of 19), including two minor complications and one major complication. The OS rate at 1, 2, and 3 years was 81.8%, 81.8%, and 72.7%, respectively, with a median OS estimated at greater than 7 years. There was no evidence of a difference in OS (P = .34) and PFS (P = .56) between patients with renal cell carcinoma (six of 19 [31.6%]) versus other tumors (13 of 19 [68.4%]) and patients treated with no evidence of disease (15 of 22 [68.2%]) versus patients with residual tumors (seven of 22 [31.8%]). Median TFI was 18 months (range = 0.5-108). Conclusion Treatment of retroperitoneal tumors with MWA combined with hydrodissection provided high rates of local control, prolonged systemic therapy-free intervals, and few serious complications. Keywords: Ablation Techniques (ie, Radiofrequency, Thermal, Chemical), Retroperitoneum, Microwave Ablation, Hydrodissection © RSNA, 2024.


Assuntos
Neoplasias Renais , Neoplasias Retroperitoneais , Masculino , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Neoplasias Retroperitoneais/diagnóstico por imagem , Neoplasias Retroperitoneais/radioterapia , Neoplasias Retroperitoneais/cirurgia , Resultado do Tratamento , Micro-Ondas/uso terapêutico , Estudos Retrospectivos , Neoplasias Renais/diagnóstico por imagem , Neoplasias Renais/cirurgia
4.
Tech Vasc Interv Radiol ; 26(3): 100911, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38071032

RESUMO

CT navigation (CTN) has recently been developed to combine many of the advantages of conventional CT and CT-fluoroscopic guidance for needle placement. CTN systems display real-time needle position superimposed on a CT dataset. This is accomplished by placing electromagnetic (EM) or optical transmitters/sensors on the patient and needle, combined with fiducials placed within the scan field to superimpose a known needle location onto a CT dataset. Advantages of CTN include real-time needle tracking using a contemporaneous CT dataset with the patient in the treatment position, reduced radiation to the physician, facilitation of procedures outside the gantry plane, fewer helical scans during needle placement, and needle guidance based on diagnostic-quality CT datasets. Limitations include the display of a virtual (vs actual) needle position, which can be inaccurate if the needle bends, the fiducial moves, or patient movement occurs between scans, and limitations in anatomical regions with a high degree of motion such as the lung bases. This review summarizes recently introduced CTN technologies in comparison to historical methods of CT needle guidance. A "How I do it" section follows, which describes how CT navigation has been integrated into the study center for both routine and challenging procedures, and includes step-by-step explanations, technical tips, and pitfalls.


Assuntos
Cirurgia Assistida por Computador , Tomografia Computadorizada por Raios X , Humanos , Fenômenos Eletromagnéticos , Cirurgia Assistida por Computador/métodos
5.
J Vasc Interv Radiol ; 2023 Nov 24.
Artigo em Inglês | MEDLINE | ID: mdl-38008378

RESUMO

PURPOSE: To evaluate the concordance between lung biopsy puncture pathways determined by artificial intelligence (AI) and those determined by expert physicians. MATERIALS AND METHODS: An AI algorithm was created to choose optimal lung biopsy pathways based on segmented thoracic anatomy and emphysema in volumetric lung computed tomography (CT) scans combined with rules derived from the medical literature. The algorithm was validated using pathways generated from CT scans of randomly selected patients (n = 48) who had received percutaneous lung biopsies and had noncontrast CT scans of 1.25-mm thickness available in picture archiving and communication system (PACS) (n = 28, mean age, 68.4 years ± 9.2; 12 women, 16 men). The algorithm generated 5 potential pathways per scan, including the computer-selected best pathway and 4 random pathways (n = 140). Four experienced physicians rated each pathway on a 1-5 scale, where scores of 1-3 were considered safe and 4-5 were considered unsafe. Concordance between computer and physician ratings was assessed using Cohen's κ. RESULTS: The algorithm ratings were statistically equivalent to the physician ratings (safe vs unsafe: κ¯=0.73; ordinal scale: κ¯=0.62). The computer and physician ratings were identical in 57.9% (81/140) of cases and differed by a median of 0 points. All least-cost "best" pathways generated by the algorithm were considered safe by both computer and physicians (28/28) and were judged by physicians to be ideal or near ideal. CONCLUSIONS: AI-generated lung biopsy puncture paths were concordant with expert physician reviewers and considered safe. A prospective comparison between computer- and physician-selected puncture paths appears indicated in addition to expansion to other anatomic locations and procedures.

6.
Int J Hyperthermia ; 40(1): 2272065, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37875279

RESUMO

Histotripsy is an emerging noninvasive, non-thermal, and non-ionizing focused ultrasound (US) therapy that can be used to destroy targeted tissue. Histotripsy has evolved from early laboratory prototypes to clinical systems which have been comprehensively evaluated in the preclinical environment to ensure safe translation to human use. This review summarizes the observations and results from preclinical histotripsy studies in the liver, kidney, and pancreas. Key findings from these studies include the ability to make a clinically relevant treatment zone in each organ with maintained collagenous architecture, potentially allowing treatments in areas not currently amenable to thermal ablation. Treatments across organ capsules have proven safe, including in anticoagulated models which may expand patients eligible for treatment or eliminate the risk associated with taking patients off anti-coagulation. Treatment zones are well-defined with imaging and rapidly resorb, which may allow improved evaluation of treatment zones for residual or recurrent tumor. Understanding the effects of histotripsy in animal models will help inform physicians adopting histotripsy for human clinical use.


Assuntos
Ablação por Ultrassom Focalizado de Alta Intensidade , Neoplasias , Animais , Humanos , Ablação por Ultrassom Focalizado de Alta Intensidade/métodos , Fígado/cirurgia , Neoplasias/terapia , Modelos Animais , Rim
7.
J Vasc Interv Radiol ; 34(11): 1986-1996, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37481064

RESUMO

PURPOSE: To compare the safety and efficacy of histotripsy with cryoablation in a chronic human-scale normal porcine kidney model. MATERIALS AND METHODS: Eighteen female domestic swine were divided evenly into histotripsy and cryoablation treatment arms. A planned 2-3 cm diameter treatment was performed under ultrasound (histotripsy) or ultrasound and computed tomography (CT) guidance (cryoablation). Contrast-enhanced CT and serum blood analysis were performed immediately postprocedure and on day 7, with either immediate killing (n = 3) or continued survival to day 30 (n = 6), at which time contrast-enhanced CT, serum blood analysis, and necropsy were performed. Animal welfare, treatment zone appearance, procedure-related adverse events, and histopathology of the treatment zones and surrounding tissues were assessed. RESULTS: Histotripsy treatment zones (mean ±standard deviation diameters, 2.7 ± 0.12 × 2.4 ± 0.19 × 2.4 ± 0.26 cm; volume, 8.3 ± 1.9 cm3) were larger than cryoablation zones (mean diameters, 2.2 ± 0.19 × 1.9 ± 0.13 × 1.7 ± 0.19 cm; volume, 3.9 ± 0.8 cm3; P < .001). At 30 days, histotripsy and cryoablation treatment zone volumes decreased by 96% and 83% on CT, respectively (P < .001). Perirenal hematomas were present after 8 of 9 (89%) cryoablation (mean volume, 22.2 cm3) and 1 of 9 (11%, P < .001) histotripsy (volume, 0.4 cm3) procedures, with active arterial extravasation in 4 of 9 (44%) cryoablation and no histotripsy animals (P = .206). All 9 histotripsy animals and 5 of 9 (56%) cryoablation animals had collecting system debris (P = .042). Changes in serum creatinine were similar between the groups (P = .321). CONCLUSIONS: Other than a higher rate of bleeding after cryoablation, the safety and early efficacy of histotripsy and cryoablation were comparable for creating treatment zones in a chronic normal porcine kidney model.


Assuntos
Criocirurgia , Neoplasias Renais , Humanos , Suínos , Feminino , Animais , Criocirurgia/efeitos adversos , Criocirurgia/métodos , Rim/patologia , Neoplasias Renais/patologia , Tomografia Computadorizada por Raios X , Hemorragia Gastrointestinal/etiologia , Resultado do Tratamento
8.
J Vasc Interv Radiol ; 34(5): 910-918, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36736821

RESUMO

PURPOSE: To compare electromagnetic navigation (EMN) with computed tomography (CT) fluoroscopy for guiding percutaneous biopsies in the abdomen and pelvis. MATERIALS AND METHODS: A retrospective matched-cohort design was used to compare biopsies in the abdomen and pelvis performed with EMN (consecutive cases, n = 50; CT-Navigation; Imactis, Saint-Martin-d'Hères, France) with those performed with CT fluoroscopy (n = 100). Cases were matched 1:2 (EMN:CT fluoroscopy) for target organ and lesion size (±10 mm). RESULTS: The population was well-matched (age, 65 vs 65 years; target size, 2.0 vs 2.1 cm; skin-to-target distance, 11.4 vs 10.7 cm; P > .05, EMN vs CT fluoroscopy, respectively). Technical success (98% vs 100%), diagnostic yield (98% vs 95%), adverse events (2% vs 5%), and procedure time (33 minutes vs 31 minutes) were not statistically different (P > .05). Operator radiation dose was less with EMN than with CT fluoroscopy (0.04 vs 1.2 µGy; P < .001), but patient dose was greater (30.1 vs 9.6 mSv; P < .001) owing to more helical scans during EMN guidance (3.9 vs 2.1; P < .001). CT fluoroscopy was performed with a mean of 29.7 tap scans per case. In 3 (3%) cases, CT fluoroscopy was performed with gantry tilt, and the mean angle out of plane for EMN cases was 13.4°. CONCLUSIONS: Percutaneous biopsies guided by EMN and CT fluoroscopy were closely matched for technical success, diagnostic yield, procedure time, and adverse events in a matched cohort of patients. EMN cases were more likely to be performed outside of the gantry plane. Radiation dose to the operator was higher with CT fluoroscopy, and patient radiation dose was higher with EMN. Further study with a wider array of procedures and anatomic locations is warranted.


Assuntos
Fenômenos Eletromagnéticos , Tomografia Computadorizada por Raios X , Humanos , Idoso , Estudos Retrospectivos , Biópsia , Tomografia Computadorizada por Raios X/efeitos adversos , Tomografia Computadorizada por Raios X/métodos , Abdome , Pelve , Fluoroscopia
9.
J Vasc Interv Radiol ; 34(3): 386-394.e2, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36503074

RESUMO

PURPOSE: To determine the risk of mechanical vessel wall damage resulting in hemorrhage during and after hepatic and renal histotripsy in an anticoagulated in vivo porcine model. MATERIALS AND METHODS: Non-tumor-bearing pigs (n = 8; mean weight, 52.5 kg) were anticoagulated with warfarin (initial dose, 0.08 mg/kg) to a target prothrombin time (PT) of 30%-50% above baseline. A total of 15 histotripsy procedures were performed (kidney: n = 8, 2.0-cm sphere; liver: n = 7, 2.5-cm sphere). Treatments were immediately followed by computed tomography (CT) imaging. Animals were observed for 7 days while continuing anticoagulation, followed by repeat CT and necropsy. RESULTS: All animals survived to complete the entire protocol with no signs of disability or distress. Three animals had hematuria (pink urine without clots). Baseline PT values (mean, 16.0 seconds) were elevated to 22.0 seconds (37.5% above baseline, P = .003) on the day of treatment and to 28.8 seconds (77.8% above baseline, P < .001) on the day of necropsy. At the time of treatment, 5 of 8 (63%) animals were at a therapeutic anticoagulation level, and all 8 animals (100%) reached therapeutic levels by the time of necropsy. There were no cases of intraparenchymal, peritoneal, or retroperitoneal hemorrhage associated with any treatments despite 5 of 7 (71%) liver and all 8 (100%) kidney treatments extending to the organ surface. CONCLUSIONS: Liver and kidney histotripsy seems safe with no elevated bleeding risk in this anticoagulated animal model, supporting the possibility of histotripsy treatments in patients on anticoagulation.


Assuntos
Ablação por Ultrassom Focalizado de Alta Intensidade , Fígado , Suínos , Animais , Rim , Hemorragia/etiologia , Ablação por Ultrassom Focalizado de Alta Intensidade/efeitos adversos , Anticoagulantes
10.
Eur Radiol ; 33(2): 1050-1062, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36048208

RESUMO

OBJECTIVE: To compare the acute and chronic safety and treatment effects of non-invasive hepatic histotripsy vs. percutaneous microwave (MW) ablation in a healthy porcine model. METHODS: This was a dual-arm study in which each animal (n = 14) received either a single hepatic microwave (n = 6) or histotripsy (n = 6 single treatment; n = 2 double treatment) under ultrasound guidance. The goal was to create 2.5-3.0 cm short-axis treatments in similar locations across modalities. Animals were survived for 1 month with contrast-enhanced CT imaging on days 0, 2, 7, 14, and 28. On day 28, necropsy and histopathology were performed. RESULTS: All procedures were well-tolerated. MW ablation zones were longer and more oblong, but equivalent in the short axes to histotripsy zones on immediate post-procedure CT (p < 0.001 and p = 0.45, respectively). Overall, MW volumes were larger (21.4 cm3 vs. 13.4 cm3; p = 0.001) and histotripsy treatment zones were more spherical (p = 0.007). Histotripsy zones were close to the prescribed size (p < 0.001). Over the study period, histotripsy treatment zones decreased in volume while microwave ablation zones slightly increased (-83% vs. +17%, p = 0.001). There were several imaging-only findings: Branch portal vein thrombus with both histotripsy (7/8) and MW (6/6), hematoma in 2/6 MW only, and a gallbladder injury in 1/6 MW animals. The ablation zones demonstrated complete cellular destruction for both modalities. CONCLUSION: Histotripsy was associated with more spherical treatments, fewer biliary complications, and greater treatment zone involution. Hepatic MW and histotripsy treatment in a normal porcine model appear at least equally effective for creating treatment zones with a similar safety profile. KEY POINTS: • Microwave ablation and histotripsy for liver treatment in a healthy porcine model yield equivalent procedural tolerance and cellular destruction. • Histotripsy was associated with more spherical treatments, fewer biliary complications, and greater treatment zone involution over the 28-day follow-up period. • These findings confirm the safety and efficacy of hepatic histotripsy and support the pursuit of clinical trials to further evaluate the translatability of these results.


Assuntos
Técnicas de Ablação , Ablação por Cateter , Ablação por Radiofrequência , Suínos , Animais , Micro-Ondas/uso terapêutico , Fígado/diagnóstico por imagem , Fígado/cirurgia , Fígado/irrigação sanguínea , Técnicas de Ablação/métodos , Veia Porta/cirurgia , Ablação por Cateter/métodos
11.
Int J Hyperthermia ; 39(1): 1115-1123, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36002243

RESUMO

Rationale Current hepatic locoregional therapies are limited in terms of effectiveness and toxicities. Given promising pre-clinical results, a first in-human trial was designed to assess the technical effectiveness and safety profile of histotripsy, a noninvasive, non-thermal, non-ionizing focused ultrasound therapy that creates precise, predictable tissue destruction, in patients with primary and secondary liver tumors.Methods A multicenter phase I trial (Theresa Study) was performed in a single country with 8 weeks of planned follow-up. Eight of fourteen recruited patients were deemed eligible and enrolled in the study. Hepatic histotripsy, was performed with a prototype system (HistoSonics, Inc., Ann Arbor, MI). Eleven tumors were targeted in the 8 patients who all had unresectable end-stage multifocal liver tumors: colorectal liver metastases (CRLM) in 5 patients (7 tumors), breast cancer metastases in 1 (1 tumor), cholangiocarcinoma metastases in 1 (2 tumors), and hepatocellular carcinoma (HCC) in 1 (1 tumor). The primary endpoint was acute technical success, defined as creating a zone of tissue destruction per planned volume assessed by MRI 1-day post-procedure. Safety (device-related adverse events) through 2 months was a secondary endpoint.Results The 8 patients had a median age of 60.4 years with an average targeted tumor diameter of 1.4 cm. The primary endpoint was achieved in all procedures. The secondary safety profile endpoint identified no device-related adverse events. Two patients experienced a continuous decline in tumor markers during the eight weeks following the procedure.Conclusions This first-in-human trial demonstrates that hepatic histotripsy effectively destroys liver tissue in a predictable manner, correlating very well with the planned histotripsy volume, and has a high safety profile without any device-related adverse events. Based on these results, the need for more definitive clinical trials is warranted. Trial Registration: Study to Evaluate VORTX Rx (Theresa). NCT03741088. https://clinicaltrials.gov/ct2/show/NCT03741088 KEY POINTSHistotripsy, a new noninvasive, non-thermal, non-ionizing focused ultrasound therapy, safely created a zone of tissue destruction in the liver that correlated very well with the pre-defined planned tissue destruction volume.In this first human trial histotripsy was well tolerated with no histotripsy device-related adverse events and its primary endpoint of acute technical success was achieved in all 8 enrolled patients with primary or secondary liver tumors.This new locoregional therapy for patients with liver tumors is safe and effective, warranting further trials.


Assuntos
Carcinoma Hepatocelular , Ablação por Ultrassom Focalizado de Alta Intensidade , Neoplasias Hepáticas , Carcinoma Hepatocelular/etiologia , Estudos de Viabilidade , Ablação por Ultrassom Focalizado de Alta Intensidade/métodos , Humanos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/etiologia , Neoplasias Hepáticas/terapia , Pessoa de Meia-Idade
12.
J Vasc Interv Radiol ; 33(9): 1045-1053, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35667580

RESUMO

PURPOSE: To evaluate the efficacy and safety of microwave (MW) ablation as first-line locoregional therapy (LRT) for bridging patients with hepatocellular carcinoma (HCC) to liver transplant. MATERIALS AND METHODS: This retrospective study evaluated 88 patients who received percutaneous MW ablation for 141 tumors as first-line LRT for HCC and who were listed for liver transplantation at a single medical center between 2011 and 2019. The overall survival (OS) rate statuses after liver transplant, waitlist retention, and disease progression were evaluated using the Kaplan-Meier techniques. RESULTS: Among the 88 patients (72 men and 16 women; mean age, 60 years; Model for End-Stage Liver Disease score, 11.2) who were listed for transplant, the median waitlist time was 9.4 months (interquartile range, 5.5-18.9). Seventy-one (80.7%) patients received transplant after a median waitlist time of 8.5 months. Seventeen (19.3%) patients were removed from the waitlist; of these, 4 (4.5%) were removed because of tumors outside of the Milan criteria (HCC-specific dropout). No difference in tumor size or alpha-fetoprotein was observed in the transplanted versus nontransplanted patients at the time of ablation (2.1 vs 2.1 cm and 34.4 vs 34.7 ng/mL for transplanted vs nontransplanted, respectively; P > .05). Five (5.1%) of the 88 patients experienced adverse events after ablation; however, they all recovered. There were no cases of tract seeding. The local tumor progression (LTP) rate was 7.2%. The OS status after liver transplant at 5 years was 76.7%, and the disease-specific survival after LTP was 89.6%, with a median follow-up of 61 months for all patients. CONCLUSIONS: MW ablation appears to be safe and effective for bridging patients with HCC to liver transplant without waitlist removal from seeding, adverse events, or LTP.


Assuntos
Carcinoma Hepatocelular , Ablação por Cateter , Doença Hepática Terminal , Neoplasias Hepáticas , Transplante de Fígado , Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/patologia , Carcinoma Hepatocelular/cirurgia , Ablação por Cateter/efeitos adversos , Feminino , Humanos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/patologia , Neoplasias Hepáticas/cirurgia , Transplante de Fígado/métodos , Masculino , Micro-Ondas/efeitos adversos , Pessoa de Meia-Idade , Estudos Retrospectivos , Índice de Gravidade de Doença , Resultado do Tratamento
13.
Cancers (Basel) ; 14(7)2022 Mar 22.
Artigo em Inglês | MEDLINE | ID: mdl-35406383

RESUMO

Histotripsy has been used for tumor ablation, through controlled, non-invasive acoustic cavitation. This is the first study to evaluate the impact of partial histotripsy ablation on immune infiltration, survival outcomes, and metastasis development, in an in vivo orthotopic, immunocompetent rat HCC model (McA-RH7777). At 7−9 days post-tumor inoculation, the tumor grew to 5−10 mm, and ~50−75% tumor volume was treated by ultrasound-guided histotripsy, by delivering 1−2 cycle histotripsy pulses at 100 Hz PRF (focal peak negative pressure P− >30 MPa), using a custom 1 MHz transducer. Complete local tumor regression was observed on MRI in 9/11 histotripsy-treated rats, with no local recurrence or metastasis up to the 12-week study end point, and only a <1 mm residual scar tissue observed on histology. In comparison, 100% of untreated control animals demonstrated local tumor progression, developed intrahepatic metastases, and were euthanized at 1−3 weeks. Survival outcomes in histotripsy-treated animals were significantly improved compared to controls (p-value < 0.0001). There was evidence of potentially epithelial-to-mesenchymal transition (EMT) in control tumor and tissue healing in histotripsy-treated tumors. At 2- and 7-days post-histotripsy, increased immune infiltration of CD11b+, CD8+ and NK cells was observed, as compared to controls, which may have contributed to the eventual regression of the untargeted tumor region in histotripsy-treated tumors.

14.
Abdom Radiol (NY) ; 47(8): 2658-2668, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-34731282

RESUMO

PURPOSE: To evaluate utility of advanced CT techniques including HighlY constrained back-projection and dual-energy CT for intra- and post-procedure hepatic microwave ablation zone monitoring. METHODS: 8 hepatic microwave ablations were performed in 4 adult swine (5 min/65 W). Low-dose routine CECT and dual-energy CT images were obtained every 1 min during ablation. Images were reconstructed ± HYPR. Image quality and dose metrics were collected. 21 MWA were performed in 4 adult swine. Immediate post-procedure CECT was performed in the arterial, portal venous, and delayed phases using both routine and DECT imaging with full-dose weight-based IV contrast dosing. An additional 16 MWA were subsequently performed in 2 adult swine. Immediate post-procedure CT was performed with half-dose IV contrast using routine and DECT. 12 patients (10 M/2F, mean age 62.4 yrs) with 14 hepatic tumors (4 HCC, 10 metastatic lesions) treated with MWA were prospectively imaged with DECT 1 month post-procedure. 120 kV equivalent images were compared to DECT [51 keV, iodine material density]. Image quality and dose metrics were collected. RESULTS: Gas created during MWA led to high CNR in all intraprocedural CT datasets. Optimal CNRs were noted at 4 min with CNR 6.7, 15.5,15.9, and 21.5 on LD-CECT, LD-CECT + HYPR, DECT, and DECT + HYPR, respectively (p < 0.001). Image quality scores at 4 min were 1.8, 2.8, 2.4, and 3, respectively (p < 0.001). Mean radiation dose (CTDIvol) was eightfold higher for the DECT series. For swine, post-procedural DECT images (IMD/51 keV) showed improved CNR compared to routine CT at all time points with full and with reduced dose contrast (CNR 4.6, 3.2, and 1.5, respectively, at half-contrast dose, p < 0.001). For human subjects, the 51 keV and IMD images showed higher CNRs (5.8, 4.8 vs 4.0, p < 0.001) and SNRs (3.7, 5.9 vs 2.8). Ablation zone sharpness was improved with DECT (routine 3.0 ± 0.7, DECT 3.5 ± 0.5). Diagnostic confidence was higher with DECT (routine 2.3 ± 0.9, DECT 2.6 ± 0.8). Mean DLP for DECT was 905.7 ± 606 mGy-cm, CTDIvol 37.5 ± 21.2 mGy, and effective dose 13.6 ± 9.1 mSv, slightly higher than conventional CT series. CONCLUSION: Advanced CT techniques can improve CT image quality in peri-procedural hepatic microwave ablation zone evaluation.


Assuntos
Carcinoma Hepatocelular , Neoplasias Hepáticas , Adulto , Animais , Meios de Contraste , Seguimentos , Humanos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/cirurgia , Micro-Ondas/uso terapêutico , Pessoa de Meia-Idade , Doses de Radiação , Suínos , Tomografia Computadorizada por Raios X/métodos
15.
Radiology ; 301(3): 533-540, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34581627

RESUMO

There is currently no consensus regarding preferred clinical outcome measures following image-guided tumor ablation or clear definitions of oncologic end points. This consensus document proposes standardized definitions for a broad range of oncologic outcome measures with recommendations on how to uniformly document, analyze, and report outcomes. The initiative was coordinated by the Society of Interventional Oncology in collaboration with the Definition for the Assessment of Time-to-Event End Points in Cancer Trials, or DATECAN, group. According to predefined criteria, based on experience with clinical trials, an international panel of 62 experts convened. Recommendations were developed using the validated three-step modified Delphi consensus method. Consensus was reached on when to assess outcomes per patient, per session, or per tumor; on starting and ending time and survival time definitions; and on time-to-event end points. Although no consensus was reached on the preferred classification system to report complications, quality of life, and health economics issues, the panel did agree on using the most recent version of a validated patient-reported outcome questionnaire. This article provides a framework of key opinion leader recommendations with the intent to facilitate a clear interpretation of results and standardize worldwide communication. Widespread adoption will improve reproducibility, allow for accurate comparisons, and avoid misinterpretations in the field of interventional oncology research. Published under a CC BY 4.0 license. Online supplemental material is available for this article. See also the editorial by Liddell in this issue.


Assuntos
Técnicas de Ablação/métodos , Neoplasias/cirurgia , Consenso , Humanos , Reprodutibilidade dos Testes , Sociedades Médicas
16.
J Gastrointest Oncol ; 12(4): 1454-1469, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34532102

RESUMO

BACKGROUND: The purpose of this study is to evaluate the safety and intermediate-term efficacy of percutaneous microwave (MW) ablation for the treatment of colorectal liver metastases (CRLM) at a single institution. METHODS: A retrospective review was performed of all CRLM treated with MW ablation from 3/2011 to 7/2020 (102 tumors; 72 procedures; 57 patients). Mean age was 60 years (range, 36-88) and mean tumor size was 1.8 cm (range, 0.5-5.0 cm). The patient population included 19 patients with extra-hepatic disease. Chemotherapy (pre- and/or post-ablation) was given in 98% of patients. Forty-five sessions were preceded by other focal CRLM treatments including resection, ablation, radiation, and radioembolization. Kaplan-Meier curves were used to estimate local tumor progression-free survival (LTPFS), disease-free survival (DFS), and overall survival (OS) and multivariate analysis (Cox Proportional Hazards model) was used to test predictors of OS. RESULTS: Technical success (complete ablation) was 100% and median follow-up was 42 months (range, 1-112). There was a 4% major complication rate and an overall complication rate of 8%. Local tumor progression (LTP) rate during the entire study period was 4/98 (4%), in which 2 were retreated with MW ablation for a secondary LTP-rate of 2%. LTP-free survival at 1, 3, and 5 years was 93%, 58%, and 39% and median LTP-free survival was 48 months. OS at 1, 3, and 5 years was 96%, 66%, 47% and median OS was 52 months. There were no statistically significant predictors of OS. CONCLUSIONS: MW ablation of hepatic colorectal liver metastases appears safe with excellent local tumor control and prolonged survival compared to historical controls in selected patients. Further comparative studies with other local treatment strategies appear indicated.

17.
J Endourol ; 35(S2): S33-S37, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34499558

RESUMO

Management options for small renal masses include active surveillance, partial nephrectomy, radical nephrectomy, and thermal ablation. For tumors typically ≤3 cm in size, thermal ablation is a good option for those desiring an alternative to surgery or active surveillance, especially in patients who are considered high surgical risk. We favor microwave ablation because of the more rapid heating, higher temperatures that overcome the heat sink effect of vessels, reproducible cell kill, and a highly visible ablation zone formed by water vapor that corresponds well to the zone of necrosis. For central tumors, we favor cryoablation because of the slower formation of the ablation zone and less likelihood of damage to the collecting system. With microwaves, it is important to monitor the ablation zone in real time (ultrasound is the best modality for this purpose), avoid direct punctures of the collecting system, and to place probes tangential to the collecting system to avoid burning open a persistent tract between the urothelium and extrarenal spaces or causing strictures. The surgical steps described in this video cover our use of high-frequency jet ventilation with general anesthesia to minimize organ motion, initial imaging and targeting, probe insertion, hydrodissection (a technique that enables displacement of adjacent structures), the ablation itself, and finally our dressing. Postoperative cares typically consist of observation with a same-day discharge or an overnight stay. Follow-up includes a magnetic resonance imaging abdomen with and without contrast, chest X-ray, and laboratories (basic metabolic panel, complete blood count, and C-reactive protein) 6 months postablation. Overall, percutaneous microwave ablation is an effective and safe treatment option for renal cell carcinoma in both T1a and T1b tumors in selected patients with multiple studies showing excellent oncologic outcomes when compared with partial and radical nephrectomy.


Assuntos
Carcinoma de Células Renais , Neoplasias Renais , Carcinoma de Células Renais/diagnóstico por imagem , Carcinoma de Células Renais/cirurgia , Humanos , Neoplasias Renais/diagnóstico por imagem , Neoplasias Renais/cirurgia , Micro-Ondas/uso terapêutico , Nefrectomia , Resultado do Tratamento
18.
J Vasc Interv Radiol ; 32(9): 1319-1327, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-34229043

RESUMO

PURPOSE: To evaluate the outcomes of computed tomography (CT) fluoroscopy-guided core lung biopsies with emphasis on diagnostic yield, complications, and efficacy of parenchymal and pleural blood patching to avoid chest tube placement. METHODS: This is a single-center retrospective analysis of CT fluoroscopy-guided percutaneous core lung biopsies between 2006 and 2020. Parenchymal blood patching during introducer needle withdrawal was performed in 74% of cases as a preventive measure, and pleural blood patching was the primary salvage maneuver for symptomatic or growing pneumothorax in 60 of 83 (72.2%) applicable cases. RESULTS: A total of 1,029 patients underwent 1,112 biopsies (532 men; mean age, 66 years; 38.6%, history of emphysema; lesion size, 16.7 mm). The diagnostic yield was 93.6% (1,032/1,103). Fewer complications requiring intervention were observed in patients who underwent parenchymal blood patching (5.7% vs 14.2%, P < .001). Further intervention was required in 83 of 182 pneumothorax cases, which included the following: (a) pleural blood patch (5.4%, 60/1,112), (b) chest tube placement without a pleural blood patch attempt (1.5%, 17/1,112), and (c) simple aspiration (0.5%, 6/1,112). Pleural blood patch as monotherapy was successful in 83.3% (50/60) of cases without need for further intervention. The overall chest tube rate was 2.6% (29/1,112). Emphysema was the only significant risk factor for complications requiring intervention (P ≤ .001). CONCLUSIONS: Parenchymal blood patching during introducer needle withdrawal decreased complications requiring intervention. Salvage pleural blood patching reduced the frequency of chest tube placement for pneumothorax.


Assuntos
Pneumotórax , Radiografia Intervencionista , Idoso , Biópsia , Biópsia com Agulha de Grande Calibre , Humanos , Biópsia Guiada por Imagem , Pulmão/diagnóstico por imagem , Masculino , Pneumotórax/etiologia , Estudos Retrospectivos , Tomografia Computadorizada por Raios X
19.
Cardiovasc Intervent Radiol ; 44(10): 1643-1650, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34244841

RESUMO

PURPOSE: To determine whether histotripsy can create human-scale transcostal ablations in porcine liver without causing severe thermal wall injuries along the beam path. MATERIALS AND METHODS: Histotripsy was applied to the liver using a preclinical prototype robotic system through a transcostal window in six female swine. A 3.0 cm spherical ablation zone was prescribed. Duration of treatment (75 min) was longer than a prior subcostal treatment study (24 min, 15 s) to minimize beam path heating. Animals then underwent contrast-enhanced MRI, necropsy, and histopathology. Images and tissue were analyzed for ablation zone size, shape, completeness of necrosis, and off-target effects. RESULTS: Ablation zones demonstrated complete necrosis with no viable tissue remaining in 6/6 animals by histopathology. Ablation zone volume was close to prescribed (13.8 ± 1.8 cm3 vs. prescribed 14.1 cm3). Edema was noted in the body wall overlying the ablation on T2 MRI in 5/5 (one animal did not receive MRI), though there was no gross or histologic evidence of injury to the chest wall at necropsy. At gross inspection, lung discoloration in the right lower lobe was present in 5/6 animals (mean size: 1 × 2 × 4 cm) with alveolar hemorrhage, preservation of blood vessels and bronchioles, and minor injuries to pneumocytes noted at histology. CONCLUSION: Transcostal hepatic histotripsy ablation appears feasible, effective, and no severe injuries were identified in an acute porcine model when prolonged cooling time is added to minimize body wall heating.


Assuntos
Ablação por Ultrassom Focalizado de Alta Intensidade , Fígado , Animais , Feminino , Fígado/diagnóstico por imagem , Fígado/cirurgia , Pulmão , Imageamento por Ressonância Magnética , Suínos
20.
Clin Genitourin Cancer ; 19(5): e313-e318, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34024743

RESUMO

Microwave (MW) ablation and stereotactic body radiation therapy (SBRT) are both used in treating inoperable renal cell carcinoma (RCC). MW ablation and SBRT have potentially complementary advantages and limitations. Combining SBRT and MW ablation may optimize tumor control and toxicity for patients with larger (> 5 cm) RCCs or those with vascular involvement. Seven patients with RCC were treated at our institution with combination of SBRT and MW ablation, median tumor size of 6.4 cm. Local control was 100% with a median follow-up of 15 months. Four patients experienced grade 2 nausea during SBRT. Three patients experienced toxicities after MW ablation, 2 with grade 1 hematuria and 1 with grade 3 retroperitoneal bleed/collecting system injury. Median eGFR (estimated glomerular filtration rate) preceding and following SBRT and MW ablation was 69 mL/min/1.73 m2 and 68 mL/min/1.73 m2 (P = .19), respectively. In patients who are not surgical candidates, larger RCCs or those with vascular invasion are challenging to treat. Combination treatment with SBRT and MW ablation may balance the risks and benefits of both therapies and demonstrates high local control in our series. MW ablation and SBRT have potentially complementary advantages and limitations.


Assuntos
Carcinoma de Células Renais , Neoplasias Renais , Radiocirurgia , Carcinoma de Células Renais/radioterapia , Carcinoma de Células Renais/cirurgia , Taxa de Filtração Glomerular , Humanos , Neoplasias Renais/radioterapia , Neoplasias Renais/cirurgia , Micro-Ondas , Radiocirurgia/efeitos adversos