Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 17 de 17
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-38932596

RESUMO

PURPOSE: The purpose of this study was to assess whether kinematic alignment (KA) outperforms mechanical alignment (MA) in restoring patellar tracking to native patterns by using a clustering algorithm. METHODS: Twenty cadavers (40 knees) were evaluated. For each cadaver, one knee was randomly assigned to KA and the other to MA. KA total knee arthroplasty (TKA) procedures were performed using a caliper-verified technique, while MA TKA procedures utilized a measured resection technique. Subsequently, all specimens were mounted on a customized knee-testing system, and patellar tracking was measured using a motion analysis system. All patellar tracking data were clustered using the density-based spatial clustering of applications with noise algorithm. Differences in patellar tracking patterns and the restoration of native patellar tracking were compared between the two alignment strategies. RESULTS: Patellar tracking patterns following KA were considerably different from MA. Pre- and post-TKA patellar tracking patterns following MA were grouped into separate clusters, whereas a substantial proportion of patellar tracking patterns following KA were grouped into the pre-TKA dominant cluster. Compared to MA, a greater proportion of patellar tracking patterns following KA showed similar patterns to native knees (p < 0.05) and more patellar tracking patterns following KA paired with preoperative patterns (p < 0.01). CONCLUSION: KA restored native patellar tracking patterns more closely compared to MA. LEVEL OF EVIDENCE: Level I, therapeutic study.

2.
Orthop Surg ; 15(9): 2477-2481, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37345451

RESUMO

BACKGROUND: Idiopathic avascular necrosis of the lunate is known as Kienböck's disease and that of the scaphoid is known as Preiser's disease. Because the prevalence of coexisting Kienböck's and Preiser's diseases is very low, standardized stages of disease and treatments are not established. CASE PRESENTATION: We report coexisting avascular necrosis of the scaphoid and lunate in a 68-year-old woman with no history of steroids or other risk factors. We treated her with proximal row carpectomy with capsular interposition technique. A distal-based dorsal capsular flap was prepared and repaired the palmar capsule. At the last follow-up, she had no pain and had gained improved range of wrist motion. There was no arthritic change at the newly formed radiocapitate joint. CONCLUSIONS: In the case of collapsed lunate and scaphoid with avascular necrosis, the proximal row carpectomy procedure has an advantage. Proximal row carpectomy with dorsal capsular interposition can be performed when the lunate or scaphoid cannot be saved. Arthritic changes of the capitate head and distal radius lunate facet can be covered with the dorsal capsule.


Assuntos
Ossos do Carpo , Osso Semilunar , Osteonecrose , Humanos , Feminino , Idoso , Ossos do Carpo/cirurgia , Punho , Articulação do Punho/cirurgia , Osso Semilunar/cirurgia , Osteonecrose/cirurgia
3.
Orthop Surg ; 15(7): 1920-1925, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37254251

RESUMO

BACKGROUND: Treatments for chronic perilunate or lunate dislocations are very difficult and associated with poor prognoses. There is no established treatment method and are still many controversies. CASE PRESENTATION: We reported three cases of chronic neglected lunate volar dislocation treated with a novel surgical technique. All three cases were males with wrist pain and tingling sensation. Radiographs confirmed chronic volar dislocation of the lunate. Open reduction was performed by combined volar and dorsal approaches. After anatomical reduction, scapholunate and lunotriquetral interosseous ligament reconstructions were performed with the palmaris longus tendon and synthetic tape. The patients had an uneventful postoperative period with satisfactory functional outcomes at the last follow-up. CONCLUSIONS: We believe that open reduction and interosseous ligament reconstruction using the autogenous tendon and synthetic tape may be a valuable option for treating chronic volar dislocation of the lunate.


Assuntos
Luxações Articulares , Osso Semilunar , Osso Escafoide , Traumatismos do Punho , Masculino , Humanos , Feminino , Osso Escafoide/cirurgia , Ligamentos Articulares/cirurgia , Osso Semilunar/diagnóstico por imagem , Osso Semilunar/cirurgia , Luxações Articulares/diagnóstico por imagem , Luxações Articulares/cirurgia , Extremidade Superior , Traumatismos do Punho/diagnóstico por imagem , Traumatismos do Punho/cirurgia
4.
Medicine (Baltimore) ; 101(24): e29479, 2022 Jun 17.
Artigo em Inglês | MEDLINE | ID: mdl-35713459

RESUMO

RATIONALE: Pan-carpal dissociation is very rare injury and there is little information as to diagnosis, treatment, and prognosis of this injury. PATIENT CONCERNS: A 35-year-man presented to our hospital with severe pain and swelling of the left wrist and forearm after slipping and falling while riding a motorcycle. DIAGNOSIS: The wrist simple radiographs demonstrated unrecognizable severe fracture-dislocation of the carpal bones concomitant with fractures of the radioulnar shaft. Three-dimensional computed tomography revealed a capitate fracture-dislocation, as well as hamate dislocation, lunotriquetral (LT), and scapholunate (SL) dissociation. These findings suggested pan-carpal dissociation. INTERVENTIONS: To prevent compartment syndrome, fasciotomy, carpal tunnel release, and open reduction and plate fixation for both bone fracture were performed first. Then, for pan-carpal dissociation, the capitate, carpometacarpal joint (CMCJ), and hamate were reduced and fixed first. Then, the SL, LT, and other intercarpal ligaments were repaired. Finally, additional trans-carpal pins to reinforce the ligament repair and 2.0 mm plate to buttress the third CMCJ were fixed. The patient was instructed to begin gentle range of motion exercises of the wrist with pins from four weeks after surgery and all pins were removed at six weeks postoperatively. OUTCOMES: 12 months after the operation, the patient exhibited almost full range of motion with mild pain with VAS (Visual analogue scale) 1-2 at rest and VAS 3-4 with effort. Quick DASH (the disabilities of the arm, shoulder and hand) score was 25 and modified Mayo score was 70. The radiographs demonstrated union of the radioulnar shaft, and the carpal bone alignment was successfully maintained. LESSONS: Pan-carpal dissociation can be diagnosed in patients with capitate fracture-dislocation, hamate dislocation, LT, and SL dissociation. This pattern of injury is very rare and the authors recommend reduction and fixation of the distal carpal row, followed by the proximal row to facilitate an easy approach to the distal carpal row. Although it is very severe injury, rigid anatomical fixation and an early rehabilitation can lead to favorable functional outcomes.


Assuntos
Ossos do Carpo , Fratura-Luxação , Luxações Articulares , Instabilidade Articular , Fraturas do Rádio , Placas Ósseas/efeitos adversos , Ossos do Carpo/cirurgia , Fratura-Luxação/complicações , Fixação Interna de Fraturas/métodos , Humanos , Luxações Articulares/cirurgia , Instabilidade Articular/cirurgia , Dor/complicações , Fraturas do Rádio/cirurgia , Articulação do Punho/cirurgia
5.
Knee Surg Sports Traumatol Arthrosc ; 30(8): 2815-2823, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34312712

RESUMO

PURPOSE: Kinematically aligned total knee arthroplasty (KA TKA) targets restoration of patient-specific alignment and soft tissue laxity. However, whether KA TKA reproduces native soft tissue strain remains unclear. This cadaveric study tested the hypothesis that KA TKA would better restore the quantitative strain and strain distribution of medial collateral ligament (MCL) to the native healthy knee compared to mechanically aligned (MA) TKA. METHODS: Twenty-four fresh-frozen cadaver knees (12 pairs) were mounted on a customized knee squatting simulator to measure MCL strain during flexion. For each pair, one knee was assigned to KA TKA and the other to MA TKA. During KA TKA, the amount of femur and tibia resected was equivalent to implant thickness without MCL release using the calipered measuring technique. MA TKA was performed using conventional measured resection techniques. MCL strain was measured using a video extensometer (Mercury® RT RealTime tracking system, Sobriety s.r.o, Czech Republic). MCL strain and strain distribution during knee flexion were measured, and the measurements compared between native and post-TKA conditions. RESULTS: Mean and peak MCL strain were similar between KA TKA and native knees at all flexion angles (p > 0.1 at all flexion angles) while mean strain at all flexion angles and peak strain at ≥ 60º of MA TKA were approximately twice those of the native knees (p < 0.05 at ≥ 60º of flexion). In addition, greater MCL strain was observed in 4 of 12 regions of interest (ROI) after MA TKA (M1, M2, P1 and P2) compared to the native knee, whereas after KA TKA, MCL strain measurements were similar at all but 1 ROI (P2). CONCLUSIONS: KA TKA restored a more native amount and distribution of MCL strain compared to MA TKA. These findings provide clues for understanding why patients may experience better performance and more normal knee sensations after KA TKA compared to MA TKA. LEVEL OF EVIDENCE: Therapeutic study, Level I.


Assuntos
Artroplastia do Joelho , Ligamentos Colaterais , Prótese do Joelho , Ligamento Colateral Médio do Joelho , Osteoartrite do Joelho , Artroplastia do Joelho/métodos , Fenômenos Biomecânicos , Ligamentos Colaterais/cirurgia , Humanos , Articulação do Joelho/cirurgia , Ligamento Colateral Médio do Joelho/cirurgia , Osteoartrite do Joelho/cirurgia , Amplitude de Movimento Articular
6.
Sci Rep ; 11(1): 22317, 2021 11 16.
Artigo em Inglês | MEDLINE | ID: mdl-34785741

RESUMO

Direct energy deposition (DED) is a newly developed 3D metal printing technique that can be utilized on a porous surface coating of joint implants, however there is still a lack of studies on what advantages DED has over conventional techniques. We conducted a systematic mechanical and biological comparative study of porous coatings prepared using the DED method and other commercially available technologies including titanium plasma spray (TPS), and powder bed fusion (PBF). DED showed higher porosity surface (48.54%) than TPS (21.4%) and PBF (35.91%) with comparable fatigue cycle. At initial cell adhesion, cells on DED and PBF surface appeared to spread well with distinct actin stress fibers through immunofluorescence study. It means that the osteoblasts bind more strongly to the DED and PBF surface. Also, DED surface showed higher cell proliferation (1.27 times higher than TPS and PBF) and osteoblast cell activity (1.28 times higher than PBF) for 2 weeks culture in vitro test. In addition, DED surface showed better bone to implant contact and new bone formation than TPS in in vivo study. DED surface also showed consistently good osseointegration performance throughout the early and late period of osseointegration. Collectively, these results show that the DED coating method is an innovative technology that can be utilized to make cementless joint implants.


Assuntos
Materiais Revestidos Biocompatíveis/química , Implantes Experimentais , Osseointegração , Osteoblastos/metabolismo , Titânio/química , Linhagem Celular Tumoral , Humanos , Porosidade , Propriedades de Superfície
7.
Biomater Res ; 25(1): 29, 2021 Sep 25.
Artigo em Inglês | MEDLINE | ID: mdl-34563260

RESUMO

Bone is a complex structure with unique cellular and molecular process in its formation. Bone tissue regeneration is a well-organized and routine process at the cellular and molecular level in humans through the activation of biochemical pathways and protein expression. Though many forms of biomaterials have been applied for bone tissue regeneration, electrospun nanofibrous scaffolds have attracted more attention among researchers with their physicochemical properties such as tensile strength, porosity, and biocompatibility. When drugs, antibiotics, or functional nanoparticles are taken as additives to the nanofiber, its efficacy towards the application gets increased. Polyphenol is a versatile green/phytochemical small molecule playing a vital role in several biomedical applications, including bone tissue regeneration. When polyphenols are incorporated as additives to the nanofibrous scaffold, their combined properties enhance cell attachment, proliferation, and differentiation in bone tissue defect. The present review describes bone biology encompassing the composition and function of bone tissue cells and exemplifies the series of biological processes associated with bone tissue regeneration. We have highlighted the molecular mechanism of bioactive polyphenols involved in bone tissue regeneration and specified the advantage of electrospun nanofiber as a wound healing scaffold. As the polyphenols contribute to wound healing with their antioxidant and antimicrobial properties, we have compiled a list of polyphenols studied, thus far, for bone tissue regeneration along with their in vitro and in vivo experimental biological results and salient observations. Finally, we have elaborated on the importance of polyphenol-loaded electrospun nanofiber in bone tissue regeneration and discussed the possible challenges and future directions in this field.

8.
J Hand Surg Am ; 45(10): 985.e1-985.e9, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32434732

RESUMO

PURPOSE: Internal bracing (IB) is an augmentation method using high-strength nonabsorbable tape. This study compared scapholunate interosseous ligament (SLIL) repair alone, SLIL repair with IB augmentation (RIBA), and native intact SLIL (NIS) in a biomechanical cadaveric model. METHODS: We used 21 specimens of fresh-frozen wrists in this study (7 matched pairs, SLIL repair-only and SLIL RIBA groups; and 7 independent fresh-frozen wrists, NIS group). In the SLIL RIBA group, augmentation using IB was performed after the repair. The specimens were preloaded and cyclically loaded in tension. Maximum extension and hysteresis were measured in all specimens. The specimens were subsequently tested for load to failure. Failure load (yield point load, mean ultimate load, and load at clinical failure) and linear stiffness were calculated. RESULTS: In cyclic tensile testing, RIBA showed lower maximum extension and lower hysteresis than repair alone. In load to failure testing, the yield point load was statistically higher in the RIBA (59.3 N) group than in the repair-only (30.4 N) group but showed no significant difference compared with the NIS (90.7 N) groups. Moreover, the RIBA (98.5 N) group showed higher and lower mean ultimate loads than the repair-only (37.7 N) and NIS (211.8 N) groups, respectively. Load at clinical failure was higher with RIBA than with repair alone (3-mm extension: 70.0 vs 26.4 N; 4-mm extension: 84.1 vs 33.4 N). Repair alone and RIBA had comparable linear stiffness (38.2 vs 44.1 N/mm). CONCLUSIONS: Although SLIL RIBA did not recreate biomechanical properties equivalent to those of NIS, it demonstrated a significantly higher strength than repair alone. CLINICAL RELEVANCE: Repair with IB augmentation could serve as a novel surgical technique that enhances SLIL direct repair through biomechanical support.


Assuntos
Osso Semilunar , Osso Escafoide , Fenômenos Biomecânicos , Cadáver , Humanos , Ligamentos Articulares/cirurgia , Osso Escafoide/cirurgia , Articulação do Punho
9.
J Knee Surg ; 33(2): 158-166, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30620986

RESUMO

The present study was conducted to evaluate the force distribution in knee joint during daily activities after open-wedge high tibial osteotomy (OWHTO). A three-dimensional proximal tibial finite element model (FEM) was created using Mimics software to evaluate computed tomography (CT) scans of the tibia after OWHTO. The anterior and posterior gaps were 7.0 and 12.1 mm, respectively, and the target opening angle was 12 degrees. The loading ratio of the medial and lateral tibial plateaus was 6:4. To evaluate force distribution in the knee joint during activities of daily living (ADLs) after OWHTO, peak von Mises stresses (PVMSs) were analyzed at the plate and posterolateral edge region of osteotomized tibia. ADLs associated with greater knee flexion (sitting 90 degrees, standing 90 degrees, bending 90 degrees, stepping up stairs 60 degrees, and stepping downstairs 30 and 60 degrees) yielded PVMSs ranging from 195.2 to 221.5 MPa at the posterolateral edge region. In particular, stepping downstairs with knee flexion to 60 degrees produced the highest PVMS (221.5 MPa), greater than the yield strength (100-200 MPa). The highest plate PVMS was greater than 300 MPa during ADLs associated with flexion angles of approximately 90 degrees. However, these values did not exceed the yield stress (760.0 MPa). Conclusively, higher force was generated during higher flexion associated with weight-bearing and stepping downstairs produced a high force (even at lower flexion) on the posterolateral area of the tibial plateau. Therefore, a caution should be exercised when engaging in knee flexion of approximately 90 degrees and stepping downstairs in the early postoperative period when patients follow a weight-bearing rehabilitation protocol. However, this study is based on modeling; further translational studies are needed prior to clinical application.


Assuntos
Articulação do Joelho/cirurgia , Osteoartrite do Joelho/cirurgia , Osteotomia/métodos , Osteotomia/reabilitação , Tíbia/cirurgia , Atividades Cotidianas , Adulto , Idoso , Fenômenos Biomecânicos , Feminino , Análise de Elementos Finitos , Humanos , Imageamento Tridimensional , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/fisiopatologia , Masculino , Pessoa de Meia-Idade , Osteoartrite do Joelho/diagnóstico por imagem , Osteoartrite do Joelho/fisiopatologia , Osteoartrite do Joelho/reabilitação , Período Pós-Operatório , Amplitude de Movimento Articular , Tíbia/diagnóstico por imagem , Tíbia/fisiopatologia , Tomografia Computadorizada por Raios X , Suporte de Carga , Adulto Jovem
10.
Materials (Basel) ; 12(2)2019 Jan 11.
Artigo em Inglês | MEDLINE | ID: mdl-30641962

RESUMO

Peri-implantitis is a common complication following dental implant placement, which may lead to bone loss and fixation failure. With the conventional fixture, it is difficult to perfectly clear-up the infection. To solve this, we have designed a separable fixture of which the top part is replaceable. This study aimed to compare the structural and biomechanical stability of the separable and conventional fixture. A single surgical model corresponding to the first molar in a virtual mandible model and conventional/separable implants were reproduced to compare the biomechanical characteristics of the implants using finite element analysis (FEA). The loading condition was 200N preload in the first step, and 100N (Axial), 100N (15°), and 30N (45°) in the second step. The stress distribution on the cortical bone in the separable implant was lower than the conventional implant. In particular, the Peak von Mises Stress (PVMS) values of the separable implant under lateral load was found to be about twice as low as that of the conventional implant. In this study, we suggest that the separable implant has an equivalent biomechanical stability compared to the conventional implant, is easy to retrieve in the case of peri-implantitis, and has an excellent initial stability after the surgery when used in stage 2.

11.
Arch Orthop Trauma Surg ; 138(7): 911-920, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29546620

RESUMO

INTRODUCTION: Open-wedge high tibial osteotomy (OWHTO) is a well-established surgical option for medial compartment osteoarthritis of the varus knee. The initial strength of the fixation plate is critical for successful correction maintenance and healing of the osteotomy site. This study was conducted to verify if a newly designed anatomical plate (LCfit) improves the stability of both the medial implant and lateral hinge area, as well as to evaluate how the metal block contributes to both medial and lateral stability. MATERIALS AND METHODS: A finite element (FE) tibial model was combined with TomoFix plate, a LCfit plate with and without a metal block. Data analysis was conducted to evaluate the balanced stability, which refers to the enforced lateral stability resulting from redistribution of overall stress. We assessed the balanced stability of the medial implant and lateral hinge area in three cases using the same Sawbones and loads using the tibia FE model. RESULTS: The LCfit plate reduced stress by 23.1% at the lateral hinge compared to the TomoFix plate (TomoFix vs. LCfit: 34.2 ± 23.3 MPa vs. 26.3 ± 17.5 MPa). The LCfit plate with a metal block reduced stress by 40.1% at the medial plate (210.1 ± 64.2 MPa vs. 125.8 ± 65.7 MPa) and by 31.2% (26.3 ± 17.5 MPa vs. 18.1 ± 12.1 MPa) at the lateral hinge area compared to the reduction using the LCfit plate without a metal block. CONCLUSION: The newly designed fixation system for OWHTO balanced the overall stress distribution and reduced stress at the lateral hinge area compared to that using a conventional fixation system. The addition of the metal block showed additional benefits for balanced stability between the medial implant and lateral hinge area. However, this conclusion could only be drawn using the FE model in this study. Therefore, further clinical studies are necessary to reveal the clinical effect of reduced lateral stress on the occurrence of the lateral hinge fracture and the biologic effect of the metal block on the healing of the medial cortex.


Assuntos
Placas Ósseas , Osteotomia/instrumentação , Osteotomia/métodos , Tíbia/cirurgia , Idoso , Desenho de Equipamento , Feminino , Análise de Elementos Finitos , Humanos , Articulação do Joelho/cirurgia , Masculino , Metais , Pessoa de Meia-Idade , Osteoartrite do Joelho/cirurgia , Cicatrização
12.
Lasers Med Sci ; 28(6): 1495-502, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23324954

RESUMO

This study was aimed to evaluate the effects of low-level laser therapy (LLLT) in the treatment of trabecular bone loss induced by skeletal unloading. Twelve mice have taken denervation operation. At 2 weeks after denervation, LLLT (wavelength, 660 nm; energy, 3 J) was applied to the right tibiae of 6 mice (LASER) for 5 days/week over 2 weeks by using a minimally invasive laser needle system (MILNS) which consists of a 100 µm optical fiber in a fine needle (diameter, 130 µm) [corrected]. Structural parameters and histograms of bone mineralization density distribution (BMDD) were obtained before LLLT and at 2 weeks after LLLT. In addition, osteocyte, osteoblast, and osteoclast populations were counted. Two weeks after LLLT, bone volume fraction, trabeculae number, and trabeculae thickness were significantly increased and trabecular separations, trabecular bone pattern factor, and structure model index were significantly decreased in LASER than SHAM (p < 0.05). BMDD in LASER was maintained while that in SHAM was shifted to lower mineralization. Osteocyte and osteoblast populations were significantly increased but osteoclast population was significantly decreased in LASER when compared with those in SHAM (p < 0.05). The results indicate that LLLT with the MILNS may enhance bone quality and bone homeostasis associated with enhancement of bone formation and suppression of bone resorption.


Assuntos
Reabsorção Óssea/radioterapia , Terapia com Luz de Baixa Intensidade/instrumentação , Animais , Densidade Óssea/efeitos da radiação , Reabsorção Óssea/etiologia , Reabsorção Óssea/patologia , Feminino , Elevação dos Membros Posteriores/efeitos adversos , Camundongos , Camundongos Endogâmicos ICR , Agulhas , Fibras Ópticas , Osteoblastos/patologia , Osteoblastos/efeitos da radiação , Osteoclastos/patologia , Osteoclastos/efeitos da radiação , Osteócitos/patologia , Osteócitos/efeitos da radiação
13.
Biomed Mater ; 6(5): 055005, 2011 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21849724

RESUMO

Recently, various types of semi-rigid pedicle screw fixation systems have been developed for the surgical treatment of the lumbar spine. They were introduced to address the adverse issues commonly found in traditional rigid spinal fusion--abnormally large motion at the adjacent level and subsequent degeneration. The semi-rigid system uses more compliant materials (nitinol or polymers) and/or changes in rod design (coiled or twisted rods) as compared to the conventional rigid straight rods made of Ti alloys (E = 114 GPa, υ = 0.32). However, biomechanical studies on the semi-rigid pedicle screw systems were usually limited to linear modeling of the implant and anatomic elements, which may not be capable of reflecting realistic post-operative motions of the spine. In this study, we evaluated the effects of nonlinearity in materials used for semi-rigid pedicle screw fixation systems to evaluate the changes in biomechanical behaviors using finite element analysis. Changes in range of motion (ROM) and center of rotation (COR) were assessed at the operated and adjacent levels. Actual load-displacement results of the semi-rigid rod from mechanical test were carried out to reflect the nonlinearity of the implant. In addition, nonlinear material properties of various spinal ligaments studies were used for the finite element modeling. The post-operative models were constructed by modifying the previously validated intact model of the L1-S1 spine. Eight different post-operative models were made to address the effects of nonlinearity-with a traditional stiffness modulus rod (with linear ligaments, case 1; with nonlinear ligaments, case 5), with a rigid rod (with linear ligaments, case 2; with nonlinear ligaments, case 6), with a soft rod (with linear ligaments, case 3; with nonlinear ligaments, case 7), and with a nonlinear rod (with linear ligaments, case 4; with nonlinear ligaments, case 8). To simulate the load on the lumbar spine in a neutral posture, follower load (400 N) was applied and then the hybrid loading condition was applied to measure the ROM and COR in the sagittal plane. The more the nonlinearity was included in the model the closer the motion behavior of the device was to that of the intact spine. Furthermore, our results showed that the nonlinearity of the semi-rigid rod was a more sensitive factor than the nonlinearity of the spinal ligaments on biomechanical behavior of the lumbar spine after surgery. Therefore, for better understanding of the surgical effectiveness of the spinal device, more realistic material properties such as nonlinearity of the device and anatomic elements should be considered. In particular, the nonlinear properties of the semi-rigid rod were considered more than the nonlinearity of spinal ligaments.


Assuntos
Parafusos Ósseos , Vértebras Lombares/cirurgia , Fusão Vertebral/instrumentação , Fenômenos Biomecânicos , Engenharia Biomédica , Análise de Elementos Finitos , Humanos , Imageamento Tridimensional , Vértebras Lombares/anatomia & histologia , Vértebras Lombares/fisiologia , Modelos Anatômicos , Dinâmica não Linear , Amplitude de Movimento Articular , Rotação
14.
J Arthroplasty ; 26(4): 596-605, 2011 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-20817389

RESUMO

We prospectively evaluated acetabular cup placement in total hip arthroplasty with an imageless computer navigation system or using conventional manual technique. The achieved cup orientation in the manual group had substantially larger variances and greater placement error than the navigation cases. The use of navigation was abandoned in 3 cases because of excessive pelvic tilt and unreliable registration of the pelvis. Computer navigation system helped improve the accuracy of the acetabular cup placement for total hip arthroplasty in this study. The variation between the intraoperative navigation readings and the computed tomographic values suggests that relying on palpation of bony landmarks through drapes and tissue is a limitation of this method. Further, the variation in pelvic tilt has an effect on cup placement that requires further studies.


Assuntos
Artroplastia de Quadril/métodos , Imageamento Tridimensional/métodos , Osteoartrite do Quadril/cirurgia , Cirurgia Assistida por Computador/métodos , Acetábulo/diagnóstico por imagem , Acetábulo/cirurgia , Idoso , Artroplastia de Quadril/efeitos adversos , Mau Alinhamento Ósseo/epidemiologia , Mau Alinhamento Ósseo/prevenção & controle , Feminino , Fluoroscopia , Luxação do Quadril/epidemiologia , Luxação do Quadril/prevenção & controle , Humanos , Imageamento Tridimensional/efeitos adversos , Incidência , Masculino , Pessoa de Meia-Idade , Monitorização Intraoperatória/métodos , Estudos Prospectivos , Cirurgia Assistida por Computador/efeitos adversos , Tomografia Computadorizada por Raios X
15.
J Biomech Eng ; 132(6): 061003, 2010 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-20887028

RESUMO

Much research has been directed at improving the effectiveness of the radiofrequency (RF) ablation of hepatocellular carcinomas. In that point of view, this study was performed to provide comprehensive information of the relation between RF waveforms and thermodynamic response of the tissue with the consideration of four different types of RF waveforms (half-sine, half-square, half-exponential, and damped-sine) to maximize the amount of tumor tissue removed while maintaining the advantages of RF ablation. For the aim of this study, finite element models incorporating results from previous numerical models were used and validated with ex vivo experiments. From analyses of the entire results, we concluded that this study may prove valuable as a first step in providing comprehensive information of the relation between various RF waveforms and thermodynamic responses within the tissue during the RF ablation process. This study may also contribute toward studies to determine an optimum RF waveform capable of maximizing the amount of tumor tissue removed while maintaining the advantages of RF ablation.


Assuntos
Ablação por Cateter/estatística & dados numéricos , Neoplasias Hepáticas/irrigação sanguínea , Neoplasias Hepáticas/terapia , Animais , Fenômenos Biomecânicos , Engenharia Biomédica , Bovinos , Análise de Elementos Finitos , Humanos , Hipertermia Induzida/estatística & dados numéricos , Técnicas In Vitro , Fígado/irrigação sanguínea , Fígado/cirurgia , Neoplasias Hepáticas/fisiopatologia , Modelos Biológicos , Terapia por Radiofrequência , Termodinâmica
16.
Clin Biomech (Bristol, Avon) ; 23(8): 1004-11, 2008 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-18541352

RESUMO

BACKGROUND: Successful hip reconstruction to restore the normal hip biomechanics requires precise placement of implants. Computer assisted navigation in total hip arthroplasty has been proposed to have the potential to help achieve a high accuracy in implant placement. The goal of the study was to evaluate the accuracy of an imageless computer navigation system on cadavers and to validate a non-invasive computed tomography method for post-operative determination of acetabular cup orientation. METHODS: Total hip arthroplasty was performed on seven cadaver hips with the aid of an imageless computer navigation system. The achieved cup orientation were recorded using three methods, (1) intra-operatively using the imageless computer navigation system, (2) post-operatively with direct bone digitization and (3) with a computed tomography based three dimensional model interpreted by three raters. Measurement from the direct bone digitization was taken as the gold standard to evaluate the other two methods. The intra-rater and inter-rater consistency of the computer tomography-model method were assessed by Cronbach's alpha determination. FINDINGS: Compared with the cup orientation obtained from the direct bone digitization, the average difference for anteversion and abduction were 3.3 (3.5) degrees (P=0.045) and 0.6 (3.7) degrees , respectively, for navigation reading. The average differences for computer tomography-model for three raters were 0.5 (2.1) degrees , 0.8 (1.5) degrees and 3.2 (3.3) degrees (P=0.043) for anteversion and 0.4 (1.6) degrees , 0.3 (1.6) degrees and 2.1 (2.7) degrees for abduction. The intra-rater consistency ranged from 0.626 for a novice rater to over 0.97 for experience raters. The inter-rater consistency (including novice and experienced raters) was over 0.90. INTERPRETATION: While the values for cup orientation determined with imageless computer navigation were comparable to those from direct bone and implant digitization, the measurement for anteversion obtained was not as accurate as that for abduction. The proposed computer tomography-model method has an excellent intra-rater consistency for experienced raters, as well as an excellent overall inter-rater consistency. The study confirms that a non-invasive computed tomography based model analysis can be used in clinical practice as a valid method for post-operatively evaluating the orientation of the acetabular component.


Assuntos
Acetábulo/cirurgia , Artroplastia de Quadril , Prótese de Quadril , Cirurgia Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Acetábulo/anatomia & histologia , Idoso , Artroplastia de Quadril/métodos , Artroplastia de Quadril/normas , Cadáver , Simulação por Computador , Feminino , Consolidação da Fratura , Prótese de Quadril/normas , Humanos , Modelos Anatômicos , Cuidados Pós-Operatórios/instrumentação , Cuidados Pós-Operatórios/métodos , Cirurgia Assistida por Computador/instrumentação , Cirurgia Assistida por Computador/normas , Tomografia Computadorizada por Raios X/normas
17.
J Shoulder Elbow Surg ; 16(6): 795-802, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17936028

RESUMO

Repetitive valgus stress of the elbow can result in excessive strain or rupture of the native medial ulnar collateral ligament (MUCL). The flexor-pronator mass (FPM) may be particularly important for elbow valgus stability in overhead-throwing athletes. The aim of this study was to identify the relative contribution of each muscle of the FPM--that is, the flexor carpi ulnaris (FCU), flexor digitorum superficialis (FDS), flexor carpi radialis (FCR), and pronator teres (PT)--and of the extensor-supinator mass, including the extensor carpi ulnaris (ECU), extensor digitorum communis (EDC), extensor carpi radialis longus and brevus, and brachioradialis, to elbow valgus stability at 45 degrees and 90 degrees of elbow flexion angles. Eight fresh-frozen elbow specimens (mean age at death, 73.75 +/- 14.07 years) were tested. With the skin and subcutaneous tissue removed but all muscles left intact, each individual muscle of the FPM and extensor-supinator mass was loaded at 3 levels of force. During loading, strain on the MUCL and the kinematics of the elbow were measured simultaneously. Kinematic measurements were later repeated when the MUCL was fully cut. At 45 degrees and 90 degrees of elbow flexion, individual loading of the FCU, FDS, and FCR caused significant relief to the MUCL whereas the PT produced no significant change. Furthermore, of these flexor muscles, the FCU provided the greatest MUCL relief at both 45 degrees and 90 degrees . In contrast, loading of the ECU at 45 degrees of elbow flexion produced a significant increase in MUCL strain. All FPM muscles caused significant elbow varus movement at both 45 degrees and 90 degrees when loaded individually. At 90 degrees , the FCU created more motion than both the FCR and PT but not the FDS, and the FDS created more motion than the PT. The EDC and ECU created significant valgus movement at 45 degrees and 90 degrees , which became insignificant when the MUCL was transected. Our study suggested that the FCU, FDS, and FCR may function as dynamic stabilizers, with the FCU being the primary stabilizer for elbow valgus stability, incorporating with the MUCL for all tested joint configurations. Our findings also suggest that the ECU and EDC increased MUCL strain and elbow valgus movement at both 45 degrees and 90 degrees .


Assuntos
Articulação do Cotovelo/fisiopatologia , Instabilidade Articular/fisiopatologia , Músculo Esquelético/fisiopatologia , Idoso , Idoso de 80 Anos ou mais , Fenômenos Biomecânicos , Ligamentos Colaterais/lesões , Ligamentos Colaterais/fisiopatologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Movimento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA