1.
J Chin Med Assoc ; 77(4): 209-12, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24560543

RESUMO

Characteristic signs of malignant hyperthermia (MH) include unexplained tachycardia, increased end-tidal carbon dioxide (Etco2) concentration, metabolic and respiratory acidosis, and an increase in body temperature above 38.8°C. We present the case of a patient with highly probable MH. In addition to sinus tachycardia and metabolic and respiratory acidosis, this patient also had a negative arterial to Etco2 gradient and an increased requirement for minute ventilation to maintain a normal Etco2 concentration, with signs of increased CO2 production. Despite these signs of MH, the patient's rectal temperature monitoring equipment did not show an increase in temperature, although the temperature measured in the mouth was increased. This case illustrates the unreliability of measuring rectal temperature as a means of reflecting body temperature during MH and the usefulness of increased CO2 production signs in helping to diagnose MH.


Assuntos
Dióxido de Carbono/análise , Hipertermia Maligna/diagnóstico , Idoso , Artérias , Temperatura Corporal , Capnografia , Dióxido de Carbono/sangue , Feminino , Humanos , Hipertermia Maligna/fisiopatologia , Volume de Ventilação Pulmonar
2.
Liver Transpl ; 18(10): 1254-8, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-22730210

RESUMO

Plasma-containing products are given during the pre-anhepatic stage of liver transplant surgery to correct abnormal thromboelastogram (TEG) values and prevent blood loss due to coagulation defects. However, evidence suggests that abnormal TEG results do not always predict bleeding. We questioned what effect using higher TEG values to initiate treatment would have on blood loss. A single transfusion protocol was used for all patients who underwent liver transplantation between 2007 and 2010. Thirty-eight patients received coagulation products when standard TEG cutoff values were exceeded, whereas another 39 patients received coagulation products when the TEG values were 35% greater than normal. The results of postoperative coagulation tests for total blood loss and the use of blood products were compared for the 2 groups. When the critical TEG values for transfusion were higher, significantly fewer units of fresh frozen plasma (5.58 ± 6.49 versus 11.53 ± 6.66 U) and pheresis platelets (1.84 ± 1.33 versus 3.55 ± 1.43 U) were used. There were no differences in blood loss or postoperative blood product use. In conclusion, the use of higher critical TEG values to initiate the transfusion of plasma-containing products is not associated with increased blood loss. Further testing is necessary to identify what TEG value predicts bleeding due to a deficit in coagulation factors.


Assuntos
Perda Sanguínea Cirúrgica/prevenção & controle , Transfusão de Sangue , Falência Renal Crônica/cirurgia , Transplante de Fígado , Tromboelastografia/métodos , Adulto , Coagulação Sanguínea , Fatores de Coagulação Sanguínea , Testes de Coagulação Sanguínea , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Plasma , Transfusão de Plaquetas , Valor Preditivo dos Testes , Estudos Retrospectivos , Tromboelastografia/normas