Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 44
Filtrar
1.
Eur Heart J Case Rep ; 6(11): ytac435, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36451807

RESUMO

Background: Due to the increasing prevalence of Kawasaki Disease (KD) in adulthood, the number of women considering pregnancy is growing. There are limited data on the course of pregnancy in KD with coronary artery involvement. Case summary: We report on the pregnancy outcome of a 30-year-old woman with KD who was successfully resuscitated for ventricular tachycardia 3 years before. At that time, bypass surgery and later implantable cardioverter-defibrillator implantation were performed because of thrombotically occluded calcified giant coronary aneurysms. The pregnancy course was initially uncomplicated, however, at 31 weeks of gestation, left-sided breast cancer was diagnosed. Weighing maximum therapeutic efficacy against acceptable foetal and maternal cardiotoxic risk, our multidisciplinary team decided on neoadjuvant chemotherapy. The mother and foetus tolerated the therapy well. However, at 36 weeks of gestation, due to HELLP (haemolysis, elevated liver, low platelets) syndrome, a caesarean section had to be performed. The newborn was healthy with good APGAR (appearance, pulse, grimace, activity, respiration) scores. Three weeks after delivery, chemotherapy was restarted and at Week 4 after the caesarean section, the tumour was no more detectable. Discussion: We discuss data on pregnancy and KD and outline that pregnancy can be considered if the clinical condition is good and left ventricular function is preserved. We also address possible therapeutic approaches and care for breast cancer in pregnancy and coexisting cardiovascular disease. The extraordinary importance of interdisciplinary cooperation between different disciplines in such complex clinical disease conditions is emphasized.

2.
Radiol Case Rep ; 16(8): 2112-2118, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34158905

RESUMO

This case report presents the diagnostic workup of liver malignancy incidentally detected in a 72-year-old male patient on routine body computed tomography angiography (CTA) performed for planning transcatheter aortic valve implantation (TAVI). The patient initially presented to an outside hospital with chest discomfort, where routine diagnostic procedures in the emergency room revealed grade III aortic valve stenosis. Routine CTA for TAVI planning in our department then revealed tumor thrombosis of the portal vein suspicious for hepatic malignancy. In contrast-enhanced ultrasound (CEUS) only the left hepatic lobe was inhomogeneously transformed with early arterial contrast enhancement. Magnetic resonance imaging (MRI) confirmed a primary hepatic malignancy involving the left liver. Transcutaneous biopsy with ultrasound guidance established the diagnosis of hepatocellular carcinoma (HCC). Incidental findings may be of prognostic relevance for the patient and in a number of cases, TAVI can be a prerequisite for the appropriate therapy.

3.
EuroIntervention ; 15(17): 1506-1513, 2020 Apr 17.
Artigo em Inglês | MEDLINE | ID: mdl-31929100

RESUMO

AIMS: The aim of our study was to compare the impact of implantation of a balloon-expandable transcatheter valve into the inferior vena cava (CAVI) on exercise capacity with optimal medical therapy (OMT) in patients with severe tricuspid regurgitation (TR) and high surgical risk. METHODS AND RESULTS: Twenty-eight patients were randomised to OMT (n=14) or CAVI (n=14). The primary endpoint was maximal oxygen uptake at the three-month follow-up. Secondary endpoints included six-minute walk test, NYHA class, NT-proBNP levels, right heart function, unscheduled heart failure hospitalisation, and quality of life as assessed by the Minnesota Living with Heart Failure Questionnaire (MLHFQ). Patients underwent follow-up examinations one, three, six, and twelve months after randomisation. Maximal oxygen uptake did not change significantly in either group after three months and there was no difference between the OMT and CAVI groups (-0.1±1.8 ml∙kg-1∙min-1 vs -1.0±1.6 ml∙kg-1∙min-1, p=0.4995). Compared to baseline, CAVI improved NYHA class, dyspnoea, and quality of life after three months. However, there were no statistically significant differences in the secondary endpoints between the groups. Four periprocedural complications occurred after CAVI, resulting in open heart surgery. Four patients in the OMT group and eight patients (including four after conversion to surgery) in the CAVI group died from right heart failure, sepsis or haemorrhage. CONCLUSIONS: CAVI did not result in a superior functional outcome compared to OMT. Due to an unexpectedly high rate of valve dislocations, the study was stopped for safety reasons.


Assuntos
Cateterismo Cardíaco/métodos , Cateterismo Venoso Central/métodos , Insuficiência Cardíaca/complicações , Implante de Prótese de Valva Cardíaca/métodos , Insuficiência da Valva Tricúspide/cirurgia , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/mortalidade , Cateterismo Venoso Central/efeitos adversos , Cateterismo Venoso Central/instrumentação , Causas de Morte , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/mortalidade , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/instrumentação , Humanos , Minnesota/epidemiologia , Desenho de Prótese , Qualidade de Vida , Índice de Gravidade de Doença , Taxa de Sobrevida , Resultado do Tratamento , Valva Tricúspide/fisiopatologia , Insuficiência da Valva Tricúspide/complicações , Insuficiência da Valva Tricúspide/epidemiologia , Veia Cava Inferior/fisiopatologia
4.
Eur Radiol ; 29(4): 1714-1723, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-30255246

RESUMO

OBJECTIVE: To analyse extracardiac findings in patients without significant coronary artery disease (CAD) in general and in symptomatic patients in particular. METHODS: We searched the Radiology Information System database for coronary computed tomography angiographies (CTA) performed from 2000-2014 and retrospectively enrolled 3,898 patients without significant CAD (coronary stenosis < 50%) in CTA. In 2,330 symptomatic patients, we analysed the spectrum of extracardiac findings and identified pathologies potentially explaining chest pain. Finally, we investigated variables affecting the number of extracardiac findings detected in CTA. RESULTS: Overall extracardiac findings were found in 1,177 patients (30.2%; 95%CI, 28.8-31.7%). 94 patients (2.4%; 95%CI, 2.0-2.9%) had extracardiac findings with a recommendation for follow-up, sixteen patients (0.4%; 95%CI, 0.3-0.7%) had incidental urgent, and another three patients (0.1%; 95%CI, 0.1-0.2%) had incidental malignant extracardiac findings. 185 of 2,330 symptomatic patients (7.9%; 95%CI, 6.9-9.1%) revealed extracardiac findings potentially explaining chest pain after exclusion of significant CAD. The number of extracardiac findings increased significantly with patient age (p < 0.001) and the cumulative experience of the CT reader (p < 0.001). CONCLUSION: 30.2% of patients undergoing CTA for exclusion of CAD had ECF, and 7.9% of symptomatic patients without significant CAD on their examination had findings that could potentially explain their symptoms. KEY POINTS: • Of patients undergoing CTA, 2.8% have relevant incidental extracardiac findings. • CTA could identify the differential diagnosis of chest pain when excluding significant CAD. • Patient age and reader's professional experience influence the number of detected ECFs.


Assuntos
Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Idoso , Dor no Peito/diagnóstico por imagem , Dor no Peito/etiologia , Diagnóstico Diferencial , Feminino , Humanos , Achados Incidentais , Masculino , Pessoa de Meia-Idade , Sistemas de Informação em Radiologia , Estudos Retrospectivos
5.
Acta Radiol ; 59(2): 161-169, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-28513211

RESUMO

Background Computed tomography (CT) of the left atrium (LA) is performed prior to pulmonary vein isolation (PVI) to improve success of circumferential ablation for atrial fibrillation. The ablation procedure itself exposes patients to substantial radiation doses, therefore radiation dose reduction in pre-ablational imaging is of concern. Purpose To assess and compare diagnostic performance of low-radiation dose preprocedural CT in patients scheduled for PVI using two types of reconstruction algorithms. Material and Methods Forty-six patients (61 ± 10 years) scheduled for PVI were enrolled in this study irrespective of body-mass-index or cardiac rhythm at examination. An electrocardiographically triggered dual-source CT scan was performed. Filtered back projection (FBP) and iterative reconstruction (IR) algorithms were applied. Images were integrated into an electroanatomic mapping (EAM) system. Subjective image quality was scored independently by two readers on a five-point scale for both reconstruction algorithms (1 = excellent to 5 = non-diagnostic). Signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and effective radiation dose were calculated. Results Data acquisition and EAM integration were successful in all patients. Median image quality score was 1 for both FBP (quartiles = 1, 1.62; range = 1-3) and IR (quartiles = 1, 1.5; range = 1-3). Mean SNR was 7.61 ± 2.14 for FBP and 9.02 ± 2.69 for IR. Mean CNR was 5.92 ± 1.80 for FBP and 6.95 ± 2.29 for IR. Mean effective radiation dose was 0.3 ± 0.1 mSv. Conclusion At a radiation dose of 0.3 ± 0.1 mSv, high-pitch dual-source CT yields LA images of consistently high quality using both FBP and IR. IR raises SNR and CNR without significantly improving subjective image quality.


Assuntos
Átrios do Coração , Veias Pulmonares/cirurgia , Tomografia Computadorizada por Raios X/métodos , Algoritmos , Fibrilação Atrial/cirurgia , Eletrocardiografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Doses de Radiação
7.
J Comput Assist Tomogr ; 39(5): 649-56, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26125297

RESUMO

OBJECTIVE: The aim of the study was to compare radiation exposure and image quality between dedicated computed tomography (CT) protocols for preoperative total hip arthroplasty (THA) planning. METHODS: Three protocols with automated tube current modulation using 64-slice (n = 177) and 128-slice CT scanners without (n = 129) and with automated tube voltage preselection (n = 84) were compared. RESULTS: All 390 CTs were of sufficient quality for THA planning. Mean DLP was 235.0 mGy*cm (effective dose 2.8 mSv). Lowest radiation exposure (2.5 mSv) was seen with automated voltage preselection and the algorithm's selection was 100 kV (90.5% of patients) and 120 kV. Lowest image noise was seen in the highest dose group (3.1 mSv, 128-slice CT fixed tube voltage). A significant difference in cortical bone radiodensity was seen between 100 kV and 120 kV (P < 0.0001). CONCLUSIONS: Preoperative pelvic CT for THA planning is possible with very low radiation dose and reliable quality. Automated voltage preselection further decreases the effective dose by 18.2%.


Assuntos
Artroplastia de Quadril , Doses de Radiação , Exposição à Radiação/estatística & dados numéricos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Imageamento Tridimensional , Masculino , Pessoa de Meia-Idade
8.
Pacing Clin Electrophysiol ; 37(10): 1291-6, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24888641

RESUMO

BACKGROUND: Postoperative lead perforation is a life-threatening complication of cardiac pacing. Identification of precipitating factors for this serious complication may help to anticipate a specific risk profile and to minimize the incidence. METHODS: We conducted a retrospective tertiary referral center analysis to clarify clinical, anatomical, and technical characteristics related to pacemaker (PM) and cardioverter/defibrillator lead perforation. We examined the baseline characteristics and the symptoms. In a subgroup, we investigated the myocardial thickness on contrast-enhanced cardiac computed tomography. RESULTS: We enrolled 26 patients. Female gender appears to put patients at slightly increased risk for lead perforation. In a majority active fixation leads were used. Symptoms occurred in 72%. Pericardial effusion and tamponade were present in 38% and 19%, respectively. Sensing was compromised in 65%. A high pacing threshold or exit block occurred in 92%. Myocardial thickness did not differ between patients with or without perforation. In 96%, the perforation was treated by transvenous withdrawal. CONCLUSION: Chest pain, phrenic stimulation, bad sensing, or exit block early after PM implantation must prompt radiological and echocardiographic evaluation. A missing pericardial effusion particularly late after implantation does not rule out a perforation. Especially active fixating leads have a higher risk of perforation. With cardiac surgery in standby transvenous withdrawal is a safe way to treat lead perforation.


Assuntos
Desfibriladores Implantáveis/efeitos adversos , Traumatismos Cardíacos/etiologia , Coração/anatomia & histologia , Marca-Passo Artificial/efeitos adversos , Complicações Pós-Operatórias/etiologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Derrame Pericárdico , Estudos Retrospectivos , Fatores de Risco
9.
Eur Radiol ; 24(1): 120-7, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23949727

RESUMO

OBJECTIVES: To assess the effect of lower volumes of contrast medium (CM) on image quality in high-pitch dual-source computed tomography coronary angiography (CTCA). METHODS: One-hundred consecutive patients (body weight 65-85 kg, stable heart rate ≤65 bpm, cardiac index ≥2.5 L/min/m(2)) referred for CTCA were prospectively enrolled. Patients were randomly assigned to one of five groups of different CM volumes (G30, 30 mL; G40, 40 mL; G50, 50 mL; G60, 60 mL; G70, 70 mL; flow rate 5 mL/s each, iodine content 370 mg/mL). Attenuation within the proximal and distal coronary artery segments was analysed. RESULTS: Mean attenuation for men and women ranged from 345.0 and 399.1 HU in G30 to 478.2 and 571.8 HU in G70. Mean attenuation values were higher in groups with higher CM volumes (P < 0.0001) and higher in women than in men (P < 0.0001). The proportions of segments with attenuation of at least 300 HU in G30, G40, G50, G60 and G70 were 89 %, 95 %, 98 %, 98 % and 99 %. CM volume of 30 mL in women and 40 mL in men proved to be sufficient to guarantee attenuation of at least 300 HU. CONCLUSIONS: In selected patients high-pitch dual-source CTCA can be performed with CM volumes of 40 mL in men or 30 mL in women. KEY POINTS: • High-pitch dual-source coronary angiography is feasible with low contrast media volumes. • Traditional injection rules still apply: higher volumes result in higher enhancement. • The patient's gender is a co-factor determining the level of contrast enhancement. • Volumes can be reduced down to 30-40 mL in selected patients.


Assuntos
Técnicas de Imagem de Sincronização Cardíaca/métodos , Meios de Contraste/administração & dosagem , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico , Tomografia Computadorizada Multidetectores/métodos , Relação Dose-Resposta a Droga , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
10.
Emerg Med Int ; 2013: 984645, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-24381762

RESUMO

Objective. This study aims to assess the impact of adaptive statistical iterative reconstruction (ASIR) on CT imaging quality, diagnostic interpretability, and radiation dose reduction for a proven CT acquisition protocol for total body trauma. Methods. 18 patients with multiple trauma (ISS ≥ 16) were examined either with a routine protocol (n = 6), 30% (n = 6), or 40% (n = 6) of iterative reconstruction (IR) modification in the raw data domain of the routine protocol (140 kV, collimation: 40, noise index: 15). Study groups were matched by scan range and maximal abdominal diameter. Image noise was quantitatively measured. Image contrast, image noise, and overall interpretability were evaluated by two experienced and blinded readers. The amount of radiation dose reductions was evaluated. Results. No statistically significant differences between routine and IR protocols regarding image noise, contrast, and interpretability were present. Mean effective dose for the routine protocol was 25.3 ± 2.9 mSv, 19.7 ± 5.8 mSv for the IR 30, and 17.5 ± 4.2 mSv for the IR 40 protocol, that is, 22.1% effective dose reduction for IR 30 (P = 0.093) and 30.8% effective dose reduction for IR 40 (P = 0.0203). Conclusions. IR does not reduce study interpretability in total body trauma protocols while providing a significant reduction in effective radiation dose.

11.
J Heart Valve Dis ; 22(5): 751-3, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-24383393

RESUMO

Repeat aortic valve replacement (AVR) after freestanding homograft root replacement with reimplantation of the coronary arteries is challenging and risky, especially in patients with major homograft wall calcifications. Although new transcatheter techniques for AVR may offer an alternative in structurally degenerated homografts, they are not suitable to treat endocarditis. Here, the case is reported of successful treatment of bacterial endocarditis within a totally calcified homograft after aortic root replacement by combining conventional surgery and transcatheter techniques.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/patologia , Valva Aórtica/cirurgia , Calcinose/cirurgia , Cateterismo Cardíaco/métodos , Endocardite/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Infecções Relacionadas à Prótese/cirurgia , Idoso , Aloenxertos , Estenose da Valva Aórtica/complicações , Calcinose/complicações , Endocardite/complicações , Feminino , Humanos
12.
Ann Thorac Surg ; 92(4): 1308-14, 2011 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21958777

RESUMO

BACKGROUND: This study was performed to collect prospective safety and effectiveness data from a tissue-engineered heart valve implanted for reconstruction of the right ventricular outflow tract during the Ross operation. METHODS: From May 2000 until June 2002, 11 consecutive patients, mean age 39.6 ± 10.3 years, received a tissue-engineered heart valve (additive and logistic European System for Cardiac Operative Risk Evaluation, respectively, 3.3 ± 1.3 and 2.8% ± 1.4%). Two to four weeks prior to the Ross operation a piece of forearm vein or saphenous vein was harvested to isolate, characterize, and expand endothelial cells. A cryopreserved pulmonary allograft was decellularized, coated, and seeded with autologous vascular endothelial cells, using a specially developed bioreactor. Cell seeding density was 1.1 × 10(5) ± 0.5 × 10(5) cells/cm(2) with a viability of 93.2% ± 2.1%. RESULTS: All patients survived surgery. Postoperatively no fever of unknown origin was evident. Currently all patients are in New York Heart Association class I. Evaluation of the tissue-engineered heart valve by transthoracic echocardiography showed a mean pressure gradient of 5.4 ± 2.0 mm Hg at 10 years. Multislice computed tomography showed no calcification up to 10 years. CONCLUSIONS: Tissue-engineered heart valves showed excellent hemodynamic performance and may prevent degeneration during long-term follow-up.


Assuntos
Endotélio Vascular/citologia , Doenças das Valvas Cardíacas/cirurgia , Valva Pulmonar/transplante , Engenharia Tecidual/métodos , Adulto , Bioprótese , Contagem de Células , Células Cultivadas , Criopreservação/métodos , Células Endoteliais/citologia , Células Endoteliais/transplante , Endotélio Vascular/transplante , Feminino , Seguimentos , Sobrevivência de Enxerto , Humanos , Masculino , Desenho de Prótese , Estudos Retrospectivos , Fatores de Tempo , Transplante Homólogo , Resultado do Tratamento
13.
Eur Radiol ; 21(7): 1416-23, 2011 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-21347640

RESUMO

OBJECTIVES: To investigate image quality of triple-rule-out (TRO) computed tomography (CT) using a 320-row-detector CT system with substantially reduced contrast medium volume at 100 kV. METHODS: Forty-six consecutive patients with noncritical, acute chest pain underwent 320-row-detector CT using a two-step TRO protocol consisting of a non-spiral, non-gated chest CT acquisition (150 mA) followed by a non-spiral, electrocardiography-gated cardiac acquisition (200-500 mA based on body mass index (BMI)). Data were acquired using a biphasic injection protocol with a total iodinated contrast medium volume of 60 ml (370 mg/ml). Vessel attenuation and effective doses were recorded. Image quality was scored independently by two readers. RESULTS: Mean attenuation was 584 ± 114 Hounsfield units (HU) in the ascending aorta, 335 ± 63HU in the aortic arch, 658 ± 136HU in the pulmonary trunk, and 521 ± 97HU and 549 ± 102HU in the right and left coronary artery, respectively. In all but one patient, attenuation and image quality allowed accurate visualization of the pulmonary arteries, thoracic aorta, and coronary arteries in a single examination. Ninety-six percent of all coronary artery segments were rated diagnostic. Radiation exposure ranged between 2.0 and 3.3 mSv. CONCLUSION: Using 320-row-detector CT the investigated low-dose TRO protocol resulted in excellent opacification and image quality with substantial reduction of contrast medium volume compared to recently published TRO protocols.


Assuntos
Dor no Peito/diagnóstico por imagem , Doses de Radiação , Tomografia Computadorizada por Raios X/métodos , Índice de Massa Corporal , Meios de Contraste/administração & dosagem , Eletrocardiografia , Feminino , Humanos , Imageamento Tridimensional , Iohexol/administração & dosagem , Iohexol/análogos & derivados , Masculino , Pessoa de Meia-Idade , Interpretação de Imagem Radiográfica Assistida por Computador
15.
Europace ; 12(8): 1090-7, 2010 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-20525729

RESUMO

AIMS: To compare non-gated vs. electrocardiogram (ECG)-gated 64-detector-row computed tomography (MDCT) of the left atrium (LA) for integrated electroanatomic mapping (EAM) in patients with paroxysmal atrial fibrillation (AF). METHODS AND RESULTS: Twenty-nine consecutive patients with paroxysmal AF underwent MDCT prior to pulmonary vein isolation (PVI). All patients were in sinus rhythm both during CT imaging and PVI. Multi-detector-row computed tomography was performed in 15 patients without ECG-gating (non-gated MDCT) and in 14 patients with retrospective ECG-gating (ECG-gated MDCT). Image quality of LA reconstructions from MDCT was rated on a five-point scale (from 1 = excellent to 5 = segmentation failed). Registration error between LA geometry obtained from EAM and MDCT was calculated as the mean distance between EAM points and MDCT surface. In all patients, LA was successfully segmented from MDCT data. The segmentation process took 2:31 +/- 0:54 min for non-gated MDCT and 2:36 +/- 0:47 min for ECG-gated MDCT (P = 0.8). Image quality scores of LA reconstructions from non-gated and ECG-gated MDCT were 1.3 +/- 0.6 and 1.4 +/- 0.7, respectively (P = 0.76). There was no significant difference in the registration error between non-gated and ECG-gated MDCT (1.8 +/- 0.2 vs. 1.9 +/- 0.3 mm, respectively; P = 0.6). The radiation dose of non-gated MDCT was significantly lower compared with ECG-gated MDCT (4.6 +/- 1.4 vs. 13.4 +/- 3.6 mSv, respectively; P < 0.001). CONCLUSION: Non-gated MDCT depicts LA with appropriate image quality for integrated EAM, while exposing patients to substantially lower radiation dose compared with ECG-gated MDCT.


Assuntos
Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Ablação por Cateter , Veias Pulmonares/cirurgia , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Angiografia Coronária/métodos , Eletrocardiografia , Feminino , Humanos , Imageamento Tridimensional/métodos , Masculino , Pessoa de Meia-Idade , Veias Pulmonares/diagnóstico por imagem , Doses de Radiação , Estudos Retrospectivos
16.
Int J Cardiovasc Imaging ; 26(8): 933-40, 2010 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-20422293

RESUMO

To compare tube current adaptation based on 3 body mass index (BMI) categories versus anterior-posterior chest diameter (APD) for radiation dose optimisation in patients undergoing dynamic volume cardiac CT. Two cardiac imaging centres participated in the study. 20 patients underwent a prospectively triggered 320-slice single beat cardiac CT using the X-ray tube current [mA] manually adjusted to the patient's BMI (group I). In 20 subsequent patients, the tube current was adapted according to the patient's APD (group II). All other parameters were kept constant. Image noise was defined as the standard deviation of attenuation values and measured using a ROI in the descending aorta. Variation in image noise was statistically compared between both patient groups. Average and standard deviation of pixel noise were 29.1 HU and 14.8 HU in group I and 28.0 HU and 4.2 HU in group II. Inter-individual variation of pixel noise was significantly lower in group II compared to group I (p < 0.0001). Tube current adaptation based on APD is superior to stepwise adaptation based on BMI for optimising radiation dose in dynamic volume cardiac CT and therefore limits unnecessary radiation dose while ensuring diagnostic image quality in patients with diverse body habitus.


Assuntos
Índice de Massa Corporal , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Coração/diagnóstico por imagem , Doses de Radiação , Tórax/anatomia & histologia , Tomografia Computadorizada por Raios X , Artefatos , Feminino , Alemanha , Humanos , Masculino , Pessoa de Meia-Idade , Ontário , Valor Preditivo dos Testes , Estudos Prospectivos , Reprodutibilidade dos Testes
17.
J Digit Imaging ; 23(1): 8-17, 2010 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-18773240

RESUMO

The study investigates the effect of a substantial dose reduction on the variability of lung nodule volume measurements by assessing and comparing nodule volumes using a dedicated semiautomated segmentation software on ultralow-dose computed tomography (ULD-CT) and standard-dose computed tomography (SD-CT) data. In 20 patients, thin-slice chest CT datasets (1 mm slice thickness; 20% reconstruction overlap) were acquired at ultralow-dose (120 kV, 5 mAs) and at standard-dose (120 kV, 75 mAs), respectively, and analyzed using the segmentation software OncoTREAT (MeVis, Bremen, Germany; version 1.3). Interobserver variability of volume measurements of 202 solid pulmonary nodules (mean diameter 11 mm, range 3.2-44.5 mm) was calculated for SD-CT and ULD-CT. With respect to interobserver variability, the 95% confidence interval for the relative differences in nodule volume in the intrascan analysis was measured with -9.7% to 8.3% (mean difference -0.7%) for SD-CT and with -12.6% to 12.4% (mean difference -0.2%) for ULD-CT. In the interscan analysis, the 95% confidence intervals for the differences in nodule volume ranged with -25.1% to -23.4% and 26.2% to 28.9% (mean difference 1.4% to 2.1%) dependent on the combination of readers and scans. Intrascan interobserver variability of volume measurements was comparable for ULD-CT and SD-CT data. The calculated variability of volume measurements in the interscan analysis was similar to the data reported in the literature for CT data acquired with equal radiation dose. Thus, the evaluated segmentation software provides nodule volumetry that appears to be independent of the dose level with which the CT source dataset is acquired.


Assuntos
Neoplasias Pulmonares/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Software , Nódulo Pulmonar Solitário/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Algoritmos , Automação , Intervalos de Confiança , Feminino , Humanos , Masculino , Variações Dependentes do Observador , Doses de Radiação , Estudos Retrospectivos
18.
Curr Opin Investig Drugs ; 10(9): 947-54, 2009 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-19705337

RESUMO

Cardiac CT scanning, such as coronary artery calcium (CAC) scoring and multislice CT angiography (CTA), allows the direct visualization of coronary atherosclerosis. CT is a non-invasive test that provides information on stenosis severity and composition, as well as the cumulative burden of coronary plaques. The detection of subclinical coronary plaques is increasingly recognized as an important estimator of risk, with high, independent correlation to future adverse cardiac events. Both CAC scoring and CTA can be used clinically for cardiovascular risk assessment and the investigation of chest-pain syndromes. For either of these indications, CT is most effective when applied to the majority of cardiac patients with intermediate cardiovascular risk. The effectiveness of CT is based on the likelihood that CAC scoring and CTA will modify clinical decision-making in patients with different pre-test risk categories, and on the ability of CT to identify patients with hemodynamically relevant stenoses, as well as patients at high risk for future hard cardiovascular events (eg, cardiac death and non-fatal acute myocardial infarction).


Assuntos
Calcinose/diagnóstico , Angiografia Coronária/métodos , Doença das Coronárias/diagnóstico , Vasos Coronários/química , Tomografia Computadorizada por Raios X/métodos , Doença das Coronárias/diagnóstico por imagem , Vasos Coronários/patologia , Humanos , Fatores de Risco
19.
Tex Heart Inst J ; 36(3): 238-40, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-19568395

RESUMO

Coronary artery aneurysms are clinically relevant, because thromboembolism, rupture, and hemodynamic problems related to compression may occur. Surgical management is not standardized, and an individual approach toward each aneurysm is prudent. Giant coronary artery aneurysms (larger than 20 mm in diameter) originate in different ways and are extremely rare, and their surgical treatment is also not well defined.Herein, we report the case of a 63-year-old man who had 2 aneurysms of the circumflex coronary artery and a 65-mm aneurysm of the right coronary artery. The diagnosis was established by use of transesophageal echocardiography, magnetic resonance imaging, and coronary angiography. An intraoperatively discovered smaller aneurysm of the right coronary artery was ligated. The giant thrombus-filled aneurysm of the right coronary artery was partially resected, because it compressed the right atrium and ventricle. A graft of the greater saphenous vein was constructed to the distal right coronary artery. The smaller, noncompressing aneurysms in the circumflex coronary artery were excluded by means of proximal and distal suture ligation, and bypass grafting was performed with use of skeletonized left internal mammary artery. The procedures were successful. We discuss the reasons behind our individual approach toward our patient's aneurysms.


Assuntos
Aneurisma Coronário/cirurgia , Ponte de Artéria Coronária , Veia Safena/transplante , Trombectomia , Aneurisma Coronário/complicações , Aneurisma Coronário/diagnóstico , Angiografia Coronária , Trombose Coronária/etiologia , Trombose Coronária/cirurgia , Ecocardiografia Transesofagiana , Humanos , Ligadura , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Técnicas de Sutura , Resultado do Tratamento
20.
Ann Thorac Surg ; 87(6): 1920-3, 2009 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-19463622

RESUMO

Bronchogenic cysts are congenital lesions that are a remnant from abnormal budding of the embryonic foregut. These cysts are usually single; most cases are either asymptomatic or present with respiratory symptoms. A 43-year-old woman presented with intermittent type II atrioventricular block during cholecystectomy. The cardiac evaluation including transthoracic and transesophageal echocardiography and magnetic resonance imaging revealed a cystic homogeneous mass within the interatrial septum. The patient underwent surgical resection of the mass and closure of the septal defect. Histopathology identified ciliated columnar epithelium, consistent with the diagnosis of a bronchogenic cyst.


Assuntos
Septo Interatrial , Bloqueio Atrioventricular/diagnóstico , Bloqueio Atrioventricular/etiologia , Cisto Broncogênico/complicações , Adulto , Feminino , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA