Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Abdom Radiol (NY) ; 2024 Jun 02.
Artigo em Inglês | MEDLINE | ID: mdl-38824474

RESUMO

OBJECTIVE: To compare the ability to depict MRI features of hepatobiliary agents in microvascular infiltration (MVI) of hepatocellular carcinoma (HCC) during different stages of dynamic enhancement MRI. MATERIALS AND METHODS: A retrospective study included 111 HCC lesions scanned with either Gd-EOB-DTPA or Gd-BOPTA. All cases underwent multiphase dynamic contrast-enhanced scanning before surgery, including arterial phase (AP), portal venous phase (PVP), transitional phase (TP), delayed phase (DP), and hepatobiliary phase (HBP). Two abdominal radiologists independently evaluated MRI features of MVI in HCC, such as peritumoral hyperenhancement, incomplete capsule, non-smooth tumor margins, and peritumoral hypointensity. Finally, the results were reviewed by the third senior abdominal radiologist. Chi-square (χ2) Inspection for comparison between groups. P < 0.05 is considered statistically significant. Receiver operating characteristic (ROC) curve was used to evaluate correlation with pathology, and the area under the curve (AUC) and 95% confidence interval (95% CI) were calculated. RESULTS: Among the four MVI evaluation signs, Gd-BOPTA showed significant differences in displaying two signs in the HBP (P < 0.05:0.000, 0.000), while Gd-EOB-DTPA exhibited significant differences in displaying all four signs (P < 0.05:0.005, 0.006, 0.000, 0.002). The results of the evaluations of the two contrast agents in the DP phase with incomplete capsulation showed the highest correlation with pathology (AUC: 0.843, 0.761). By combining the four MRI features, Gd-BOPTA and Gd-EOB-DTPA have correlated significantly with pathology, and Gd-BOPTA is better (AUC: 0.9312vs0.8712). CONCLUSION: The four features of hepatobiliary agent dynamic enhancement MRI demonstrate a good correlation with histopathological findings in the evaluation of MVI in HCC, and have certain clinical significance.

2.
Technol Cancer Res Treat ; 23: 15330338241260331, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38860337

RESUMO

OBJECTIVE: To compare the ability of gadolinium ethoxybenzyl dimeglumine (Gd-EOB-DTPA) and gadobenate dimeglumine (Gd-BOPTA) to display the 3 major features recommended by the Liver Imaging Reporting and Data System (LI-RADS 2018v) for diagnosing hepatocellular carcinoma (HCC). MATERIALS AND METHODS: In this retrospective study, we included 98 HCC lesions that were scanned with either Gd-EOB-DTPA-MR or Gd-BOPTA-M.For each lesion, we collected multiple variables, including size and enhancement pattern in the arterial phase (AP), portal venous phase (PVP), transitional phase (TP), delayed phase (DP), and hepatobiliary phase (HBP). The lesion-to-liver contrast (LLC) was measured and calculated for each phase and then compared between the 2 contrast agents. A P value < .05 was considered statistically significant. The display efficiency of the LLC between Gd-BOPTA and Gd-EOB-DTPA for HCC features was evaluated by receiver operating characteristic (ROC) curve analysis. RESULTS: Between Gd-BOPTA and Gd-EOB-DTPA, significant differences were observed regarding the display efficiency for capsule enhancement and the LLC in the AP/PVP/DP (P < .05), but there was no significant difference regarding the LLC in the TP/HBP. Both Gd-BOPTA and Gd-EOB-DTPA had good display efficiency in each phase (AUCmin > 0.750). When conducting a total evaluation of the combined data across the 5 phases, the display efficiency was excellent (AUC > 0.950). CONCLUSION: Gd-BOPTA and Gd-EOB-DTPA are liver-specific contrast agents widely used in clinical practice. They have their own characteristics in displaying the 3 main signs of HCC. For accurate noninvasive diagnosis, the choice of agent should be made according to the specific situation.


Assuntos
Carcinoma Hepatocelular , Meios de Contraste , Gadolínio DTPA , Neoplasias Hepáticas , Imageamento por Ressonância Magnética , Meglumina , Compostos Organometálicos , Curva ROC , Humanos , Carcinoma Hepatocelular/diagnóstico , Carcinoma Hepatocelular/diagnóstico por imagem , Neoplasias Hepáticas/diagnóstico , Neoplasias Hepáticas/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Masculino , Feminino , Meglumina/análogos & derivados , Pessoa de Meia-Idade , Idoso , Estudos Retrospectivos , Adulto , Aumento da Imagem/métodos , Idoso de 80 Anos ou mais
3.
Biosens Bioelectron ; 102: 365-371, 2018 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-29172145

RESUMO

Bioelectronics platforms are gaining widespread attention as they provide a template to study the interactions between biological species and electronics. Decoding the effect of the electrical signals on the cells and tissues holds the promise for treating the malignant tissue growth, regenerating organs and engineering new-age medical devices. This work is a step forward in this direction, where bio- and electronic materials co-exist on one platform without any need for post processing. We fabricate a freestanding and flexible hydrogel based platform using 3D bioprinting. The fabrication process is simple, easy and provides a flexible route to print materials with preferred shapes, size and spatial orientation. Through the design of interdigitated electrodes and heating coil, the platform can be tailored to print various circuits for different functionalities. The biocompatibility of the printed platform is tested using C2C12 murine myoblasts cell line. Furthermore, normal human dermal fibroblasts (primary cells) are also seeded on the platform to ascertain the compatibility.


Assuntos
Bioimpressão , Técnicas Biossensoriais , Impressão Tridimensional , Engenharia Tecidual , Linhagem Celular , Sobrevivência Celular , Fibroblastos/química , Fibroblastos/citologia , Humanos , Hidrogel de Polietilenoglicol-Dimetacrilato/química , Mioblastos/química , Mioblastos/citologia , Alicerces Teciduais/química
4.
Small ; 13(7)2017 02.
Artigo em Inglês | MEDLINE | ID: mdl-27918645

RESUMO

Responsive nanomaterials have emerged as promising candidates as drug delivery vehicles in order to address biomedical diseases such as cancer. In this work, polymer-based responsive nanoparticles prepared by a supramolecular approach are loaded with doxorubicin (DOX) for the cancer therapy. The nanoparticles contain disulfide bonds within the polymer network, allowing the release of the DOX payload in a reducing environment within the endoplasm of cancer cells. In addition, the loaded drug can also be released under acidic environment. In vitro anticancer studies using redox and pH dual responsive nanoparticles show excellent performance in inducing cell death and apoptosis. Zebrafish larvae treated with DOX-loaded nanoparticles exhibit an improved viability as compared with the cases treated with free DOX by the end of a 3 d treatment. Confocal imaging is utilized to provide the daily assessment of tumor size on zebrafish larva models treated with DOX-loaded nanoparticles, presenting sustainable reduction of tumor. This work demonstrates the development of functional nanoparticles with dual responsive properties for both in vitro and in vivo drug delivery in the cancer therapy.


Assuntos
Sistemas de Liberação de Medicamentos , Nanopartículas/química , Polímeros/química , Ácidos/química , Animais , Antineoplásicos/farmacologia , Doxorrubicina/farmacologia , Doxorrubicina/uso terapêutico , Endocitose/efeitos dos fármacos , Células HeLa , Humanos , Concentração de Íons de Hidrogênio , Larva/efeitos dos fármacos , Neoplasias Hepáticas/tratamento farmacológico , Neoplasias Hepáticas/patologia , Nanopartículas/ultraestrutura , Oxirredução , Espectroscopia de Infravermelho com Transformada de Fourier , Peixe-Zebra/metabolismo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA