Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
ACS Nano ; 17(24): 24919-24935, 2023 Dec 26.
Artigo em Inglês | MEDLINE | ID: mdl-38051272

RESUMO

Boron nitride (BN) nanomaterials have drawn a lot of interest in the material science community. However, extensive research is still needed to thoroughly analyze their safety profiles. Herein, we investigated the pulmonary impact and clearance of two-dimensional hexagonal boron nitride (h-BN) nanosheets and boron nitride nanotubes (BNNTs) in mice. Animals were exposed by single oropharyngeal aspiration to h-BN or BNNTs. On days 1, 7, and 28, bronchoalveolar lavage (BAL) fluids and lungs were collected. On one hand, adverse effects on lungs were evaluated using various approaches (e.g., immune response, histopathology, tissue remodeling, and genotoxicity). On the other hand, material deposition and clearance from the lungs were assessed. Two-dimensional h-BN did not cause any significant immune response or lung damage, although the presence of materials was confirmed by Raman spectroscopy. In addition, the low aspect ratio h-BN nanosheets were internalized rapidly by phagocytic cells present in alveoli, resulting in efficient clearance from the lungs. In contrast, high aspect ratio BNNTs caused a strong and long-lasting inflammatory response, characterized by sustained inflammation up to 28 days after exposure and the activation of both innate and adaptive immunity. Moreover, the presence of granulomatous structures and an indication of ongoing fibrosis as well as DNA damage in the lung parenchyma were evidenced with these materials. Concurrently, BNNTs were identified in lung sections for up to 28 days, suggesting long-term biopersistence, as previously demonstrated for other high aspect ratio nanomaterials with poor lung clearance such as multiwalled carbon nanotubes (MWCNTs). Overall, we reveal the safer toxicological profile of BN-based two-dimensional nanosheets in comparison to their nanotube counterparts. We also report strong similarities between BNNTs and MWCNTs in lung response, emphasizing their high aspect ratio as a major driver of their toxicity.


Assuntos
Nanoestruturas , Nanotubos de Carbono , Camundongos , Animais , Nanotubos de Carbono/toxicidade , Nanoestruturas/toxicidade , Pulmão/patologia , Compostos de Boro/toxicidade , Compostos de Boro/química
2.
NanoImpact ; 29: 100451, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36626980

RESUMO

MoS2 has been increasingly used in place of graphene as a flexible and multifunctional 2D material in many biomedical applications such as cancer detection and drug delivery, which makes it crucial to evaluate downstream compatibility in human immune cells. Molybdenum is a component of stainless-steel stent implants and has previously been implicated in stent hypersensitivity. In view of this, it is important to ascertain the effect of MoS2 on allergy-relevant cells. Basophils are a less commonly used immune cell type. Unlike mast cells, basophils can be easily derived from primary human blood and can act as a sentinel for allergy. However, merely testing any one type of MoS2 in basophils could result in different biological results. We thus decided to compare 2D MoS2 from the two companies BeDimensional© (BD) and Biograph Solutions (BS), manufactured with two different but commonly exploited methods (BD, deoxycholate surfactant in a high-pressure liquid exfoliation, and BS using glycine in ball-milling exfoliation) to elucidate immunological end-points common to both MoS2 and to demonstrate the need for biological verification for end-users who may require a change of supplier. We report higher histamine production in human basophils with MoS2. No effects on either surface basophil activation markers CD63 and CD203c or reactive oxygen species (ROS) production and cell viability were observed. However, different cytokine production patterns were evidenced. IL-6 and IL-1ß but not TNF and GM-CSF were increased for both MoS2. BS-MoS2 increased IL-4, while BD-MoS2 decreased IL-4 and increased IL-13. Molybdate ion itself only increased IL-1ß and IL-4. Deoxycholate surfactant decreased viability at 18 h and increased ROS upon basophil activation. Therefore, these results demonstrate the safety of MoS2 in human basophils in general and highlight the importance of considering manufacturer additives and variability when selecting and investigating 2D materials such as MoS2.


Assuntos
Basófilos , Hipersensibilidade , Humanos , Molibdênio/metabolismo , Interleucina-4/metabolismo , Espécies Reativas de Oxigênio/metabolismo , Hipersensibilidade/metabolismo , Ácido Desoxicólico/metabolismo
3.
J Environ Sci Health B ; 56(4): 333-356, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33760696

RESUMO

With wider use of graphene-based materials and other two-dimensional (2 D) materials in various fields, including electronics, composites, biomedicine, etc., 2 D materials can trigger undesired effects at cellular, tissue and organ level. Macrophages can be found in many organs. They are one of the most important cells in the immune system and they are relevant in the study of nanomaterials as they phagocytose them. Nanomaterials have multi-faceted effects on phagocytic immune cells like macrophages, showing signs of inflammation in the form of pro-inflammatory cytokine or reactive oxidation species production, or upregulation of activation markers due to the presence of these foreign bodies. This review is catered to researchers interested in the potential impact and toxicity of 2 D materials, particularly in macrophages, focusing on few-layer graphene, graphene oxide, graphene quantum dots, as well as other promising 2 D materials containing molybdenum, manganese, boron, phosphorus and tungsten. We describe applications relevant to the growing area of 2 D materials research, and the possible risks of ions and molecules used in the production of these promising 2 D materials, or those produced by the degradation and dissolution of 2 D materials.


Assuntos
Macrófagos/efeitos dos fármacos , Nanoestruturas/química , Nanoestruturas/toxicidade , Animais , Citocinas/metabolismo , Grafite/química , Grafite/toxicidade , Humanos , Macrófagos/patologia , Macrófagos/fisiologia , Fósforo/química , Pontos Quânticos/química , Pontos Quânticos/toxicidade
4.
Small ; 16(35): e2002194, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32743979

RESUMO

Graphene and other 2D materials, such as molybdenum disulfide, have been increasingly used in electronics, composites, and biomedicine. In particular, MoS2 and graphene hybrids have attracted a great interest for applications in the biomedical research, therefore stimulating a pertinent investigation on their safety in immune cells like macrophages, which commonly engulf these materials. In this study, M1 and M2 macrophage viability and activation are mainly found to be unaffected by few-layer graphene (FLG) and MoS2 at doses up to 50 µg mL-1 . The uptake of both materials is confirmed by transmission electron microscopy, inductively coupled plasma mass spectrometry, and inductively coupled plasma atomic emission spectroscopy. Notably, both 2D materials increase the secretion of inflammatory cytokines in M1 macrophages. At the highest dose, FLG decreases CD206 expression while MoS2 decreases CD80 expression. CathB and CathL gene expressions are dose-dependently increased by both materials. Despite a minimal impact on the autophagic pathway, FLG is found to increase the expression of Atg5 and autophagic flux, as observed by Western blotting of LC3-II, in M1 macrophages. Overall, FLG and MoS2 are of little toxicity in human macrophages even though they are found to trigger cell stress and inflammatory responses.


Assuntos
Grafite , Molibdênio , Dissulfetos , Proteínas Filagrinas , Grafite/toxicidade , Humanos , Macrófagos , Molibdênio/toxicidade
6.
Artigo em Inglês | MEDLINE | ID: mdl-25570244

RESUMO

Ptosis of the eyelids is a common condition with a myriad of causes. Its management depends on the underlying cause, which can be challenging to diagnose in some cases. Current diagnosis methods include serum antibodies, tensilon test, and electromyography (EMG). Each has its own set of limitations such as invasiveness and lack of sensitivity. To overcome these limitations, we have developed a Portable Realtime Infrared Lids, Iris and Blink (PRILIB) monitoring system, with a long-term goal to improve clinical diagnosis of ptosis. In this paper, we present the algorithms to detect and analyze eye parameters and report experimental results. From experiments conducted on normal volunteers and myasthenic patients, we found 1. Partial blinks happen when Ocular Myasthenia Gravis (OMG) patients are tired or engaged in an activity; 2. Blink rate is significantly higher for OMG patients due to failure to blink fully; 3. There are noticeably more fluctuations of palpebral aperture of OMG patients due to rising and falling of the eyelid height. These experimental findings suggest new diagnostic features for OMG patients and have implications for disease management.


Assuntos
Miastenia Gravis/diagnóstico , Piscadela , Estudos de Casos e Controles , Eletromiografia , Movimentos Oculares , Pálpebras/fisiopatologia , Humanos , Gravação em Vídeo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA