Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 28
Filtrar
1.
J Am Coll Cardiol ; 81(17): 1663-1674, 2023 05 02.
Artigo em Inglês | MEDLINE | ID: mdl-36882136

RESUMO

BACKGROUND: Randomized data comparing outcomes of transcatheter aortic valve replacement (TAVR) with surgery in low-surgical risk patients at time points beyond 2 years is limited. This presents an unknown for physicians striving to educate patients as part of a shared decision-making process. OBJECTIVES: The authors evaluated 3-year clinical and echocardiographic outcomes from the Evolut Low Risk trial. METHODS: Low-risk patients were randomized to TAVR with a self-expanding, supra-annular valve or surgery. The primary endpoint of all-cause mortality or disabling stroke and several secondary endpoints were assessed at 3 years. RESULTS: There were 1,414 attempted implantations (730 TAVR; 684 surgery). Patients had a mean age of 74 years and 35% were women. At 3 years, the primary endpoint occurred in 7.4% of TAVR patients and 10.4% of surgery patients (HR: 0.70; 95% CI: 0.49-1.00; P = 0.051). The difference between treatment arms for all-cause mortality or disabling stroke remained broadly consistent over time: -1.8% at year 1; -2.0% at year 2; and -2.9% at year 3. The incidence of mild paravalvular regurgitation (20.3% TAVR vs 2.5% surgery) and pacemaker placement (23.2% TAVR vs 9.1% surgery; P < 0.001) were lower in the surgery group. Rates of moderate or greater paravalvular regurgitation for both groups were <1% and not significantly different. Patients who underwent TAVR had significantly improved valve hemodynamics (mean gradient 9.1 mm Hg TAVR vs 12.1 mm Hg surgery; P < 0.001) at 3 years. CONCLUSIONS: Within the Evolut Low Risk study, TAVR at 3 years showed durable benefits compared with surgery with respect to all-cause mortality or disabling stroke. (Medtronic Evolut Transcatheter Aortic Valve Replacement in Low Risk Patients; NCT02701283).


Assuntos
Insuficiência da Valva Aórtica , Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Acidente Vascular Cerebral , Substituição da Valva Aórtica Transcateter , Humanos , Feminino , Idoso , Masculino , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/cirurgia , Fatores de Risco , Resultado do Tratamento , Estudos Prospectivos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Próteses Valvulares Cardíacas/efeitos adversos , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/cirurgia
3.
J Thorac Cardiovasc Surg ; 164(1): 2-10.e5, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-33220972

RESUMO

OBJECTIVE: Positive remodeling after thoracic endovascular aortic repair (TEVAR) for chronic thoracic aortic dissection is variable due to incomplete distal seal and retrograde false lumen perfusion. We assessed the outcomes of adjunctive balloon fracture fenestration (BFF) during TEVAR in patients with chronic aortic dissection complicated by negative remodeling. METHODS: From June 2013 to January 2016, 49 patients with chronic aortic dissection complicated by aneurysm due to negative remodeling underwent TEVAR with BFF. Contrast-enhanced computed tomography was performed before discharge, at 3 to 6 months, and annually. RESULTS: Intraoperatively, endovascular stent graft expansion was achieved in all patients. There was 1 hospital death due to visceral malperfusion related to acute-on-chronic dissection noted before planned BFF. There were no occurrences of paraplegia, 3 patients had stroke, and 3 had acute renal failure. Survival at 1 year was 91%. Late reintervention for incomplete false lumen exclusion was required in 16 patients and freedom from reintervention was 75% at 1 year. Thirty-six patients (73.5%) had complete false lumen thrombosis through the treated segment. True lumen area increased following TEVAR with BFF and continued to incrementally expand with subsequent aortic remodeling at 1-year follow-up. Thirteen patients had positive remodeling, defined as thrombosis of false lumen, ≥10% decrease in aortic dimension, and ≥10% increase in true lumen diameter. Patients with positive remodeling had an average decrease of 11 mm in maximal aortic diameter at final follow-up. CONCLUSIONS: BFF of chronic dissection membrane is a beneficial adjunct to TEVAR during short-term follow-up and may promote positive aortic remodeling and is worthy of further study.


Assuntos
Aneurisma da Aorta Torácica , Dissecção Aórtica , Implante de Prótese Vascular , Procedimentos Endovasculares , Trombose , Dissecção Aórtica/diagnóstico por imagem , Dissecção Aórtica/cirurgia , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/cirurgia , Aortografia/métodos , Prótese Vascular , Implante de Prótese Vascular/efeitos adversos , Procedimentos Endovasculares/métodos , Humanos , Estudos Retrospectivos , Stents , Trombose/cirurgia , Fatores de Tempo , Resultado do Tratamento , Remodelação Vascular
4.
J Heart Lung Transplant ; 40(11): 1408-1418, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34334301

RESUMO

BACKGROUND: Given the shortage of suitable donor hearts for cardiac transplantation and the growing interest in donation after circulatory death (DCD), our institution recently began procuring cardiac allografts from DCD donors. METHODS: Between October 2020 and March 2021, 15 patients with heart failure underwent cardiac transplantation using DCD allografts. Allografts were procured using a modified extracorporeal membrane oxygenation circuit for thoracic normothermic regional perfusion (TA-NRP) and were subsequently transported using cold static storage. Data collection and analysis were performed with institutional review board approval. RESULTS: The mean age of the DCD donors was 23 ± 7 years and average time on TA-NRP was 56 ± 8 minutes. Total ischemic time was 183 ± 31 minutes and distance from transplant center was 373 ± 203 nautical miles. Recipient age was 55 ± 14 years, with 8 (55.3%) recipients on durable left ventricular assist device support. Post-transplant, 6 (40%) recipients experienced mild left ventricle primary graft dysfunction (PGD-LV), 3 (20%) recipients experienced moderate PGD-LV, and no recipients experienced severe PGD-LV. Postoperative transthoracic echocardiogram demonstrated left ventricular ejection fraction >55% in all recipients. One recipient (6.6%) developed International Society for Heart and Lung Transplantation 2R acute cellular rejection on first biopsy. At last follow-up, all 15 recipients were alive past 30-days. CONCLUSIONS: Cardiac DCD provides an opportunity to increase the availability of donor hearts for transplantation. Utilizing TA-NRP with cold static storage, we have extended the cold ischemic time of DCD allografts to almost 3 hours, allowing for inter-hospital organ transport.


Assuntos
Isquemia Fria/métodos , Rejeição de Enxerto/prevenção & controle , Insuficiência Cardíaca/cirurgia , Transplante de Coração/métodos , Preservação de Órgãos/métodos , Perfusão/métodos , Obtenção de Tecidos e Órgãos/métodos , Adolescente , Adulto , Criança , Feminino , Seguimentos , Sobrevivência de Enxerto , Humanos , Masculino , Estudos Retrospectivos , Fatores de Tempo , Adulto Jovem
5.
J Card Surg ; 36(10): 3619-3628, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34235763

RESUMO

BACKGROUND: On October 18, 2018, several changes to the donor heart allocation system were enacted. We hypothesize that patients undergoing orthotopic heart transplantation (OHT) under the new allocation system will see an increase in ischemic times, rates of primary graft dysfunction, and 1-year mortality due to these changes. METHODS: In this single-center retrospective study, we reviewed the charts of all OHT patients from October 2017 through October 2019. Pre- and postallocation recipient demographics were compared. Survival analysis was performed using the Kaplan-Meier method. RESULTS: A total of 184 patients underwent OHT. Recipient demographics were similar between cohorts. The average distance from donor increased by more than 150 km (p = .006). Patients in the postallocation change cohort demonstrated a significant increase in the rate of severe left ventricle primary graft dysfunction from 5.4% to 18.7% (p = .005). There were no statistically significant differences in 30-day mortality or 1-year survival. Time on the waitlist was reduced from 203.8 to 103.7 days (p = .006). CONCLUSIONS: Changes in heart allocation resulted in shorter waitlist times at the expense of longer donor distances and ischemic times, with an associated negative impact on early post-transplantation outcomes. No significant differences in 30-day or 1-year mortality were observed.


Assuntos
Transplante de Coração , Adulto , Humanos , Estudos Retrospectivos , Análise de Sobrevida , Doadores de Tecidos , Listas de Espera
6.
Br J Anaesth ; 126(3): 599-607, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33549321

RESUMO

BACKGROUND: Increased intravascular volume has been associated with protection from acute kidney injury (AKI), but in patients with congestive heart failure, venous congestion is associated with increased AKI. We tested the hypothesis that intraoperative venous congestion is associated with AKI after cardiac surgery. METHODS: In patients enrolled in the Statin AKI Cardiac Surgery trial, venous congestion was quantified as the area under the curve (AUC) of central venous pressure (CVP) >12, 16, or 20 mm Hg during surgery (mm Hg min). AKI was defined using Kidney Disease Improving Global Outcomes (KDIGO) criteria and urine concentrations of tissue inhibitor of metalloproteinase-2 and insulin-like growth factor binding protein 7 ([TIMP-2]⋅[IGFBP7]), a marker of renal stress. We measured associations between venous congestion, AKI and [TIMP-2]⋅[IGFBP7], adjusted for potential confounders. Values are reported as median (25th-75th percentile). RESULTS: Based on KDIGO criteria, 104 of 425 (24.5%) patients developed AKI. The venous congestion AUCs were 273 mm Hg min (81-567) for CVP >12 mm Hg, 66 mm Hg min (12-221) for CVP >16 mm Hg, and 11 mm Hg min (1-54) for CVP >20 mm Hg. A 60 mm Hg min increase above the median venous congestion AUC above each threshold was independently associated with increased AKI (odds ratio=1.06; 95% confidence interval [CI], 1.02-1.10; P=0.008; odds ratio=1.12; 95% CI, 1.02-1.23; P=0.013; and odds ratio=1.30; 95% CI, 1.06-1.59; P=0.012 for CVP>12, >16, and >20 mm Hg, respectively). Venous congestion before cardiopulmonary bypass was also associated with increased [TIMP-2]⋅[IGFBP7] measured during cardiopulmonary bypass and after surgery, but neither venous congestion after cardiopulmonary bypass nor venous congestion throughout surgery was associated with postoperative [TIMP-2]⋅[IGFBP7]. CONCLUSION: Intraoperative venous congestion was independently associated with increased AKI after cardiac surgery.


Assuntos
Injúria Renal Aguda/etiologia , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Pressão Venosa Central , Hiperemia/etiologia , Injúria Renal Aguda/epidemiologia , Idoso , Estudos de Coortes , Feminino , Humanos , Hiperemia/epidemiologia , Período Intraoperatório , Masculino , Estudos Prospectivos , Fatores de Risco , Resultado do Tratamento
7.
Ann Thorac Surg ; 111(4): 1258-1263, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-32896546

RESUMO

BACKGROUND: Bundled payments for coronary artery bypass grafting (CABG) provide a single reimbursement for care provided from admission through 90 days post-discharge. We aim to explore the impact of complications on total institutional costs, as well as the drivers of high costs for index hospitalization. METHODS: We linked clinical and internal cost data for patients undergoing CABG from 2014 to 2017 at a single institution. We compared unadjusted average variable direct costs, reporting excess cost from an uncomplicated baseline. We stratified by The Society of Thoracic Surgeons preoperative risk and quality outcome measures as well as value-based outcomes (readmission, post-acute care utilization). We performed multivariable linear regression to evaluate drivers of high costs, adjusting for preoperative and intraoperative characteristics and postoperative complications. RESULTS: We reviewed 1789 patients undergoing CABG with an average of 2.7 vessels (SD 0.89). A significant proportion of patients were diabetic (51.2%) and obese (mean body mass index 30.6, SD 6.1). Factors associated with increased adjusted costs were preoperative renal failure (P = .001), diabetes (P = .001) and body mass index (P = .05), and postoperative stroke (P < .001), prolonged ventilation (P < .001), rebleeding requiring reoperation (P < .001) and renal failure (P < .001) with varying magnitude. Preoperative ejection fraction and insurance status were not associated with increased adjusted costs. CONCLUSIONS: Preoperative characteristics had less of an impact on costs post-CABG than postoperative complications. Postoperative complications vary in their impact on internal costs, with reoperation, stroke, and renal failure having the greatest impact. In preparation for bundled payments, hospitals should focus on understanding and preventing drivers of high cost.


Assuntos
Ponte de Artéria Coronária/economia , Doença da Artéria Coronariana/cirurgia , Custos Hospitalares , Complicações Pós-Operatórias/economia , Doença da Artéria Coronariana/economia , Análise Custo-Benefício , Feminino , Recursos em Saúde/economia , Humanos , Masculino , Pessoa de Meia-Idade , Reoperação , Estudos Retrospectivos , Fatores de Risco
8.
JTCVS Open ; 3: 128-135, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34173545

RESUMO

OBJECTIVE: The American Board of Thoracic Surgery-certifying examination is challenging for applicants. Single institutions have reported good results with a mock oral examination (MOE) for trainees. General surgery literature has demonstrated success with in-person multi-institutional MOE examinations. Due to small numbers of cardiothoracic training programs and significant geographic variability, we hypothesized that a multi-institutional, collaborative remotely administered MOE (mICMO) pairing faculty with trainees from different institutions would provide an important educational experience. METHODS: mICMOs were conducted via the Zoom virtual platform across 6 institutions. Descriptive results via post-experience survey were analyzed and reported. RESULTS: In total, 100% of trainees found mICMO useful. The majority would recommend to a peer, and 100% of faculty examiners found mICMO useful and would participate in another examination. CONCLUSIONS: Faculty and trainees found the experience to be effective with respect to creating a high-stakes environment, educationally beneficial, and productive. These results support the continued use of mICMO and encourage expansion and collaboration with additional institutions across the country.

9.
J Card Surg ; 35(2): 375-382, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31794089

RESUMO

BACKGROUND: Patients with bicuspid aortic valves (BAV) are heterogeneous with regard to patterns of root remodeling and valvular dysfunction. Two-dimensional echocardiography is the standard surveillance modality for patients with aortic valve dysfunction. However, ancillary computed tomography or magnetic resonance imaging is often necessary to characterize associated patterns of aortic root pathology. Conversely, the pairing of three-dimensional (3D) echocardiography with novel quantitative modeling techniques allows for a single modality description of the entire root complex. We sought to determine 3D aortic valve and root geometry with this quantitative approach. METHODS: Transesophageal real-time 3D echocardiography was performed in five patients with tricuspid aortic valves (TAV) and in five patients with BAV. No patient had evidence of valvular dysfunction or aortic root pathology. A customized image analysis protocol was used to assess 3D aortic annular, valvular, and root geometry. RESULTS: Annular, sinus and sinotubular junction diameters and areas were similar in both groups. Coaptation length and area were higher in the TAV group (7.25 ± 0.98 mm and 298 ± 118 mm2 , respectively) compared to the BAV group (5.67 ± 1.33 mm and 177 ± 43 mm2 ; P = .07 and P = .01). Cusp surface area to annular area, coaptation height, and the sub- and supravalvular tenting indices did not differ significantly between groups. CONCLUSIONS: Single modality 3D echocardiography-based modeling allows for a quantitative description of the aortic valve and root geometry. This technique together with novel indices will improve our understanding of normal and pathologic geometry in the BAV population and may help to identify geometric predictors of adverse remodeling and guide tailored surgical therapy.


Assuntos
Aorta/diagnóstico por imagem , Valva Aórtica/diagnóstico por imagem , Ecocardiografia Tridimensional/métodos , Doenças das Valvas Cardíacas/diagnóstico por imagem , Idoso , Aorta/patologia , Valva Aórtica/patologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
10.
Ann Thorac Surg ; 108(3): 700-707, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-31034827

RESUMO

BACKGROUND: Damage to the cardiac conduction system requiring permanent pacemaker implantation is a complication of aortic valve replacement (AVR) that may importantly affect quality of life. We investigated the prevalence of and preprocedure risk factors for new permanent pacemakers after surgical (SAVR) and transcatheter AVR (TAVR) at a single institution. METHODS: Preoperative variables and baseline electrocardiograms were reviewed for 5807 patients undergoing elective SAVR, with or without coronary artery bypass grafting, and 1292 undergoing TAVR, with or without percutaneous coronary intervention, from 2006 to 2017 at Cleveland Clinic. Patients with previous permanent pacemakers were excluded. Risk factors for permanent pacemaker implantation were identified using multivariable logistic regression analysis. RESULTS: New permanent pacemakers were implanted in 151 (2.6%) after SAVR and in 125 (9.7%) after TAVR (whole group SAVR vs TAVR, P <.0001). Risk factors for pacemaker implantation after TAVR included preoperative conduction disturbances and type of prosthesis (SAPIEN, 9.5%; SAPIEN XT, 4.8%; SAPIEN 3, 10% [Edwards Lifesciences, Irvine, CA]; CoreValve, 30% [Medtronic, Minneapolis, MN]; and other TAVR, 10%). There were no reliable risk factors for pacemaker implantation after SAVR. Bicuspid valves, mechanical vs bioprosthetic valves, higher Society of Thoracic Surgeons risk score, and concomitant coronary artery bypass grafting were not associated with elevated risk. CONCLUSIONS: At a high-volume institution in the current era, establishing a baseline for pacemaker implantation after AVR is necessary. Preoperative conduction disturbances and transcatheter valve type affect its prevalence. These data provide a benchmark that should be taken into account when considering TAVR in low-risk patients.


Assuntos
Estimulação Cardíaca Artificial/métodos , Marca-Passo Artificial/efeitos adversos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Centros Médicos Acadêmicos , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Benchmarking , Estimulação Cardíaca Artificial/efeitos adversos , Estudos de Coortes , Feminino , Hospitais com Alto Volume de Atendimentos , Humanos , Assistência de Longa Duração , Masculino , Marca-Passo Artificial/estatística & dados numéricos , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/fisiopatologia , Complicações Pós-Operatórias/terapia , Prevalência , Prognóstico , Estudos Retrospectivos , Fatores de Risco , Análise de Sobrevida , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento
12.
Ann Thorac Surg ; 103(2): 533-540, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-27788942

RESUMO

BACKGROUND: Less-invasive techniques have previously been described for mitral and aortic valve operations; however, few studies have examined their benefit for aortic root and ascending aorta reconstruction. Using propensity matching, we compared outcomes of patients undergoing proximal aortic operations through a J incision compared with full sternotomy. METHODS: From January 1995 to January 2014, 8,533 patients underwent proximal aortic operations at Cleveland Clinic. The study population comprised 1,827 patients after those with prior cardiac operations, emergency procedures, endocarditis, or circulatory arrest were excluded; 568 (31%) underwent a J incision. A propensity score based on 57 variables was generated to account for differences in characteristics of full-sternotomy and J-incision patients, producing 483 matched patient pairs (85% of possible) for comparison of outcomes. RESULTS: Among propensity-matched patients, in-hospital mortality (0 [0%] J incision vs 2 [0.41%] full sternotomy; p = 0.2), renal failure (3 [0.62%] vs 6 [1.2%]; p = 0.3), stroke (3 [0.62%] vs 3 [0.62%; p > 0.9), reoperation for bleeding (17 [3.5%] vs 15 [3.1%]; p = 0.7), intraoperative blood products (60 [15%] vs 78 [19%]; p = 0.08), and postoperative transfusions (97 [20%] vs 103 [22%]; p = 0.6) were similar. Intensive care unit (median 24 vs 26 hours) and postoperative hospital stays (median 5.2 vs 6.0 days) were shorter (p < 0.0001) for the J incision, and operative and postoperative direct technical costs were 6% less. CONCLUSIONS: A J incision is a feasible technique for primary isolated elective proximal aortic operations, with a low risk of complications similar to those of full sternotomy, but with the advantages of shorter intensive care unit and hospital stays, lower costs, and better cosmesis.


Assuntos
Aorta/cirurgia , Valva Aórtica/cirurgia , Procedimentos Cirúrgicos Cardíacos/métodos , Doenças das Valvas Cardíacas/cirurgia , Mortalidade Hospitalar , Adulto , Idoso , Valva Aórtica/fisiopatologia , Procedimentos Cirúrgicos Cardíacos/mortalidade , Estudos de Coortes , Feminino , Seguimentos , Doenças das Valvas Cardíacas/diagnóstico por imagem , Doenças das Valvas Cardíacas/mortalidade , Humanos , Masculino , Pessoa de Meia-Idade , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Procedimentos Cirúrgicos Minimamente Invasivos/mortalidade , Duração da Cirurgia , Complicações Pós-Operatórias/mortalidade , Complicações Pós-Operatórias/fisiopatologia , Pontuação de Propensão , Estudos Retrospectivos , Esternotomia/métodos , Esternotomia/mortalidade , Análise de Sobrevida , Toracoscopia/métodos , Toracoscopia/mortalidade , Fatores de Tempo , Resultado do Tratamento
13.
J Thorac Cardiovasc Surg ; 152(3): 847-59, 2016 09.
Artigo em Inglês | MEDLINE | ID: mdl-27530639

RESUMO

OBJECTIVES: Repair for ischemic mitral regurgitation with undersized annuloplasty is characterized by high recurrence rates. We sought to determine the value of pre-repair 3-dimensional echocardiography over 2-dimensional echocardiography in predicting recurrence at 6 months. METHODS: Intraoperative transesophageal 2-dimensional echocardiography and 3-dimensional echocardiography were performed in 50 patients undergoing undersized annuloplasty for ischemic mitral regurgitation. Two-dimensional echocardiography annular diameter and tethering parameters were measured in the apical 2- and 4-chamber views. A customized protocol was used to assess 3-dimensional annular geometry and regional leaflet tethering. Recurrence (grade ≥2) was assessed with 2-dimensional transthoracic echocardiography at 6 months. RESULTS: Preoperative 2- and 3-dimensional annular geometry were similar in all patients with ischemic mitral regurgitation. Preoperative 2- and 3-dimensional leaflet tethering were significantly higher in patients with recurrence (n = 13) when compared with patients without recurrence (n = 37). Multivariate logistic regression revealed preoperative 2-dimensional echocardiography posterior tethering angle as an independent predictor of recurrence with an optimal cutoff value of 32.0° (area under the curve, 0.81; 95% confidence interval, 0.68-0.95; P = .002) and preoperative 3-dimensional echocardiography P3 tethering angle as an independent predictor of recurrence with an optimal cutoff value of 29.9° (area under the curve, 0.92; 95% confidence interval, 0.84-1.00; P < .001). The predictive value of the 3-dimensional geometric multivariate model can be augmented by adding basal aneurysm/dyskinesis (area under the curve, 0.94; 95% confidence interval, 0.87-1.00; P < .001). CONCLUSIONS: Preoperative 3-dimensional echocardiography P3 tethering angle is a stronger predictor of ischemic mitral regurgitation recurrence after annuloplasty than preoperative 2-dimensional echocardiography posterior tethering angle, which is highly influenced by viewing plane. In patients with a preoperative P3 tethering angle of 29.9° or larger (especially when combined with basal aneurysm/dyskinesis), chordal-sparing valve replacement should be strongly considered.


Assuntos
Ecocardiografia Tridimensional , Ecocardiografia , Anuloplastia da Valva Mitral , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Cuidados Pré-Operatórios , Recidiva
14.
Ann Thorac Surg ; 101(2): 567-75; discussion 575, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26688087

RESUMO

BACKGROUND: Valve repair for ischemic mitral regurgitation (IMR) with undersized annuloplasty rings is characterized by high IMR recurrence rates. Patient-specific preoperative imaging-based risk stratification for recurrent IMR would optimize results. We sought to determine if prerepair three-dimensional (3D) echocardiography combined with a novel valve-modeling algorithm would be predictive of IMR recurrence 6 months after repair. METHODS: Intraoperative transesophageal real-time 3D echocardiography was performed in 50 patients undergoing undersized ring annuloplasty for IMR and in 21 patients with normal mitral valves. A customized image analysis protocol was used to assess 3D annular geometry and regional leaflet tethering. IMR recurrence (≥ grade 2) was assessed with two-dimensional transthoracic echocardiography 6 months after repair. RESULTS: Preoperative annular geometry was similar in all IMR patients, and preoperative leaflet tethering was significantly higher in patients with recurrent IMR (n=13) than in patients in whom IMR did not recur (n=37) (tethering index: 3.91 ± 1.01 vs 2.90 ± 1.17, p = 0.008; tethering angles of A3: 23.5° ± 8.9° vs 14.4° ± 11.4°, p = 0.012; P2: 44.4° ± 8.8° vs 28.2° ± 17.0°, p = 0.002; and P3: 35.2° ± 6.0° vs. 18.6° ± 12.7°, p < 0.001). Multivariate logistic regression analysis revealed the preoperative P3 tethering angle as an independent predictor of IMR recurrence with an optimal cutoff value of 29.9° (area under the curve, 0.92; 95% confidence interval, 0.84 to 1.00; p < 0.001). CONCLUSIONS: 3D echocardiography combined with valve modeling is predictive of recurrent IMR. Preoperative regional leaflet tethering of segment P3 is a strong independent predictor of IMR recurrence after undersized ring annuloplasty. In patients with a preoperative P3 tethering angle of 29.9° or larger, chordal-sparing valve replacement rather than valve repair should be strongly considered.


Assuntos
Ecocardiografia Tridimensional/métodos , Ecocardiografia Transesofagiana/métodos , Anuloplastia da Valva Mitral/efeitos adversos , Insuficiência da Valva Mitral/cirurgia , Valva Mitral/diagnóstico por imagem , Isquemia Miocárdica/cirurgia , Cuidados Pré-Operatórios/métodos , Idoso , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Insuficiência da Valva Mitral/complicações , Insuficiência da Valva Mitral/diagnóstico por imagem , Isquemia Miocárdica/complicações , Valor Preditivo dos Testes , Recidiva , Fatores de Tempo
15.
Ann Thorac Surg ; 98(2): 691-4, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25087790

RESUMO

PURPOSE: Advances in mitral valve repair and adoption have been partly attributed to improvements in echocardiographic imaging technology. To educate and guide repair surgery further, we have developed a methodology for fast production of physical models of the valve using novel three-dimensional (3D) echocardiographic imaging software in combination with stereolithographic printing. DESCRIPTION: Quantitative virtual mitral valve shape models were developed from 3D transesophageal echocardiographic images using software based on semiautomated image segmentation and continuous medial representation algorithms. These quantitative virtual shape models were then used as input to a commercially available stereolithographic printer to generate a physical model of the each valve at end systole and end diastole. EVALUATION: Physical models of normal and diseased valves (ischemic mitral regurgitation and myxomatous degeneration) were constructed. There was good correspondence between the virtual shape models and physical models. CONCLUSIONS: It was feasible to create a physical model of mitral valve geometry under normal, ischemic, and myxomatous valve conditions using 3D printing of 3D echocardiographic data. Printed valves have the potential to guide surgical therapy for mitral valve disease.


Assuntos
Ecocardiografia Tridimensional , Valva Mitral/anatomia & histologia , Valva Mitral/diagnóstico por imagem , Modelos Cardiovasculares , Impressão , Neoplasias Cardíacas/diagnóstico por imagem , Neoplasias Cardíacas/patologia , Humanos , Valva Mitral/patologia , Insuficiência da Valva Mitral/patologia , Mixoma/diagnóstico por imagem , Mixoma/patologia
16.
Ann Thorac Surg ; 97(4): 1255-8, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24518577

RESUMO

BACKGROUND: Surgical techniques for aortic valve (AV) repair are directed toward restoring normal structural relationships in the aortic root and rely on detailed assessment of root and valve anatomy. Noninvasive three-dimensional (3D) imaging and modeling may assist in patient selection and operative planning. METHODS: Transesophageal real-time 3D echocardiographic images of 5 patients with normal AVs were acquired. The aortic root and the annulus were manually segmented at end diastole using a 36-point rotational template. The AV leaflets and the coaptation zone were manually segmented in parallel 1-mm cross sections. Quantitative 3D models of the AV and root were generated and used to measure standard anatomic parameters and were compared to conventional two-dimensional echocardiographic measurements. All measurements are given as mean±SD. RESULTS: Annular, sinus, and sinotubular junction areas were 4.1±0.6 cm2, 7.5±1.2 cm2, and 3.9±1.0 cm2, respectively. Root diameters (measured in three locations) by 3D model inspection and two-dimensional echocardiography measurement correlated (R2=0.75). Noncoapted areas of the left, right, and noncoronary leaflets were 1.9±0.2 cm2, 1.6±0.3 cm2, and 1.6±0.3 cm2, respectively. Mean coaptation areas for the left-right, left-noncoronary, and right-noncoronary coaptation zones were 87.7±36.9 mm2, 69.9±20.7 mm2, and 114.2±23.0 mm2, respectively. The mean ratio of noncoapted leaflet area to annular area was 1.3±0.2. CONCLUSIONS: High-resolution 3D models of the in vivo normal human aortic root and valve were generated using 3D echocardiography. Quantitative 3D models and analysis may assist in characterization of pathology and decision making for AV repair.


Assuntos
Valva Aórtica/diagnóstico por imagem , Ecocardiografia Tridimensional , Modelos Cardiovasculares , Estudos de Viabilidade , Humanos , Fatores de Tempo
18.
Ann Thorac Surg ; 95(6): e163-5, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23706472

RESUMO

A significant fraction of patients who survive repair of a DeBakey type I aortic dissection will require a secondary intervention to address ongoing aortic remodeling. Strategic treatment of this population mandates that the technical feasibility of secondary operations be considered at the index procedure. We evaluated a hybrid-based modification of a widely accepted surgical approach that obviates the need for advanced perfusion management techniques and facilitates secondary endografting. Hybrid technology allows for the physiologic equivalent of a total arch replacement without the operative complexity associated with a traditional approach while allowing for strategic planning if a secondary operation is warranted.


Assuntos
Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/cirurgia , Dissecção Aórtica/diagnóstico por imagem , Dissecção Aórtica/cirurgia , Imageamento Tridimensional , Idoso , Aorta Torácica/diagnóstico por imagem , Bioprótese , Implante de Prótese Vascular/métodos , Terapia Combinada , Seguimentos , Humanos , Masculino , Desenho de Prótese , Radiografia , Procedimentos de Cirurgia Plástica/métodos , Reoperação/métodos , Medição de Risco , Índice de Gravidade de Doença , Resultado do Tratamento , Grau de Desobstrução Vascular/fisiologia , Procedimentos Cirúrgicos Vasculares/métodos
19.
Ann Thorac Surg ; 95(2): 614-9, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23245440

RESUMO

BACKGROUND: The effect of aortic valve replacement on three-dimensional mitral annular geometry has not been well described. Emerging transcatheter approaches for aortic valve replacement employ fundamentally different mechanical techniques for achieving fixation and seal of the prosthetic valve than standard surgical aortic valve replacement. This study compares the immediate impact of transcatheter aortic valve replacement (TAVR) and standard surgical aortic valve replacement (AVR) on mitral annular anatomy. METHODS: Real-time three-dimensional echocardiography was performed in patients undergoing TAVR using the Edwards Sapien valve (n = 10 [Edwards Lifesciences, Irvine, CA]) or AVR (n = 10) for severe aortic stenosis. Mitral annular geometric indexes were measured using Tomtec EchoView (Tomtec Imaging Systems, Munich, Germany) to assess regional and global annular geometry. RESULTS: Mixed between-within analysis of variance showed no differences between TAVR and AVR groups in any of the mitral annular geometric indices preoperatively. However, postoperative analysis did demonstrate an effect of AVR on geometry. Patients undergoing open AVR had significant decrease in annular height, septolateral diameter, mitral valve transverse diameter, and mitral annular area after valve replacement (p ≤ 0.006). Similar changes were not noted in the TAVR group. CONCLUSIONS: Mitral annular geometry is better preserved by TAVR than by AVR. Thus, TAVR may be a more physiologic approach to aortic replacement.


Assuntos
Valva Aórtica/cirurgia , Cateterismo Cardíaco , Implante de Prótese de Valva Cardíaca/métodos , Valva Mitral/anatomia & histologia , Valva Mitral/diagnóstico por imagem , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Ultrassonografia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA