Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Front Surg ; 11: 1383401, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38817945

RESUMO

Background: In recent years, 3D printing technology has made significant strides in the medical field. With the advancement of orthopedics, there is an increasing pursuit of high surgical quality and optimal functional recovery. 3D printing enables the creation of precise physical models of fractures, and customized personalized steel plates can better realign and more comprehensively and securely fix fractures. These technologies improve preoperative diagnosis, simulation, and planning for complex limb fractures, providing patients with better treatment options. Patients and methods: Five typical cases were selected from a pool of numerous patients treated with 3D printing technology combined with personalized custom steel plates at our hospital. These cases were chosen to demonstrate the entire process of printing 3D models and customizing individualized steel plates, including details of the patients' surgeries and treatment procedures. Literature reviews were conducted, with a focus on highlighting the application of 3D printing technology combined with personalized custom steel plates in the treatment of complex limb fractures. Results: 3D printing technology can produce accurate physical models of fractures, and personalized custom plates can achieve better fracture realignment and more comprehensive and robust fixation. These technologies provide patients with better treatment options. Conclusion: The use of 3D printing models and personalized custom steel plates can improve preoperative diagnosis, simulation, and planning for complex limb fractures, realizing personalized medicine. This approach helps reduce surgical time, minimize trauma, enhance treatment outcomes, and improve patient functional recovery.

2.
PLoS One ; 19(5): e0302839, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38696506

RESUMO

PURPOSES: Fractures of the inferior patellar pole, unlike other patellar fractures, present challenges for traditional surgical fixation methods. This article introduces the clinical technique and outcomes of using Kirschner wire tension band combined with anchor screw cross-stitch fixation for comminuted inferior patellar pole fractures. METHODS: This retrospective case series study included 14 patients with comminuted inferior patellar pole fractures treated at our institution from September 1, 2020, to April 30, 2022. All patients underwent surgery using the Kirschner wire tension band with anchor screw cross-stitch technique. Follow-up assessments involved postoperative X-rays to evaluate fracture healing, as well as clinical parameters such as healing time, Visual Analog Scale (VAS) scores, range of motion (ROM), and Bostman scores. RESULTS: All patients were followed for an average of over 12 months, with no cases of internal fixation failure. Knee joint stability and function were excellent. X-rays revealed an average healing time of approximately 10.79 ± 1.53 weeks, hospitalization lasted 5.64 ± 1.15 days, surgery took approximately 37.86 ± 5.32 minutes, and intraoperative blood loss was 33.29 ± 8.15 ml. One patient experienced irritation from the internal fixation material. At the final follow-up, the Bostman score averaged 28.29 ± 0.83, knee joint flexion reached 131.07° ± 4.88°, all patients achieved full knee extension, and the VAS score was 0.36 ± 0.63. CONCLUSION: Kirschner wire tension band with anchor screw cross-stitch fixation for comminuted inferior patellar pole fractures delivered satisfactory clinical outcomes. This surgical method, characterized by its simplicity and reliability, is a valuable addition to clinical practice.


Assuntos
Fios Ortopédicos , Fixação Interna de Fraturas , Fraturas Cominutivas , Patela , Humanos , Masculino , Feminino , Adulto , Patela/cirurgia , Patela/lesões , Fraturas Cominutivas/cirurgia , Fixação Interna de Fraturas/métodos , Fixação Interna de Fraturas/instrumentação , Estudos Retrospectivos , Pessoa de Meia-Idade , Amplitude de Movimento Articular , Resultado do Tratamento , Fraturas Ósseas/cirurgia , Consolidação da Fratura , Articulação do Joelho/cirurgia , Articulação do Joelho/fisiopatologia , Adulto Jovem , Parafusos Ósseos , Âncoras de Sutura
3.
BMC Surg ; 24(1): 157, 2024 May 16.
Artigo em Inglês | MEDLINE | ID: mdl-38755649

RESUMO

BACKGROUND: Fractures involving the posterior acetabulum with its rich vascular and neural supply present challenges in trauma orthopedics. This study evaluates the effectiveness of 3D printing technology with the use of custom-made metal plates in the treatment of posterior wall and column acetabular fractures. METHODS: A retrospective analysis included 31 patients undergoing surgical fixation for posterior wall and column fractures of the acetabulum (16 in the 3D printing group, utilizing 3D printing for a 1:1 pelvic model and custom-made plates based on preoperative simulation; 15 in the traditional group, using conventional methods). Surgical and instrument operation times, intraoperative fluoroscopy frequency, intraoperative blood loss, fracture reduction quality, fracture healing time, preoperative and 12-month postoperative pain scores (Numeric Rating Scale, NRS), hip joint function at 6 and 12 months (Harris scores), and complications were compared. RESULTS: The surgical and instrument operation times were significantly shorter in the 3D printing group (p < 0.001). The 3D printing group exhibited significantly lower intraoperative fluoroscopy frequency and blood loss (p = 0.001 and p < 0.001, respectively). No significant differences were observed between the two groups in terms of fracture reduction quality, fracture healing time, preoperative pain scores (NRS scores), and 6-month hip joint function (Harris scores) (p > 0.05). However, at 12 months, hip joint function and pain scores were significantly better in the 3D printing group (p < 0.05). Although the incidence of complications was lower in the 3D printing group (18.8% vs. 33.3%), the difference did not reach statistical significance (p = 0.433). CONCLUSION: Combining 3D printing with individualized custom-made metal plates for acetabular posterior wall and column fractures reduces surgery and instrument time, minimizes intraoperative procedures and blood loss, enhancing long-term hip joint function recovery. CLINICAL TRIAL REGISTRATION: 12/04/2023;Trial Registration No. ChiCTR2300070438; http://www.chictr.org.cn .


Assuntos
Acetábulo , Placas Ósseas , Fixação Interna de Fraturas , Fraturas Ósseas , Impressão Tridimensional , Humanos , Estudos Retrospectivos , Acetábulo/cirurgia , Acetábulo/lesões , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Fixação Interna de Fraturas/métodos , Fixação Interna de Fraturas/instrumentação , Resultado do Tratamento , Fraturas Ósseas/cirurgia , Duração da Cirurgia , Adulto Jovem , Desenho de Prótese , Idoso
4.
J Orthop Surg Res ; 18(1): 669, 2023 Sep 09.
Artigo em Inglês | MEDLINE | ID: mdl-37689739

RESUMO

BACKGROUND: ue to the lack of consensus on the optimal surgical treatment for distal radius fractures (DRF) in elderly patients over 65 years old, the purpose of this study was to compare the efficacy of external fixation (EF) with Kirschner wires and volar locking plate (VLP) in the treatment of DRF through a retrospective cohort study. We hypothesized that there would be no significant difference in overall complications and functional recovery between the two methods. METHODS: We retrospectively analyzed 62 patients over 65 years old who underwent surgical treatment for C-type DRF between 2019 and 2022. Based on the different treatment methods, they were divided into the EF group and the VLP group. General data, inpatient data, and postoperative complications during follow-up were recorded. The X-ray images before surgery, after surgery, and at the last follow-up were analyzed, and the results of wrist motion range, Gartland-Werley wrist joint score, and DASH score were evaluated 6 months after surgery for both groups. RESULT: Thirty patients underwent closed reduction and external fixation combined with Kirschner wire fixation, while 32 underwent open reduction and VLP fixation. The EF group had significantly shorter operation time, intraoperative blood loss, injury-to-surgery time, and hospital stay compared to the VLP group (all p < 0.001). At the last follow-up, the radiographic parameters (ulnar variance and radial inclination) and wrist joint function (wrist dorsiflexion and forearm supination) were better in the VLP group than in the EF group (p = 0.04, p = 0.01, p = 0.001, p = 0.02, respectively). However, there was no significant difference in overall Gartland-Werley wrist joint score, DASH score, and incidence of postoperative complications between the two groups (p = 0.31, p = 0.25, p = 0.47, respectively). CONCLUSION: For patients aged 65 and above with distal radius fractures (DRF) of type C, VLP and external fixation with Kirschner wires yield comparable functional outcome and complications rate at the short term. However, VLP allowed restoration of better radiological parameters.


Assuntos
Fios Ortopédicos , Fraturas do Punho , Idoso , Humanos , Estudos Retrospectivos , Fixadores Externos , Fixação de Fratura , Complicações Pós-Operatórias
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA