Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 42
Filtrar
1.
Arch Orthop Trauma Surg ; 144(8): 3517-3522, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-39085439

RESUMO

INTRODUCTION: Over the last decades, arthroscopic surgery has become increasingly relevant as its minimally invasive approach offers many benefits. To investigate the risks of orthoscopic surgery at the elbow, this study aimed to investigate the development of temperatures in elbow joints while performing radiofrequency ablation in arthroscopic surgery. MATERIALS AND METHODS: We performed standard arthroscopic surgeries with posterolateral, transtricipital and anterolateral approaches on seven cadaveric elbows and performed ablation on predefined locations with or without irrigation. Two temperature probes were positioned into the olecranon fossa and between the ulnar nerve and the medial joint capsule. The temperature data were recorded using a real-time data logger. A bipolar radiofrequency ablation (bRFA) device was used at the medial and lateral recess and in the fossa olecrani over a defined period. Data was then analyzed using Matlab. RESULTS: Using bRFA without irrigation results in rapidly increasing temperature within the joint. A significant temperature increase was found within only 5 s without irrigation (p = 0.0052) in the fossa olecrani. We did not observe critical temperatures above 41 °C close to the ulnar nerve within 30 s under constant irrigation (p = 0.0747). CONCLUSIONS: Radiofrequency ablation (RFA) can be safely used in elbow arthroscopy with irrigation. The continuous use without irrigation should be limited to 3 s. Despite the anatomical proximity of the ulnar nerve and capsule, we were able to show that a possible rise in temperature most likely does not affect the ulnar nerve.


Assuntos
Artroscopia , Articulação do Cotovelo , Ablação por Radiofrequência , Artroscopia/métodos , Humanos , Ablação por Radiofrequência/métodos , Articulação do Cotovelo/cirurgia , Cadáver , Irrigação Terapêutica/métodos , Ablação por Cateter/métodos
2.
Artigo em Inglês | MEDLINE | ID: mdl-39032687

RESUMO

HYPOTHESIS AND/OR BACKGROUND: Extensive, irreparable rotator cuff tears remain a surgical challenge and multiple treatment options are proposed and currently in use. To biomechanically compare superior glenohumeral translation, subacromial contact pressures, and area in a box-shaped reconstruction using the long head of the biceps tendon (LHBT) in an irreparable supraspinatus tendon tear model. METHODS: Seven cadaveric shoulders (mean age 61 years; range 32-84 years; standard deviation 22.3) were tested with a custom testing rig used to evaluate superior translation; subacromial contact pressures; and areas at 0°, 30°, and 60° of glenohumeral abduction. Conditions tested included the native state; a complete tear of the supraspinatus tendon; a wide box-shaped, double-bundle LHBT superior capsular reconstruction (BS-SCR); and a narrow BS-SCR. RESULTS: Compared with the wide BS-SCR, the narrow BS-SCR had statistically significantly lower median contact pressure at 30° and 60°. The subacromial contact area showed a statistically significant difference at 0° (P = .001) and 30° (P = .004) for the narrow BS-SCR compared with the wide BS-SCR. At an abduction angle of 0°, the narrow BS-SCR could restore superior translation significantly better compared with the wide construct. For all angles, the wide and narrow BS-SCR increased the median subacromial distance statistically significantly. The contact areas in 30° and 60° of abduction were higher for all scenarios, both peaking in the intact state in 30° with approximately 600 mm2. CONCLUSIONS: In comparison to a wide BS-SCR, a narrow BS-SCR using the LHBT has biomechanical advantages in regard to subacromial contact pressures, the subacromial contact areas, as well as the acromiohumeral distance. The width of the reconstruction, therefore, has a direct influence on the success of the technique.

3.
Artigo em Inglês | MEDLINE | ID: mdl-39067663

RESUMO

BACKGROUND: Pneumatic tourniquets are frequently employed in extremity surgeries, aiming to enhance intraoperative visibility and minimize blood loss. Although their benefits and drawbacks have been extensively studied in lower limb operations, their impact on upper limb procedures, particularly elbow surgery, remains poorly understood. This study investigates the advantages and risks associated with pneumatic tourniquet used in elbow surgery. METHODS: A retrospective analysis was conducted on 183 patients who underwent elbow surgery for fractures between January 2019 and September 2023. Patients were categorized into 2 groups: those who underwent surgery with a tourniquet (WT) and those without a tourniquet (NT). Subgroup analyses were performed based on fracture complexity. Data collected included patient characteristics, tourniquet usage, surgical duration, pre- and postoperative hemoglobin levels, C-reactive protein levels, pain assessments, opioid administration, hospital stay duration, follow-up, complications, and revisions. Statistical analyses were used to identify significant differences and correlations. RESULTS: The use of a tourniquet in elbow surgery yielded several notable outcomes. Patients in the WT group experienced significantly shorter surgical durations and hospital stays. Hemoglobin drop was lower in the WT group, indicating reduced blood loss. However, there were no significant differences in postoperative pain, opioid consumption, or complications between the WT and NT groups. Subgroup analysis revealed that the recorded differences, particularly shorter surgical durations, were more pronounced in complex fractures. CONCLUSIONS: This study shows promising results in the use of pneumatic tourniquets in elbow surgery in terms of enhanced efficiency, reduced blood loss, and overall safety, without compromising patient outcomes. However, the potential influence of perioperative decision-making on tourniquet usage underscores the need for further research to elucidate its role and optimize its application, especially in complex elbow fractures.

4.
Oper Orthop Traumatol ; 36(3-4): 180-187, 2024 Aug.
Artigo em Alemão | MEDLINE | ID: mdl-39078520

RESUMO

OBJECTIVE: Restoration of longitudinal forearm stability by reconstruction of the central band (CB) of the interosseous membrane (IOM) of the forearm. INDICATIONS: Acute and chronic Essex-Lopresti lesions (EL) with longitudinal forearm instability. CONTRAINDICATIONS: Absolute: acute/subacute infection. Relative: severe complex regional pain syndrome (CRPS), bony deformity/bone loss, pronounced osteoarthritis of the elbow and wrist. SURGICAL TECHNIQUE: Ulnar approach with exposure of the ulna approximately 6 cm proximal to the ulnar styloid. Creation of a 3.5 mm drill hole from ulnar-distal to radial-proximal. A Fiberloop (Fa. Arthrex, Naples, FL, USA) is fixed to one end of the LARS (Ligament Advanced Reconstruction System, Fa. Corin Group, Cirencester, UK) in a whipstitch technique, is shuttled through the drill hole from radial to ulnar and fixed over a BicepsButton (Fa. Arthrex, Naples, FL, USA). Exposure of the radius through a modified Henry approach. A 3.5 mm drill hole is made from radial-proximal to ulnar-distal approximately 12 cm proximal to the radial styloid. The graft is shuttled from the ulnar to the radial incision directly on the palmar surface of the IOM and shortened to the required length. Another Fiberloop is used to perform a whipstitch on the free end of the LARS. The final fixation of the CB reconstruction is achieved by shuttling the Fiberloop sutures through the radial drill hole with fixation over a BicepsButton. POSTOPERATIVE MANAGEMENT: Short-term immobilization in a long arm cast with subsequent early functional treatment. RESULTS: Mediocre to poor clinical results are reported in the literature for the treatment of chronic EL. Future research will tell whether the advanced surgical techniques with CB reconstruction will lead to better clinical outcomes.


Assuntos
Instabilidade Articular , Procedimentos de Cirurgia Plástica , Humanos , Procedimentos de Cirurgia Plástica/métodos , Resultado do Tratamento , Instabilidade Articular/cirurgia , Masculino , Feminino , Traumatismos do Antebraço/cirurgia , Adulto
5.
Oper Orthop Traumatol ; 36(3-4): 188-197, 2024 Aug.
Artigo em Alemão | MEDLINE | ID: mdl-39078519

RESUMO

OBJECTIVE: The goal of minced cartilage implantation (MCI) is to restore an intact cartilage surface in focal osteochondral lesions of the humeral capitellum. INDICATIONS: The indications for MCI are limited osteochondral lesions at the humeral capitellum, also at the head of the radius, with intact cartilage border as well as in situ or a completely detached fragment, and free joint bodies (grade II-grade V according to Hefti). CONTRAINDICATIONS: Contraindications for MCI are already concomitant or associated cartilage damage as well as bilateral osteochondral lesions and insufficient available cartilage material. SURGICAL TECHNIQUE: After diagnostic arthroscopy to detect possible concomitant pathologies and to exclude already corresponding cartilage lesions, the arthroscope is flipped posterolaterally over the high posterolateral portal and a second portal is created under visualization via the soft spot. Initially, debridement of the focal cartilage defect, assessment of the marginal zone, and/or salvage of free joint bodies. Using a smooth shaver and the filter provided, the partially or even completely detached cartilage fragment is unidirectionally fragmented under continuous suction. The remaining defect with a stable marginal zone is cleanly curetted, and the joint is completely dried. The fragmented cartilage collected in the filter is bonded to a membrane using autologous conditioned plasma (ACP) and then arthroscopically applied to the defect via a cannula, sealed using thrombin and fibrin. POSTOPERATIVE MANAGEMENT: Postoperative immobilization in a cast for at least 24 h is required. Afterwards, free exercise of the joint is possible, but no loading should be maintained for 6 weeks. Return to sport after 3 months. RESULTS: Good to very good clinical and MRI morphologic results are already evident in the short-term course. Prospective and retrospective multicenter studies are needed to evaluate future long-term results.


Assuntos
Cartilagem Articular , Humanos , Resultado do Tratamento , Masculino , Cartilagem Articular/cirurgia , Cartilagem Articular/diagnóstico por imagem , Feminino , Adulto , Artroscopia/métodos , Articulação do Cotovelo/cirurgia , Articulação do Cotovelo/diagnóstico por imagem , Lesões no Cotovelo , Úmero/cirurgia , Úmero/diagnóstico por imagem , Pessoa de Meia-Idade
6.
Int Orthop ; 48(9): 2421-2427, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-39031202

RESUMO

PURPOSE: Searching for quick determinable biomarkers with high sensitivity and specificity is necessary to improve and optimise the early diagnosis of periprosthetic elbow infection (PEI). Therefore, this study's objective was to evaluate the diagnostic value of synovial fluid interleukin-6 (IL-6) levels for diagnosing PEI in total elbow arthroplasty. METHOD: Twelve prospective enrolled patients underwent total elbow arthroplasty revision surgery, during which synovial fluid was obtained. Between the initial implantation and the revision procedure were 33.5 ± 41 months (range, 2-144 months). Synovial fluid was collected for immediate IL-6 analysis parallel to the revision surgery. Furthermore, microbiological samples were obtained and analysed. Two groups were defined based on the microbiological results: non-infection and infection group. The ability of synovial fluid IL-6 analysis to predict infection status was explored using receiver operating characteristic curves and further statistical analysis. RESULTS: Synovial fluid IL-6 analysis had a good diagnostic accuracy of 83% for PEI with an area under the curve of 0,79 and an ideal cutoff value (determined using Youden's criterion) of 15244 pg/mL. DISCUSSION: This is the first study to clinically evaluate IL-6 as a diagnostical marker for periprosthetic joint infection (PJI) in total elbow arthroplasty. Our results suggest a good accuracy and high sensitivity for IL-6 to identify a PEI. The analysis of IL-6 can improve surgical decision-making regarding managing total elbow arthroplasty in terms of one- or two-staged revision. CONCLUSION: IL-6 can play an important role in the perioperative differentiation of infected and non-infected situations.


Assuntos
Biomarcadores , Articulação do Cotovelo , Interleucina-6 , Infecções Relacionadas à Prótese , Líquido Sinovial , Humanos , Líquido Sinovial/metabolismo , Infecções Relacionadas à Prótese/diagnóstico , Interleucina-6/análise , Interleucina-6/metabolismo , Masculino , Feminino , Idoso , Pessoa de Meia-Idade , Estudos Prospectivos , Biomarcadores/análise , Biomarcadores/metabolismo , Articulação do Cotovelo/cirurgia , Artroplastia de Substituição do Cotovelo/efeitos adversos , Artroplastia de Substituição do Cotovelo/métodos , Reoperação , Sensibilidade e Especificidade , Idoso de 80 Anos ou mais , Curva ROC
7.
Artigo em Inglês | MEDLINE | ID: mdl-38942223

RESUMO

BACKGROUND: Coronal shear fractures of the capitellum are rare injuries which can be challenging to treat. The aim of this study was to compare the biomechanical properties of different internal screw fixation techniques for Dubberley type IA fractures of the capitellum. METHODS: In this biomechanical study, Dubberley type IA fractures of the capitellum were created in 30 human fresh-frozen humeri. The specimens were then divided into 3 groups: fixation was either performed with 3 × 3.0 mm headless cannulated compression screws (HCCSs) in anteroposterior (AP) orientation (AP group), 3 × 3.0 mm HCCSs in posteroanterior (PA) orientation (PA group) or with 2 × 3.0 mm HCCSs in PA orientation and 1 × 3.0 mm HCCS in lateral orientation (LAT) group. Displacement under cyclic loading and ultimate load-to-failure were evaluated in all specimens. RESULTS: There was no significant difference in fragment displacement after 2000 cycles between AP and PA groups (0.8 ± 0.5 mm vs. 0.8 ± 0.6 mm; P = .987) or PA and LAT groups (0.8 ± 0.6 mm vs. 0.8 ± 0.3 mm; P = .966). LAT group showed the highest load-to-failure (548 ± 250 N) without reaching statistically significant difference to AP group (388 ± 173 N; P = .101). There was also no significant difference between AP and PA groups (388 ± 173 N vs. 422 ± 114 N; P = .649). CONCLUSIONS: Variations in screw placement had no statistically significant influence on cyclic displacement or load-to-failure in Dubberley Type IA fractures. However, fracture fixation in 2 planes-both the coronal and the sagittal plane-by adding a screw in a lateral to medial direction may be beneficial to increase primary stability.

8.
Foot Ankle Spec ; : 19386400241250154, 2024 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-38726657

RESUMO

INTRODUCTION: The Bartonícek/Rammelt classification is established for posterior malleolar fractures. It subdivides the fractures into 5 types and outlines treatment recommendations. This study aims to determine the intraobserver and interobserver reliability of the Bartonícek/Rammelt classification and investigates its applicability regarding treatment recommendations. MATERIALS AND METHODS: Computed tomography (CT) scans of 80 ankle fractures with a posterior malleolar fracture were analyzed by four observers at two different time points 30 days apart (d1 and d2). Intrarater and interrater reliability was measured using kappa values. The corresponding surgery rates of the fracture subtypes were analyzed, and the surgery rates were correlated with fragment sizes and displacements. RESULTS: A moderate interobserver reliability for d1 0.41 (CI 0.35-0.47) and d2 0.42 (CI 0.36-0.48) was detected. Intraobserver reliability was documented as perfect, with a mean kappa of 0.83. Type II fractures were operated on in 50% of cases. In 50% of type II cases, a nonoperative treatment was chosen. Fragment size correlated strongly with the chosen therapy, and osteosynthesis was performed significantly more often when the fragment size exceeded 3 cm3 (P < .01). CONCLUSIONS: The Bartonícek/Rammelt classification system showed moderate interobserver reliability and perfect to substantial intraobserver reliability. In clinical practice of this study cohort, the size of the posterior malleolar fragment rather than the dislocation and joint impaction seemed to have the decision to operate on type II or III fractures. Existing treatment recommendations based on the Bartonícek/Rammelt classification correspond to the therapy algorithm carried out in this cohort of patients.Levels of Evidence: Level III: Retrospective study.

9.
Arch Orthop Trauma Surg ; 143(10): 6243-6249, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37421514

RESUMO

PURPOSE: Postoperative soft tissue swelling is a significant factor influencing outcomes after elbow surgery. It can crucially affect important parameters such as postoperative mobilization, pain, and subsequently the range of motion (ROM) of the affected limb. Furthermore, lymphedema is considered a significant risk factor for numerous postoperative complications. Manual lymphatic drainage is nowadays part of the standardized post-treatment concept, basing on the concept of activating the lymphatic tissue to absorb stagnated fluid from the tissue into the lymphatic system. This prospective study aims to investigate the influence of technical device-assisted negative pressure therapy (NP) on early functional outcomes after elbow surgery. NP was therefore compared to manual lymphatic drainage (MLD). Is a technical device-based NP suitable for treatment of lymphedema after elbow surgery? METHODS: A total of 50 consecutive patients undergoing elbow surgery were enrolled. The patients were randomized into 2 groups. 25 participants per group were either treated by conventional MLD or NP. The primary outcome parameter was defined as the circumference of the affected limb in cm postoperative up to seven days postoperatively. The secondary outcome parameter was a subjective perception of pain (measured via visual analogue scale, VAS). All parameters were measured on each day of postoperative inpatient care. RESULTS AND CONCLUSION: NP showed an overall equivalent influence compared to MLD in reducing upper limb swelling after surgery. Moreover, the application of NP showed a significant decrease in overall pain perception compared to manual lymphatic drainage on days 2, 4 and 5 after surgery (p < 0.05). CONCLUSION: Our findings show that NP could be a useful supplementary device in clinical routine treating postoperative swelling after elbow surgery. Its application is easy, effective and comfortable for the patient. Especially due to the shortage of healthcare workers and physical therapists, there is a need for supportive measures which NP could be.


Assuntos
Linfedema , Drenagem Linfática Manual , Humanos , Drenagem Linfática Manual/efeitos adversos , Estudos Prospectivos , Cotovelo , Edema/etiologia , Edema/terapia , Linfedema/complicações , Dor , Resultado do Tratamento
10.
Eur J Orthop Surg Traumatol ; 33(8): 3643-3648, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37268872

RESUMO

PURPOSE: After major COVID-19 lockdown measures were suspended in 2021, E-scooter mobility regrew rapidly. In the meantime, multiple studies were published on the potential risks for e-scooter drivers and the necessity for wearing protective equipment. But did the drivers learn their lessons? METHODS: We observed data of E-scooter-related accidents admitted to the emergency department of a level 1 German trauma center in the year 2021 and compared the data with our previous report (July 2019-July 2020). RESULTS: N = 97 E-scooter-related accidents were included, marking a 50% increase when compared to the previous observation. Most patients were young adults (28.18 ± 1.13 years) with a notable shift towards a male population (25 vs. 63, p = 0.007). While the injury pattern remained unchanged, injury severity, reflected by a significant increase in shock room treatments (p = 0.005), hospital admissions (p = 0.45), and ICU admissions (p = 0.028), increased. Lastly, we report a higher injury severity of patients driving under the influence of alcohol, expressed by significant differences in hospital admissions, shock room treatments, ICU admissions, intracerebral bleeding (p < 0.0001), and injuries requiring surgery (p = 0.0017). CONCLUSION: The increase in injury severity and especially the substantial number of accidents due to driving under the influence of alcohol, are alarming for both trauma- and neurosurgeons. As the controversy surrounding the general use of E-scooters will continue, we urge representatives to intensify their efforts regarding prevention campaigns focusing on the potential dangers of E-scooters, especially when driving under the influence of alcohol.


Assuntos
Acidentes , Centros de Traumatologia , Adulto Jovem , Humanos , Masculino , Seguimentos , Estudos Retrospectivos , Serviço Hospitalar de Emergência , Acidentes de Trânsito/prevenção & controle
11.
Arch Orthop Trauma Surg ; 143(10): 6201-6208, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37341804

RESUMO

INTRODUCTION: The SARS-CoV-2 pandemic and its associated lockdowns had a profound effect on orthopedic trauma emergencies. This study aimed to investigate the patient volume and injury patterns at a level-one trauma center during the SARS-CoV-2 pandemic and compare them to the pre-pandemic conditions. MATERIALS AND METHODS: A retrospective chart review of all patients who presented to the orthopedic trauma emergency department of a level-one trauma center in Cologne, Germany within a 2 year period from March 16th, 2019 to March 15th, 2020 (pre-pandemic control) and from March 16th, 2020 and March 15th, 2021 (pandemic) was performed. The pandemic year was separated into three periods: (1) first lockdown, (2) between lockdowns and (3) second lockdown. The absolute numbers of patient presentations, the Manchester triage score (MTS) and the relative proportion of patients with structural organ injuries, fractures and dislocations, of polytraumatized patients, of hospital admissions, of subsequent emergency or semi-elective surgeries and of work-related accidents were evaluated in comparison to the pre-pandemic control. RESULTS: A total of 21,642 patient presentations were included in this study. Significantly less weekly orthopedic trauma emergency patient presentations were recorded during the pandemic (p < 0.01). The MTS was significantly lower during the first lockdown and between lockdowns (p < 0.01). The proportional incidence of overall structural organ injuries, fractures and dislocations, of upper limb fractures/dislocations, of hospital admissions and of patients requiring surgery was significantly increased during the pandemic (p ≤ 0.03). The proportional incidence of work-related injuries was significantly decreased during the pandemic (p < 0.01). CONCLUSIONS: Orthopedic trauma emergency presentations were reduced during the SARS-CoV-2 pandemic. Due to the reluctancy of patients to visit the emergency department during the pandemic, the proportions of relevant injuries in general and of upper limb injuries in particular as well as of patients requiring hospital admission and trauma-related surgery were significantly increased.


Assuntos
COVID-19 , Fraturas Ósseas , Luxações Articulares , Humanos , SARS-CoV-2 , Centros de Traumatologia , COVID-19/epidemiologia , Pandemias/prevenção & controle , Estudos Retrospectivos , Emergências , Controle de Doenças Transmissíveis , Serviço Hospitalar de Emergência , Fraturas Ósseas/epidemiologia , Fraturas Ósseas/cirurgia , Luxações Articulares/epidemiologia
12.
Arch Orthop Trauma Surg ; 143(5): 2467-2474, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-35579703

RESUMO

INTRODUCTION: In regard of surgical training, the reproducible simulation of life-like proximal humerus fractures in human cadaveric specimens is desirable. The aim of the present study was to develop a technique that allows simulation of realistic proximal humerus fractures and to analyse the influence of rotator cuff preload on the generated lesions in regards of fracture configuration. MATERIALS AND METHODS: Ten cadaveric specimens (6 left, 4 right) were fractured using a custom-made drop-test bench, in two groups. Five specimens were fractured without rotator cuff preload, while the other five were fractured with the tendons of the rotator cuff preloaded with 2 kg each. The humeral shaft and the shortened scapula were potted. The humerus was positioned at 90° of abduction and 10° of internal rotation to simulate a fall on the elevated arm. In two specimens of each group, the emergence of the fractures was documented with high-speed video imaging. Pre-fracture radiographs were taken to evaluate the deltoid-tuberosity index as a measure of bone density. Post-fracture X-rays and CT scans were performed to define the exact fracture configurations. Neer's classification was used to analyse the fractures. RESULTS: In all ten cadaveric specimens life-like proximal humerus fractures were achieved. Two III-part and three IV-part fractures resulted in each group. The preloading of the rotator cuff muscles had no further influence on the fracture configuration. High-speed videos of the fracture simulation revealed identical fracture mechanisms for both groups. We observed a two-step fracture mechanism, with initial impaction of the head segment against the glenoid followed by fracturing of the head and the tuberosities and then with further impaction of the shaft against the acromion, which lead to separation of the tuberosities. CONCLUSION: A high energetic axial impulse can reliably induce realistic proximal humerus fractures in cadaveric specimens. The preload of the rotator cuff muscles had no influence on initial fracture configuration. Therefore, fracture simulation in the proximal humerus is less elaborate. Using the presented technique, pre-fractured specimens are available for real-life surgical education. LEVEL OF EVIDENCE: III.


Assuntos
Fraturas do Úmero , Fraturas do Ombro , Humanos , Manguito Rotador/cirurgia , Fraturas do Ombro/cirurgia , Ombro , Úmero , Cadáver
13.
Arch Orthop Trauma Surg ; 143(5): 2519-2527, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-35731264

RESUMO

INTRODUCTION: Open reduction and internal fixation (ORIF) of comminuted coronal shear fractures of the distal humerus is challenging. When a concomitant lateral condyle fracture is present, it may be used for a trans-fracture approach to facilitate exposure and fracture reduction. This study aimed to investigate the frequency of lateral condyle fractures in coronal shear fractures of the distal humerus and analyze fracture reduction, fracture union and clinical results following ORIF through a trans-fracture approach. MATERIALS AND METHODS: All adult patients who underwent treatment for an acute distal humerus fracture during a three-year period in our level-one trauma center were identified. All fractures were classified according to the Orthopaedic Trauma Association (OTA/AO) fracture classification system and all B3 fractures were classified according to the Dubberley classification. B3 fractures with a concomitant radial condyle fracture were identified. The clinical and radiological results, (Mayo Elbow Performance Score = MEPS, Visual Analogue Scale = VAS, range of motion), complications and revision surgeries were analyzed. RESULTS: 53 patients (mean age 52 ± 19 years) were identified. 13 fractures (24.5%) were B3 fractures. Four of them (30.8%) had a concomitant radial condyle fracture. All of these patients underwent ORIF with headless cannulated compression screws and a (postero-)lateral locking plate through a trans-fracture approach. At a minimum follow-up of 24 months, the MEPS was 88 ± 12 points, the VAS was 2 ± 1 and the range of motion was 118° ± 12°. All fractures showed anatomic reduction. One patient developed partial avascular necrosis and underwent arthrolysis at 6 months. One patient underwent partial hardware removal and lateral collateral ligament bracing at 6 months. CONCLUSIONS: Lateral condyle fractures are present in about one third of coronal shear fractures of the distal humerus. This injury can be used for a trans-fracture approach to facilitate exposure and to reliably achieve anatomic fracture reduction.


Assuntos
Articulação do Cotovelo , Fraturas Cominutivas , Fraturas do Úmero , Adulto , Humanos , Pessoa de Meia-Idade , Idoso , Fraturas do Úmero/cirurgia , Fixação Interna de Fraturas/métodos , Úmero , Redução Aberta/métodos , Articulação do Cotovelo/cirurgia , Fraturas Cominutivas/cirurgia , Resultado do Tratamento , Estudos Retrospectivos , Amplitude de Movimento Articular
14.
Arch Orthop Trauma Surg ; 143(2): 857-863, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35064826

RESUMO

BACKGROUND: Lateral collateral ligament (LCL) tears are frequently observed in fractures and dislocations of the elbow. Recent biomechanical evidence suggests that additional ligament augmentation may improve repair stability. The aim of this biomechanical in-vitro study was to compare the resistance of a locking suture repair of the LCL with a ligament augmentation technique. MATERIAL AND METHODS: Eight fresh frozen cadaveric elbows were evaluated for stability against varus/posterolateral rotatory forces (3 Nm). A strain gauge (µm/m; negative values) was placed at the origin and insertion of the lateral ulnar collateral ligament (LUCL) and cyclic loading was performed for 1000 cycles. We analyzed three distinct scenarios: (A) native LCL, (B) locking transosseou suture repair of the LCL, (C) simple LCL repair with additional ligament augmentation of the LUCL. RESULTS: The mean measured strain was - 416.1 µm/m (A), - 618 µm/m (B) and - 288.5 µm/m (C) with the elbow flexion at 90°; the strain was significantly higher in scenario B compared to C (p = .01). During the cyclic load (1000) the mean measured strain was - 523.1 µm/m (B) and - 226.3 µm/m (C) with the elbow flexion at 60°; the strain was significantly higher in scenario B compared to C (p = .01). No significant difference between the first and the last cycles was observed (p = .09; p = .07). One failure of the LCL repair was observed after 1000 cycles; none of the ligament augmentations failed. CONCLUSION: Ligament augmentation (C) provides higher resistance compared to the native LCL (A) and to the locking suture repair technique (B). Both techniques, however, hold up during 1000 cycles. While ligament augmentation might enhance the primary stability of the repair, future clinical studies have to show whether this increase in resistance leads to negative effects like higher rates of posttraumatic elbow stiffness. LEVEL OF EVIDENCE: Basic science study, biomechanics.


Assuntos
Ligamentos Colaterais , Articulação do Cotovelo , Instabilidade Articular , Ligamentos Laterais do Tornozelo , Humanos , Cotovelo , Instabilidade Articular/cirurgia , Articulação do Cotovelo/cirurgia , Amplitude de Movimento Articular , Fenômenos Biomecânicos , Cadáver , Suturas , Ligamentos Colaterais/cirurgia , Ligamentos Colaterais/lesões
15.
Arch Orthop Trauma Surg ; 143(5): 2383-2393, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-35482109

RESUMO

INTRODUCTION: Stiffness after elbow injuries can severely limit daily life. If adequate conservative treatment does not result in satisfactory improvement of elbow function, surgical intervention should be considered. Whether an open or arthroscopic procedure is preferable is still a topic of debate and a systematic review of functional outcomes is lacking. MATERIALS AND METHODS: We systematically reviewed the available literature searching electronic databases, MEDLINE using the PubMed interface and EMBASE, for studies published between 2013 and 2021. Primary objective was to compare open and arthroscopic arthrolysis' functional outcomes, respectively, especially ROM and MEPS, as well as the accompanied complications. The PRISMA guidelines were applied. RESULTS: 27 studies comprising 1666 patients were included. 1059 patients (63.6%) were treated with open arthrolysis, and 607 patients (36.4%) were treated with arthroscopic arthrolysis. The results presented indicate satisfactory outcomes in open and arthroscopic arthrolysis with regard to functional outcome parameters. Treatment success, defined as excellent or good results according to the Mayo Elbow Performance Score, among the patients treated with an open procedure was 88.8%; 6.3% required revision whereas 18.1% had complications without the need for revision surgery. Within the cohort of arthroscopically treated patients, treatment success was 91.8%. Revisions and complications without further surgical intervention were significantly less frequent than in the open cohort, at 1.6% and 9.1%, respectively. CONCLUSIONS: Both open and arthroscopic arthrolysis provide good to excellent functional outcomes. Since the number of complications and revision increases with the invasiveness of the treatment, an arthroscopic procedure might be favored if feasible by indication. The role of forearm rotation and the use of a hinged external fixator remains of interest. STUDY DESIGN: Level IV; Systematic review.


Assuntos
Articulação do Cotovelo , Artropatias , Procedimentos Ortopédicos , Humanos , Cotovelo/cirurgia , Articulação do Cotovelo/cirurgia , Artropatias/cirurgia , Procedimentos Ortopédicos/efeitos adversos , Amplitude de Movimento Articular , Estudos Retrospectivos , Resultado do Tratamento
16.
Arch Orthop Trauma Surg ; 143(7): 4111-4116, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-36197491

RESUMO

PURPOSE: The optimal screw placement in arthroscopically assisted fixation of radial head fractures is still an issue and no guiding methods have been evaluated in the recent literature. The study hypothesis was that using a "reference k-wire" percutaneously inserted in and parallel to the radiocapitellar joint would enable to achieve a trajectory more parallel to the radial head articular surface as compared to a free-hand k-wire placement. METHODS: Arthroscopically assisted placement of a k-wire in the radial head was performed in seven fresh-frozen human cadaver specimens by three surgeons. Three different techniques were evaluated: freehand drilling (technique A), placement using a "reference" k-wire in the radiocapitellar joint as a reference without (technique B), and with the AO parallel k-wire guide (technique C). Radiographs from all procedures were obtained and the inclination angle "α" between the k-wire and the articular surface of the radial head was measured and compared among the techniques. RESULTS: Angles of 84 radiographs were obtained and showed a mean α angle of 30.1° ± 13° for technique A, 5.7° ± 4.5° for technique B, and 5.4° ± 3.7° for technique C. The angle α was significantly higher with technique A as compared to B (p < 0.0001) and C (p < 0.0001). There was no difference between methods B and C (n.s.). No difference was observed among the surgeons for all three methods (p = 0.66). CONCLUSION: With the use of an additional "reference" k-wire placed in the radiocapitellar joint, the guiding k-wire for screw drilling can be placed almost parallel to the radial head joint line with limited variability and a good reproducibility during arthroscopically assisted radial head fracture fixation. CLINICAL RELEVANCE: The here-presented method of an additional, percutaneous introduced "reference" k-wire is easily applicable and helpful to achieve parallel screw placement during arthroscopically assisted radial head fracture fixation. LEVEL OF EVIDENCE: IV, biomechanical cadaver study.


Assuntos
Articulação do Cotovelo , Fraturas da Cabeça e do Colo do Rádio , Fraturas do Rádio , Humanos , Reprodutibilidade dos Testes , Parafusos Ósseos , Fios Ortopédicos , Fraturas do Rádio/cirurgia , Fixação Interna de Fraturas/métodos , Articulação do Cotovelo/cirurgia , Cadáver
17.
Arch Orthop Trauma Surg ; 143(7): 4229-4237, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-36512058

RESUMO

INTRODUCTION: The aim of the present study was to develop a technical process to reproducibly generate terrible triad injuries (TTI) in fresh-frozen human cadaveric specimens, while leaving the skin intact. Such "pre-fractured" specimens, used for scientific analysis and for surgical education, might help to improve current treatment, which is complex and prone to complications. MATERIALS AND METHODS: To induce the desired fractures, a custom-made fracturing unit was used to apply an axial force on the extended cadaveric elbow specimens, with the forearm pronated and under valgus load. To simulate the valgus load, a pneumatic cylinder was developed to apply valgus stress to the joint by an additional force vector from the lateral side of the joint. RESULTS: The success rate of TTI induction was 92.3% (12/13). Of the 12 radial head fractures, 3 (25%) were classified Mason type II and 9 (75%) Mason type III. The coronoid fractures were grouped in tip subtype 2 (5 fractures, 41.7%), anteromedial facet (AMF) subtype 2 (4 fractures, 33.3%), AMF subtype 3 (1 fracture, 8.3%) and basal subtype 1 (2 fractures, 16.7%). CONCLUSIONS: The present study provides an instrument for successful and reproducible production of dislocation fracture patterns with their typical accompanying soft tissue lesions. The methodology might be applied on a broad basis to be able to perform biomechanical studies regarding primary stability of fixation concepts for TTI and to educate surgeons in a fairly realistic scenario with the surgical treatment of TTI.


Assuntos
Lesões no Cotovelo , Articulação do Cotovelo , Luxações Articulares , Fraturas do Rádio , Fraturas da Ulna , Humanos , Luxações Articulares/cirurgia , Fraturas do Rádio/cirurgia , Articulação do Cotovelo/cirurgia , Cadáver , Fraturas da Ulna/cirurgia
18.
J Hand Surg Am ; 2022 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-36400651

RESUMO

PURPOSE: Indirect fixation of coronoid process fractures of the ulna, especially arthroscopically, offers the possibility to avoid extensive medial surgical approaches. However, optimal placement of K-wires for cannulated screw fixation is technically challenging. The aim of the present study was to present guide values for K-wire placement for indirect screw fixation of coronoid tip (COT) and anteromedial facet (AMF) fractures of the ulna. METHODS: Computed tomography scans of the elbows of 197 patients with an uninjured ulna were identified and evaluated following a standard measuring protocol. Optimal placement of K-wires was defined as the bisector between the anterior and articular cortex while respecting a 1.6-mm safe zone for each placement. This placement of the K-wires in the COT and the AMF was analyzed by measuring the wire angulation in relation to the posterior ulnar cortex (AUC), the distance from the entry point to the posterior olecranon edge (DPE), and the intraosseous length (IOL). Because the coronoid has a curved shape, measurements of the COT and AMF were expected to differ significantly. Sex was also expected to influence measurements. To determine whether this optimal placement of K-wires can be reliably identified, interobserver and intraobserver reliabilities were evaluated. RESULTS: To address tip fragments, we determined a mean AUC of 64°, DPE of 36 mm, and IOL of 38 mm. Regarding wire placement toward the AMF, the means for the AUC, DPE, and IOL were 79°, 27 mm, and 33 mm, respectively. Statistically significant differences were found between the COT and the AMF for the AUC, DPE, and IOL. Our measuring protocol showed good interobserver and intraobserver reliability. CONCLUSIONS: K-wire placement toward the COT demands a smaller angle, a longer IOL, and a more distal entry point than wires placed toward AMF. These differences reflect the curved and complex anatomy of the coronoid. CLINICAL RELEVANCE: This measuring algorithm can be used to plan osteosynthesis, and the obtained reference values can help understand the coronoid's complex anatomy.

19.
Int Orthop ; 46(11): 2603-2610, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-36042057

RESUMO

PURPOSE: Interposition arthroplasty for the post-traumatic osteoarthritic elbow is a salvage procedure used in young and active patients and remains a rare and unexplored therapeutic option. METHODS: We systematically reviewed the available literature searching electronic databases, MEDLINE using the PubMed interface and EMBASE. The primary objective was to synthesize functional outcomes and to investigate revision frequencies, but also complication and subsequent surgery rates among patients with surviving grafts. The preferred reporting guidelines for systematic reviews and meta-analyses guidelines were applied. RESULTS: Five studies were left for inclusion, all retrospective in design, comprising 67 patients. The mean age was 40 years, the mean follow-up period was 61 months, and 68.2% of the patients treated were male. Eleven patients (16.4%) were treated with fascia lata autografts, and 56 patients (83.6%) were treated with Achilles tendon allografts. The graft survived in 53 patients (79.1%); the post-operative Mayo Elbow Performance Score averaged 69 points. Fourteen patients (20.9%) required revision surgery. In the setting of graft survival, 39.1% of patients had complications not requiring further surgical treatment and 5.7% of patients with surviving grafts needed subsequent operative treatment within the follow-up period. CONCLUSION: Given graft survival, this systematic review demonstrated satisfactory functional outcomes following interposition arthroplasty of the post-traumatic osteoarthritic elbow, however, associated with a cumulative complication and subsequent operative treatment rate of 44.8%. In addition, a revision rate of 20.9% needs to be expected. Varus-valgus instability in the pre-operative clinical assessment seems to be associated with unsatisfactory post-operative elbow function. The superiority of either of the two main reported graft methods (fascia lata autograft and Achilles tendon allograft) remains pending, and the role of an external fixator in preventing post-operative instability remains unresolved.


Assuntos
Articulação do Cotovelo , Osteoartrite , Adulto , Artroplastia/efeitos adversos , Artroplastia/métodos , Cotovelo/cirurgia , Articulação do Cotovelo/cirurgia , Feminino , Humanos , Masculino , Osteoartrite/etiologia , Osteoartrite/cirurgia , Estudos Retrospectivos , Resultado do Tratamento
20.
J Shoulder Elbow Surg ; 31(8): 1666-1673, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35247574

RESUMO

BACKGROUND: The purpose of this study was to investigate the primary stability and displacement tendencies of an external fixation system in 2 different configurations in comparison to locking plate fixation in a 3-part proximal humeral fracture model. METHODS: Twenty-one fresh-frozen human cadaveric proximal humeral specimens were divided into 3 groups of 7 stripped specimens. An unstable 3-part fracture of the proximal humerus was set. Construct A consisted of the Galaxy Fixation Shoulder System, with fixation in accordance with the manufacturer's recommended technique (3 pairs of threaded wires). Construct B was fixed with an additional pair of threaded wires according to the recommendations of Gumina et al (4 pairs of threaded wires). The remaining 7 specimens were fixed with a locking plate. By use of an optical motion capture system, relative motion at the fracture site and failure load were evaluated during a cyclic loading protocol. RESULTS: Plate osteosynthesis showed the highest cyclic load to failure (895 ± 239 N; range, 597-1135 N), followed by construct B (692 ± 121 N; range, 432-788 N) and construct A (350 ± 190 N; range, 139-615 N). Statistically significant differences were found between plating and construct A (P < .001), between plating and construct B (P = .031), and between construct B and construct A (P = .013). Relative motion at the fracture site, in terms of change in distance during cyclic loading, was lowest with construct B measured at the peak load of 395 N after 11 steps (1.73 ± 1.98 mm; range, 0.53-5.96 mm) and highest with construct A (8.46 ± 10.67 mm; range, 2.26-20.79 mm). Angular change measured at the peak load after 11 steps was lowest with construct B (1.19° ± 0.36°; range, 0.59°-1.7°) and highest with construct A (2.44° ± 1.63°; range, 0.77°-4.04°). Statistically significant differences were found between construct A and construct B and between construct A and plating at various steps of cyclic loading. CONCLUSION: In this biomechanical study of unstable 3-part proximal humeral fractures, locking plate osteosynthesis demonstrated the highest possible load application. External fixator application with 8 threaded wires (construct B) revealed the least relative motion at the fracture site, without a statistically significant difference compared with locking plates. It therefore represents another valid technique for treatment regarding primary stability. The use of external fixator application with 6 threaded wires (construct A) resulted in the lowest stability and the highest rates of displacement.


Assuntos
Fraturas do Úmero , Fraturas do Ombro , Fenômenos Biomecânicos , Placas Ósseas , Cadáver , Fixadores Externos , Fixação de Fratura/métodos , Fixação Interna de Fraturas/métodos , Humanos , Úmero/cirurgia , Ombro , Fraturas do Ombro/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA