RESUMO
The development of new orally inhaled drug products requires their demonstration of safety, which must be proven in animal experiments. New in vitro methods may replace, or at least reduce, these animal experiments, provided they are able to correctly predict safety or possible toxicity in humans. However, the challenge is to link in vitro data obtained in human cells to human in vivo data. We here present a new approach to the safety assessment of excipients (SAFE) for pulmonary drug delivery. The SAFE model is based on a dose response curve of 23 excipients tested on the human pulmonary epithelial cell lines A549 and Calu-3. The resulting in vitro IC50 values were correlated with the FDA-approved concentrations in pharmaceutical products for either pulmonary (if available) or parenteral administration. Setting a threshold of 0.1% (1 mg/mL) for either value yielded four safety classes and allowed to link IC50 data as measured in human cell cultures in vitro with the concentrations of the same compounds in FDA-approved drug products. The necessary in vitro data for novel excipients can be easily generated, and the SAFE approach allows putting them into context for eventual use in human pulmonary drug products. Excipients that are most likely not safe for use in humans can be excluded early on from further pharmaceutical development. The SAFE approach thus helps to avoid unnecessary animal experiments.
Assuntos
Excipientes/toxicidade , Preparações Farmacêuticas/administração & dosagem , Administração por Inalação , Administração Oral , Linhagem Celular Tumoral , Humanos , Concentração Inibidora 50RESUMO
Pharmaceuticals based on proteins (biologicals), such as monoclonal antibodies (mAb), attain more and more relevance since they were established as potent drugs in anticancer therapy or for the treatment of autoimmune based diseases. Due to their high efficiency it is essential to have accurate and precise methods for protein quantitation and the detection of protein aggregates, which in some cases may lead to adverse effects after application. Selectivity and precision of traditional protein quantification methods such as the Bradford assay or SDS-PAGE are insufficient for quality control (QC) purposes. In this work several HPLC separation modes, which can significantly improve these important parameters, were compared for their application in this field. High performance size exclusion (HP-SEC), strong anion exchange (SAX), weak cation exchange (WCX) as well as reversed phase chromatography are all already successfully applied in protein analysis. Good precision (SEC: <1.9%, SAX: <5%, RP: <2% and WCX: <3.5% - RSD% for peak areas day-to-day), high selectivity and low quantitation limits (<15µg/ml) for the model proteins ovalbumin, myoglobin and bovine serum albumin (BSA), respectively cytochrome c and lysozyme in the cation exchange mode, could be achieved. Consecutively, the four separation modes were compared to each other and to electrophoretic techniques in terms of precision, selectivity, analysis time, effort of sample and mobile phase preparation as well as separating capacity. Moreover, the analysis of an IgG1-type antibody was included in this study.