Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
1.
Herzschrittmacherther Elektrophysiol ; 28(2): 212-218, 2017 Jun.
Artigo em Alemão | MEDLINE | ID: mdl-28488109

RESUMO

Ventricular tachycardias (VT) in patients with structural heart diseases have predominantly a scar-associated reentry mechanism so that substrate-based ablation approaches also have to be used in nearly all procedures. In many VT cases-especially in nonischemic cardiomyopathy (NICM) and arrhythmogenic right ventricular cardiomyopathy-a critical epicardial substrate can be identified as an essential component of the reentry circuit so that for the ablation-based modification of the substrate in these cases an epicardial approach is necessary. In cases of redo-VT ablation procedures in ischemic cardiomyopathy (after a previously endocardial ablation), an epicardial approach should also be considered. There are also cases in whom no endocardial substrate can be identified and an isolated epicardial substrate can be identified. Worldwide epicardial VT ablations are usually performed after gaining epicardial access using subxyphoidal puncture. The results of recent studies show a higher efficiency with stabilization of cardiac rhythm and reduction of recurrent VT episodes (about 70% event-free survival at the 2­year follow-up) after endo-plus epicardial substrate modification. In electrical storm cases, an early epicardial VT ablation approach also appears to be relevant, especially in NICM. Epicardial instrumentation and ablation represents a complex procedure which should only be performed in experienced centers with cardiac surgery back-up. In these experienced centers, the complications rate is less than 5%.


Assuntos
Ablação por Cateter , Pericárdio/cirurgia , Taquicardia por Reentrada no Nó Atrioventricular/cirurgia , Cardiomiopatias/diagnóstico , Cardiomiopatias/fisiopatologia , Cardiomiopatias/cirurgia , Cicatriz/diagnóstico , Cicatriz/fisiopatologia , Cicatriz/cirurgia , Angiografia Coronária , Mapeamento Epicárdico , Fidelidade a Diretrizes , Humanos , Imageamento por Ressonância Magnética , Pericárdio/fisiopatologia , Reoperação , Taquicardia por Reentrada no Nó Atrioventricular/diagnóstico , Taquicardia por Reentrada no Nó Atrioventricular/fisiopatologia , Resultado do Tratamento
2.
Radiologe ; 53(10): 886-95, 2013 Oct.
Artigo em Alemão | MEDLINE | ID: mdl-24129987

RESUMO

Percutaneous transcatheter aortic valve implantation (TAVI) is an established alternative to open heart surgery in patients with severe aortic stenosis (AS) unsuitable for conventional aortic valve replacement due to comorbidities with a high perioperative risk or contraindications. Preprocedural imaging plays a major role for adequate determination of indications and prosthesis selection, prosthesis sizing and therefore for a reduction of periprocedural complications. Besides Doppler echocardiography which is mainly used for grading of the severity of aortic valve stenosis and peri-interventional imaging, cardiac computed tomography (CCT) is the imaging modality of choice. The CCT procedure not only allows for reliably assessment and measuring of the complex 3-dimensional geometry of the aortic root but also for the aorta and the peripheral vessels used as potential access paths.


Assuntos
Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Cateterismo Cardíaco/métodos , Implante de Prótese de Valva Cardíaca/métodos , Radiografia Intervencionista/métodos , Cirurgia Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Humanos , Cuidados Pré-Operatórios/métodos , Prognóstico
3.
Rofo ; 184(10): 941-9, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23999787

RESUMO

UNLABELLED: Transcatheter aortic valve implantation (TAVI) is currently considered an acceptable alternative for the treatment of patients with severe aortic stenosis and a high perioperative risk or a contraindication for open surgery. The benefit of TAVI significantly outweighs the risk of the procedure in patients requiring treatment that are not suitable for open surgery, and leads to a lower mortality in the one-year follow-up. The absence of a direct view of the aortic root and valve remains a challenge for the transcatheter approach. While direct inspection of the aortic valve during open surgery allows an adequate prosthesis choice, it is crucial for TAVI to know the individual anatomical details prior to the procedure in order to assure adequate planning of the procedure and proper prosthesis choice and patient selection. Among the imaging modalities available for the evaluation of patients prior to TAVI, computed tomography (CT) plays a central role in patient selection. CT reliably visualizes the dimensions of the aortic root and allows a proper choice of the prosthesis size. The morphology of the access path and relevant comorbidities can be assessed. The present review summarizes the current state of knowledge regarding the value of CT in the evaluation of patients prior to TAVI. KEY POINTS: CT plays a central role in patient selection and planning prior to TAVI. ▶ CT reliably detects the dimensions of the aortic root including the size of the aortic annulus, the degree of valve calcification and the morphology of the access routes. ▶ CT provides a more accurate measurement of the aortic annulus than 2D TEE and CT is the only imaging modality that allows a risk assessment for paravalvular leakages based on the calcification of the aortic valve.


Assuntos
Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Cateterismo Cardíaco , Implante de Prótese de Valva Cardíaca , Processamento de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Tomografia Computadorizada Multidetectores/métodos , Radiografia Intervencionista , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Calcinose/diagnóstico por imagem , Calcinose/cirurgia , Humanos , Planejamento de Assistência ao Paciente , Seleção de Pacientes , Complicações Pós-Operatórias/diagnóstico por imagem , Complicações Pós-Operatórias/prevenção & controle , Cuidados Pré-Operatórios , Desenho de Prótese , Ajuste de Prótese
4.
Rofo ; 185(4): 373-5, 2013 Apr.
Artigo em Alemão | MEDLINE | ID: mdl-23440639
5.
Minerva Cardioangiol ; 61(1): 33-43, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23381378

RESUMO

Transcatheter aortic valve implantation (TAVI) is a new technology, which is rapidly growing to a routine procedure amenable for patients with symptomatic aortic valve stenosis and higher than average risk for conventional aortic valve surgery. The crucial disadvantage of TAVI remains the not well foreseeable risk of more than trivial degree of paravalvular leakage and a high rate of atrioventricular block and consecutive pacemaker implantation. In addition, current implantation techniques do not allow controlling the rotation of first-generation devices that might be beneficial regarding optimal physiological valve performance, optimal coronary flow and avoidance of placement of covered commissures in front of the coronary ostia. These shortcomings had pushed the development of second-generation self-expandable nitinol-based devices for subcoronary implantation that aim a reduction of paravalvular leak and AV-block by anatomical orientated positioning into the aortic root. This review focuses on the description of three different TAVI concepts, which are presently under early clinical evaluation, or have recently received commercial approval, using the transapical approach.


Assuntos
Valva Aórtica/cirurgia , Cateterismo Cardíaco/instrumentação , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/métodos , Valva Aórtica/anatomia & histologia , Desenho de Equipamento , Humanos
6.
Rofo ; 185(10): 941-9, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24490256

RESUMO

UNLABELLED: Transcatheter aortic valve implantation (TAVI) is currently considered an acceptable alternative for the treatment of patients with severe aortic stenosis and a high perioperative risk or a contraindication for open surgery. The benefit of TAVI significantly outweighs the risk of the procedure in patients requiring treatment that are not suitable for open surgery, and leads to a lower mortality in the one-year follow-up. The absence of a direct view of the aortic root and valve remains a challenge for the transcatheter approach. While direct inspection of the aortic valve during open surgery allows an adequate prosthesis choice, it is crucial for TAVI to know the individual anatomical details prior to the procedure in order to assure adequate planning of the procedure and proper prosthesis choice and patient selection. Among the imaging modalities available for the evaluation of patients prior to TAVI, computed tomography (CT) plays a central role in patient selection. CT reliably visualizes the dimensions of the aortic root and allows a proper choice of the prosthesis size. The morphology of the access path and relevant comorbidities can be assessed. The present review summarizes the current state of knowledge regarding the value of CT in the evaluation of patients prior to TAVI. CT plays a central role in patient selection and planning prior to TAVI. CT reliably detects the dimensions of the aortic root including the size of the aortic annulus, the degree of valve calcification and the morphology of the access routes. KEY POINTS: CT plays a central role in patient selection and planning prior to TAVI. CT reliably detects the dimensions of the aortic root including the size of the aortic annulus, the degree of valve calcification and the morphology of the access routes. CT provides a more accurate measurement of the aortic annulus than 2D TEE and CT is the only imaging modality that allows a risk assessment for paravalvular leakages based on the calcification of the aortic valve.


Assuntos
Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Cateterismo Cardíaco/métodos , Implante de Prótese de Valva Cardíaca/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Cuidados Pré-Operatórios/métodos , Tomografia Computadorizada por Raios X/métodos , Idoso , Idoso de 80 Anos ou mais , Aorta Abdominal/diagnóstico por imagem , Calcinose/diagnóstico por imagem , Calcinose/cirurgia , Angiografia Coronária , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/cirurgia , Feminino , Artéria Femoral/diagnóstico por imagem , Humanos , Artéria Ilíaca/diagnóstico por imagem , Complicações Intraoperatórias/diagnóstico por imagem , Complicações Intraoperatórias/cirurgia , Masculino , Seleção de Pacientes , Desenho de Prótese , Ajuste de Prótese/métodos , Seio Aórtico/diagnóstico por imagem , Seio Aórtico/cirurgia
7.
Clin Res Cardiol ; 100(4): 343-50, 2011 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-21088843

RESUMO

AIM: To evaluate changes of right ventricular (RV) parameters in follow-up examinations after corrected tetralogy of Fallot (TOF) by cardiac magnetic resonance (CMR). METHODS: CMR was performed twice within 4 years in 45 patients using a 1.5 T scanner. RV-volumes and pulmonary-regurgitant-fractions (PRF) were calculated from standard cine-sequences and flow-sensitive gradient-echo images, respectively. Patients were divided into two groups depending on the post-operative (po) interval (group 1 ≤5 years po; group 2 >5 years po) and subgroups depending on type of surgery (transannular vs. non-transannular). Patient groups were compared among each other and differences between 1st and 2nd CMR were assessed. Furthermore, patients were compared with 25 healthy volunteers. RESULTS: Compared with controls RV-size was increased (group 1: p = 0.007; group 2: p < 0.001) and RV function decreased (group 1: p = 0.02; group 2: p < 0.001) in po TOF-patients. PRF was higher in group 2 compared with group 1 (p = 0.04) and significant changes of PRF between 1st and 2nd CMR were found in group 2 (p < 0.01), but not in group 1 (p = 0.29). Compared with the non-transannular subgroup, PRF (p < 0.001) and RV end-diastolic-volume index (RV-EDVI) (p = 0.03) were significantly higher in patients with a transannular patch, EDVI increased between 1st and 2nd CMR. After correction, no significant changes of RV myocardial mass index (RV-MMI) were found. CONCLUSION: After correction of TOF, RV-size, RV-muscle mass (RV-MM) was increased and ejection fraction decreased in "early" follow-up already. Whereas these parameters can remain stable over a long time period, the PRF significantly increased in "late" follow-up dependent on the po interval. Overall, transannular patching went along with higher PRF and bigger RV-size as well as a greater dynamic of these parameters in the time course, which makes this subgroup highly in need of regular follow-up examinations for the optimal timing of re-interventions. In contrast, the increased RV-MM demonstrated no regression po.


Assuntos
Tetralogia de Fallot/fisiopatologia , Tetralogia de Fallot/cirurgia , Função Ventricular Direita/fisiologia , Volume Cardíaco , Estudos de Casos e Controles , Criança , Feminino , Seguimentos , Ventrículos do Coração/fisiopatologia , Humanos , Imageamento por Ressonância Magnética , Masculino , Insuficiência da Valva Pulmonar , Estudos Retrospectivos , Fatores de Tempo , Adulto Jovem
8.
Radiologe ; 51(1): 15-22, 2011 Jan.
Artigo em Alemão | MEDLINE | ID: mdl-21165591

RESUMO

Transposition of the great arteries (TGA) is a rare disease representing not more than 3-5% of all congenital heart diseases. TGA is a cardiac anomaly in which the aorta arises entirely or largely from the morphological right ventricle and the pulmonary artery from the morphological left ventricle. This is called a ventriculo-arterial discordant connection and when accompanied by an atrio-ventricular concordant connection it is called a complete or D-transposition (D-TGA). The terms congenitally corrected TGA (ccTGA) or L-TGA describe an atrio-ventricular discordant connection. In D-TGA survival can only be achieved if additional shunting is simultaneously present, which possibly has to be created post-natal by the so-called Rashkind maneuver.Nowadays, an early anatomic correction using the arterial switch operation is the treatment of choice. Up to the 1980s, an atrial switch operation according to Senning/Mustard was performed. Apart from echocardiography the imaging modality of choice is usually MRI to assess the complex postoperative anatomy, viability of the myocardium and to perform a volumetric and functional assessment, including MR flow measurements. Multidetector computed tomography (MDCT) is used if there are contraindications to MRI or if an assessment of cardiac and especially coronary anatomy is the main interest.


Assuntos
Procedimentos Cirúrgicos Cardiovasculares/métodos , Revascularização Miocárdica/métodos , Cirurgia Assistida por Computador/métodos , Transposição dos Grandes Vasos/diagnóstico , Transposição dos Grandes Vasos/cirurgia , Humanos , Cuidados Pós-Operatórios/métodos , Cuidados Pré-Operatórios/métodos
9.
Rofo ; 182(12): 1082-90, 2010 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-21104596

RESUMO

PURPOSE: To compare lesion volume determination by applying diameter measurement and three different segmentation algorithms at different slice thicknesses reconstructed from computed tomography (CT) of a phantom model for hepatic colorectal metastases. MATERIALS AND METHODS: Based on CT attenuation measurements obtained retrospectively from 20 patients with colorectal liver metastases, a phantom model was designed with a sponge soaked with a dilution of contrast agent and 6 embedded polyamide spheres (diameter, 8 - 30 mm) to simulate the contrast behavior of liver metastases. CT scans were obtained and reconstructed at different slice thicknesses (0.625/1.25/2.5/3.75 mm; increment, 1). One observer performed software-aided volume determination using the maximum diameter, manual segmentation, seed point method, and threshold method six times for each lesion in a randomized order. Statistical analysis revealed the absolute and relative differences from the actual lesion volumes and the intraobserver differences as well as the influence of slice thickness for each method. RESULTS: The mean relative differences of the seed point method (1.2 - 5.9%) and manual segmentation (2.6 - 4.9%) were significantly lower than the threshold method (5.4 - 12.8%) and diameter measurement (12.3 - 18.5%; p < 0.01). Volume determination by manual segmentation and the seed point method benefited from the use of thin-slice CT datasets. The intraobserver variation was lowest when using the manual segmentation (1.5 - 3.3%) and the seed point method (2.2 - 3.9%; p < 0.001). CONCLUSION: Manual segmentation and the seed point method for thin CT slices were the methods with the lowest volume differences and intraobserver variation.


Assuntos
Neoplasias Colorretais/diagnóstico por imagem , Aumento da Imagem/métodos , Imageamento Tridimensional/métodos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/secundário , Imagens de Fantasmas , Tomografia Computadorizada Espiral/métodos , Carga Tumoral/fisiologia , Humanos , Fígado/diagnóstico por imagem , Variações Dependentes do Observador , Sensibilidade e Especificidade , Software
10.
Eur J Radiol ; 70(1): 155-64, 2009 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-18289819

RESUMO

OBJECTIVE: To analyze the spectrum of findings in indirect MR-arthrography following osteochondral autograft transfer system (OATS) and crushed bone graft using a magnetic resonance imaging (MRI) scoring and grading system in relation to histology as the standard of reference. MATERIALS AND METHODS: Iatrogenic lesions were set at ovine condylar facets (n=6/group), treated with OATS or crushed bone graft. 1.5 T MRI was performed 6 months after surgery using PD-weighted (w fat saturated (fs) fast spin echo (FSE), T1-w 2D, and 3D fs gradient echo (GE) sequences 30 min. after i.v. Gd-DTPA administration and passive joint exercise. The repair tissue was evaluated by two independent radiologists. The MR findings were compared to histology. RESULTS: In all cases, MRI and histologic grading correlated well and showed significant superior repair in OATS at 6 months (p<0.05), reproducing the original articular contour and a good subchondral restoration. FsT1-w3DGE proved most appropriate identifying characteristic post-operative findings: the OATS group demonstrated bone marrow edema at the donor site and the graft/host interface showed significant enhancement in indirect MR-arthrography, indicating fibrocartilage. After crushed bone graft, we found an irregular structure and significant contrast uptake, consistent with remnants of bone grafts surrounded by inflammatory tissue. CONCLUSION: Indirect MR-arthrography is an accurate, non-invasive monitoring tool following OATS and crushed bone graft as the MRI scoring and grading system allows a reliable evaluation of normal and pathological osteochondral repair with a high histologic correlation.


Assuntos
Substitutos Ósseos/uso terapêutico , Transplante Ósseo/instrumentação , Cartilagem Articular/cirurgia , Colágeno/uso terapêutico , Fraturas de Cartilagem/patologia , Fraturas de Cartilagem/cirurgia , Imageamento por Ressonância Magnética/métodos , Animais , Transplante Ósseo/métodos , Cartilagem Articular/lesões , Cartilagem Articular/patologia , Membranas Artificiais , Ovinos , Estatística como Assunto , Resultado do Tratamento
11.
Acta Radiol ; 48(8): 821-30, 2007 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-17924212

RESUMO

BACKGROUND: Management of patients after locally ablative treatment of liver metastases requires exact information about local control and systemic disease status. To fulfill these requirements, whole-body imaging using positron emission tomography with (18)F-fluorodeoxyglucose (FDG-PET) is a promising alternative to morphologic imaging modalities such as computed tomography (CT) and magnetic resonance imaging (MRI). PURPOSE: To evaluate FDG-PET for the assessment of local control and systemic disease in patients with clinical suspicion of tumor progression after laser-induced thermotherapy (LITT) of colorectal liver metastases. MATERIAL AND METHODS: In 21 patients with suspicion of progressive disease after LITT, whole-body FDG-PET was performed. The presence of viable tumor within treated lesions, new liver metastases, and extrahepatic disease was evaluated visually and semiquantitatively (maximal standard uptake value [SUV(max)], tumor-to-normal ratio [T/N]). The standard of reference was histopathology (n = 25 lesions) and/or clinical follow-up (>12 months) including contrast-enhanced MRI of the liver. RESULTS: Among 54 metastases treated with LITT, 29 had residual tumor. Receiver operating characteristic (ROC) analysis of SUV(max) (area under the curve (AUC) 0.990) and T/N (AUC 0.968) showed a significant discrimination level of negative or positive lesion status with an equal accuracy of 94% (51/54). The overall accuracy of visual FDG-PET was 96% (52/54), with one false-negative lesion among six examined within 3 days after LITT, and one false-positive lesion examined 54 days after LITT. In the detection of new intra- and extrahepatic lesions, FDG-PET resulted in correct alteration of treatment strategy in 43% of patients (P = 0.007). CONCLUSION: FDG-PET is a promising tool for the assessment of local control and whole-body restaging in patients with clinical suspicion of tumor progression after locally ablative treatment of colorectal liver metastases with LITT.


Assuntos
Neoplasias Colorretais/patologia , Fluordesoxiglucose F18 , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/secundário , Neoplasia Residual/diagnóstico por imagem , Tomografia por Emissão de Pósitrons/métodos , Adulto , Idoso , Ablação por Cateter , Erros de Diagnóstico , Progressão da Doença , Feminino , Seguimentos , Humanos , Hipertermia Induzida/métodos , Terapia a Laser/métodos , Neoplasias Hepáticas/cirurgia , Masculino , Pessoa de Meia-Idade , Curva ROC , Sensibilidade e Especificidade
12.
Acta Radiol ; 47(2): 121-9, 2006 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-16604957

RESUMO

PURPOSE: To characterize cystic pancreatic lesions and tumors with magnetic resonance imaging (MRI), and to assess the value of morphological criteria in differentiating pseudocysts versus cystic tumors and benign versus malignant cystic tumors. MATERIAL AND METHODS: Twenty-three patients with cystic pancreatic tumors or lesions underwent plain and contrast-material-enhanced MRI, including magnetic resonance cholangiopancreatography (MRCP). The MR findings were characterized and analyzed by two readers, and the role of various imaging criteria and combinations thereof for final lesion assignment were assessed. Final diagnoses were obtained from the results of open surgery (n = 19) and/or biopsy (n = 4). RESULTS: Final diagnoses included cystic tumors (n = 11) and pseudocysts (n = 12). The lesions were located in the head (56%) and body or tail (44%). Lesion diameters ranged from 7 to 50 mm. Various lesion contrast enhancement patterns were observed for both benign and malignant lesions. Serous cystadenomas were located in the head, they were lobulated, and had wall diameters < or = 2 mm; with the combination of these characteristics all patients with serous cystadenoma could be identified, whereas in no other patient was this constellation observed. CONCLUSION: MRI facilitated the diagnosis of serous cystadenomas, although no definite morphologic criterion for the differentiation between pseudocysts and mucinous cystadenomas was identified. In consideration of the substantial therapeutic consequences, either diagnostics in unclear cystic pancreatic lesions should comprise cyst fluid analysis if necessary, or eligible patients should be referred for surgical resection.


Assuntos
Imageamento por Ressonância Magnética/métodos , Cisto Pancreático/diagnóstico , Neoplasias Pancreáticas/diagnóstico , Adulto , Idoso , Colangiopancreatografia por Ressonância Magnética , Meios de Contraste , Diagnóstico Diferencial , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade
13.
Rofo ; 177(3): 338-43, 2005 Mar.
Artigo em Alemão | MEDLINE | ID: mdl-15719294

RESUMO

PURPOSE: To compare virtual with flexible bronchoscopy for the detection of bronchial stenoses. MATERIALS AND METHODS: In a retrospective study, we compared the results of 26 patients, who had clinical suspected pathologies of the tracheobronchial airways and underwent both flexible bronchoscopy and multislice CT with 3D surface rendering of the airways. Flexible bronchoscopy and virtual bronchoscopy were compared as to the rate of detecting bronchial stenoses. For statistical analysis, we divided the tracheobronchial tree in the following sections: trachea, 2 main bronchi, 6 lobar bronchi, 18 segmental bronchi and 36 subsegmental bronchi, corresponding to 63 bronchial sections for each patient (on average) and a total of 1638 bronchial sections for all 26 patients. We graded the bronchial stenosis as less than 50 %, as 50 to 95 % and as complete obstruction. RESULTS: Virtual bronchoscopy detected 25 bronchial stenoses, while flexible bronchoscopy only revealed 17 stenoses. Stenoses with a diameter less than 50 % were found with virtual bronchoscopy 14 times and with flexible bronchoscopy 10 times. Stenoses with a diameter between 50 and 95 % were detected 7 and 4 times, respectively, and complete obstructions 4 and 3 times, respectively. Tracheobronchial stenoses were well recognized with virtual bronchoscopy. Moreover, the virtual method enabled the visualization of high-grade stenoses and post-stenotic areas that could not be passed by the fiberoptic bronchoscope. Virtual bronchoscopy detected stenoses at a higher rate but the difference was not statistically significant (stenoses < 50 %: p = 0.352, 50 - 95 %: p = 0.339, complete obstruction: p = 0.696). CONCLUSION: Virtual bronchoscopy is a useful non-invasive method for the diagnostic evaluation of the tracheobronchial tree. In comparison with flexible bronchoscopy, virtual bronchoscopy is superior in revealing high-grade stenoses and visualizing post-stenotic areas.


Assuntos
Broncopatias/diagnóstico , Broncoscopia/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Broncopatias/diagnóstico por imagem , Neoplasias Brônquicas/diagnóstico , Neoplasias Brônquicas/diagnóstico por imagem , Bronquite/diagnóstico , Bronquite/diagnóstico por imagem , Distribuição de Qui-Quadrado , Constrição Patológica/diagnóstico , Constrição Patológica/diagnóstico por imagem , Diagnóstico Diferencial , Neoplasias Esofágicas/diagnóstico , Neoplasias Esofágicas/diagnóstico por imagem , Feminino , Tecnologia de Fibra Óptica , Humanos , Processamento de Imagem Assistida por Computador , Imageamento Tridimensional , Masculino , Pessoa de Meia-Idade , Pneumonia/diagnóstico , Pneumonia/diagnóstico por imagem , Estudos Retrospectivos , Tomografia Computadorizada Espiral , Estenose Traqueal/diagnóstico , Estenose Traqueal/diagnóstico por imagem
14.
Am J Vet Res ; 62(1): 130-5, 2001 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-11197551

RESUMO

OBJECTIVE: To perform polymerase chain reaction (PCR) analysis on paraffin-embedded myocardium from dogs with dilated cardiomyopathy (DCM) and dogs with myocarditis to screen for canine parvovirus, adenovirus types 1 and 2, and herpesvirus. SAMPLE POPULATION: Myocardial specimens from 18 dogs with an antemortem diagnosis of DCM and 9 dogs with a histopathologic diagnosis of myocarditis were evaluated. PROCEDURE: Paraffin-embedded myocardial specimens were screened for viral genome by PCR analysis. Positive-control specimens were developed from cell cultures as well as paraffin-embedded tissue specimens from dogs with clinical and histopathologic diagnoses of viral infection with canine parvovirus, adenovirus types 1 and 2, and herpesvirus. The histologic characteristics of all myocardial specimens were classified regarding extent, location, and type of inflammation and fibrosis. RESULTS: Canine adenovirus type 1 was amplified from 1 specimen from a dog with DCM. Canine parvovirus, adenovirus type 2, and herpesvirus were not amplified from any myocardial specimens. Histologic analysis of specimens from dogs with DCM revealed variable amounts of fibrosis; myocardial inflammation was observed in 1 affected dog. Histopathologic analysis of specimens from dogs with myocarditis disclosed variable degrees of inflammation and fibrosis. CONCLUSIONS AND CLINICAL RELEVANCE: Viral agents canine parvovirus, adenovirus types 1 and 2, and herpesvirus are not commonly associated with DCM or active myocarditis in dogs. Additional studies evaluating for nucleic acid from viruses that less commonly affect dogs or different types of infectious agents may be warranted to gain insight into the cause of DCM and myocarditis in dogs.


Assuntos
Cardiomiopatia Dilatada/veterinária , Doenças do Cão/virologia , Coração/virologia , Miocardite/veterinária , Miocárdio/patologia , Parvovirus Canino/isolamento & purificação , Vírus/isolamento & purificação , Animais , Cardiomiopatia Dilatada/patologia , Cardiomiopatia Dilatada/virologia , Doenças do Cão/patologia , Cães , Fibrose , Genoma Viral , Inflamação , Miocardite/patologia , Miocardite/virologia , Parvovirus Canino/genética , Reação em Cadeia da Polimerase/métodos
15.
J Am Vet Med Assoc ; 218(3): 376-80, 360, 2001 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-11201563

RESUMO

Congestive heart failure was diagnosed in a 27-year-old Indian ringneck parakeet with exercise-induced dyspnea. A grade IV/VI holosystolic murmur that radiated to the right sternal area was auscultated over the left side of the sternum. Radiography revealed progressive cardiomegaly, hepatomegaly, pulmonary edema, and accumulation of fluid within the coelomic cavity. Echocardiography revealed biatrial enlargement and enlargement of the right ventricle. Doppler recording revealed high velocity left and right atrioventricular valve regurgitation. Treatment with digoxin and furosemide alleviated clinical signs for approximately 10 months. Gross postmortem examination revealed cardiac enlargement and eccentric hypertrophy of both ventricles on cross-section. Pulmonary congestion and edema, hepatomegaly, hepatic congestion, and ascites were also evident. Histologic examination of the heart revealed myxomatous degeneration of the left atrioventricular valve, muscular hypertrophy of the right atrioventricular valve, and biventricular chronic myofiber degeneration and necrosis.


Assuntos
Doenças das Aves/patologia , Insuficiência Cardíaca/veterinária , Doenças das Valvas Cardíacas/veterinária , Periquitos , Animais , Digoxina/administração & dosagem , Digoxina/sangue , Digoxina/uso terapêutico , Diuréticos/administração & dosagem , Diuréticos/uso terapêutico , Ecocardiografia Doppler em Cores/veterinária , Eletrocardiografia/veterinária , Evolução Fatal , Furosemida/administração & dosagem , Furosemida/uso terapêutico , Auscultação Cardíaca/veterinária , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/tratamento farmacológico , Doenças das Valvas Cardíacas/complicações , Doenças das Valvas Cardíacas/tratamento farmacológico , Radiografia Torácica/veterinária , Disfunção Ventricular/complicações , Disfunção Ventricular/tratamento farmacológico , Disfunção Ventricular/veterinária
16.
Contemp Top Lab Anim Sci ; 39(2): 34-9, 2000 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-11487238

RESUMO

Arterial blood pressure in cats can be measured by direct or indirect techniques. Most direct measurement techniques require sedation or anesthesia, which decreases blood pressure. The restraint and human intervention needed for indirect techniques cause blood pressure to increase. These limitations make the accurate assessment of blood pressure and the response to antihypertensive medications difficult to interpret. Radiotelemetry allows for direct measurement of the arterial blood pressure and heart rate without sedation, anesthesia, or animal handling during measurement. A surgical technique for the placement of radiotelemetry catheters and the complications associated with the technique have not been described in cats. Our purpose is to provide a detailed description of the placement of the modified implant model TA11PA-C40 (Data Sciences International), with accompanying illustrations, and to discuss complications associated with the procedure. Radiotelemetry catheters were surgically placed in the left femoral artery of 12 cats. The surgical procedure was completed within 50 min, and no surgical complications occurred in any cat. The radiotelemetry catheters were used for an average of 6.5 weeks (range, 5.5 to 9.5 weeks). This technique allows for long-term monitoring of ambulatory blood pressure and heart rate in the research setting. This methodology is especially useful for studies of the pathophysiology of hypertension and assessment of the efficacy of antihypertensive medications.


Assuntos
Cateterismo Periférico/veterinária , Gatos/fisiologia , Rádio , Procedimentos Cirúrgicos Operatórios/veterinária , Telemetria/veterinária , Animais , Monitorização Ambulatorial da Pressão Arterial/veterinária , Monitores de Pressão Arterial/veterinária , Cateterismo Periférico/métodos , Feminino , Artéria Femoral/cirurgia , Frequência Cardíaca/fisiologia , Masculino , Telemetria/instrumentação , Telemetria/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA