Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J Nanosci Nanotechnol ; 16(2): 1396-9, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-27433593

RESUMO

This study examined the effect of the immobilization of the Gly-Arg-Gly-Asp-Ser (GRGDS) peptide on titanium dioxide (TiO2) nanotube via chemical grafting on osteoblast-like cell (MG-63) viability and differentiation. The specimens were divided into two groups; TiO2 nanotubes and GRGDS-immobilized TiO2 nanotubes. The surface characteristics of GRGDS-immobilized TiO2 nanotubes were observed by using X-ray photoelectron spectroscopy (XPS) and a field emission scanning electron microscope (FE-SEM). The morphology of cells on specimens was observed by FE-SEM after 2 hr and 24 hr. The level of cell viability was investigated via a tetrazolium (XTT) assay after 2 and 4 days. Alkaline phosphatase (ALP) activity was evaluated to measure the cell differentiation after 4 and 7 days. The presence of nitrogen up-regulation or C==O carbons con- firmed that TiO2 nanotubes were immobilized with GRGDS peptides. Cell adhesion was enhanced on the GRGDS-immobilized TiO2 nanotubes compared to TiO2 nanotubes. Furthermore, significantly increased cell spreading and proliferation were observed with the cells grown on GRGDS-immobilized TiO2 nanotubes (P < .05). However, there was no significant difference in ALP activity between GRGDS-immobilized TiO2 nanotubes and TiO2 nanotubes. These results suggest that the GRGDS-immobilized TiO2 nanotubes might be effective in improving the osseointegration of dental implants.


Assuntos
Diferenciação Celular/efeitos dos fármacos , Nanotubos/química , Oligopeptídeos , Osteoblastos/metabolismo , Titânio , Linhagem Celular Tumoral , Sobrevivência Celular/efeitos dos fármacos , Humanos , Oligopeptídeos/química , Oligopeptídeos/farmacologia , Osteoblastos/citologia , Titânio/química , Titânio/farmacologia
2.
J Nanosci Nanotechnol ; 15(8): 6164-7, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26369218

RESUMO

Hydroxyapatite (HA) coating on titanium dioxide (TiO2) nanotubular surface has been developed to complement the defects of both TiO2 and HA. A sol-gel processing technique was used to coat HA on TiO2 nanotubular surface. All the titanium discs were blasted with resorbable blast media (RBM). RBM-blasted Ti surface, anodized Ti surface, and sol-gel HA coating on the anodized Ti surface were prepared. The characteristics of samples were observed using scanning electron microscopy and X-ray photoemission spectroscopy. Biologic responses were evaluated with human osteosarcoma MG63 cells in vitro. The top of the TiO2 nanotubes was not completely covered by HA particles when the coating time was less than 60 sec. It was demonstrated the sol-gel derived HA film was well-crystallized and this enhanced biologic responses in early stage cell response.

3.
J Nanosci Nanotechnol ; 13(8): 5807-10, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23882839

RESUMO

In this study, hydroxyapatite (HA) was coated on anodized titanium (Ti) surfaces through radio frequency magnetron sputtering in order to improve biological response of the titanium surface. All the samples were blasted with resorbable blasting media (RBM). RBM-blasted Ti surface, anodized Ti surface, as-sputtered HA coating on the anodized Ti surface, and heat-treated HA coating on the anodized Ti surface were prepared. The samples were characterized using scanning electron microscopy and X-ray photoemission spectroscopy, and biologic responses were evaluated. The top of the TiO2 nanotubes was not closed by HA particles when the coating time is less than 15 minutes. It was demonstrated that the heat-treated HA was well-crystallized and this enhanced the cell attachment of the anodized Ti surface.


Assuntos
Materiais Revestidos Biocompatíveis/química , Durapatita/química , Magnetismo , Nanotecnologia/métodos , Células 3T3 , Animais , Adesão Celular , Meios de Cultura , Microanálise por Sonda Eletrônica/métodos , Camundongos , Nanotubos/química , Osteoblastos/citologia , Propriedades de Superfície , Titânio/química
4.
J Prosthet Dent ; 108(4): 209-13, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23031726

RESUMO

A patient developed contact mucositis after being treated with a titanium nitride implant abutment. Patch testing disclosed a positive reaction to titanium nitride. After removal of the titanium nitride-coated abutment and placement of an uncoated abutment, all signs and symptoms disappeared. This clinical report suggests that titanium nitride-coated abutments may be a potential allergen in some patients.


Assuntos
Materiais Revestidos Biocompatíveis/efeitos adversos , Dente Suporte/efeitos adversos , Ligas Dentárias/efeitos adversos , Dermatite Alérgica de Contato/etiologia , Estomatite/induzido quimicamente , Titânio/efeitos adversos , Idoso , Alérgenos/efeitos adversos , Projeto do Implante Dentário-Pivô , Planejamento de Prótese Dentária , Planejamento de Dentadura , Prótese Parcial Fixa , Feminino , Humanos , Testes do Emplastro
5.
J Adv Prosthodont ; 1(1): 47-55, 2009 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21165255

RESUMO

STATEMENT OF PROBLEM: A few of studies which compared and continuously measured the stability of various surface treated implants in the same individual had been performed. PURPOSE: We aim to find the clinical significance of surface treatments by observing the differences in the stabilization stages of implant stability. MATERIAL AND METHODS: Eight different surface topographies of dental implants were especially designed for the present study. Machined surface implants were used as a control group. 4 nano-treated surface implants (20 nm TiO(2) coating surface, heat-treated 80 nm TiO(2) coating surface, CaP coating surface, heat treated CaP coating surface) and 3 micro-treated surface implants [resorbable blast media (RBM) surface, sandblast and acid-etched (SAE) surface, anodized RBM surface] were used as experiment groups. All 24 implants were placed in 3 adult dogs. Periotest® & ISQ values measured for 8 weeks and all animals were sacrificed at 8 weeks after surgery. Then the histological analyses were done. RESULTS: In PTV, all implants were stabilized except 1 failed implants. In ISQ values, The lowest stability was observed at different times for each individual. The ISQ values were showed increased tendency after 5 weeks in every groups. After 4 to 5 weeks, the values were stabilized. There was no statistical correlation between the ISQ values and PTV. In the histological findings, the bone formation was observed to be adequate in general and no differences among the 8 surface treated implants. CONCLUSIONS: In this study, the difference in the stability of the implants was determined not by the differences in the surface treatment but by the individual specificity.

6.
J Adv Prosthodont ; 1(2): 75-84, 2009 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-21165259

RESUMO

STATEMENT OF PROBLEM: A number of studies about the nano-treated surfaces of implants have been conducting along with micro-treated surfaces of implants. PURPOSE: The purpose of this study was to get information for the clinical use of nano-treated surfaces compared with micro-treated surfaces by measuring removal torque and analyzing histological characteristics after the placement of various surface-treated implants on femurs of dogs. MATERIAL AND METHODS: Machined surface implants were used as a control group. 4 nano-treated surface implants and 3 micro-treated surface implants [resorbable blast media surface (RBM), sandblast and acid-etched surface (SAE), anodized RBM surface] were used as experimental groups. Removal torque values of implants were measured respectively and the histological analyses were conducted on both 4weeks and 8weeks after implant surgery. The surfaces of removed implants after measuring removal torque values were observed by scanning electron microscopy (SEM) at 8 weeks. RESULTS: 1. Removal torque values of the nano-treated groups were lower than those of micro-treated groups. 2. Removal torque values were similar in the anodized RBM surface groups. 3. On the histological views, there was much of bone formation at 8 weeks, but there was no difference between 4 and 8 weeks, and between the types of implant surfaces as well. CONCLUSION: It is suggested that implant topography is more effective in removal torque test than surface chemistry. To get better clinical result, further studies should be fulfilled on the combined effect of surface topography and chemistry for the implant surface treatments.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA