Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 35
Filtrar
1.
Bioengineering (Basel) ; 11(1)2024 Jan 16.
Artigo em Inglês | MEDLINE | ID: mdl-38247960

RESUMO

To examined alkaline phosphatase enzyme (ALP) activity and the effects of incorporating it in the thickener solution of a hydrogen-peroxide-based bleaching gel containing calcium-polyphosphate (CaPP) on the orthophosphate (PO43-) levels, bleaching effectiveness, and enamel microhardness. ALP activity was assessed at different pH levels and H2O2 concentrations, and in H2O- and Tris-based thickeners. Circular dichroism (CD) was used to examine the ALP secondary structure in water-, Tris-, or H2O2-based mediums. The PO43- levels were evaluated in thickeners with and without ALP. Enamel/dentin specimens were allocated into the following groups: control (without bleaching); commercial (Whiteness-HP-Maxx); Exp-H (H2O-based); CaPP-H; ALP-H (CaPP+ALP); Exp-T (Tris-based); CaPP-T; and ALP-T (CaPP+ALP). Color changes (ΔE/ΔE00) and the bleaching index (ΔWID) were calculated, and surface (SMH) and cross-sectional microhardness (CSMH) were assessed. The two-way ANOVA and Tukey's post-hoc tests were used to compare ALP and PO43- levels; generalized linear models were used to examine: ΔE/ΔE00/SMH/CSMH; and Kruskal-Wallis and Dunn's tests were used for ΔWID (α = 5%). The ALP activity was higher at pH 9, lower in H2O2-based mediums, and similar in both thickeners. The CD-spectra indicated denaturation of the enzyme upon contact with H2O2. The PO43- levels were higher after incorporating ALP, and the ΔE/ΔE00/ΔWID were comparable among bleached groups. SMH was lower after bleaching in Exp-H, while CSMH was highest in ALP-T.

2.
Odontology ; 112(3): 729-738, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38148447

RESUMO

AIM: To evaluate the bleaching efficacy and effects on enamel properties of experimental gels with carbamide peroxide (CP; 10%) or hydrogen peroxide (HP; 6%) containing calcium polyphosphate sub-microparticles (CaPPs). METHODS: A total of 216 bovine tooth specimens were divided for microhardness and color analyses (n = 108) and block randomized into nine groups (n = 12): (G1) commercial CP (Whiteness Perfect, FGM; Brazil); (G2) experimental CP; (G3) CP-0.5%CaPPs; (G4) CP-1.5%CaPPs; (G5) commercial HP (Potenza Bianco, PHS; Brazil); (G6) experimental HP; (G7) HP-0.5%CaPPs; (G8) HP-1.5%CaPPs; (G9) artificial saliva. The gels' pH values were determined with a bench pH meter. Color (ΔE, ΔE00, ΔWID) and microhardness variation were evaluated before and after the therapy. Part of the specimens used for microhardness was submitted to the scanning electron microscopy (SEM) (n = 3) and energy-dispersive X-ray spectroscopy EDX (n = 3) analyses. Statistical analyses were performed in the R statistical software (α = 0.05). Linear mixed models for repeated measures in time were used to analyze microhardness and L* values. Generalized linear models were used to analyze the a*, b*, ΔE, ΔE00, and ΔWID, considering a group effect. The EDX data were analyzed using a one-way ANOVA with Tukey's test. RESULTS: The gels' pH remained over 6,0. All gels effectively bleached the specimens and did not differ significantly. When compared to the control group, the hardness was significantly lower in the G1, G2, G6, and G7 groups. The G3, G4, G5, and G8 groups did not differ significantly (p > 0.05). CONCLUSION: The incorporation of CaPPs in low-concentration whitening gels reduces its negative effects on microhardness without interfering with their bleaching efficacy.


Assuntos
Peróxido de Carbamida , Esmalte Dentário , Géis , Peróxido de Hidrogênio , Microscopia Eletrônica de Varredura , Polifosfatos , Clareadores Dentários , Clareamento Dental , Bovinos , Esmalte Dentário/efeitos dos fármacos , Animais , Peróxido de Hidrogênio/química , Clareadores Dentários/farmacologia , Clareadores Dentários/química , Polifosfatos/farmacologia , Polifosfatos/química , Clareamento Dental/métodos , Peróxido de Carbamida/farmacologia , Dureza , Propriedades de Superfície , Espectrometria por Raios X , Técnicas In Vitro , Cor , Peróxidos/farmacologia , Ureia/análogos & derivados , Ureia/farmacologia , Ureia/química , Concentração de Íons de Hidrogênio , Tamanho da Partícula
3.
Pesqui. bras. odontopediatria clín. integr ; 24: e220171, 2024. tab, graf
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1529141

RESUMO

Abstract Objective: To compare the clinical effect of two desensitizing agents used before the application of a bleaching gel based on 35% hydrogen peroxide (HP). Material and Methods: 30 patients were selected, and two desensitizing agents with different mechanisms of action were applied: Fluorine Neutral 2% (FN), which acts by blocking dentinal canaliculi while Potassium Nitrate 5% with 2% Sodium Fluoride (PN/SF) that acts in nerve transmission and blockade. Desensitizers were used before the application of 35% HP. For whitening, three clinical sessions were performed, with an interval of seven days, with three applications of the bleaching gel for 15 minutes, totaling 45 minutes/session. Tooth sensitivity (TS) was assessed with the numerical analog scale, and a spectrophotometer was used to obtain the color variation (ΔE). ΔE were submitted to ANOVA and Tukey test (p<0.05), and TS data were submitted to a two-way ANOVA analysis. Results: For sensitivity experience, the Tukey test indicated differences between PN/SF and the placebo I, but there was no statistically significant difference between FN and the placebo II. The TS was lower when the desensitizing gel was used during the bleaching procedure compared to after treatment, regardless of the desensitizing agents. Conclusion: PN/SF before in-office tooth bleaching can reduce TS intensity, and the use of desensitizing gel before bleaching did not affect the bleaching efficacy.


Assuntos
Humanos , Masculino , Feminino , Adulto , Dessensibilizantes Dentinários/efeitos adversos , Peróxido de Hidrogênio/efeitos adversos , Fluoreto de Sódio/efeitos adversos , Espectrofotômetros , Análise de Variância , Flúor
4.
Braz. j. oral sci ; 23: e240735, 2024. ilus
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1537142

RESUMO

Aim: To assess the opinion of the students on the impact of COVID-19 pandemic on theoretical knowledge and clinical practice in dentistry at the Piracicaba Dental School ­ FOP/UNICAMP. Methods: A questionnaire was applied using the Google Forms platform, containing 20 questions related to the impacts of the pandemic on knowledge, mental health, and clinical and laboratory practice of dentistry. The satisfaction of the students with teaching was also evaluated. A total of 120 questionnaires were analyzed using R software, through tables and graphs of absolute and relative frequencies distribution. Results: COVID-19 affected the lives of 99% students who participated in the study. Due to distance learning resulting from the COVID-19 pandemic, 50% of the students considered locking or dropping out of college. Operative dentistry was the curricular component most affected by distance and lack of clinical practice. Although most students agreed that the workload of practical disciplines was or would be replaced, 95% felt some kind of deficit in clinical and laboratory practice even with the replacement of the workload. In addition, 93.3% of the students were afraid of not becoming a qualified professional due to the deficiencies on theoretical knowledge and clinical practice caused by the pandemic. Conclusions: Students showed dissatisfaction with the deficiency of clinical and laboratory practice resulting from the pandemic in operative dentistry curricular component. They reported fear and insecurity with their future professional lives. The indication of remote classes for dentistry should only be carried out in emergencies because this is an essentially practical course that suffers losses in learning


Assuntos
Humanos , Masculino , Feminino , Adolescente , Adulto , Estudantes de Odontologia , Conhecimentos, Atitudes e Prática em Saúde , Dentística Operatória , COVID-19 , Aprendizagem
5.
Clin Oral Investig ; 27(9): 5275-5285, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37646909

RESUMO

OBJECTIVE: To assessed the physical and chemical properties of human-enamel after treatment with an experimental bleaching gel containing 35%-hydrogen peroxide (HP) and calcium polyphosphate sub-microparticles (CaPP). MATERIALS AND METHODS: Enamel/dentin specimens (4 × 4 × 3 mm) were obtained (n = 120) and allocated to different groups: control (saliva only); experimental (HP35%); commercial (whiteness-HP-Maxx); CaPP0.5% (HP35% + CaPP0.5wt%); CaPP1.5% (HP35% + CaPP1.5wt%). Three sessions were performed. The specimens' color was assessed using a spectrophotometer and the color (ΔE/ΔE00) and bleaching index (ΔWID) determined. The surface roughness and microhardness were assessed with a roughness tester and Knoop indenter. Raman spectroscopy was performed to obtain the ratios between the areas under the 431, 580, and 1070 cm-1 and the 960 cm-1 bands (430:960, 580:960, 1070:960). Kruskal-Wallis and Dunn compared the color, Ra, and SMH data. The Raman data was analyzed with Kruskal-Wallis and Dunn (α = 5%). RESULTS: The ΔE, ΔE00, and ΔWID were similar among the bleached groups (p > 0.05). The roughness was not different between the groups (p > 0.05). After the 3rd session, CaPP0.5% had higher microhardness than the experimental (p < 0.05). The 1070:960 was higher in the experimental than in the CaPP1.5% and control (p < 0.05). CONCLUSIONS: In human enamel, CaPP did not alter the bleaching effectiveness or roughness, and additionally, CaPP-containing gels increased the microhardness and preserved the mineral content when compared to the experimental without CaPP. CLINICAL RELEVANCE: Experimental bleaching gels containing calcium polyphosphate sub-microparticles as a mineral source reduce the mineral content alteration and superficial microhardness reduction, known potential side effects of the in-office bleaching treatments.


Assuntos
Cálcio , Peróxido de Hidrogênio , Humanos , Esmalte Dentário , Géis , Ácido Hipocloroso , Polifosfatos/farmacologia , Hidrogênio
6.
Braz. dent. j ; 34(2): 56-66, Mar.-Apr. 2023. tab, graf
Artigo em Inglês | LILACS-Express | LILACS, BBO - Odontologia | ID: biblio-1439571

RESUMO

Abstract Natrosol and Aristoflex® AVC polymers are widely applied in the cosmetic industry and have recently been applied as a thickener option in the composition of dental bleaching gels, with the purpose to reduce the adverse effects on enamel mineral components. The aim of this study was to evaluate the color variation (ΔE* ab, ΔE00, ∆WID), surface roughness (Ra), and mineral content quantification (Raman Spectroscopy) of dental enamel after bleaching treatment with experimental gel-based on 10% carbamide peroxide (CP), containing Carbopol, Natrosol, and Aristoflex® AVC. Sixty bovine teeth were randomly divided into 6 groups (n=10): Negative Control (NC) - no treatment; Positive Control (PC) - Whiteness Perfect 10% - FGM; CP with Carbopol (CPc); CP with Natrosol (CPn); CP with Aristoflex® AVC (CPa); NCP - no thickener. Data were analyzed, and generalized linear models (∆WID -T0 x T1) were used for repeated measurements in time for Ra and with a study factor for ΔE* ab and ΔE00. For the evaluation of the mineral content, data were submitted to one-way ANOVA and Tukey tests. For enamel topographic surface analysis the Scanning Electron Microscope (SEM) was performed. A significance level of 5% was considered. ΔE* ab and ΔE00 were significantly higher for CPc, CPn, CPa, and NCP groups. (∆WID) showed a significantly lower mean than the other groups for NC in T1. After bleaching (4-hour daily application for 14 days), Ra was higher in the CPc, CPn, and PC groups. For CPa, Ra was not altered. No significant difference was found in the quantification of mineral content. CPa preserved the surface smoothness more effectively. Aristoflex® AVC is a viable option for application as a thickener in dental bleaching gels, presenting satisfactory performance, and maintaining the whitening efficacy of the gel, with the advantage of preserving the surface roughness of tooth enamel without significant loss of mineral content.


Resumo Os polímeros Natrosol e Aristoflex® AVC são amplamente utilizados na indústria cosmética e foram recentemente aplicados como uma opção de espessante na composição de géis de clareamento dental, com o objetivo de reduzir os efeitos adversos sobre os componentes minerais do esmalte. O objetivo deste estudo foi avaliar a variação de cor (ΔE*ab, ΔE00, ∆WID), rugosidade da superfície (Ra), e quantificação do conteúdo mineral (Raman Spectroscopy) do esmalte dentário após clareamento dental com gel experimental baseado em 10% de peróxido de carbamida (CP), contendo Carbopol, Natrosol e Aristoflex® AVC. Sessenta dentes bovinos foram divididos aleatoriamente em 6 grupos (n=10): Controle Negativo (CN) - sem tratamento; Controle Positivo (CP) - Brancura Perfeita 10% - FGM; CP com Carbopol (CPc); CP com Natrosol (CPn); CP com Aristoflex® AVC (CPa); NCP - sem espessante. Os dados foram analisados e modelos lineares generalizados (∆WID -T0 x T1) foram usados para medições repetidas no tempo para Ra e com um fator de estudo para ΔE*ab e ΔE00. Para a avaliação do conteúdo mineral, os dados foram submetidos a testes unidirecionais de ANOVA e Tukey. Para a análise da superfície topográfica do esmalte, o Microscópio Eletrônico de Varredura (SEM) foi realizado. Um nível de significância de 5% foi considerado. ΔE*ab e ΔE00 foram significativamente maiores para os grupos CPc, CPn, CPa e NCP. (∆WID) mostrou uma média significativamente menor do que os outros grupos para NC em T1. Após o clareamento (aplicação diária de 4 horas por 14 dias), Ra foi maior nos grupos CPc, CPn e PC. Para CPa, Ra não foi alterado. Nenhuma diferença significativa foi encontrada na quantificação do conteúdo mineral. O CPa preservou a suavidade da superfície de forma mais eficaz. Aristoflex® AVC é uma opção viável para aplicação como espessante em géis de clareamento dental, apresentando desempenho satisfatório e mantendo a eficácia clareadora do gel, com a vantagem de preservar a rugosidade da superfície do esmalte dentário sem perda significativa de conteúdo mineral.

7.
Gels ; 9(1)2023 Jan 04.
Artigo em Inglês | MEDLINE | ID: mdl-36661808

RESUMO

The aim of this research was to develop and characterize the chemical and cellular-viability properties of an experimental high-concentration bleaching gel (35 wt%-H2O2) containing calcium-polyphosphate particles (CaPP) at two concentrations (0.5 wt% and 1.5 wt%). The CaPP submicroparticles were synthesized by coprecipitation, keeping a Ca:P ratio of 2:1. The CaPP morphology, size, and chemical and crystal profiles were characterized through scanning and transmission electron microscopy, energy-dispersive X-ray analysis, and X-ray diffraction, respectively. The assessed bleaching gels were experimental (without CaPP); 0.5% CaPP; 1.5% CaPP; and commercial. The gels' pH values and H2O2 concentrations (iodometric titration) were determined. The odontoblast-like cell viability after a gel's exposure was assessed by the MTT assay. The pH and H2O2 concentration were compared through a repeated-measures analysis of variance (ANOVA) and a Tukey's test and the cell viability through a one-way ANOVA and a Tukey's test using a GraphPad Prism (α < 0.05). The CaPP particles were spherical (with Ca and P, 135.7 ± 80.95 nm size) and amorphous. The H2O2 concentration decreased in all groups after mixing (p < 0.001). The 0.5% CaPP resulted in more-stable pH levels and higher viability levels than the experimental one (p < 0.05). The successful incorporation of CaPP had a positive impact on the bleaching gel's chemical and cellular-viability properties when compared to the experimental gel without these particles.

8.
RGO (Porto Alegre) ; 71: e20230022, 2023. graf
Artigo em Inglês | LILACS-Express | LILACS, BBO - Odontologia | ID: biblio-1449017

RESUMO

ABSTRACT The CAD/CAM technology arose from the need to develop materials with better mechanical and optical properties that could be used for making monolithic restorations. Several materials have been used for milling indirect restorations in prefabricated blocks. Among them, lithium silicate reinforced with zirconia. Due to its recent introduction in the market, this case report aimed to present a detailed clinical protocol for the execution of a ceramic onlay of this material using CAD/CAM technology. A 57-year-old female patient sought care with extensive restoration in composite resin (BOMD) of tooth 15 maintained for almost two years. However, due to bruxism, constant dental tightening, the extension of the direct restoration and the need for improved esthetics, it was proposed to replace it with an indirect ceramic onlay restoration. Prophylaxis and choice of the color of the patient's dental substrate were performed. Afterwards, the dental preparation was made and polished. Subsequently, the molding was made with addition silicone and the provisional restoration confectioned. Once the stone model was obtained, it was scanned and the ceramic onlay restoration was milled using CAD/CAM technology. Finally, the restoration was stained and cemented over the preparation. After 2 years, the restoration remained stable, with no evidence of color mismatch, marginal discoloration, marginal cleft, caries or fracture, proving the effectiveness of the treatment in this time interval. The correct indication of the ceramic material combined with the use of CAD/CAM technology facilitated the restorative process, restoring function and the esthetics desired by the patient.


RESUMO A tecnologia CAD/CAM surgiu da necessidade de desenvolvimento de materiais com melhores propriedades mecânicas e ópticas que pudessem ser utilizados para confecção de restaurações monolíticas. Diversos materiais têm sido utilizados para fresagem de restaurações indiretas em blocos pré-fabricados. Dentre eles, o silicato de lítio reforçado com zircônia. Devido a sua recente introdução no mercado, este relato de caso objetivou apresentar um protocolo clínico detalhado para a execução de uma onlay cerâmica desse material utilizando a tecnologia CAD/CAM. Paciente, 57 anos, sexo feminino, procurou atendimento com extensa restauração em resina composta envolvendo as faces (MODV) do dente 15 mantida por quase dois anos. Contudo, em virtude do bruxismo, do apertamento dental constante, da extensão da restauração direta e da necessidade de melhora na estética, foi proposto a substituição por uma restauração indireta em cerâmica do tipo onlay. Foi realizada a profilaxia e escolha da cor do substrato dental da paciente. Em seguida o preparo dental foi confeccionado e polido. Posteriormente foi feita a moldagem com silicone de adição e a confecção do provisório. Com a obtenção do modelo, este foi escaneado e fresada a onlay cerâmica pela tecnologia CAD/CAM, que posteriormente foi maquiada e cimentada sobre o preparo. Após 2 anos, a restauração permaneceu estável, sem evidência de incompatibilidade de cor, descoloração marginal, fenda marginal, cárie ou fratura, comprovando a eficácia do tratamento neste intervalo de tempo. A correta indicação do material cerâmico aliada ao uso da tecnologia CAD-CAM facilitou o processo restaurador devolvendo função e a estética desejada pela paciente.

9.
Braz. oral res. (Online) ; 37: e047, 2023. tab, graf
Artigo em Inglês | LILACS-Express | LILACS, BBO - Odontologia | ID: biblio-1439732

RESUMO

Abstract To evaluate the feasibility of using a milled polyetheretherketone (PEEK) post and core in endodontically treated teeth with or without a ferrule. Sixty bovine tooth roots were endodontically treated followed by cementation of intraradicular retainers (IR), according to each experimental group: a) non-ferrule glass fiber post (f0FP); b) 2-mm-ferrule glass fiber post (f2FP); c) non-ferrule resized glass fiber post (f0PR); d) 2-mm-ferrule resized glass fiber post (f2PR); e) non-ferrule PEEK post and core (f0PPC); and f) 2-mm-ferrule PEEK post and core (f2PPC). Metal crowns were made and cemented. A periodontal ligament was simulated using polyether. A force was applied to the palatine portion of each sample at 45°, until fracture. Fracture resistance data were submitted to two-way ANOVA and Tukey's test (α = 0.05). Three-dimensional digital models were developed to calculate the tensions formed in the root using finite element analysis. Models of glass fiber posts and PEEK posts and cores were evaluated with or without a ferrule. The results were analyzed by the Mohr-Coulomb criterion. The type of IR was not influenced by fracture strength (p = 0.243). There were significant statistical differences among the remaining factors. Ferrule groups had greater fracture resistance, and the failure mode of teeth with a ferrule was more catastrophic than the non-ferrule group. A ferrule increases fracture resistance and influences failure mode; the PEEK post and core did not modify the biomechanics of endodontically treated teeth, and resembled the glass fiber post results. The crack initiation point differed between the ferrule and non-ferrule groups.

10.
J. appl. oral sci ; 31: e20220428, 2023. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1440412

RESUMO

Abstract Objective To characterize activated charcoal and 2% hydrogen peroxide-based toothpastes and investigate their effects on roughness, color change, and gloss of bulk-fill composite resin. Methodology Composite resin specimens (Aura Bulk Fill, SDI) were subjected to 5,000 brushing cycles with regular toothpaste (Colgate Total 12, [RT]), activated charcoal toothpaste (Bianco Dental Carbon, [AC]), or hydrogen peroxide-containing toothpaste (Colgate Luminous White Advanced, [HP]), with or without coffee exposure. The pH, particle characterization by scanning electron microscopy (SEM), and weight% of solid particles in the toothpaste were assessed. Roughness (Ra) was evaluated using a surface profile-measuring device, color change (∆Eab/∆E00) by reflectance spectrophotometer, and gloss unit (GU) by glossmeter. Kruskal-Wallis, Dunn, Friedman, and Nemenyi tests were used, and the correlation coefficient test was performed between Ra and GU (α=0.05). Results RT presented a higher Ra after brushing and did not change after staining with coffee; moreover, the ∆Eab/∆E00 values were higher for RT than HP. Regarding gloss, AC and HP obtained higher values compared to RT. A significant negative correlation between gloss and Ra was found for RT exposed to coffee. All toothpastes had a neutral pH; however, RT had the largest percentage of solids by weight. SEM images showed particles of many sizes: irregular shape (RT), more regular particles (AC), and spherical clusters (HP). Although surface roughness, color change, and gloss may compromise the longevity of restorations, the whitening toothpastes tested did not promote more morphology changes than regular toothpastes.

11.
Braz. j. oral sci ; 21: e226202, jan.-dez. 2022. ilus
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1393187

RESUMO

Aim: Resin modified glass ionomer (RMGI) is class of material that can be used as sealant for preventing and arresting the progression of caries in pits and fissures. As these are hybrid materials, their properties can be affected by factors related to the polymerization process. Therefore, this study aimed to evaluate the influence of different generations of LED curing units (Elipar DeepCure-L and VALO Grand) on Knoop microhardness values (KHN) of RMGI sealants (Clinpro XT and Vitremer). Methods: Forty cylindrical specimens (6mm ø x 1 mm high) were prepared according to the manufacturer's instructions and divided into four groups (n=10) according to the type of RMGI and LED used. The KHN of the top surface of each sample was calculated 7 days after light-curing. Data were submitted to two-way ANOVA (α = 0.05). Results: Vitremer had higher KHN values than Clinpro XT after using both LEDs (p<0.0001), but especially when light-cured with the use of VALO Grand (p<0.0001). Whereas the KHN value of Clinpro was not influenced by the LED device (p>0.05). Conclusions: Top surface microhardness values of RGMI sealants were affected by both material composition and generations of LED curing units used. Third generation LED curing units seemed to be more efficient for the polymerization of RMGI-based sealants


Assuntos
Selantes de Fossas e Fissuras , Lâmpadas de Polimerização Dentária , Polimerização , Dureza
12.
Biosci. j. (Online) ; 38: e38056, Jan.-Dec. 2022. tab
Artigo em Inglês | LILACS | ID: biblio-1396538

RESUMO

The aim of this randomized double-blinded study was to evaluate the enamel surface roughness and color change after one month of whitening toothpaste use and the color stability obtained 1 month after its interruption. 30 volunteers were divided into 3 groups (n = 10) corresponding to the dentifrices: 1) Colgate Total 12 Clean Mint (TD) (Control), 2) Colgate Luminous White (LW) and 3) Sensodyne Whitening Extra Fresh (SB). The volunteers were impression with addition silicone to obtain an epoxy resin replica of the upper central incisor for the initial surface roughness evaluation using a profilometer and the initial color of the incisors and canines was evaluated with a spectrophotometer after one week of wash-out. After 1 month, the color of the central incisors and canines was measured again, and the volunteers were molded to obtain a second replica to the final roughness analysis. Data were submitted to ANOVA-one way (p≤0.05). The results showed that there was no statistical difference between the dentifrices for color difference and surface roughness for all the studied conditions. It was possible to conclude that the whitening dentifrices used in this study were not able to alter the initial color of the teeth and did not cause changes in the surface roughness of enamel.


Assuntos
Clareamento Dental , Cor , Esmalte Dentário , Dentifrícios
13.
Braz. J. Pharm. Sci. (Online) ; 58: e19501, 2022. graf
Artigo em Inglês | LILACS | ID: biblio-1383974

RESUMO

Abstract This study reviews the knowledge on the use of conventional dental whitening and the use of enzymes as a new approach in bleaching. A review of the literature was based on academic articles and on patents related to the use of enzymes in dental bleaching. Tooth whitening techniques used nowadays are well reported in the literature, and its mechanism of action consists of an oxidoreduction reaction with the release of free radicals. The great instability of radicals, when in contact with the tissues, promotes oxidation and reduction in the size of the pigment chains incorporated into them. These pigments are eventually broken down into smaller and smaller molecular chains and end up being diffused from the dental structure. In turn, the use of enzymes aimed at tooth whitening can be a less harmful alternative to the tooth because their specificity regarding the substrate makes them of great interest to perform specific reactions, reducing collateral effects. The use of proteolytic enzymes and oxidoreductases paired with the application of peroxides, can be a promising alternative for obtaining even better results in the dental bleaching process.


Assuntos
Enzimas/análise , Clareadores Dentários/análise , Oxirredutases/administração & dosagem , Dente , Odontologia/classificação , Literatura
14.
J. appl. oral sci ; 30: e20220285, 2022. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1405374

RESUMO

Abstract Bleaching gel thickeners induce important changes in tooth enamel and these changes are reversed by saliva. Objective This in situ study aimed to evaluate the effect of bleaching gels with different thickeners on tooth enamel under normal and hyposalivation conditions. Methodology Of 28 participants, 14 had normal salivary flow and 14 had low salivary flow. For each salivary flow, four types of treatment were performed with different thickeners: no bleaching (negative control), bleaching with a commercial 10% carbamide peroxide (CP) gel with carbopol (positive control) and bleaching with experimental 10% CP gels with natrosol and aristoflex. Participants used a palatal appliance containing bovine enamel/dentin specimens for 15 days. From day 2 to day 15, specimens were bleached extraorally. The bleaching gel was applied according to the groups for four hours. When the bleaching gel was removed, the palatal appliance was inserted again in the participants' mouth until the next day for another bleaching application. This procedure was repeated for 14 days and on day 15, surface microhardness (SMH), color (ΔE*ab and ΔE00), surface roughness (Ra), scanning electron microscopy (SEM), and energy-dispersive X-ray spectrometry (EDS) analyses were performed and data were subjected to statistical analysis. Results Neither salivary flow nor thickeners influenced ΔE*ab and ΔE00 results. Carbopol had the lowest SMH, the highest Ra, and the lowest Ca% among all groups. For normal flow, natrosol and aristoflex had higher SMH. For low flow, aristoflex had higher SMH and natrosol and aristoflex had lower Ra. Aristoflex had higher Ca% and Ca/P and differed from carbopol for normal flow. Conclusion For normal flow, 10% CP gels with natrosol and aristoflex caused fewer surface changes, and for low flow, only the 10% CP gel with aristoflex.

15.
J. appl. oral sci ; 28: e20190755, 2020. tab, graf
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1134785

RESUMO

Abstract Objective To clinically assess the effect of desensitizing gels and dentifrices on the reduction in pain sensitivity and color variation during tooth bleaching. Methodology A total of 108 volunteers were randomly separated into the following groups of n=12: GT/S-glycerine and thickener/sucralose; NF/S-potassium nitrate and sodium fluoride/sucralose; NA/S-potassium nitrate and arginine/sucralose; GT/AC-glycerine and thickener/arginine and calcium carbonate; NF/AC-potassium nitrate and sodium fluoride/arginine and calcium carbonate; NA/AC-potassium nitrate and arginine/arginine and calcium carbonate; GT/PN-glycerine and thickener/potassium nitrate; NF/PN-potassium nitrate and sodium fluoride/potassium nitrate; and NA/PN-potassium nitrate and arginine/potassium nitrate. Sensitivity was assessed with the numerical analogue scale, and color variation (ΔE) was measured with a spectrophotometer. The sensitivity values obtained were subjected to a multivariate analysis of variance (MANOVA) and color variation values were subjected to a randomized analysis of variance (p<0.05). Results The NF/AC, NA/AC, NF/PN, and NA/PN groups presented lower sensitivity values and reduced sensitivity compared to those of the other groups throughout the clinical sessions. None of the groups showed sensitivity at the 24-week assessment. Statistically, no significant difference were observed in the color values among the groups four weeks after the beginning of bleaching (p=0.074). Additionally, the color assessment of all groups was statistically similar four weeks (p=0.084) and 24 weeks (p=0.118) after the beginning. Conclusion Our results indicate that adding NF/S, NA/S, NF/AC, and NA/AC desensitizers to tooth bleaching protocols reduces pain sensitivity without affecting its effectiveness.


Assuntos
Humanos , Clareamento Dental , Sensibilidade da Dentina , Dessensibilizantes Dentinários , Clareadores Dentários , Dor , Seguimentos , Resultado do Tratamento , Compostos de Potássio
16.
Braz. j. oral sci ; 19: e207508, jan.-dez. 2020. ilus
Artigo em Inglês | BBO - Odontologia, LILACS | ID: biblio-1116543

RESUMO

Aim: Glass fiber posts are indicated in the rehabilitation of extensively damaged teeth; their cementation represents a critical step in restorative dentistry. The aim of this study was to quantify and compare the push-out bond strength of glass fiber posts cemented by conventional technique, two-step technique with luting agent and two-step technique associating bulk-fill composite and luting agent. Methods: Eighty maxillary bovine incisors were endodontically treated and divided into eight groups (n = 10) according to the luting agent (Rely X ARC and Duo-link) and cementation technique (conventional technique; two-step technique with luting agent; and two-step technique associating bulk-fill composite ­ Filtek Bulk-fill flow or Surefil SDR flow ­ and luting agent). Samples were submitted to pushout bond strength test, and the fracture pattern was evaluated through scanning electron microscope. Data were submitted to two-way ANOVA and Tukey's test (α = 0.05). Results: When Rely X ARC was used, the conventional cementation technique obtained higher bond strength values than the twostep technique associated with Filtek Bulk-fill flow. When Duolink was used, the two-step technique associated with Filtek Bulk-fill flow presented higher bond strength values than the conventional technique. The most prevalent fracture patterns were adhesive between luting agent and dentin, and adhesive between bulk-fill composite and dentin. Conclusion: Two-step cementation technique associated with bulk-fill composite may be promising depending on the luting agent used


Assuntos
Cimentação/métodos , Resinas Compostas , Cimentos Dentários
17.
Braz. dent. sci ; 23(3): 1-8, 2020. ilus, tab
Artigo em Inglês | BBO - Odontologia, LILACS | ID: biblio-1117327

RESUMO

Objective: This study aimed to evaluate the surface microhardness and morphology, as well as the microshear bond strength of a self-etching adhesive (Clearfil SE, Kuraray) to eroded dentin, exposed or not to cigarette smoke. Forty dental crowns were divided into 4 groups (n = 10): no treatment (control) (C); erosion (E); erosion + cigarette smoke exposure (ES); cigarette smoke exposure (S). Samples were prepared through third molars polishing until dentin exposure, followed by crown section. Erosive cycles were performed 5 times/day for 30 s at 60 min intervals. Cigarette smoke was produced with twenty cigarettes/day, during 5 days. Microhardness was evaluated initially and after the treatments. Microshear bond strength was tested after the treatments and dentin restoration with flow composite. Failure patterns and dentin morphology was evaluated by Scanning Electron Microscopy. Microshear bond strength data was submitted to two-way ANOVA, microharness test was adjusted by gamma distribution to be a non-parametric analyses (p=0.05), and surface morphology as qualitative analyses. Loss percentage of microhardness was observed only in groups submitted to erosion. Bond strength was statistically similar between all groups. The most prevalent failure pattern was of adhesive type. Morphological analysis of dentin showed obliterated tubules in groups submitted to cigarette smoke exposure. Cigarette smoke exposure did not promote any effect in the percentage of microhardness loss, as in sound dentin as in eroded dentin. Cigarette smoke, erosion, and association of both, did not alter the bond strength of self-etching adhesives to dentin. (AU)


Objetivo: Este estudo teve como objetivo avaliar a microdureza (% perda de dureza) e morfologia de superfície (MS), assim como a resistência de união (RU) de um adesivo autocondicionante (Clearfil SE, Kuraray) à uma dentina erodida, exposta ou não à fumaça de cigarro. Material e Métodos: Quarenta coroas dentais de terceiros molares foram seccionadas da raiz e polidas até a exposição dentinária, sendo aleatoriamente divididas em 4 grupos (n=10): sem tratamento (controle), erosão (E), erosão+ exposição a fumaça de cigarro (ES); exposição a fumaça de cigarro (S).O ciclo erosivo foi realizado 5 vezes/dia por 30s, com 60 minutos de intervalo entre eles. Os grupos ES e S foram exposto à fumaça de cigarro produzida por 20 cigarros/dia, durante 5 dias. A avaliação da microdureza foi realizada antes e após os tratamentos, enquanto a resistência da união por microcisalhamento foi realizada após os tratamentos Os padrões de fratura representativos e a MS dentinária foram avaliados por microscopia eletrônica de varredura (MEV). Os dados de RU foram analisados por ANOVA dois fatores, enquanto a análise de microdureza foi ajustada por distribuição gama por ser uma análise não-paramétrica (p=0.05). A MS foi analisada qualitativamente. Resultados: Os grupos expostos aos ciclos erosivos (E e ES) apresentaram % de perda de dureza significativamente menor que os grupos não expostos (Controle e S. aos ciclos erosivos (E e ES). Para RU, não houve diferença estatística significativa entre os grupos. O padrão de fratura mais observado foi do tipo adesivo, e através das imagens obtidas por MEV, observou-se a obliteração de túbulos dentinários no grupo exposto à fumaça de cigarro, enquanto os grupos submetidos aos ciclos erosivos (E e ES) apresentaram maior exposição e diâmetro de túbulos dentinários. Conclusão: A exposição à fumaça de cigarro não promove nenhum efeito quanto a perda de porcentagem de dureza dentinária, assim como em dentina erodida e saudável. A fumaça de cigarro, o processo erosivo, e a associação de ambos, não altera a resistência da união de adesivos autocondicionantes à dentina. (AU)


Assuntos
Resistência à Tração , Erosão Dentária , Coroas , Cimentos Dentários , Produtos do Tabaco
18.
Braz Oral Res ; 33: e114, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31800865

RESUMO

This in vitro study aimed to evaluate the effect of different toothpastes on dental enamel subjected to an erosive cycle with and without exposure to cigarette smoke. Bovine enamel specimens were randomly allocated into 12 groups (n = 12). For the in vitro simulation of smoking, half the groups underwent an exposure cycle of 20 cigarettes per day for 5 days. Subsequently, all groups were subjected to a 5-day erosion cycle intercalating demineralization (1 min; 1% citric acid; pH = 3.5) and treatment with toothpaste slurries (2 min) of NaF, SnF2, F/Sn/Chitosan, F/CaSiO3/Na3PO4, and F/bioactive glass. The control group was immersed in distilled water. Surface microhardness (SMH) was measured initially, after exposure to smoke, and after the erosive cycle, and %SMH was calculated. At the end of the experimental cycle, surface roughness, profilometry, and atomic force microscopy (AFM) were performed. SMH increased after exposure to cigarette smoke (p < 0.05). After the erosive cycle, there were no differences between the presence and absence of cigarette smoke exposure in SMH and roughness (p > 0.05). Besides increasing enamel SMH, cigarette smoke did not prevent enamel loss after the erosion cycle (p < 0.05). In profilometry, roughness and surface loss had the lowest values in the groups treated with SnF2 and F/Sn/Chitosan (p < 0.05). AFM showed lower mineral loss with F/CaSiO3/Na3PO4 and F/Sn/Chitosan. For all groups, except F/CaSiO3/Na3PO4, cigarette smoke resulted in higher enamel wear. F/Sn/Chitosan showed the best results against erosion.


Assuntos
Fumar Cigarros/efeitos adversos , Esmalte Dentário/efeitos dos fármacos , Erosão Dentária/etiologia , Erosão Dentária/prevenção & controle , Cremes Dentais/uso terapêutico , Animais , Compostos de Cálcio/uso terapêutico , Cariostáticos/uso terapêutico , Bovinos , Quitosana/uso terapêutico , Testes de Dureza , Humanos , Microscopia de Força Atômica , Valores de Referência , Reprodutibilidade dos Testes , Saliva/química , Silicatos/uso terapêutico , Propriedades de Superfície/efeitos dos fármacos , Fatores de Tempo , Fluoretos de Estanho/uso terapêutico , Desmineralização do Dente/induzido quimicamente , Desmineralização do Dente/prevenção & controle , Água/química
19.
J. health sci. (Londrina) ; 21(1)30/04/2019.
Artigo em Inglês | LILACS | ID: biblio-995924

RESUMO

The aim of this study was to evaluate the surface roughness of a silorane and methacrylate-based composite resins subjected to different finishing/polishing techniques. Twelve disk specimens were prepared from each composite resin: P90®, Z350® and Charisma, divided into 12 groups according to the finishing/polishing technique: no finishing/polishing (control); finishing with 1112 FF diamond burs; finishing with 1112 FF diamond burs associated to Enhance/Pogo; finishing with 1112 FF diamond burs associated to Enhance/Pogo/Polishing/Poli I and II pastes/Fotogloss. After initial readouts of surface roughness, the specimens were subjected to mechanical cycling (1.200.000 cycles) and immediately subjected to final roughness readouts. Surface roughness means was statistically analyzed by ANOVA and Tukey-Kramer test (α=0.05). SEM images were realized after finishing/polishing and after mechanical cycling. The P90 composite showed surface roughness values similar to other investigated composites. However, significant difference was observed in finishing/polishing techniques. The diamond burs group showed the highest surface roughness differing from the other composite resins (α < 0.05). Enance/Pogo showed the lowest results, which presented no difference compared to the polishing paste group (α > 0.05). The low-shrink posterior restorative showed similar surface roughness when compared to dimethacrylate composite resins and suitable to posterior restorations. (AU).


O objetivo deste estudo foi avaliar a rugosidade superficial de resinas compostas à base silorano e metacrilato submetidas a diferentes técnicas de acabamento/polimento. Foram preparadas 12 amostras de disco de cada resina composta: P90®, Z350® e Carisma, divididas em 12 grupos de acordo com a técnica de acabamento / polimento: sem acabamento / polimento (controle); acabamento com ponta diamantada 1112 FF; acabamento com ponta diamantada 1112 FF associada a Enhance / Pogo; acabamento com ponta diamantada 1112 FF associada a Enhance / Pogo / Polishing / Pastas Poli I e II / Fotogloss. Após as leituras iniciais da rugosidade da superfície, os espécimes foram submetidos a ciclos mecânicos (1.200.000 ciclos) e submetidos imediatamente a leituras de rugosidade final. As medias de rugosidade superfícial foram analisadas estatisticamente por ANOVA e teste de Tukey-Kramer (α = 0,05). As imagens de MEV foram realizadas após o acabamento / polimento e após a ciclagem mecânica. O compósito P90 mostrou valores de rugosidade superficial semelhantes a outros compósitos investigados. Tough, mostrou diferença significativa nas técnicas de acabamento / polimento. O grupo de pontas damantadas apresentou maior rugosidade superficial que diferiu das outras resinas compostas (α <0,05). Enance / Pogo mostrou os menores resultados, que não apresentaram diferença em relação ao grupo de pasta de polimento (α> 0,05). O material restaurador posterior de baixa contração apresentou rugosidade superficial semelhante quando comparado as resinas compostas de dimetacrilato e são restaurações adequadas para região posterior. (AU).

20.
Braz. j. oral sci ; 18: e191663, jan.-dez. 2019. ilus
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1095340

RESUMO

Color changes may interfere with smile balance and they represent a clinical challenge to dentists. Dental fluorosis originates from intrinsic factors and it is a disorder of enamel formation during the phase of teeth development, resulting in the change of enamel color. This clinical case report aimed to present the resolution of a case of dental fluorosis through the association of minimally invasive techniques, namely microabrasion and tooth bleaching. A 27-year-old male patient sought the dental clinic of the School of Dentistry of Piracicaba (FOP - UNICAMP, Brazil) presenting striped and symmetrical white stains and generalized chromogenic biofilm. After anamnesis and clinical examination, the patient was diagnosed with fluorosis stains. Initially, adequacy of the oral environment was performed with prophylaxis and supragingival scraping. Then, the enamel microabrasion technique was performed with 6% hydrochloric acid associated with silicon carbide (Whiteness RM - FGM) and supervised at-home bleaching was performed with 16% carbamide peroxide (Whiteness Simple 16% - FGM). In conclusion, the treatment performed reestablished the aesthetics and harmony of smile color with minimally invasive procedures without causing tooth sensitivity


Assuntos
Humanos , Masculino , Adulto , Clareamento Dental , Microabrasão do Esmalte , Estética Dentária , Fluorose Dentária
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA