Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Clin Transl Oncol ; 23(11): 2358-2367, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34043153

RESUMO

PURPOSE: To explore the feasibility of image-guided and respiratory-gated Stereotactic Body Radiation Therapy (SBRT) for Accelerated Partial Breast Irradiation (APBI) in patients with very early breast cancer. MATERIAL AND METHODS: Selected patients with early breast carcinoma after breast-conserving surgery were enrolled in this phase II trial. A fiducial marker was percutaneously placed close to surgical bed and five external fiducials were set on the skin. A CT scan for planning was acquired at free breathing. The treatment was planned and DVH were assessed according to international recommendations. Prescription dose was 30 Gy in five consecutive fractions of 6 Gy. A 6MV monoenergetic LINAC (linear accelerator) that combines stereoscopic X-ray imaging system and ExacTrac Adaptive Gating technique was used. PTV (planning target volume) intrafraction motion was controlled and PTV was irradiated in a selected gated area of the respiratory cycle. Shifts for a correct, gated set-up were calculated and automatically applied. RESULTS: Between April 2013 and October 2015, a total of 23 patients were included. The median tumor size was 12 mm. The mean PTV volume was 114 cc. The mean ipsilateral lung V9 Gy was 2.2% and for left-sided breast cancers, the volume of the heart receiving 1.5 Gy was 11.5%. Maximum skin dose was 30.8 Gy. Acute toxicity was grade1 in all the patients and 100% experienced excellent/good breast cosmesis outcomes. With a median follow-up of 66 months (range 8-99 months) local-relapse-free-survival reaches 100%. One patient developed a second breast cancer outside the treated quadrant after 25.1 months. CONCLUSION: APBI with SBRT and ExacTrac Adaptive Gating System was feasible. The acute and late toxicities were almost null and cosmesis was excellent. We also found that the margins of 5 mm applied from CTV to PTV were sufficient to compensate for geometric uncertainties.


Assuntos
Neoplasias da Mama/radioterapia , Carcinoma Ductal de Mama/radioterapia , Radiocirurgia/métodos , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Neoplasias da Mama/cirurgia , Carcinoma Ductal de Mama/diagnóstico por imagem , Carcinoma Ductal de Mama/patologia , Carcinoma Ductal de Mama/cirurgia , Intervalo Livre de Doença , Fracionamento da Dose de Radiação , Estudos de Viabilidade , Feminino , Marcadores Fiduciais , Coração/efeitos da radiação , Humanos , Pulmão/efeitos da radiação , Mastectomia Segmentar , Pessoa de Meia-Idade , Movimentos dos Órgãos , Órgãos em Risco/efeitos da radiação , Cuidados Pós-Operatórios/métodos , Estudos Prospectivos , Radiocirurgia/instrumentação , Respiração , Pele/efeitos da radiação , Fatores de Tempo , Tomografia Computadorizada por Raios X , Carga Tumoral
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA