Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
1.
Europace ; 24(10): 1636-1644, 2022 10 13.
Artigo em Inglês | MEDLINE | ID: mdl-35979596

RESUMO

AIMS: Interventional cardiology procedures may expose patients and staff to considerable radiation doses. We aimed to assess whether exposure to ionizing radiation during catheter ablation of supraventricular tachycardia (SVT) can be completely avoided. METHODS AND RESULTS: In this prospective randomized study, patients with SVT (atrioventricular re-entrant tachycardia n = 94, typical atrial flutter n = 29) were randomly assigned in a 1:1 ratio to catheter ablation with conventional fluoroscopic guidance (CF group) or with the EnSite Precision mapping system [zerofluoro (ZF) group]. Acute procedural parameters, increased stochastic risk of cancer incidence and 6-month follow-up data were assessed. Between May 2019 and August 2020, 123 patients were enrolled. Clinical parameters were comparable. Median procedural time was 60.0 and 58.0 min, median fluoroscopy time and estimated median effective dose were 240 s vs. 0 and 0.38 mSv vs. 0 and arrhythmia recurrence was 5% and 7.9% in the CF and ZF groups, respectively. The acute success rate was 98.4% in both groups. No procedure-related complications were reported. At an average age of 55.5 years and median radiation exposure of 0.38 mSv, the estimate of increased incidence was approximately 1 in 14 084. The estimated mortality rate was 1 per 17 857 exposed persons. CONCLUSIONS: The procedural safety and efficacy of the zero-fluoroscopic approach are similar to those of conventional fluoroscopy-based ablation for atrioventricular nodal re-entrant tachycardia and atrial flutter. Under the assumption of low radiation dose, the excessive lifetime risk of malignancy in the CF group due to electrophysiology procedure is reasonably small, whilst totally reduced in zero fluoroscopy procedures.


Assuntos
Flutter Atrial , Ablação por Cateter , Taquicardia por Reentrada no Nó Atrioventricular , Taquicardia Supraventricular , Arritmias Cardíacas/cirurgia , Flutter Atrial/diagnóstico por imagem , Flutter Atrial/cirurgia , Nó Atrioventricular , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Fluoroscopia/métodos , Humanos , Pessoa de Meia-Idade , Estudos Prospectivos , Taquicardia por Reentrada no Nó Atrioventricular/diagnóstico por imagem , Taquicardia por Reentrada no Nó Atrioventricular/cirurgia , Taquicardia Supraventricular/diagnóstico por imagem , Taquicardia Supraventricular/cirurgia , Resultado do Tratamento
2.
Diagnostics (Basel) ; 12(3)2022 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-35328165

RESUMO

(1) Background: Computer tomography (CT) is an imaging modality used in the pre-planning of radiofrequency catheter ablation (RFA) procedure in patients with cardiac arrhythmias. However, it is associated with a considerable ionizing radiation dose for patients. This study aims to develop and validate low-dose CT scanning protocols of the left atrium (LA) for RFA guidance. (2) Methods: 68 patients scheduled for RFA of atrial fibrillation were sequentially assigned to four groups of ECG-gated scanning protocols, based on the set tube current (TC): Group A (n = 20, TC = 33 mAs), Group B (n = 18, TC = 67 mAs), Group C (n = 10, TC = 135 mAs), and control Group D (n = 20, TC = 600 mAs). We used a 256-row multidetector CT with body weight-dependent tube voltage of 80 kVp (<70 kg), 100 kVp (70−90 kg), and 120 kVp (>90 kg). We evaluated scanning parameters including radiation dose, total scanning procedure time and signal-to-noise ratio (SNR). (3) Results: The average effective radiation dose (ED) was lower in Group A in comparison to Group B, C and D (0.83 (0.76−1.10), 1.55 (1.36−1.67), 2.91 (2.32−2.96) and 9.35 (8.00−10.04) mSv, p < 0.05). The total amount of contrast media was not significantly different between groups. The mean SNR was 6.5 (5.8−7.3), 7.1 (5.7−8.2), 10.8 (10.1−11.3), and 12.2 (9.9−15.7) for Group A, B, C and D, respectively. The comparisons of SNR in group A vs. B and C vs. D were without significant differences. (4) Conclusions: Optimized pre-ablation CT scanning protocols of the LA can reduce an average ED by 88.7%. Three dimensional (3D) models created with the lowest radiation protocol are useful for the integration of electro-anatomic-guided RFA procedures.

3.
Card Electrophysiol Clin ; 13(2): 399-408, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33990278

RESUMO

Intracardiac echocardiography (ICE) is the most practical method for online imaging during electrophysiological procedures. It allows guiding of complex catheter ablation procedures together with electroanatomical mapping systems, either with minimal or with zero fluoroscopy exposure. Besides safe and reproducible transseptal puncture, ICE helps to assess location and contact of the tip of the ablation catheter relative to specific anatomical structures. Another option is visualization of the arrhythmogenic substrate in patients with ventricular arrhythmias. This article describes the clinical utility of ICE in non-fluoroscopic electrophysiology procedures more in detail.


Assuntos
Ecocardiografia/métodos , Técnicas Eletrofisiológicas Cardíacas/métodos , Arritmias Cardíacas/diagnóstico por imagem , Arritmias Cardíacas/cirurgia , Ablação por Cateter/métodos , Fluoroscopia , Coração/diagnóstico por imagem , Humanos , Cirurgia Assistida por Computador/métodos
4.
Artigo em Inglês | MEDLINE | ID: mdl-31645769

RESUMO

AIMS: This study aims to compare procedural parameters and clinical efficacy of remote magnetic navigation (RMN) vs. manual navigation (MAN) approach for radiofrequency ablation (RFA) in patients with atrial fibrillation (AF). METHODS: 146 patients with AF were enrolled in the study. In the RMN group (n=57), patients were treated with the CARTO® 3 in combination with the Niobe ES system. In the MAN group (n=89), ablation was performed with the EnSite Velocity and TactiCath™ Quartz catheter with direct contact force measurement. Procedural time, ablation time, fluoroscopy time, radiation dose and ablation counts were measured and compared between the groups. Recurrence of AF was evaluated after 6 months of follow-up. RESULTS: Mean procedure times (236.87±64.31 vs. 147.22±45.19 min, P<0.05), counts of RF applications (74.30±24.77 vs. 49.15±20.33, P<0.05) and total RFA times (4323.39±1426.69 vs. 2780.53±1157.85 s, P<0.05) were all significantly higher in the RMN than in the MAN group, respectively. In the same order, mean X-ray dose (9722.6±7507.4 vs. 8087.9±6051.5 mGy/cm2, P=0.12) and mean total X-ray exposure time (8.07±4.20 vs. 9.54±5.47 min, P=0.08) were not statistically different. At 6-month follow-up, freedom from AF was similar in RMN and MAN group for paroxysmal (60.8% and 73%, respectively, P=0.42) and persistent AF (69.6% and 75.0%, respectively, P=0.77). CONCLUSIONS: Due to the fact that mid-term clinical outcomes showed no significant differences in AF recurrences between groups and manual ablation strategy provided more favorable results regarding acute procedural parameters, we can conclude that the remote magnetic navigation is not superior to the manual approach.


Assuntos
Fibrilação Atrial/cirurgia , Técnicas Eletrofisiológicas Cardíacas/métodos , Técnicas Eletrofisiológicas Cardíacas/estatística & dados numéricos , Ablação por Radiofrequência/métodos , Ablação por Radiofrequência/estatística & dados numéricos , Sistemas de Navegação Cirúrgica/estatística & dados numéricos , Resultado do Tratamento , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
6.
Indian Heart J ; 70(1): 37-44, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29455785

RESUMO

AIMS: Three-dimensional rotational angiography (3DRA) of the left atrium (LA) and the esophagus is a simple and safe method for analyzing the relationship between the esophagus and the LA during catheter ablation of atrial fibrillation. The purpose of this study is to describe the location of the esophagus relative to the LA and mobility of the esophagus during ablation procedure. METHODS: From 3/2011 to 9/2015, 3DRA of the LA and esophagus was performed in 326 patients before catheter ablation of atrial fibrillation. 3DRAwas performed with visualization of the esophagus via peroral administration of a contrast agent. The positions of the esophagus were determined at the beginning of the procedure, for part of patients also at the end of procedure with contrast esophagography. RESULTS: The most frequent position is behind the center of the LA (91 pts., 31.9%) The least frequent position is behind the right pulmonary veins (27 pts., 9.4%). The average shift of the esophagus position was 3.36±2.15mm, 3.59±2.37mm and 3.67±3.23mm for superior, middle and inferior segment resp. CONCLUSIONS: The position of the esophagus to the LA is highly variable. The most common position of the esophagus relative to the LA is behind the middle and left part of the posterior wall of the LA. The least frequently observed position is behind the right pulmonary veins. No significant position change of esophagus motion from before to after the ablation procedure in the majority (≥95%) of the patients was observed.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Angiografia por Tomografia Computadorizada/métodos , Esôfago/diagnóstico por imagem , Fluoroscopia/métodos , Imageamento Tridimensional/métodos , Cirurgia Assistida por Computador/métodos , Fibrilação Atrial/diagnóstico , Feminino , Átrios do Coração/diagnóstico por imagem , Sistema de Condução Cardíaco/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Estudos Retrospectivos
7.
Europace ; 19(8): 1310-1316, 2017 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-27915264

RESUMO

AIMS: The objective of this study was to evaluate the mobility of the oesophagus and the stability of the three-dimensional (3D) model of the oesophagus using 3D rotational angiography (3DRA) of the left atrium (LA) and the oesophagus, fused with live fluoroscopy during catheter ablation for atrial fibrillation. METHODS AND RESULTS: From March 2015 to September 2015, 3DRA of the LA and the oesophagus was performed in 33 patients before catheter ablation for atrial fibrillation. Control contrast oesophagography was performed every 30 min. The positions of the oesophagograms and the 3D model of the LA and the oesophagus were repeatedly measured and compared with the spine. The average shift of the oesophagus ranged from 2.7 ± 2.2 to 5.0 ± 3.5 mm. The average real-time oesophageal shift ranged from 2.7 ± 2.2 to 3.8 ± 3.4 mm. No significant shift was detected until the 90th minute of the procedure. The average shift of the 3D model of the LA and the oesophagus ranged from 1.4 ± 1.8 to 3.3 ± 3.0 mm (right-left direction) and from 0.9 ± 1.2 to 2.2 ± 1.3 mm (craniocaudal direction). During the 2 h procedure, there were no significant shifts of the model. CONCLUSION: During catheter ablation for atrial fibrillation, there is no significant change in the position of the oesophagus until the 90th minute of the procedure and no significant shift in the 3D model of the LA and the oesophagus. The 3D model of the oesophagus reliably depicts the position of the oesophagus during the entire procedure.


Assuntos
Angiografia/métodos , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Esôfago/diagnóstico por imagem , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/cirurgia , Imageamento Tridimensional , Interpretação de Imagem Radiográfica Assistida por Computador , Radiografia Intervencionista/métodos , Cirurgia Assistida por Computador/métodos , Idoso , Pontos de Referência Anatômicos , Fibrilação Atrial/fisiopatologia , Ablação por Cateter/efeitos adversos , Feminino , Fluoroscopia , Átrios do Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Movimento (Física) , Duração da Cirurgia , Valor Preditivo dos Testes , Estudos Prospectivos , Reprodutibilidade dos Testes , Cirurgia Assistida por Computador/efeitos adversos , Fatores de Tempo , Resultado do Tratamento
8.
J Interv Card Electrophysiol ; 46(2): 81-7, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26971333

RESUMO

PURPOSE: Computed tomography (CT) and 3D rotational angiography (3DRA) of the left atrium (LA) are used to evaluate the esophagus prior to radiofrequency ablation for atrial fibrillation. The aim of this study was to compare preprocedural and periprocedural views of the esophagus and the left atrium. METHODS: From September 2011 to August 2012, 3DRA and CT of the LA were performed on 56 patients before they underwent catheter ablation of atrial fibrillation. The 3DRA was performed periprocedurally, and the CT was performed an average of 20 days prior to the procedure. 3D models of the LA and the esophagus were then segmented on the EP Navigator V 3.1 workstation. Five positions of the esophagus, A-E, in order from left to right, were evaluated. RESULTS: The most common position of the esophagus was behind the left part of the LA (CT, position B (n = 26)) and behind the central part of the LA (3DRA, position C (n = 21)). The maximum shift of the esophagus was three positions, and the average shift was 0.857 ± 0.766 of a position. There was a shift of one position in 44.6 % of the patients, two positions in 17.9 %, and three positions in 1.8 %. A statistically significant difference was found between the positions of the esophagus when the 3DRA and CT evaluations were compared. CONCLUSIONS: The most common position of the esophagus was behind the middle and left part of the LA. The outpatient views of the esophagus obtained before ablation did not reflect the position of the esophagus at the beginning of the procedure.


Assuntos
Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Ablação por Cateter , Esôfago/diagnóstico por imagem , Imageamento Tridimensional , Cirurgia Assistida por Computador , Angiografia por Tomografia Computadorizada , Angiografia Coronária , Esôfago/cirurgia , Feminino , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/cirurgia , Humanos , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Movimento (Física) , Cuidados Pós-Operatórios , Cuidados Pré-Operatórios , Reprodutibilidade dos Testes , Estudos Retrospectivos , Rotação , Sensibilidade e Especificidade , Resultado do Tratamento
9.
Int J Cardiovasc Imaging ; 31(5): 899-904, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25761532

RESUMO

Three-dimensional rotational angiography (3 DRA) is a novel imaging method introduced to guide complex catheter ablations of the left atrium. Our aim was to investigate the feasibility of the method in visualization of left ventricular anatomy and to develop a corresponding protocol for guidance of ventricular tachycardia ablation. We performed 3D rotational angiography in 13 patients using a direct left atrial protocol for data acquisition and the 3D reconstruction of the left ventricle was achieved in all patients. Clinical data comparison has proved lower use of radiation and contrast medium during 3 DRA-guided ablations as compared to CT-guided procedures.


Assuntos
Ablação por Cateter , Angiografia Coronária/métodos , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/cirurgia , Radiografia Intervencionista/métodos , Taquicardia Ventricular/diagnóstico por imagem , Taquicardia Ventricular/cirurgia , Idoso , Meios de Contraste , Estudos de Viabilidade , Feminino , Humanos , Imageamento Tridimensional , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Valor Preditivo dos Testes , Interpretação de Imagem Radiográfica Assistida por Computador , Resultado do Tratamento
10.
Artigo em Inglês | MEDLINE | ID: mdl-25030605

RESUMO

BACKGROUND: Catheter ablation in the left atrium has become a common therapeutic strategy in the management of atrial fibrillation (AF). The high degree of success and safety profile of this procedure is dependent on precise knowledge of the true anatomy in the chamber. This information is imported mostly from cardiac computed tomography. A novel method for imaging the left atrial anatomy is three-dimensional rotational angiography (3DRA). METHODS: The aim of our study was to the compare clinical outcome and safety of catheter ablation for atrial fibrillation guided by 3DRA vs. conventional CT scan. One hundred and twenty-five patients referred for AF catheter ablation at St. Anne's University Hospital Brno were included in the retrospective analysis of clinical outcome within the first year after the procedure. RESULTS: There was a close correlation in overall procedural parameters between the groups. The frequency of recurrent episodes of AF (24% in CT-guided group vs. 27% in 3DRA-guided group, P=0.721) as well as the onset of atypical atrial flutter after the procedure (10% vs. 8%, respectively, P=0.731) were similar in both groups. No difference in the number of patients necessitating repeat ablation (5% vs. 5%, P=0.984) was found. Procedural complications of ablations guided by 3DRA were comparable with those guided by CT (2% vs. 3%, respectively, P=0.568). CONCLUSION: 3DRA has proven to be a safe and simple method for imaging the left atrium and guiding catheter ablation for AF. This approach is anticipated to become a new standard in 3D reconstruction of the left atrium.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Angiografia/métodos , Fibrilação Atrial/diagnóstico por imagem , Ablação por Cateter/efeitos adversos , Feminino , Átrios do Coração/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Duração da Cirurgia , Veias Pulmonares/diagnóstico por imagem , Radiografia Intervencionista/métodos , Recidiva , Tomografia Computadorizada por Raios X/métodos , Resultado do Tratamento
11.
Int J Cardiovasc Imaging ; 30(7): 1207-23, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24964905

RESUMO

Cardiac arrhythmias are a very frequent illness. Pharmacotherapy is not very effective in persistent arrhythmias and brings along a number of risks. Catheter ablation has became an effective and curative treatment method over the past 20 years. To support complex arrhythmia ablations, the 3D X-ray cardiac cavities imaging is used, most frequently the 3D reconstruction of CT images. The 3D cardiac rotational angiography (3DRA) represents a modern method enabling to create CT like 3D images on a standard X-ray machine equipped with special software. Its advantage lies in the possibility to obtain images during the procedure, decreased radiation dose and reduction of amount of the contrast agent. The left atrium model is the one most frequently used for complex atrial arrhythmia ablations, particularly for atrial fibrillation. CT data allow for creation and segmentation of 3D models of all cardiac cavities. Recently, a research has been made proving the use of 3DRA to create 3D models of other cardiac (right ventricle, left ventricle, aorta) and non-cardiac structures (oesophagus). They can be used during catheter ablation of complex arrhythmias to improve orientation during the construction of 3D electroanatomic maps, directly fused with 3D electroanatomic systems and/or fused with fluoroscopy. An intensive development in the 3D model creation and use has taken place over the past years and they became routinely used during catheter ablations of arrhythmias, mainly atrial fibrillation ablation procedures. Further development may be anticipated in the future in both the creation and use of these models.


Assuntos
Arritmias Cardíacas/diagnóstico por imagem , Arritmias Cardíacas/cirurgia , Ablação por Cateter/métodos , Angiografia Coronária/métodos , Sistema de Condução Cardíaco/diagnóstico por imagem , Sistema de Condução Cardíaco/cirurgia , Imageamento Tridimensional , Tomografia Computadorizada Multidetectores/métodos , Interpretação de Imagem Radiográfica Assistida por Computador , Potenciais de Ação , Animais , Arritmias Cardíacas/fisiopatologia , Sistema de Condução Cardíaco/fisiopatologia , Humanos , Valor Preditivo dos Testes , Radiografia Intervencionista , Software , Cirurgia Assistida por Computador
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA