Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J Thorac Cardiovasc Surg ; 165(4): 1285-1297.e6, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-34116854

RESUMO

OBJECTIVE: In complex and high-risk aortic root disease, the porcine Freestyle stentless bioprosthesis (Medtronic Inc, Minneapolis, Minn) is an important surgical treatment option. We aimed to determine prevalence and clinical effect of structural and functional abnormalities after full-root Freestyle implantation. METHODS: Our cross-sectional 2-center study combined with clinical follow-up included 253 patients with full-root Freestyle bioprostheses implanted from 1999 to 2017. Patients underwent transthoracic echocardiography (TTE) and contrast-enhanced, electrocardiogram-gated 4-dimensional cardiac computed tomography (4DCT) at median age 70 (interquartile range, 62-75) years. After 4DCT, clinical follow-up continued throughout 2018. Median follow-up was 3.3 years before 4DCT and 1.4 years after. RESULTS: We identified abnormalities in 46% of patients, including pseudoaneurysms (n = 32; 13%), moderate or severe coronary ostial stenosis (n = 54; 21%), and moderate-severe leaflet thickening or reduced leaflet motion (n = 51; 20%). TTE only identified 1 patient with pseudoaneurysm. After 4DCT, the unadjusted hazard ratio for surgical reintervention among patients with abnormal 4DCT was 4.2 (95% confidence interval, 1.2-15.3), in all, 10% required a reintervention. 4DCT abnormalities were associated with a statistically nonsignificant increased risk of death, stroke, or myocardial infarction (hazard ratio obtained using Cox proportional hazards regression analysis, 2.4; 95% confidence interval, 0.7-7.6). In all, 4.0% died, 3.6% had a myocardial infarction, and 2.0% had a stroke. CONCLUSIONS: Structural and functional abnormalities of the aortic root are frequent after Freestyle implantation and TTE appears to be insufficient for follow-up. Abnormalities might be associated with increased risk of reintervention and potentially adverse clinical outcomes. Longer follow-up and larger study populations are needed to further clarify the clinical implications of abnormalities identified with 4DCT.


Assuntos
Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Infarto do Miocárdio , Humanos , Animais , Suínos , Idoso , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Xenoenxertos , Estudos Transversais , Infarto do Miocárdio/cirurgia , Desenho de Prótese , Seguimentos , Resultado do Tratamento
2.
J Thorac Cardiovasc Surg ; 164(6): 1712-1724.e10, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-34452760

RESUMO

OBJECTIVES: Our objective was to examine intermediate-term survival and reinterventions in unselected patients, stratified according to indication, who received a Freestyle (Medtronic Inc, Minneapolis, Minn) bioprosthesis as a full aortic root replacement. METHODS: Data from medical records were retrospectively collected for patients who had aortic root replacement using Freestyle bioprostheses between 1999 and 2018 at 6 North-Atlantic centers. Survival status was extracted from national registries and results stratified according to indication for surgery. RESULTS: We included 1030 implantations in 1008 patients with elective indications for surgery: aneurysm (39.8%), small root (8.3%), and other (13.8%), and urgent/emergent indications: endocarditis (26.7%) and Stanford type A aortic dissection (11.4%). Across indications, 46.3% were nonelective cases and 34.0% were reoperations. Median age was 66.0 (interquartile range, 58.0-71.8) years and median follow-up was 5.0 (interquartile range, 2.6-7.9) years. Thirty-day mortality varied from 2.9% to 27.4% depending on indication. Intermediate survival for 90-day survivors with elective indications were not different from the general population standardized for age and sex (P = .95, .83, and .16 for aneurysms, small roots, and other, respectively). In contrast, patients with endocarditis and type A dissection had excess mortality (P < .001). Freedom from valve reinterventions was 95.0% and 94.4% at 5 and 8 years, respectively. In all, 52 patients (5.2%) underwent reinterventions, most because of endocarditis. CONCLUSIONS: At intermediate term follow-up this retrospective study provides further support for the use of the Freestyle bioprosthesis in the real-world setting of diverse, complex, and often high-risk aortic root replacement and suggests that outcome is determined by patient and disease, rather than by prosthesis, characteristics.


Assuntos
Bioprótese , Endocardite , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Humanos , Idoso , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Estudos Retrospectivos , Xenoenxertos , Desenho de Prótese , Resultado do Tratamento , Endocardite/cirurgia , Seguimentos
3.
Eur J Cardiothorac Surg ; 58(3): 537-543, 2020 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-32236477

RESUMO

OBJECTIVES: Surgical treatment of infective endocarditis (IE) remains a challenge. The Ross procedure offers the benefit of a living substitute in the aortic position but it is a more complex operation which may lead to increased operative risk. The aim of this study was to assess the safety and late outcomes of the Ross procedure for the treatment of active IE. METHODS: From 2000 to 2019, a total of 31 consecutive patients underwent a Ross procedure to treat active IE (mean age 43 ± 12 years, 84% male). All patients were followed up prospectively. Four patients (13%) were intravenous (IV) drug users and 6 patients (19%) had prosthetic IE. The most common infective organism was Streptococcus (58%). Median follow-up was 3.5 (0.9-4.5) years and 100% complete. RESULTS: There were no in-hospital deaths. One patient suffered a postoperative stroke (3%) and 1 patient (3%) required reintervention for bleeding. Three patients had a new occurrence endocarditis: 2 patients were limited to the pulmonary homograft and successfully managed with IV antibiotics, whereas 1 IV drug user patient developed concomitant autograft and homograft endocarditis. Overall, cumulative incidence of IE recurrence was 13 ± 8% at 8 years. The cumulative incidence for autograft endocarditis was 5 ± 4% at 8 years. Two patients (6%) died during follow-up, both from drug overdoses. At 8 years, actuarial survival was 88 ± 8%. CONCLUSIONS: In selected patients with IE, the Ross procedure is a safe and reasonable alternative with good mid-term outcomes. Freedom from recurrent infection on the pulmonary autograft is excellent, labelporting the notion that a living valve in the aortic position provides good resistance to infection. Nevertheless, in IV drug user patients, pulmonary homograft endocarditis remains a challenge. Continued follow-up is needed to ascertain the long-term benefits of this approach.


Assuntos
Endocardite , Valva Pulmonar , Adulto , Valva Aórtica/cirurgia , Autoenxertos , Endocardite/cirurgia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Valva Pulmonar/cirurgia , Reoperação , Transplante Autólogo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA