Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Biomolecules ; 14(3)2024 Mar 07.
Artigo em Inglês | MEDLINE | ID: mdl-38540738

RESUMO

PURPOSE: This study was conducted to evaluate the effects of different capsulotomy and fragmentation energy levels on the production of oxidative free radicals following femtosecond laser-assisted cataract surgery (FLACS) with a low-energy platform. METHODS: The experimental study included 60 porcine eyes (12 groups). In each group, capsulotomies with 90% or 150% energy, and fragmentations with 90%, 100%, or 150% energy or 150% with high spot density, respectively, were performed. Control samples were obtained from non-lasered eyes at the beginning (five eyes) and end (five eyes) of the experiment. In the clinical study, 104 eyes were divided into 5 groups, and they received conventional phacoemulsification (20 eyes), FLACS with 90% capsulotomy and 100% fragmentation energy levels without NSAIDs (16 eyes), FLACS with 90% (26 eyes) or 150% (22 eyes) capsulotomy energy levels, respectively, with a 100% fragmentation energy level and NSAIDs, and FLACS with 90% capsulotomy and 150% fragmentation energy levels and NSAIDs (20 eyes). Aqueous samples were analyzed for their malondialdehyde (MDA) and superoxide dismutase (SOD) levels. RESULTS: In the experimental study, there were no significant differences in the MDA and SOD levels between the groups with different capsulotomy energy levels. An increase in the fragmentation energy from 100% to 150% led to significantly higher MDA levels in the groups with both 90% (p = 0.04) and 150% capsulotomy energy levels (p = 0.03), respectively. However, increased laser spot densities did not result in significant changes in MDA or SOD levels. In the clinical study, all four of the FLACS groups showed higher MDA levels than the conventional group. Similarly, the increase in the fragmentation energy from 100% to 150% resulted in significantly elevated levels of MDA and SOD, respectively. CONCLUSIONS: Although increasing the FSL capsulotomy energy level may not have increased free radicals, higher fragmentation energy levels increased the generation of aqueous free radicals. However, fragmentation with high spot density did not generate additional oxidative stress. Increased spot density did not generate additional oxidative stress, and this can be helpful for dense cataracts.


Assuntos
Catarata , Terapia a Laser , Humanos , Terapia a Laser/métodos , Catarata/terapia , Lasers , Estresse Oxidativo , Radicais Livres , Anti-Inflamatórios não Esteroides , Superóxido Dismutase
2.
Am J Ophthalmol ; 265: 6-20, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38521157

RESUMO

PURPOSE: To investigate the tear proteomic and neuromediator profiles, in vivo confocal microscopy (IVCM) imaging features, and clinical manifestations in neuropathic corneal pain (NCP) patients. DESIGN: Cross-sectional study. METHODS: A total of 20 NCP patients and 20 age-matched controls were recruited. All subjects were evaluated by corneal sensitivity, Schirmer test, tear break-up time, and corneal and ocular surface staining, Ocular Surface Disease Index and Ocular Pain Assessment Survey questionnaires were administered, as well as IVCM examinations for corneal nerves, microneruomas, and epithelial and dendritic cells. Tears were collected for neuromediator and proteomic analysis using enzyme-linked immunosorbent assay and data-independent acquisition mass spectrometry. RESULTS: Burning and sensitivity to light were the 2 most common symptoms in NCP. A total of 188 significantly dysregulated proteins, such as elevated metallothionein-2, creatine kinases B-type, vesicle-associated membrane protein 2, neurofilament light polypeptide, and myelin basic protein, were identified in the NCP patients. The top 10 dysregulated biological pathways in NCP include neurotoxicity, axonal signaling, wound healing, neutrophil degradation, apoptosis, thrombin signaling mitochondrial dysfunction, and RHOGDI and P70S6K signaling pathways. Compared to controls, the NCP cohort presented with significantly decreased corneal sensitivity (P < .001), decreased corneal nerve fiber length (P = .003), corneal nerve fiber density (P = .006), and nerve fiber fractal dimension (P = .033), as well as increased corneal nerve fiber width (P = .002), increased length, total area and perimeter of microneuromas (P < .001, P < .001, P = .019), smaller corneal epithelial size (P = .017), and higher nerve growth factor level in tears (P = .006). CONCLUSIONS: These clinical manifestations, imaging features, and molecular characterizations would contribute to the diagnostics and potential therapeutic targets for NCP.


Assuntos
Ensaio de Imunoadsorção Enzimática , Dor Ocular , Microscopia Confocal , Neuralgia , Proteômica , Lágrimas , Humanos , Lágrimas/metabolismo , Lágrimas/química , Masculino , Feminino , Proteômica/métodos , Estudos Transversais , Pessoa de Meia-Idade , Dor Ocular/diagnóstico , Neuralgia/metabolismo , Neuralgia/diagnóstico , Neuralgia/fisiopatologia , Adulto , Doenças da Córnea/metabolismo , Doenças da Córnea/diagnóstico , Doenças da Córnea/etiologia , Doenças da Córnea/fisiopatologia , Córnea/inervação , Córnea/metabolismo , Proteínas do Olho/metabolismo , Nervo Oftálmico , Inquéritos e Questionários , Medição da Dor , Biomarcadores/metabolismo , Idoso
3.
Cornea ; 43(4): 409-418, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-37643477

RESUMO

PURPOSE: The aim of this study was to investigate age-related changes in corneal nerves and corneal epithelial cell parameters and to establish age-adjusted reference values. METHODS: A total of 7025 corneal nerve images and 4215 corneal epithelial images obtained using in vivo confocal microscopy from 281 eyes of 143 healthy participants were included. Seven corneal nerve parameters and 3 corneal epithelial cell parameters were quantified using 2 automatic analytic software and analyzed across 6 age groups ranging from 21 to 80 years. RESULTS: There was a declining trend in all 7 nerve parameters with advancing age. In particular, corneal nerve fiber length and corneal nerve fiber density demonstrated a significant decrease in subjects aged 65 years or older compared with subjects younger than 65 years (10.8 ± 2.6 mm/mm 2 vs. 9.9 ± 2.0 mm/mm 2 , P = 0.011 in corneal nerve fiber length; 15.8 ± 5.2 fibers/mm 2 vs. 14.4 ± 4.3 fibers/mm 2 , P = 0.046 in corneal nerve fiber density), whereas corneal nerve fractal dimension demonstrated a borderline significant decrease ( P = 0.057). Similarly, there was a general declining trend in all epithelial cell parameters with advancing age. Corneal epithelial cell circularity was significantly lower in subjects aged 65 years and older as compared to subjects younger than 65 years (0.722 ± 0.021 µm 2 vs. 0.714 ± 0.021 µm 2 ; P = 0.011). CONCLUSIONS: Advancing age results in reduced corneal nerve metrics and alteration of corneal cell morphology. Aging effects should be considered when evaluating patients with corneal neuropathy.


Assuntos
Córnea , Fibras Nervosas , Adulto , Humanos , Córnea/inervação , Células Epiteliais , Microscopia Confocal/métodos , Contagem de Células
4.
J Cataract Refract Surg ; 49(11): 1106-1113, 2023 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-37867284

RESUMO

PURPOSE: To evaluate the impact of corrected refractive power on the corneal denervation and ocular surface in small-incision lenticule extraction (SMILE) and laser in situ keratomileusis (LASIK). SETTING: Singapore National Eye Center, Singapore. DESIGN: Prospective study. METHODS: 88 eyes undergoing SMILE or LASIK were divided into low-moderate (manifest refractive spherical equivalent [MRSE] <-6.0 diopters [D]) and high myopic (MRSE ≥-6.0 D) groups. In vivo confocal microscopy and clinical assessments were performed preoperatively and at 1 month, 3 months, 6 months, and 12 months postoperatively. RESULTS: In SMILE, high myopic treatment presented with significantly greater reduction in the corneal nerve fiber area (CNFA) and nerve fiber fractal dimension (CFracDim) compared with low-moderate myopic treatment (both P < .05). There was a significant and negative correlation between the corrected MRSE and the reduction in corneal nerve fiber density (CNFD), corneal nerve branch density (CNBD), corneal nerve fiber length, CNFA, and CFracDim after SMILE (r = -0.38 to -0.66, all P < .05). In LASIK, a significant correlation between the MRSE and the changes in CNBD, corneal nerve fiber total branch density, CNFA (r = -0.37 to -0.41), and corneal nerve fiber width (r = 0.43) was observed (all P < .05). Compared with SMILE, LASIK had greater reduction in CNBD and CNFA for every diopter increase in the corrected MRSE. High myopic SMILE, compared with low-moderate myopic SMILE, resulted in significantly lower tear break-up time at 1 and 6 months (both P < .05). The changes in CNFA and CFracDim were significantly associated with Schirmer test values (both P < .001). CONCLUSIONS: Postoperative corneal denervation was related to corrected refractive power in both SMILE and LASIK. With the same refractive correction, LASIK led to more prominent corneal denervation.


Assuntos
Ceratomileuse Assistida por Excimer Laser In Situ , Miopia , Humanos , Ceratomileuse Assistida por Excimer Laser In Situ/métodos , Substância Própria/cirurgia , Estudos Prospectivos , Acuidade Visual , Lasers de Excimer/uso terapêutico , Refração Ocular , Miopia/cirurgia , Denervação
5.
J Refract Surg ; 38(9): 587-594, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-36098390

RESUMO

PURPOSE: To assess whether aqueous cytokine profiles and pupil size are altered when high capsulotomy energy is used in eyes undergoing femtosecond laser-assisted cataract surgery (FLACS), and if preoperative use of a topical non-steroidal anti-inflammatory drug (NSAID) has an effect on this. METHODS: This prospective study recruited 83 eyes (63 patients) that were allocated to four treatment groups: conventional phacoemulsification (n = 20 eyes); FLACS with 90% capsulotomy energy without NSAID pretreatment (n = 20 eyes); FLACS with 90% capsulotomy energy with NSAID pre-treatment (n = 21 eyes); and FLACS with 150% capsulotomy energy with NSAID pretreatment (n = 22 eyes). Aqueous humor was collected before and after phacoemulsification to assess cytokine profiles. Pupil size was measured before and after laser capsulotomy. RESULTS: FLACS increased aqueous concentrations of pros-taglandin E2 (PGE2), interferon γ (IFN-γ), and interleukin 6 (IL-6) compared to conventional phacoemulsification. However, when increasing capsulotomy energy from 90% to 150% (with topical NSAID pretreatment), there was no significant increase in aqueous concentrations of PGE2 (37.7 ± 21.7 vs 33.6 ± 27.6 pg/mL, P = .99), IFN-γ (3.6 ± 1.1 vs 3.6 ± 0.8 pg/mL, P = .99), or IL-6 (7.1 ± 2.9 vs 6.3 ± 2.4 pg/mL, P = .99). For 90% and 150% capsulotomy energy, there was significant miosis following laser capsulotomy. Increased PGE2 concentration was significantly correlated with a reduction in pupil area (r = -0.58, P < .001) and pupil diameter (r = -0.57, P < .001). However, when a topical NSAID was given preoperatively, there was no difference in the degree of miosis between the 90% and 150% capsulotomy energy groups. CONCLUSIONS: Pretreatment with a topical NSAID prevented a rise in PGE2, IFN-γ, and IL-6 levels and excessive miosis when a higher capsulotomy energy was used. When a topical NSAID is used preoperatively, it is safe to use higher capsulotomy energy settings (with a low pulse energy femtosecond laser system) to achieve a satisfactory capsulotomy. [J Refract Surg. 2022;38(9):587-594.].


Assuntos
Catarata , Terapia a Laser , Anti-Inflamatórios não Esteroides/uso terapêutico , Catarata/etiologia , Humanos , Interleucina-6/farmacologia , Terapia a Laser/efeitos adversos , Lasers , Miose , Estudos Prospectivos , Prostaglandinas E/farmacologia , Pupila
6.
J Refract Surg ; 37(8): 516-523, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34388069

RESUMO

PURPOSE: To investigate the changes in tear neuromediators and corneal subbasal nerve plexus following small incision lenticule extraction (SMILE) and to study its association with different refractive power of corrections. METHODS: Thirty patients were included for tear neuromediator analysis (40 eyes) and corneal nerve analysis using in vivo confocal microscopy scans (20 eyes). Tear samples were collected preoperatively and 1 week and 1, 3, 6, and 12 months postoperatively and analyzed for the substance P, calcitonin gene-related peptide (CGRP), and nerve growth factor (NGF) concentrations using the enzyme-linked immunosor-bent assay (ELISA). RESULTS: Corneal nerve fiber density (CNFD), corneal nerve fiber length (CNFL), and corneal nerve branch density (CNBD) decreased significantly postoperatively, then gradually increased from 3 months onward, but did not recover to the baseline levels at 12 months. Tear substance P and CGRP levels remained stable over 12 months. Tear NGF levels demonstrated a small peak at 1 week before decreasing significantly compared to preoperative levels at 6 months (P = .03) and 12 months (P = .007). The 1-month reduction in CNFL, tear substance P, and CGRP concentrations were significantly correlated with the corrected spherical equivalent (SE) (r = 0.71 for CNFL; r = -0.33 to -0.52 at different time points for substance P and CGRP, respectively, all P < .05). Compared to the low to moderate myopia group, the high myopia group (corrected SE greater than -6.00 diopters) had a significantly greater decrease in CNFD, significantly higher tear substance P concentrations at 1 week, 1 month, and 6 months, and significantly higher tear CGRP concentrations at 1 and 6 months. CONCLUSIONS: These results provide new insight into the neurobiological responses and their potential implications in corneal nerve damage and recovery after SMILE. High myopia treatment was associated with greater corneal denervation and neuroinflammation. [J Refract Surg. 2021;37(8):516-523.].


Assuntos
Cirurgia da Córnea a Laser , Miopia , Córnea , Substância Própria/cirurgia , Denervação , Humanos , Lasers de Excimer/uso terapêutico , Miopia/cirurgia , Estudos Prospectivos , Lágrimas
7.
Sci Rep ; 11(1): 2448, 2021 01 28.
Artigo em Inglês | MEDLINE | ID: mdl-33510290

RESUMO

Terahertz (THz) technology has emerged recently as a potential novel imaging modality in biomedical fields, including ophthalmology. However, the ocular biological responses after THz electromagnetic exposure have not been investigated. We conducted a rabbit study to evaluate the safety profiles of THz scanning on eyes, at a tissue, cellular, structural and functional level. Eight animals (16 eyes) were analysed after excessive THz exposure (control, 1 h, 4 h, and 1 week after continuous 4-h exposure; THz frequency = 0.3 THz with continuous pulse generated at 40 µW). We found that at all the time points, the corneas and lens remained clear with no corneal haze or lens opacity formation clinically and histopathologically. No thermal effect, assessed by thermographer, was observed. The rod and cone cell-mediated electroretinography responses were not significantly altered, and the corneal keratocytes activity as well as endothelial viability, assessed by in-vivo confocal microscopy, was not affected. Post-exposed corneas, lens and retinas exhibited no significant changes in the mRNA expression of heat shock protein (HSP)90AB1), DNA damage inducible transcript 3 (DDIT3), and early growth response (EGR)1. These tissues were also negative for the inflammatory (CD11b), fibrotic (fibronectin and α-smooth muscle actin), stress (HSP-47) and apoptotic (TUNEL assay) responses on the immunohistochemical analyses. The optical transmittance of corneas did not change significantly, and the inter-fibrillar distances of the corneal stroma evaluated with transmission electron microscopy were not significantly altered after THz exposure. These results provide the basis for future research work on the development of THz imaging system for its application in ophthalmology.


Assuntos
Oftalmologia , Imagem Terahertz/efeitos adversos , Animais , Córnea/diagnóstico por imagem , Córnea/ultraestrutura , Eletrorretinografia , Proteínas do Olho/genética , Proteínas do Olho/metabolismo , Fundo de Olho , Regulação da Expressão Gênica , Inflamação/patologia , Microscopia Confocal , RNA Mensageiro/genética , RNA Mensageiro/metabolismo , Coelhos , Microscopia com Lâmpada de Fenda , Temperatura , Termografia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA