Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Adv Mater ; : e2406474, 2024 Jul 26.
Artigo em Inglês | MEDLINE | ID: mdl-39054931

RESUMO

One-for-all phototheranostics based on a single molecule is recognized as a convenient approach for cancer treatment, whose efficacy relies on precise lesion localization through multimodal imaging, coupled with the efficient exertion of phototherapy. To unleash the full potential of phototheranostics, advancement in both phototheranostic agents and light delivery methods is essential. Herein, an integrated strategy combining a versatile molecule featuring aggregation-induced emission, namely tBuTTBD, with a modified optical fiber to realize comprehensive tumor diagnosis and "inside-out" irradiation in the orthotopic breast tumor, is proposed for the first time. Attributed to the intense donor-acceptor interaction, highly distorted conformation, abundant molecular rotors, and loose intermolecular packing upon aggregation, tBuTTBD can synchronously undergo second near-infrared (NIR-II) fluorescence emission, photothermal and photodynamic generation under laser irradiation, contributing to a trimodal NIR-II fluorescence-photoacoustic (PA)-photothermal imaging-guided phototherapy. The tumor treatment is further carried out following the insertion of a modified optical fiber, which is fabricated by splicing a flat-end fiber with an air-core fiber. This configuration aims to enable effective in situ phototherapy by maximizing energy utilization for therapeutic benefits. This work not only enriches the palette of NIR-II phototheranostic agents but also provides valuable insight for exploring an integrated phototheranostic protocol for practical cancer treatment.

2.
Talanta ; 259: 124520, 2023 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-37058943

RESUMO

Glutathione (GSH) is present in almost every cell in the body and plays various integral roles in many biological processes. The Golgi apparatus is a eukaryotic organelle for the biosynthesis, intracellular distribution, and secretion of various macromolecules; however, the mechanism of GSH in the Golgi apparatus has not been fully elucidated. Here, specific and sensitive sulfur-nitrogen co-doped carbon dots (SNCDs) with orange-red fluorescence was synthesized for the detection of GSH in the Golgi apparatus. The SNCDs have a Stokes shift of 147 nm and excellent fluorescence stability, and they exhibited excellent selectivity and high sensitivity to GSH. The linear response of the SNCDs to GSH was in the range of 10-460 µM (LOD = 0.25 µΜ). More importantly, we used SNCDs with excellent optical properties and low cytotoxicity as probes, and successfully realized golgi imaging in HeLa cells and GSH detection at the same time.


Assuntos
Corantes Fluorescentes , Pontos Quânticos , Humanos , Células HeLa , Corantes Fluorescentes/toxicidade , Pontos Quânticos/toxicidade , Carbono/toxicidade , Glutationa , Complexo de Golgi , Nitrogênio , Limite de Detecção
3.
Biosensors (Basel) ; 14(1)2023 Dec 28.
Artigo em Inglês | MEDLINE | ID: mdl-38248392

RESUMO

Fiber-optic biosensors have garnered significant attention and witnessed rapid development in recent years owing to their remarkable attributes such as high sensitivity, immunity to electromagnetic interference, and real-time monitoring. They have emerged as a potential tool in the realm of biomarker detection for low-concentration and small molecules. In this paper, a portable and cost-effective optical fiber biosensor based on surface plasmon resonance for the early detection of breast cancer is demonstrated. By utilizing the aptamer human epidermal growth factor receptor 2 (HER2) as a specific biomarker for breast cancer, the presence of the HER2 protein can be detected through an antigen-antibody binding technique. The detection method was accomplished by modifying a layer of HER2 aptamer on the flat surface of a gold-coated D-shaped polymer optical fiber (core/cladding diameter 120/490 µm), of which the residual thickness after side-polishing was about 245 µm, the thickness of the coated gold layer was 50 nm, and the initial wavelength in pure water was around 1200 nm. For low-concentration detection of the HER2 protein, the device exhibited a wavelength shift of ~1.37 nm with a concentration of 1 µg/mL (e.g., 5.5 nM), which corresponded to a limit of detection of ~5.28 nM. Notably, the response time of the biosensor was measured to be as fast as 5 s. The proposed biosensor exhibits the potential for early detection of HER2 protein in initial cancer serum and offers a pathway to early prevention of breast cancer.


Assuntos
Neoplasias , Ressonância de Plasmônio de Superfície , Humanos , Fibras Ópticas , Tecnologia de Fibra Óptica , Ouro , Oligonucleotídeos , Polímeros
4.
ACS Appl Mater Interfaces ; 14(10): 12359-12366, 2022 Mar 16.
Artigo em Inglês | MEDLINE | ID: mdl-35175728

RESUMO

In situ measurement of high temperature is critical in aerospace, petrochemical, metallurgical, and power industries. The single-crystal sapphire fiber is a promising material for high-temperature measurement owing to its high melting point of ∼2045 °C. Sapphire fiber Bragg gratings (SFBGs), which could be inscribed in sapphire fibers with a femtosecond laser, are widely used as high-temperature sensors. However, conventional SFBGs typically exhibit a significant deterioration in their spectra after long-term operation at ultra-high temperatures, resulting from the formation of some unwanted microstructural features, that is, lossy spots and micro-etched lines, on the surface of the sapphire fiber. Here, we report for the first time, to the best of our knowledge, a thermally stabilized ultra-high-temperature sensor based on an SFBG created by femtosecond laser inscription, inert gas-sealed packaging, and gradient temperature-elevated annealing. The results indicate that the lossy spots are essentially aluminum hydroxide induced by high-temperature oxidation, and the inert gas-sealed packaging process can effectively insulate the sapphire fiber from the ambient air. Moreover, the formation of micro-etched lines was suppressed successfully by using the gradient temperature-elevated annealing process. As a result, the surface topography of the SFBG after operating at high temperatures was improved obviously. The long-term thermal stability of such an SFBG was greatly enhanced, showing a stable operation at 1600 °C for up to 20 h. In addition, it could withstand an even higher temperature of 1800 °C with a sensitivity of 41.2 pm/°C. The aforementioned results make it promising for high-temperature sensing in chemical, aviation, smelting, and power industries.

5.
Opt Lett ; 47(4): 758-761, 2022 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-35167518

RESUMO

A multicore fiber Bragg grating (MC-FBG) array shape sensor is a powerful tool for a variety of applications. However, the efficient fabrication of high-quality MC-FBG arrays remains a problem. Here, we report for the first time, to the best of our knowledge, a new method of directly writing FBG arrays in a seven-core fiber (SCF) through the protective coating using femtosecond laser auto-positioning point-by-point technology, which is accomplished by image recognition and micro-displacement compensation. An MC-FBG array consisting of 140 individual FBGs with a grating length of 2 mm was successfully inscribed into seven cores of a 440 mm-long SCF. Each core contained 20 wavelength-division-multiplexed (WDM) FBGs with wavelengths ranging from 1522.11 nm to 1579.28 nm. In other words, the MC-FBG array consisted of 20 WDM nodes with an interval of 2 cm along the fiber, and each node contained seven identical FBGs integrated in parallel into the fiber cross-section. Moreover, the fabricated MC-FBG array exhibited a strong orientation dependence in bend sensing, with a maximum sensitivity of 55.49 pm/m-1. Subsequently, 2D and 3D shape sensing were demonstrated using the fabricated MC-FBG array, with maximum reconstruction errors per unit length of 4.51% and 10.81%, respectively. Hence, the MC-FBG arrays fabricated using the proposed method are useful in many applications, such as posture monitoring, smart robotics, and minimally invasive surgery.

6.
Opt Lett ; 45(16): 4571-4574, 2020 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-32797012

RESUMO

A non-diaphragm fiber gas pressure sensor based on a multimode interferometer (MI) using a hollow-core tube lattice fiber (HC-TLF) as a gas cell is proposed and experimentally demonstrated. The sensor is fabricated by fusion splicing a sandwich structure of a graded-index multimode fiber, HC-TLF, and lead-in/out single mode fiber. Several side-holes are drilled by using a femtosecond laser on the side wall of the HC-TLF to allow gas in and out of the fiber. The positions of side-hole in HC-TLF have been investigated during the experiments, which indicate that the highest gas pressure sensitivity existed as the side-hole located in the gap between adjacent cladding holes of the HC-TLF. The proposed structure exhibits a high sensitivity of 8.1 nm/MPa with the average gas fill time of 2.2 s. This sensor also has low temperature sensitivity and low temperature cross sensitivity of 12.3 pm/°C and 1.5 kPa/°C as the temperature rises to 400°C. In addition, the advantages of the gas pressure sensor, such as small size, rapid response, low temperature cross sensitivity, and simple fabrication process, make it suitable for high-pressure measurement in harsh conditions, e.g., downhole and ocean bottom.

7.
Nano Lett ; 20(9): 6473-6480, 2020 Sep 09.
Artigo em Inglês | MEDLINE | ID: mdl-32786928

RESUMO

Detection of individual molecules is the ultimate goal of any chemical sensor. In the case of gas detection, such resolution has been achieved in advanced nanoscale electronic solid-state sensors, but it has not been possible so far in integrated photonic devices, where the weak light-molecule interaction is typically hidden by noise. Here, we demonstrate a scheme to generate ultrasensitive down-conversion four-wave-mixing (FWM) in a graphene bipolar-junction-transistor heterogeneous D-shaped fiber. In the communication band, the FWM conversion efficiency can change steeply when the graphene Fermi level approaches 0.4 eV. In this condition, we exploit our unique two-step optoelectronic heterodyne detection scheme, and we achieve real-time individual gas molecule detection in vacuum. Such combination of graphene strong nonlinearities, electrical tunability, and all-fiber integration paves the way toward the design of versatile high-performance graphene photonic devices.

8.
ACS Appl Mater Interfaces ; 12(29): 33163-33172, 2020 Jul 22.
Artigo em Inglês | MEDLINE | ID: mdl-32496752

RESUMO

Hydrogen as an antioxidant gas has been widely used in the medical and biological fields for preventing cancer or treating inflammation. However, controlling the hydrogen concentration is crucial for practical use due to its explosive property when its volume concentration in air reaches the explosive limit (4%). In this work, a polymer-based microcantilever (µ-cantilever) hydrogen sensor located at the end of a fiber tip is proposed to detect the hydrogen concentration in medical and biological applications. The proposed sensor was developed using femtosecond laser-induced two-photon polymerization (TPP) to print the polymer µ-cantilever and magnetron sputtering to coat a palladium (Pd) film on the upper surface of the µ-cantilever. Such a device exhibits a high sensitivity, roughly -2 nm %-1 when the hydrogen concentration rises from 0% to 4.5% (v/v) and a short response time, around 13.5 s at 4% (v/v), making it suitable for medical and environmental applications. In addition to providing an ultracompact optical solution for fast and highly sensitive hydrogen measurement, the polymer µ-cantilever fiber sensor can be used for diverse medical and biological sensing applications by replacing Pd with other functional materials.


Assuntos
Hidrogênio/análise , Fibras Ópticas , Polímeros/química , Lasers , Paládio/química , Tamanho da Partícula , Propriedades de Superfície
9.
Opt Lett ; 43(13): 3017-3020, 2018 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-29957770

RESUMO

A diaphragm-free probe-type gas-pressure sensor is proposed and experimentally demonstrated based on a hollow-core photonic bandgap fiber (HC-PBF) with a quartz capillary. The section of the HC-PBF acts as a Fabry-Perot cavity, and the quartz capillary acts as a microfluidic channel for a gas inlet. An inner diameter of the quartz capillary (∼2 µm) smaller than the HC-PBF (∼10.9 µm) ensures a mirror reflection and a microfluidic channel simultaneously. The sensor probe has a minimal size (∼125 µm) and can function at gas pressures as high as 8 MPa. A higher pressure test is limited by our gas-pressure generation devices. Excellent stability of the sensor is observed in a long timescale, and repeatability of the sensor is confirmed by tests of six different samples. Compared with conventional optical fiber gas-pressure sensors, the proposed sensor involves a simple fabrication process and can acquire probe measurements with high sensitivity (∼4.17 nm/MPa), excellent linearity (0.9999), fast response, and no hysteresis. The proposed sensor can also function at temperatures as high as 800°C, which is beneficial for high pressure measurements in extreme conditions. Moreover, the fast response of the sensor is attractive for dynamic pressure measurements, which needs further study and characterization.

10.
Genes (Basel) ; 9(3)2018 Mar 13.
Artigo em Inglês | MEDLINE | ID: mdl-29534013

RESUMO

Cancer is a serious health issue worldwide. Traditional treatment methods focus on killing cancer cells by using anticancer drugs or radiation therapy, but the cost of these methods is quite high, and in addition there are side effects. With the discovery of anticancer peptides, great progress has been made in cancer treatment. For the purpose of prompting the application of anticancer peptides in cancer treatment, it is necessary to use computational methods to identify anticancer peptides (ACPs). In this paper, we propose a sequence-based model for identifying ACPs (SAP). In our proposed SAP, the peptide is represented by 400D features or 400D features with g-gap dipeptide features, and then the unrelated features are pruned using the maximum relevance-maximum distance method. The experimental results demonstrate that our model performs better than some existing methods. Furthermore, our model has also been extended to other classifiers, and the performance is stable compared with some state-of-the-art works.

11.
Lab Chip ; 18(4): 595-600, 2018 02 13.
Artigo em Inglês | MEDLINE | ID: mdl-29359230

RESUMO

Discriminating edible oils from gutter oils has significance in food safety, as illegal gutter oils cannot meet a variety of criteria such as the acid value, peroxide value and quality. To discriminate these illegal cooking oils, we propose an ultrasensitive optofluidic detection method based on a hybrid-waveguide coupler. Prior to the straight waveguide inscription in the cladding of the silica tube using a femtosecond laser, a section of coreless fibre is firstly spliced with the ST to supply a platform for the inscription of an S-band waveguide. Then a pair of microfluidic channels are ablated on the ST using the fs laser to enable liquid analytes to flow in and out of the air channel. In the transmission spectrum, a unique resonant loss dip can be observed, which is produced by coupling the light from the laser inscribed waveguide to the liquid core when the phase-matching condition is met. This hybrid-waveguide coupler with a simplified structure realizes dynamic optofluidic refractive index sensing with an ultrahigh sensitivity of -112 743 nm RIU-1, a detection limit of 2.08 × 10-5 RIU and a refractive index detection range from 1.4591 to 1.4622. This novel method can be used for food safety detection, specifically, for the discrimination of gutter oils.

12.
Opt Express ; 25(15): 17105-17113, 2017 Jul 24.
Artigo em Inglês | MEDLINE | ID: mdl-28789206

RESUMO

We propose and experimentally verify an innovative label-free optical fiber biosensor based on a Mach-Zehnder interferometer for bovine serum albumin (BSA) concentration detection. The proposed fiber biosensor utilized a micro-cavity within a single-mode fiber to induce Mach-Zehnder interference. A remarkable feature of this biosensor is that external media can directly interact with the fiber core signal through microfluidic channels connected to the micro-cavity and sensor surface. The device was fabricated by means of femtosecond laser micromachining and chemical etching. A fiber interferometer of this type exhibits an ultrahigh refractive index sensitivity of -10,055 nm/RIU and a detection limit of 3.5 × 10-5 RIU. Different concentrations of BSA with an infinitesimally small refractive index difference can be clearly differentiated in situ by the interferential spectra of the structure. Experiments demonstrated the biosensor exhibited a BSA solution concentration sensitivity of -38.9 nm/(mg/mL) and a detection limit of 2.57 × 10-4 mg/mL, respectively. Moreover, this biosensor is a sub-microliter dose and ultrasensitive at the low concentrations detected in BSA, which make it a promising for biochemical applications such as DNA hybridization, cancer screenings, medicine examination and environmental engineering, etc.


Assuntos
Técnicas Biossensoriais/instrumentação , Interferometria/instrumentação , Microtecnologia , Soroalbumina Bovina/análise , Lasers , Limite de Detecção , Fibras Ópticas , Refratometria
13.
Sci Rep ; 7(1): 787, 2017 04 11.
Artigo em Inglês | MEDLINE | ID: mdl-28400570

RESUMO

We demonstrate an ultrahigh-sensitivity gas pressure sensor based on the Fabry-Perot interferometer employing a fiber-tip diaphragm-sealed cavity. The cavity is comprised of a silica capillary and ultrathin silica diaphragm with a thickness of 170 nm, with represents the thinnest silica diaphragm fabricated thus far by an electrical arc discharge technique. The resulting Fabry-Perot interferometer-based gas pressure sensor demonstrates a gas pressure sensitivity of about 12.22 nm/kPa, which is more than two orders of magnitude greater than that of a similarly configured fiber-tip air bubble sensor. Moreover, our gas pressure sensor has a low temperature cross-sensitivity of about 106 Pa/°C, and the sensor functions well up to a temperature of about 1000 °C. As such, the sensor can potentially be employed in high-temperature environments.

14.
Opt Express ; 24(24): 27890-27898, 2016 Nov 28.
Artigo em Inglês | MEDLINE | ID: mdl-27906357

RESUMO

A gas pressure sensor based on an antiresonant reflecting guidance mechanism in a hollow-core fiber (HCF) with an open microchannel is experimentally demonstrated for gas pressure sensing. The microchannel was created on the ring cladding of the HCF by femtosecond laser drilling to provide an air-core pressure equivalent to the external environment. The HCF cladding functions as an antiresonant reflecting waveguide, which induces sharp periodic lossy dips in the transmission spectrum. The proposed sensor exhibits a high pressure sensitivity of 3.592 nm/MPa and a low temperature cross-sensitivity of 7.5 kPa/°C. Theoretical analysis indicates that the observed high gas pressure sensitivity originates from the pressure induced refractive index change of the air in the hollow-core. The good operation durability and fabrication simplicity make the device an attractive candidate for reliable and highly sensitive gas pressure measurement in harsh environments.

15.
Opt Express ; 23(5): 6673-8, 2015 Mar 09.
Artigo em Inglês | MEDLINE | ID: mdl-25836884

RESUMO

A Mach-Zehnder interferometer based on a twin-core fiber was proposed and experimentally demonstrated for gas pressure measurements. The in-line Mach-Zehnder interferometer was fabricated by splicing a short section of twin-core fiber between two single mode fibers. A micro-channel was created to form an interferometer arm by use of a femtosecond laser to drill through one core of the twin-core fiber. The other core of the fiber was remained as the reference arm. Such a Mach-Zehnder interferometer exhibited a high gas pressure sensitivity of -9.6 nm/MPa and a low temperature cross-sensitivity of 4.4 KPa/°C. Moreover, ultra-compact device size and all-fiber configuration make it very suitable for highly-sensitive gas pressure sensing in harsh environments.

16.
Opt Lett ; 40(8): 1791-4, 2015 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-25872075

RESUMO

We demonstrated an inflated long period fiber grating (I-LPFG) inscribed in a pure-silica photonic crystal fiber (PCF) for high-sensitivity gas pressure sensing applications. The I-LPFG was inscribed by use of the pressure-assisted CO2 laser beam-scanning technique to inflate periodically air holes of a PCF along the fiber axis. Such an I-LPFG with periodic inflations exhibits a very high gas pressure sensitivity of 1.68 nm/MPa, which is one order of magnitude higher than that, i.e., 0.12 nm/Mpa, of the LPFG without periodic inflations. Moreover, the I-LPFG has a very low temperature sensitivity of 3.1 pm/°C due to the pure silica material in the PCF so that the pressure measurement error, resulting from the cross-sensitivity between temperature and gas pressure, is less than 1.8 Kpa/°C in the case of no temperature compensation. So the I-LPFG could be used to develop a promising gas pressure sensor, and the achieved pressure measurement range is up to 10 MPa.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA