Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 31
Filtrar
1.
J Formos Med Assoc ; 2024 Jan 20.
Artigo em Inglês | MEDLINE | ID: mdl-38246800

RESUMO

BACKGROUND/PURPOSE: Zirconia has been a popular material in dental implantology with good biocompatibility. But few research focused on its application in implant drills. This study aimed to investigate the physical, thermal, and biological effects on using the zirconia and stainless-steel drills for implant bone site preparation. METHODS: We performed a series of experiments to evaluate the physical wearing properties of zirconia and stainless-steel drills of identical diameter and similar shape. During the implant site preparation thermal test, we subjected both drills onto a resin-embedded bone, utilizing a thermal couple device without irrigation. Moreover, we conducted a cell study by collecting bone cells in vivo while preparing the implant site with both tested drills. The cell activity was evaluated through cell proliferation colorimetric analysis (XTT) and alkaline phosphatase (ALP) activity measurements. RESULTS: The zirconia drill outperforms the stainless-steel drill in terms of requiring less force, maintaining stability over repeated cutting tests, and generating lower temperatures during drilling (stainless-steel drill: 45.48 ± 1.31 °C; zirconia-coated drill: 32.98 ± 1.21 °C, P = 0.000247). Meanwhile, both types of drills show similar results in XTT colorimetric analysis and ALP activity test. CONCLUSION: The thermal effect study is more favorable for using the zirconia drill than the stainless-steel drill for bone preparation. Cytological analysis indicate that the zirconia drill produces a similar impact on bone cells activity as the stainless-steel drill. Therefore, we conclude that the zirconia drills offer a good cutting effect similar to currently available stainless-steel drills in various aspects.

2.
J Periodontal Res ; 58(1): 155-164, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36451314

RESUMO

BACKGROUNDS: Periodontitis is an oral-bacteria-directed disease that occurs worldwide. Currently, periodontal pathogens are mostly determined using traditional culture techniques, next-generation sequencing, and microbiological screening system. In addition to the well-known and cultivatable periodontal bacteria, we aimed to discover a novel periodontal pathogen by using DNA sequencing and investigate its role in the progression of periodontitis. OBJECTIVE: This study identified pathogens from subgingival dental plaque in patients with periodontitis by using the Oxford Nanopore Technology (ONT) third-generation sequencing system and validated the impact of selected pathogen in periodontitis progression by ligature-implanted mice. METHODS: Twenty-five patients with periodontitis and 25 healthy controls were recruited in this study. Subgingival plaque samples were collected for metagenomic analysis. The ONT third-generation sequencing system was used to confirm the dominant bacteria. A mouse model with ligature implantation and bacterial injection verified the pathogenesis of periodontitis. Neutrophil infiltration and osteoclast activity were evaluated using immunohistochemistry and tartrate-resistant acid phosphatase assays in periodontal tissue. Gingival inflammation was evaluated using pro-inflammatory cytokines in gingival crevicular fluids. Alveolar bone destruction in the mice was evaluated using micro-computed tomography and hematoxylin and eosin staining. RESULTS: Scardovia wiggsiae (S. wiggsiae) was dominant in the subgingival plaque of the patients with periodontitis. S. wiggsiae significantly deteriorated ligature-induced neutrophil infiltration, osteoclast activation, alveolar bone destruction, and the secretion of interleukin-6, monocyte chemoattractant protein-1, and tumor necrosis factor-α in the mouse model. CONCLUSION: Our metagenome results suggested that S. wiggsiae is a dominant flora in patients with periodontitis. In mice, the induction of neutrophil infiltration, proinflammatory cytokine secretion, osteoclast activation, and alveolar bone destruction further verified the pathogenic role of S. wiggsiae in the progress of periodontitis. Future studies investigating the metabolic interactions between S. wiggsiae and other periodontopathic bacteria are warranted.


Assuntos
Actinobacteria , Perda do Osso Alveolar , Placa Dentária , Periodontite , Camundongos , Animais , Microtomografia por Raio-X/efeitos adversos , Perda do Osso Alveolar/patologia , Periodontite/metabolismo , Bactérias , Placa Dentária/complicações
3.
J Periodontol ; 93(9): 1401-1410, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-34967007

RESUMO

BACKGROUND: Periodontal disease is a chronic inflammatory disease. Given its high prevalence, especially in aging population, the detailed mechanisms about pathogenesis of periodontal disease are important issues for study. Neutrophil firstly infiltrates to periodontal disease-associated pathogen loci and amplifies the inflammatory response for host defense. However, excessive neutrophil-secreted neutrophil elastase (NE) damages the affected gingival. In lung and esophageal epithelium, NE had been proved to upregulate several growth factors including placenta growth factor (PGF). PGF is an angiogenic factor with proinflammatory properties, which mediates the progression of inflammatory disease. Therefore, we hypothesize excessive NE upregulates PGF and participates in the pathogenesis and progression of periodontal disease. METHODS: In gingival epithelial cells (GEC), growth factors array demonstrated NE-increased growth factors and further be corroborated by Western blot assay and ELISA. The GEC inflammation was evaluated by ELISA. In mice, the immunohistochemistry results demonstrated ligature implantation-induced neutrophil infiltration and growth factor upregulation. By multiplex assay, the ligature-induced proinflammatory cytokines level in gingival crevicular fluid (GCF) were evaluated. Finally, alveolar bone absorption was analyzed by micro-CT images and H & E staining. RESULTS: NE upregulated PGF expression and secretion in GEC. PGF promoted GEC to secret IL-1ß, IL-6, and TNF-α in GCF In periodontal disease animal model, ligature implantation triggered NE infiltration and PGF expression. Blockade of PGF attenuated the ligature implantation-induced IL-1ß, IL-6, TNF-α and MIP-2 secretion and ameliorated the alveolar bone loss in mice. CONCLUSION: In conclusion, the NE-induced PGF triggers gingival epithelium inflammation and promotes the pathogenesis and progression of periodontal disease.


Assuntos
Gengivite , Doenças Periodontais , Animais , Camundongos , Indutores da Angiogênese/análise , Citocinas , Líquido do Sulco Gengival/química , Inflamação , Interleucina-6/análise , Elastase de Leucócito/análise , Fator de Crescimento Placentário/análise , Fator de Necrose Tumoral alfa/análise
4.
J Formos Med Assoc ; 120(8): 1627-1634, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33593691

RESUMO

BACKGROUND/PURPOSE: Several growth factors were proven to be effective in the treatment of bone defects and fractures and thus have great potential for bone regeneration applications. However, it needs low-temperature storage and transportation. This study aimed to investigate the herbal extract quercetin, a candidate for natural flavonoid compounds that have been reported to be involved in regulating inflammation and improving immunity and health. METHODS: In this study, we prepared quercetin (Q)/mesoporous calcium silicate calcium sulfate (MSCS)/polycaprolactone (PCL) composite scaffolds using the 3D printing technique, where we immersed it in simulated body fluid (SBF) solution and soaked it for up to 60 days. The characteristics of quercetin scaffold were examined by scanning electron microscopy (SEM), X-ray diffraction (XRD), Fourier-transform infrared spectroscopy (FTIR), immunofluorescence, and Alizarin Red S staining. RESULTS: We found precipitation of apatite on the surface of the scaffold. The in vitro results for cell proliferation, cytotoxicity, and immunofluorescence staining revealed that Wharton's jelly mesenchymal stem cells (WJMSCs) with a 2% quercetin (Q2) scaffold were significantly higher in number than with 1% quercetin (Q1) and MSCS scaffolds. The phalloidin staining of cell skeletons on the surface of Q2 revealed powerful cell-to-cell adhesion and high expression of green fluorescence. The Q2 scaffold also had the highest calcium deposit levels based on Alizarin Red S staining in all scaffolds. This indicated that quercetin was able to induce cell growth and mitosis, echoing the previous preliminary results. CONCLUSION: Our initial results indicate that this natural herbal extract can be a good bone-based gene substitution for bone regeneration.


Assuntos
Células-Tronco Mesenquimais , Osteogênese , Compostos de Cálcio , Sulfato de Cálcio , Caproatos , Proliferação de Células , Lactonas , Impressão Tridimensional , Quercetina , Silicatos , Engenharia Tecidual , Alicerces Teciduais
5.
J Formos Med Assoc ; 120(3): 991-996, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32900578

RESUMO

BACKGROUND/PURPOSE: Cone-beam computed tomography (CBCT) is a useful device in creating 3-dimensional images in the examining area of dentistry and is one of the most common clinical methods in detecting second mesiobuccal (MB2) canals in maxillary molars. The aim of this in vitro study was to compare the image quality of the small field of view (FOV) CBCT with different rotation arcs and scanning speeds in the use of detecting root canals. METHODS: A dentate human skull was scanned in Morita 3D Accuitomo 170 with 4 × 4 cm FOV under 5 mA and 90 kVp. Two different rotation arcs (360° and 180°) and three different scanning modes (slow-speed mode, standard mode and high-speed mode) combined into six different groups. Five different levels of axial sections were selected from each group. Five endodontic specialists rated the image quality by focusing on the sharpness of the MB2 canal of the upper right first molar and the surrounding structures. RESULTS: Despite the rotation arcs, all the observers gave excellent ratings to images taken with slow-speed mode. The high-speed mode taken with 360° and 180° got the second lowest and the lowest ratings, respectively. Under the same scanning speed, the rotation arc did not have a significant difference in image quality. CONCLUSION: Slow-speed mode is inevitable in maintaining adequate image quality during taking CBCT. However, endodontists can use the half rotation mode to significantly reduce radiation dose, exposure time, and still maintain sufficient image quality for root canal anatomy assessment.


Assuntos
Cavidade Pulpar , Tomografia Computadorizada de Feixe Cônico , Cavidade Pulpar/diagnóstico por imagem , Humanos , Maxila/diagnóstico por imagem , Dente Molar/diagnóstico por imagem , Tratamento do Canal Radicular , Raiz Dentária
6.
Materials (Basel) ; 13(4)2020 Feb 11.
Artigo em Inglês | MEDLINE | ID: mdl-32054126

RESUMO

The aim of this study was to evaluate the efficacy of bone regeneration in developed bioceramics composed of dicalcium phosphate and hydroxyapatite (DCP/HA). Critical bony defects were prepared in mandibles of beagles. Defects were grafted using DCP/HA or collagen-enhanced particulate biphasic calcium phosphate (TCP/HA/Col), in addition to a control group without grafting. To assess the efficacy of new bone formation, implant stability quotient (ISQ) values, serial bone labeling, and radiographic and histological percentage of marginal bone coverage (PMBC) were carefully evaluated four, eight, and 12 weeks after surgery. Statistically significant differences among the groups were observed in the histological PMBC after four weeks. The DCP/HA group consistently exhibited significantly higher ISQ values and radiographic and histological PMCB eight and 12 weeks after surgery. At 12 weeks, the histological PMBC of DCP/HA (72.25% ± 2.99%) was higher than that in the TCP/HA/Col (62.61% ± 1.52%) and control groups (30.64% ± 2.57%). After rigorously evaluating the healing of biphasic DCP/HA bioceramics with a critical size peri-implant model with serial bone labeling, we confirmed that neutralized bioceramics exhibiting optimal compression strength and biphasic properties show promising efficacy in fast bone formation and high marginal bone coverage in peri-implant bone defects.

7.
J Formos Med Assoc ; 117(10): 879-887, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30097222

RESUMO

BACKGROUND/PURPOSE: The mesoporous calcium silicate (MesoCS) 3D-printed scaffold show excellent bioactivity and can enhance the bone-like apatite formation. The purpose of this study aims to consider the effects of the different loading methods on the novel grafting materials which composed of bone morphogenetic protein-2 (BMP-2) loaded MesoCS scaffold by employing 3D-printing technique. METHODS: The MesoCS scaffold were fabricated by fused deposition modeling. In this study, there are two methods of loading BMP-2: (1) the pre-loading (PL) method by mixing MesoCS and BMP-2 as a raw material for a 3D-printer, and (2) the direct-loading (DL) method by soaking the 3D-printed MesoCS scaffold in a BMP-2 solution. The characteristics of MesoCS scaffold were examined by transmission electron microscopy (TEM), X-ray diffraction (XRD) and scanning electron microscopy (SEM). Their physical properties, biocompatibility, and osteogenic-related ability were also evaluated. RESULTS: The 3D MesoCS/PCL scaffolds showed excellent biocompatibility and physical properties. After soaking in simulated body fluid, the bone-like apatite layer of the PL and DL groups could be formed. In addition, the DL group released fifty percent more than the PL group at the end of the first day and PL showed a sustained release profile after 2 weeks. CONCLUSION: The 3D MesoCS/PCL porous scaffolds were successfully fabricated via a 3D printing system and were tested in vitro and were found to show good cellular activity for cell behavior although the PL method was not favorable for clinical application in relation with the preservation of BMP-2. With regards to different growth factor loading methods, this study demonstrated that PL of BMP-2 into MesoCS prior to printing will result in a more sustained drug release pattern as compared to traditional methods of scaffolds directly immersed with BMP-2.


Assuntos
Materiais Biocompatíveis/química , Proteína Morfogenética Óssea 2/farmacologia , Compostos de Cálcio/química , Impressão Tridimensional , Silicatos/química , Engenharia Tecidual/métodos , Proteína Morfogenética Óssea 2/química , Compostos de Cálcio/farmacologia , Diferenciação Celular/efeitos dos fármacos , Proliferação de Células/efeitos dos fármacos , Células Cultivadas , Humanos , Células-Tronco Mesenquimais/citologia , Osteogênese/efeitos dos fármacos , Silicatos/farmacologia , Propriedades de Superfície , Alicerces Teciduais/química
8.
J Formos Med Assoc ; 116(4): 306-312, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-27375047

RESUMO

BACKGROUND/PURPOSE: Dental rotary instruments can be applied in multiple conditions of canals, but unpredictable fatigue fracture may happen. This study evaluated the fatigue lives of two batches of nickel-titanium (NiTi) dental rotary files operating in clinically simulated root canals. METHODS: Single-step cyclic fatigue tests were carried out to assess the performance of two batches of NiTi files (ProTaper and ProFile) in nine combinations of simulated canals (cylinder radii 5 mm, 7.5 mm, and 10 mm, and insertion angles 20°, 40°, and 60°). Two-step cyclic fatigue tests were carried out in simulated root canals with the same radius by using the following two sets of insertion angles: (20°, 40°), (20°, 60°), (40°, 20°), and (60°, 20°). Fracture surfaces were observed by scanning electron microscopy. RESULTS: The single-step cyclic fatigue results showed that cyclic fatigue lives of the files decreased with increasing insertion angles or decreasing cylinder radius. The ProFile #25 .04 file was more fatigue resistant than the ProTaper F2 file. In two-step cyclic fatigue tests, the total fatigue lives were usually more than 100% when the files operated at a lower strain and then at a higher strain. By scanning electron microscopy, a larger area of fatigue striation corresponded to a longer fatigue life. CONCLUSION: Cyclic fatigue life can be influenced by the strains and geometries of files. The fatigue life was prolonged when the files operated at a lower strain and then at a higher strain. However, the fatigue life was shortened if the loading sequence was reversed.


Assuntos
Teste de Materiais/métodos , Níquel , Preparo de Canal Radicular/instrumentação , Titânio , Análise do Estresse Dentário , Desenho de Equipamento , Falha de Equipamento , Humanos , Teste de Materiais/instrumentação , Microscopia Eletrônica de Varredura , Rotação , Estresse Mecânico
9.
J Formos Med Assoc ; 116(5): 373-379, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-27502895

RESUMO

BACKGROUND/PURPOSE: Dental nickel-titanium (NiTi) rotary instruments are widely used in endodontic therapy because they are efficient with a higher success rate. However, an unpredictable fracture of instruments may happen due to the surface characteristics of imperfection (or irregularity). This study assessed whether a novel surface treatment could increase fatigue fracture resistance of dental NiTi rotary instruments. METHODS: A 200- or 500-nm thick Ti-zirconium-boron (Ti-Zr-B) thin film metallic glass was deposited on ProTaper Universal F2 files using a physical vapor deposition process. The characteristics of coating were analyzed by scanning electron microscopy, transmission electron microscopy, and X-ray diffractometry. In cyclic fatigue tests, the files were performed in a simulated root canal (radius=5 mm, angulation=60°) under a rotating speed of 300rpm. The fatigue fractured cross sections of the files were analyzed with their fractographic performances through scanning electron microscopy images. RESULTS: The amorphous structure of the Ti-Zr-B coating was confirmed by transmission electron microscopy and X-ray diffractometry. The surface of treated files presented smooth morphologies without grinding irregularity. For the 200- and 500-nm surface treatment groups, the coated files exhibited higher resistance of cyclic fatigue than untreated files. In fractographic analysis, treated files showed significantly larger crack-initiation zone; however, no significant differences in the areas of fatigue propagation and catastrophic fracture were found compared to untreated files. CONCLUSION: The novel surface treatment of Ti-Zr-B thin film metallic glass on dental NiTi rotary files can effectively improve the fatigue fracture resistance by offering a smooth coated surface with amorphous microstructure.


Assuntos
Ligas Dentárias/uso terapêutico , Instrumentos Odontológicos/efeitos adversos , Preparo de Canal Radicular/métodos , Propriedades de Superfície , Fraturas dos Dentes/prevenção & controle , Ligas , Boro/administração & dosagem , Falha de Equipamento , Vidro , Humanos , Teste de Materiais , Preparo de Canal Radicular/efeitos adversos , Preparo de Canal Radicular/instrumentação , Titânio/administração & dosagem , Fraturas dos Dentes/etiologia , Oligoelementos/administração & dosagem , Zircônio/administração & dosagem
10.
Dent Mater ; 32(10): 1197-1208, 2016 10.
Artigo em Inglês | MEDLINE | ID: mdl-27492847

RESUMO

OBJECTIVES: Vital pulp therapy aims to treat reversible pulpal injuries via protective dentinogenesis and to preserve more tooth structure. Mineral trioxide aggregate (MTA)-based capping materials demonstrate prolonged setting time increases the risk of pulpal infection during multi-visit treatment. Their non-degradable property occupies pulp space and limits dentin-pulp regeneration. This study reports an inorganic degradable biomaterial that presents a short initial setting time and acts as a growth factor reservoir to promote reparative dentinogenesis. METHODS: We synthesize nanocrystalline calcium sulfate hemihydrate (nCS), hydroxyapatite (HAp) and calcium sulfate hemihydrate (CS) as a reservoir to which transforming growth factor-beta 1 (TGF-ß1) and vascular endothelial growth factor (VEGF) are added (denoted as nCS/HAp/CS/TGF-ß1/VEGF). In vitro biocompatibility and mineralization (the activity and expression of alkaline phosphatase, ALP) were evaluated. Rat animal model was created to test in vivo efficacy. RESULTS: Cultured human dental pulp cells (HDPCs) showed that nCS/HAp/CS/TGF-ß1/VEGF cement has excellent biocompatibility and the potential to elevate the activity and expression of ALP. The in vivo efficacy (rat animal model) indicates protective dentin by micro-computed tomography (µ-CT) measurements and histological analyses. The 3D µ-CT non-destructive analysis also determines volume changes during pulpotomy, suggesting that the degraded space of the nCS/HAp/CS/TGF-ß1/VEGF cement is repaired by the formation of dentin-pulp tissue. SIGNIFICANCE: These findings demonstrate that nCS/HAp/CS cement acts as a potent reservoir for the sustained release of growth factors, and that nCS/HAp/CS/TGF-ß1/VEGF cement has a high potential to form the reparative dentinogenesis in vivo.


Assuntos
Polpa Dentária/metabolismo , Fator de Crescimento Transformador beta1/metabolismo , Fator A de Crescimento do Endotélio Vascular/metabolismo , Animais , Sulfato de Cálcio/farmacologia , Durapatita/farmacologia , Humanos , Ratos , Microtomografia por Raio-X
11.
Acta Biomater ; 37: 165-73, 2016 06.
Artigo em Inglês | MEDLINE | ID: mdl-27060620

RESUMO

UNLABELLED: Recently, photodynamic therapy (PDT) is one of the new clinical options by generating cytotoxic reactive oxygen species (ROS) to kill cancer cells. However, the optical approach of PDT is limited by tissue penetration depth of visible light. In this study, we propose that a ROS-enhanced nanoparticle, hafnium-doped hydroxyapatite (Hf:HAp), which is a material to yield large quantities of ROS inside the cells when the nanoparticles are bombarded with high penetrating power of ionizing radiation. Hf:HAp nanoparticles are generated by wet chemical precipitation with total doping concentration of 15mol% Hf(4+) relative to Ca(2+) in HAp host material. The results show that the HAp particles could be successfully doped with Hf ions, resulted in the formation of nano-sized rod-like shape and with pH-dependent solubility. The impact of ionizing radiation on Hf:HAp nanoparticles is assessed by using in-vitro and in-vivo model using A549 cell line. The 2',7'-dichlorofluorescein diacetate (DCFH-DA) results reveal that after being exposed to gamma rays, Hf:HAp could significantly lead to the formation of ROS in cells. Both cell viability (WST-1) and cytotoxicity (LDH) assay show the consistent results that A549 lung cancer cell lines are damaged with changes in the cells' ROS level. The in-vivo studies further demonstrate that the tumor growth is inhibited owing to the cells apoptosis when Hf:HAp nanoparticles are bombarded with ionizing radiation. This finding offer a new therapeutic method of interacting with ionizing radiation and demonstrate the potential of Hf:HAp nanoparticles in tumor treatment, such as being used in a palliative treatment after lung surgical procedure. STATEMENT OF SIGNIFICANCE: Photodynamic therapy (PDT) is one of the new clinical options by generating cytotoxic reactive oxygen species (ROS) to kill cancer cells. Unfortunately, the approach of PDT is usually limited to the treatment of systemic disease and deeper tumor, due to the limited tissue penetration depth of visible light (620-690nm). Here we report a ROS-enhanced nanoparticle, hafnium-doped hydroxyapatite (Hf:HAp), which can trigger ROS when particles are irradiated with high penetrating power of ionizing radiation. The present study provides quantitative data relating ROS generation and the therapeutic effect of Hf:HAp nanoparticles in lung cancer cells. As such, this material has opened an innovative window for deeper tumor and systemic disease treatment.


Assuntos
Durapatita , Raios gama , Háfnio , Neoplasias Pulmonares , Modelos Biológicos , Nanopartículas/química , Linhagem Celular Tumoral , Durapatita/química , Durapatita/farmacologia , Háfnio/química , Háfnio/farmacologia , Humanos , Neoplasias Pulmonares/metabolismo , Neoplasias Pulmonares/radioterapia , Espécies Reativas de Oxigênio/metabolismo
12.
J Formos Med Assoc ; 115(10): 867-875, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26506918

RESUMO

BACKGROUND/PURPOSE: The Taiwan National Health Insurance program has allocated a specific fund for dental services to patients with specific disabilities (PSDs); however, the trends and the quality are unknown. In this study, we conducted quantity analyses and quality assessments of dental service use among PSDs using a nationwide population-based database. METHODS: PSDs were identified according to the codes of diagnosis fee. Quantity analyses included the number of patients receiving dental services, the number of visits, and the percentages of categories of dental service use. Quality assessments included refilling rates for operative dental treatments and unfinished rates for endodontic therapies. RESULTS: For quantity analyses, dental services were accessible to 3-4% of patients with disabilities and were mostly provided to younger PSDs. The general population received more operative and endodontic therapies, and PSDs received more periodontal therapies. For quality assessments, the teeth of PSDs had a 9.74-15.07% refilling rate, which was higher than that of the general population (1.39-6.37%). Furthermore, the teeth of PSDs had a 32.03% unfinished endodontic rate, which was higher than that of the general population (21.42%). CONCLUSION: During 2010-2012, only 3-4% of patients with disabilities had access to dental services, mostly provided to younger PSDs. Teeth of PSDs had higher refilling rates and unfinished endodontic sessions than the general population. We suggest that a more comprehensive dental care system is necessary to improve the quantity and quality of dental services, especially in middle-aged and older PSDs.


Assuntos
Assistência Odontológica/estatística & dados numéricos , Pessoas com Deficiência/estatística & dados numéricos , Acessibilidade aos Serviços de Saúde/estatística & dados numéricos , Reembolso de Seguro de Saúde , Programas Nacionais de Saúde , Bases de Dados Factuais , Humanos , Taiwan
13.
PLoS One ; 10(11): e0143713, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26618362

RESUMO

Artificial bone grafting is widely used in current orthopedic surgery for bone defect problems. Unfortunately, surgeons remain unsatisfied with the current commercially available products. One of the major complaints is that these products cannot provide sufficient mechanical strength to support the human skeletal structure. In this study, we aimed to develop a bone scaffold with better mechanical property and good cell affinity by 3D printing (3DP) techniques. A self-developed 3D printer with laser-aided gelling (LAG) process was used to fabricate bioceramic scaffolds with inter-porous structures. To improve the mechanical property of the bioceramic parts after heating, CaCO3 was added to the silica ceramic slurry. CaCO3 was blended into a homogenous SiO2-sol dispersion at weight ratios varying from 0/100 to 5/95 to 9/91 (w/w). Bi-component CaCO3/SiO2-sol was prepared as a biocomposite for the 3DP scaffold. The well-mixed biocomposite was used to fabricate the bioceramic green part using the LAG method. The varied scaffolds were sintered at different temperatures ranging from 900 to 1500°C, and the mechanical property was subsequently analyzed. The scaffolds showed good property with the composite ratio of 5:95 CaCO3:SiO2 at a sintering temperature of 1300°C. The compressive strength was 47 MPa, and the porosity was 34%. The topography of the sintered 3DP bioceramic scaffold was examined by SEM, EDS and XRD. The silica bioceramic presented no cytotoxicity and good MG-63 osteoblast-like cell affinity, demonstrating good biocompatibility. Therefore, the new silica biocomposite is viable for fabricating 3DP bone bioceramics with improved mechanical property and good cell affinity.


Assuntos
Cerâmica/química , Porosidade , Impressão Tridimensional , Alicerces Teciduais/química , Animais , Regeneração Óssea , Carbonato de Cálcio/química , Adesão Celular , Linhagem Celular Tumoral , Humanos , Camundongos , Dióxido de Silício/química , Engenharia Tecidual/métodos
14.
J Formos Med Assoc ; 114(10): 929-35, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24661578

RESUMO

BACKGROUND/PURPOSE: Impacted third molars can be extracted by regular surgery or piezosurgery. The aim of this study was to compare clinical parameters and device-produced noise levels between regular surgery and piezosurgery for the extraction of impacted third molars. METHODS: Twenty patients (18 women and 2 men, 17-29 years of age) with bilateral symmetrical impacted mandibular or maxillary third molars of the same level were included in this randomized crossover clinical trial. The 40 impacted third molars were divided into a control group (n = 20), in which the third molar was extracted by regular surgery using a high-speed handpiece and an elevator, and an experimental group (n = 20), in which the third molar was extracted by piezosurgery using a high-speed handpiece and a piezotome. The clinical parameters were evaluated by a self-reported questionnaire. The noise levels produced by the high-speed handpiece and piezotome were measured and compared between the experimental and control groups. RESULTS: Patients in the experimental group had a better feeling about tooth extraction and force delivery during extraction and less facial swelling than patients in the control group. However, there were no significant differences in noise-related disturbance, extraction period, degree of facial swelling, pain score, pain duration, any noise levels produced by the devices under different circumstances during tooth extraction between the control and experimental groups. CONCLUSION: The piezosurgery device produced noise levels similar to or lower than those of the high-speed drilling device. However, piezosurgery provides advantages of increased patient comfort during extraction of impacted third molars.


Assuntos
Dente Serotino/cirurgia , Piezocirurgia/métodos , Complicações Pós-Operatórias , Extração Dentária/métodos , Dente Impactado/cirurgia , Adolescente , Adulto , Estudos Cross-Over , Feminino , Humanos , Masculino , Ruído , Duração da Cirurgia , Medição da Dor , Dor Pós-Operatória/etiologia , Autorrelato , Taiwan , Adulto Jovem
15.
J Formos Med Assoc ; 113(12): 956-65, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25438878

RESUMO

BACKGROUND/PURPOSE: Dental pulp stem cells (DPSCs) have been proposed as a promising source of stem cells in nerve regeneration due to their close embryonic origin and ease of harvest. The aim of this study was to evaluate the efficacy of dopaminergic and motor neuronal inductive media on transdifferentiation of human DPSCs (hDPSCs) into neuron-like cells. METHODS: Isolation, cultivation, and identification of hDPSCs were performed with morphological analyses and flow cytometry. The proliferation potential of DPSCs was evaluated with an XTT [(2,3-bis-(2-methoxy-4-nitro-5-sulfophenyl)-2H-tetrazolium-5-carboxanilide)] assay. Media for the induction of dopaminergic and spinal motor neuronal differentiation were prepared. The efficacy of neural induction was evaluated by detecting the expression of neuron cell-specific cell markers in DPSCs by immunocytochemistry and quantitative real-time reverse transcription polymerase chain reaction (RT-PCR). RESULTS: In the XTT assay, there was a 2.6- or 2-fold decrease in DPSCs cultured in dopaminergic or motor neuronal inductive media, respectively. The proportions of ßIII-tubulin (ßIII-tub), glial fibrillary acidic protein (GFAP), and oligodendrocyte (O1)-positive cells were significantly higher in DPSCs cultured in both neuronal inductive media compared with those cultured in control media. Furthermore, hDPSC-derived dopaminergic and spinal motor neuron cells after induction expressed a higher density of neuron cell markers than those before induction. CONCLUSION: These findings suggest that in response to the neuronal inductive stimuli, a greater proportion of DPSCs stop proliferation and acquire a phenotype resembling mature neurons. Such neural crest-derived adult DPSCs may provide an alternative stem cell source for therapy-based treatments of neuronal disorders and injury.


Assuntos
Células-Tronco Adultas/fisiologia , Polpa Dentária/citologia , Neurônios Dopaminérgicos/química , Antígenos de Diferenciação/análise , Diferenciação Celular , Células Cultivadas , Colina O-Acetiltransferase/análise , Meios de Cultivo Condicionados , Neurônios Dopaminérgicos/citologia , Neurônios Dopaminérgicos/enzimologia , Proteína Glial Fibrilar Ácida/análise , Humanos , Tubulina (Proteína)/análise , Tirosina 3-Mono-Oxigenase/análise
16.
J Clin Periodontol ; 40(1): 53-64, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23057701

RESUMO

AIM: Dentin hypersensitivity, caused by the exposure and patency of dentinal tubules, can affect patients' quality of life. The aim of this study was to undertake a systematic review and a network meta-analysis, comparing the effectiveness in resolving dentin hypersensitivity among different in-office desensitizing treatments. MATERIALS AND METHODS: A literature search was performed with electronic databases and by hand until December 2011. The included trials were divided into six treatment groups as placebo, physical occlusion, chemical occlusion, nerve desensitization, laser therapy and combined treatments. The treatment effects between groups were estimated with standardized mean differences by using a Bayesian network meta-analysis. RESULTS: Forty studies were included. The standardized mean difference between placebo and physical occlusion was -2.57 [95% credible interval (CI): -4.24 to -0.94]; placebo versus chemical occlusion was -2.33 (95% CI: -3.65 to -1.04); placebo versus nerve desensitization was -1.72 (95% CI: -4.00 to 0.52); placebo versus laser therapy was -2.81 (95% CI: -4.41 to -1.24); placebo versus combined treatment was -3.47 (95% CI: -5.99 to -0.96). The comparisons of the five active treatments showed no significant differences. CONCLUSIONS: The results from network meta-analysis showed that most active treatment options had significantly better treatment outcome than placebo.


Assuntos
Dessensibilizantes Dentinários/uso terapêutico , Permeabilidade da Dentina/efeitos dos fármacos , Sensibilidade da Dentina/terapia , Dessensibilizantes Dentinários/farmacologia , Humanos , Terapia a Laser , Ensaios Clínicos Controlados Aleatórios como Assunto
17.
Mater Sci Eng C Mater Biol Appl ; 32(7): 1859-1867, 2012 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-34062667

RESUMO

The study describes the sol-gel synthesis of a new dental retrograde filling material partial stabilized cement (PSC)-gypsum by adding different weight percentage of gypsum (25% PSC+75% gypsum, 50% PSC+50% gypsum and 75% PSC+25% gypsum) to the PSC. The crystalline phase and hydration products of PSC-gypsum were characterized by X-ray diffraction (XRD) and scanning electron microscopy (SEM) analysis. The handling properties such as setting time, viscosity, tensile strength, porosity and pH, were also studied. The XRD and microstructure analysis demonstrated the formation of hydroxyapatite and removal of calcium dihydrate during its immersion in simulated body fluid (SBF) on day 10 for 75% PSC+25% gypsum. The developed PSC-gypsum not only improved the setting time but also greatly reduced the viscosity, which is very essential for endodontic surgery. The cytotoxic and cell proliferation studies indicated that the synthesized material is highly biocompatible. The increased alkaline pH of the PSC-gypsum also had a remarkable antibacterial activity.

18.
Dent Mater J ; 30(6): 941-7, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-22123021

RESUMO

The purpose of this study was to evaluate influence of etching ability of one-step self-etch adhesives on bonding to non-carious cervical sclerotic lesion. Forty-eight human maxillary premolars with and without natural non-carious cervical sclerotic lesions at buccal surfaces were used in this study. Artificial wedge-shaped lesions were prepared in sound premolars. All lesions were bonded with Bond Force (BF; pH=2.3) or G-Bond Plus (GBA; pH=1.5) according to the manufacturers' instructions. After water storage for 24 hours at 37°C, bonded specimens were subjected to microtensile bond test to measure bond strength to the gingival wall in each lesion. The µTBS of BF to the natural lesion was significantly lower than that of artificial lesion (p<0.05), while for GBA, there is no significant difference (p>0.05). There was no difference in µTBS to artificial lesion between these two adhesives, however in case of non-carious cervical sclerotic lesion, the µTBS of GBA was statistically higher than that of BF.


Assuntos
Condicionamento Ácido do Dente , Resinas Compostas/química , Colagem Dentária/métodos , Cimentos Dentários/química , Análise do Estresse Dentário , Metacrilatos/química , Cimentos de Resina/química , Resistência à Tração , Dente Pré-Molar , Dentina Secundária/metabolismo , Humanos , Camada de Esfregaço , Propriedades de Superfície , Colo do Dente/metabolismo
19.
Dent Mater J ; 26(4): 467-73, 2007 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-17886448

RESUMO

By means of X-ray photoelectron spectroscopy (XPS) and differential scanning calorimetry (DSC), this study set out to investigate the application of plasma immersion ion implantation (PIII) for the surface modification of ProTaper NiTi rotary instruments. This study was undertaken because the PIII method was perceived to have the potential of developing into a standard surface modification technique that improves clinical quality and outcome. Specimens received nitrogen ion or nitrogen plus argon ion implantation. XPS analyses with and without argon ion etching were obtained for all specimens. In addition, DSC analysis was performed to investigate the phase transformation behavior of the bulk material. Results indicated that the surfaces of NiTi instruments were successfully modified by nitrogen PIII, whereby a light golden TiN layer was yielded. Moreover, the PIII technique did not alter the superelastic character of NiTi instruments because it was carried out at near-room temperature. We thus concluded that nitrogen PIII is a promising surface modification technique to improve the surface characteristics of NiTi rotary instruments.


Assuntos
Materiais Biocompatíveis/química , Níquel/química , Preparo de Canal Radicular/instrumentação , Titânio/química , Argônio , Varredura Diferencial de Calorimetria/métodos , Temperatura Alta , Rotação , Espectrometria por Raios X/métodos , Propriedades de Superfície
20.
Artigo em Inglês | MEDLINE | ID: mdl-17449287

RESUMO

The cementodentinal tear is rarely detected by noninvasive procedures owing to its clinical picture simulating a root fracture or a periodontal or endodontic lesion. We present a case of complex cementodentinal tears in a 79-year-old woman who presented a repeated swelling at the labial mucosa of the left maxillary central incisor for 6 months. Periapical radiographs demonstrated a vertical radiolucent fracture line extending from the root apex along the mesial aspect of the root to near the middle portion of the root of the left maxillary central incisor. Because endodontic re-treatment failed to cure the disease, periapical surgery was performed, and 2 fractured U-shaped root fragments around the apical root surface were removed. Histologic examination showed that the 2 fractured root fragments were composed mainly of the dentin covered by a thin layer of the cementum and overlying periodontal ligament tissue, suggesting cementodentinal tears. A swelling recurred 8 months after the initial operation. Therefore, a second periapical surgery was performed. Although no obvious fracture line was observed around the root surface, the second surgery did not cure the disease, either. A persistent small swelling was noted at the alveolar mucosa of the affected tooth during the follow-up. We conclude that although a cementodentinal tear can be detected by a careful radiographic examination, its clinical outcome is not predictable by surgical removal only.


Assuntos
Incisivo/patologia , Periodontite Periapical/etiologia , Ápice Dentário/lesões , Fraturas dos Dentes/complicações , Idoso , Apicectomia , Cemento Dentário/lesões , Fístula Dentária/etiologia , Fístula Dentária/cirurgia , Dentina/lesões , Feminino , Humanos , Maxila , Periodontite Periapical/cirurgia , Fraturas dos Dentes/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA