Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Ann Palliat Med ; 10(4): 4716-4720, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33966420

RESUMO

BACKGROUND: Intraocular lenses are widely used in the treatment of cataract patients, but currently clinical, procedural and product information is incomplete in many hospitals and there is an urgent need for a database to improve surgical safety, and outcomes. METHODS: Data on the brand and specifications of the intraocular lens, and the postoperative outcome of cataract patients after intraocular lens implantation from January 2017 to June 2018 were collected to create an intraocular lens database as an online public platform. RESULTS: A total of 96 cataract patients were divided into groups A and B based on preoperative corrected visual acuity. At 3 months after surgery the visual acuity of patients in group A recovered from 1.51±0.19 to 0.76±0.18, and the in group B it recovered from 1.02±0.27 to 0.49±0.13. Overall, the postoperative visual acuity of all patients improved significantly (P<0.001). We also used the NEI-VFQ-25 visual function questionnaire to evaluate the visual function of the patients before and after surgery. At 3 months after surgery, the mean score of patients in group A increased from 21.89±14.21 to 59.97±18.29 and in group B it increased from 38.26±17.57 to 70.28±12.37. Overall, the patients' postoperative scores increased significantly (P<0.001). CONCLUSIONS: Cataract phacoemulsification and intraocular lens implantation can effectively and safely restore and improve the visual function of cataract patients. Information sharing through establishment of an intraocular lens information database will assist in further advances and consistency in the treatment of cataract patients.


Assuntos
Extração de Catarata , Catarata , Lentes Intraoculares , Facoemulsificação , Humanos , Implante de Lente Intraocular
2.
Langmuir ; 31(13): 3840-6, 2015 Apr 07.
Artigo em Inglês | MEDLINE | ID: mdl-25730308

RESUMO

The electrowetting dynamics of a water drop on a stainless steel surface in air is investigated under ultralow voltages. The spreading behavior can be classified into three regimes. The drop expands slowly in regime I, but the spreading accelerates quite rapidly in regime II. The spreading becomes insignificant in regime III. The experimental results are compared to the equilibrium shapes acquired by Surface Evolver simulations. The good agreement between them indicates that the slow electrowetting dynamics can be considered to be a quasi-equilibrium process. The influences of the electric field and drop size on the spreading dynamics are examined. The variation of both the contact angle and base diameter with time in regimes II and III can be well described by the exponential change with a characteristic time, which grows with the drop volume but is inversely proportional to the electric field. A simple model based on the electromechnical mechanism is proposed to explain the spreading dynamics. The exponential change is attributed to ion migration from the bulk of the drop to the contact line. The experimental results agree well with the prediction of our simple theory.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA