Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Cancers (Basel) ; 16(1)2024 Jan 03.
Artigo em Inglês | MEDLINE | ID: mdl-38201653

RESUMO

The incidence of human papillomavirus (HPV)-associated oropharyngeal squamous cell carcinoma (OPSCC) is rising in the West, but little is known in Asia. This study elucidated changes in the incidence and HPV-positive portion of OPSCC in Hong Kong. Data from population-based cancer registry were used to analyze the incidence of OPSCC in association with other head and neck cancers. Archived tumor tissues were tested for HPV. From 1986 to 2020, there was a marked decrease in the incidence of nasopharyngeal and laryngeal cancers, but a persistent increase in OPSCC from 36 cases in 1986 to 116 cases in 2020. The average positive rate for high-risk HPV was 36.1% (112/310) among OPSCC diagnosed in 2010-2020. The HPV-positive rate in recent years was significantly higher than earlier cases (tonsil SCC: 64.7% (55/85) in 2016-2020 vs. 40.4% (19/47) in 2010-2015, p = 0.007). Patients with HPV-positive tonsil cancers were significantly younger than those negative (mean [SD]: 58.9 [9.9] vs. 64.3 [13.3] years, p = 0.006), but no significant difference was observed between genders. A persistent increase in the incidence of oropharyngeal cancer over the last few decades was observed in Hong Kong, which can be explained by the remarkable increase in HPV-positive tonsil cancers.

2.
Magn Reson Imaging ; 79: 112-120, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33600894

RESUMO

We report the design, construction, and initial tests of a hyperpolariser to produce polarised 129Xe and 3He gas for medical imaging of the lung. The hyperpolariser uses the Spin-Exchange Optical Pumping method to polarise the nuclear spins of the isotopic gas. Batch mode operation was chosen for the design to produce polarised 129Xe and polarised 3He. Two-side pumping, electrical heating and a piston to transfer the polarised gas were some of the implemented techniques that are not commonly used in hyperpolariser designs. We have carried out magnetic resonance imaging experiments demonstrating that the 3He and 129Xe polarisation reached were sufficient for imaging, in particular for in vivo lung imaging using 129Xe. Further improvements to the hyperpolariser have also been discussed.


Assuntos
Imageamento por Ressonância Magnética , Isótopos de Xenônio , Calefação , Humanos , Pulmão/diagnóstico por imagem , Masculino , Radiografia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA