Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
BMC Pediatr ; 24(1): 277, 2024 Apr 27.
Artigo em Inglês | MEDLINE | ID: mdl-38678190

RESUMO

OBJECTIVE: This study aimed to compare the efficacy of neurally adjusted ventilatory assist (NAVA) to synchronized intermittent mandatory ventilation (SIMV) in preterm infants requiring mechanical ventilation after patent ductus arteriosus (PDA) ligation. METHODS: A retrospective analysis was conducted on intubated preterm infants who underwent PDA ligation at our hospital from July 2021 to January 2023. Infants were divided into NAVA or SIMV groups based on the ventilation mode after surgery. RESULTS: Fifty preterm infants were included. During treatment, peak inspiratory pressure (PIP) and mean airway pressure (MAP) were lower with NAVA compared to SIMV (PIP: 19.1 ± 2.9 vs. 22.4 ± 3.6 cmH2O, P < 0.001; MAP: 9.1 ± 1.8 vs. 10.9 ± 2.7 cmH2O, P = 0.002). PaO2 and PaO2/FiO2 were higher with NAVA (PaO2: 94.0 ± 11.7 vs. 84.8 ± 15.8 mmHg, P = 0.031; PaO2/FiO2: 267 [220-322] vs. 232 [186-290] mmHg, P = 0.025). Less sedation was required with NAVA (midazolam: 1.5 ± 0.5 vs. 1.1 ± 0.3 µg/kg/min, P < 0.001). CONCLUSION: Compared to SIMV, early use of NAVA post PDA ligation in preterm infants was associated with decreased PIP and MAP. Early NAVA was also associated with reduced sedation needs and improved oxygenation. However, further studies are warranted to quantify the benefits of NAVA ventilation.


Assuntos
Permeabilidade do Canal Arterial , Recém-Nascido Prematuro , Suporte Ventilatório Interativo , Ventilação com Pressão Positiva Intermitente , Humanos , Permeabilidade do Canal Arterial/cirurgia , Permeabilidade do Canal Arterial/terapia , Estudos Retrospectivos , Recém-Nascido , Masculino , Feminino , Ligadura/métodos , Suporte Ventilatório Interativo/métodos , Ventilação com Pressão Positiva Intermitente/métodos , Síndrome do Desconforto Respiratório do Recém-Nascido/terapia
2.
Talanta ; 258: 124414, 2023 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-36889191

RESUMO

This work for the first time reports on a simple and rapid colorimetric immunoassay with rapid coordination of ascorbic acid 2-phosphate (AAP) and iron (III) for determination of carcinoembryonic antigen (CEA, used as a model) by using Fe2O3 nanoparticle based-chromogenic substrate system. The signal was produced rapidly (1 min) from the coordination of AAP and iron (III) with color development of colorless to brown. TD-DFT calculation methods were employed to simulate the UV-Vis spectra of AAP-Fe2+ and AAP-Fe3+ complexes. Moreover, Fe2O3 nanoparticle could be dissolved with the aid of acid, thereby releasing free iron (III). Herein, a sandwich-type immunoassay was established based on Fe2O3 nanoparticle as labels. As target CEA concentration increased, the number of Fe2O3 labelled-antibodies (bound specifically) increased, resulting in loading more Fe2O3 nanoparticle on platform. The absorbance increased as the number of free iron (III), derived from Fe2O3 nanoparticle, increased. So, the absorbance of reaction solution is positively correlated with antigen concentration. Under optimal conditions, the current results showed good performance for CEA detection in the range 0.02-10.0 ng/mL with a detection limit of 11 pg/mL. Moreover, the repeatability, stability, and selectivity of the colorimetric immunoassay were also acceptable.


Assuntos
Antígeno Carcinoembrionário , Nanopartículas , Antígeno Carcinoembrionário/química , Ferro , Compostos Cromogênicos , Colorimetria/métodos , Imunoensaio/métodos , Limite de Detecção
3.
Heart Surg Forum ; 25(5): E709-E714, 2022 Sep 28.
Artigo em Inglês | MEDLINE | ID: mdl-36317914

RESUMO

OBJECTIVE: This study aimed to evaluate the efficacy and safety of high-frequency oscillation ventilation combined with volume guarantee (HFOV-VG) in preterm infants with acute hypoxemic respiratory failure (AHRF) after patent ductus arteriosus ligation. METHODS: We retrospectively analyzed the clinical data of 41 preterm infants, who were ventilated for AHRF after patent ductus arteriosus ligation between January 2020 and January 2022. HFOV alone was used in 20 of the 41 infants, whereas HFOV-VG was used in the other 21 infants. RESULTS: There was no statistically significant difference in the demographic information and baseline characteristics of preterm infants included in the study. The average frequency tidal volume (VThf) of the HFOV-VG group was lower than that of the HFOV group (2.6 ± 0.6 mL versus 1.9 ± 0.3 mL, P < .001). In addition, the incidence of hypocapnia and hypercapnia in infants supported with HFOV-VG was significantly lower (15 versus 8, P < .001; 12 versus 5, P < .001). Furthermore, the duration of invasive ventilation in the HFOV-VG group also was lower than in the HFOV group (3.7 ± 1.2 days versus 2.1 ± 1.0 days, P < .01). CONCLUSION: Compared with HFOV alone, HFOV-VG decreases VThf levels and reduces the incidence of hypercapnia and hypocapnia in preterm infants with acute hypoxic respiratory failure after patent ductus arteriosus ligation.


Assuntos
Permeabilidade do Canal Arterial , Ventilação de Alta Frequência , Síndrome do Desconforto Respiratório do Recém-Nascido , Síndrome do Desconforto Respiratório , Insuficiência Respiratória , Lactente , Recém-Nascido , Humanos , Recém-Nascido Prematuro , Hipocapnia , Estudos Retrospectivos , Hipercapnia
4.
PLoS One ; 14(5): e0217357, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31136604

RESUMO

Back pain commonly arises from intervertebral disc (IVD) damage including annulus fibrosus (AF) defects and nucleus pulposus (NP) loss. Poor IVD healing motivates developing tissue engineering repair strategies. This study evaluated a composite injectable IVD biomaterial repair strategy using carboxymethylcellulose-methylcellulose (CMC-MC) and genipin-crosslinked fibrin (FibGen) that mimic NP and AF properties, respectively. Bovine ex vivo caudal IVDs were evaluated in cyclic compression-tension, torsion, and compression-to-failure tests to determine IVD biomechanical properties, height loss, and herniation risk following experimentally-induced severe herniation injury and discectomy (4 mm biopsy defect with 20% NP removed). FibGen with and without CMC-MC had failure strength similar to discectomy injury suggesting no increased risk compared to surgical procedures, yet no biomaterials improved axial or torsional biomechanical properties suggesting they were incapable of adequately restoring AF tension. FibGen had the largest failure strength and was further evaluated in additional discectomy injury models with varying AF defect types (2 mm biopsy, 4 mm cruciate, 4 mm biopsy) and NP removal volume (0%, 20%). All simulated discectomy defects significantly compromised failure strength and biomechanical properties. The 0% NP removal group had mean values of axial biomechanical properties closer to intact levels than defects with 20% NP removed but they were not statistically different and 0% NP removal also decreased failure strength. FibGen with and without CMC-MC failed at super-physiological stress levels above simulated discectomy suggesting repair with these tissue engineered biomaterials may perform better than discectomy alone, although restored biomechanical function may require additional healing with the potential application of these biomaterials as sealants and cell/drug delivery carriers.


Assuntos
Materiais Biocompatíveis/química , Deslocamento do Disco Intervertebral/fisiopatologia , Deslocamento do Disco Intervertebral/terapia , Animais , Anel Fibroso/lesões , Materiais Biocompatíveis/administração & dosagem , Fenômenos Biomecânicos , Carboximetilcelulose Sódica , Bovinos , Reagentes de Ligações Cruzadas , Modelos Animais de Doenças , Discotomia , Fibrina , Hidrogéis , Técnicas In Vitro , Injeções Espinhais , Iridoides , Teste de Materiais , Metilcelulose , Núcleo Pulposo/lesões
5.
J Biomed Mater Res A ; 104(1): 165-77, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26256108

RESUMO

Engineered constructs represent a promising treatment for replacement of nucleus pulposus (NP) tissue. Recently, photocrosslinked hydrogels comprised of methacrylated carboxymethylcellulose (CMC) were shown to support chondrogenic differentiation of encapsulated human mesenchymal stem cells (hMSCs) and promote accumulation of NP-like extracellular matrix (ECM). The objective of this study was to investigate the influence of CMC crosslinking density, by varying macromer concentration and modification (i.e., methacrylation) percentage, on NP-like differentiation of encapsulated hMSCs. Constructs of lower macromer concentration (2%, w/v) exhibited significantly greater collagen II accumulation, more homogeneous distribution of ECM macromolecules, and a temporal increase in mechanical properties compared to hydrogels of higher macromer concentration (4%, w/v). Constructs of higher modification percentage (25%) gave rise to significantly elevated collagen II content and the formation of cell clusters within the matrix relative to samples of lower modification percentage (10% and 15%). These differences in functional ECM accumulation and distribution are likely attributed to the distinct crosslinked network structures of the various hydrogel formulations. Overall, CMC constructs of lower macromer concentration and modification percentage were most promising as scaffolds for NP tissue engineering based on functional ECM assembly. Optimization of such hydrogel fabrication parameters may lead to the development of clinically relevant tissue-engineered NP replacements.


Assuntos
Carboximetilcelulose Sódica/farmacologia , Reagentes de Ligações Cruzadas/farmacologia , Matriz Extracelular/metabolismo , Hidrogéis/farmacologia , Disco Intervertebral/metabolismo , Células-Tronco Mesenquimais/citologia , Módulo de Elasticidade/efeitos dos fármacos , Matriz Extracelular/efeitos dos fármacos , Humanos , Imuno-Histoquímica , Células-Tronco Mesenquimais/efeitos dos fármacos , Soluções , Viscosidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA