Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J Clin Med ; 13(12)2024 Jun 11.
Artigo em Inglês | MEDLINE | ID: mdl-38929945

RESUMO

Objectives: Cervical disc herniation (CDH) leads to pain, numbness, and potential disability. Percutaneous endoscopic cervical discectomy (PECD) offers an anterior or posterior approach. This study aims to compare postoperative disc height and angle changes one year after PECD, considering both approaches. Methods: We retrospectively reviewed the data from patients with CDH who underwent PECD from October 2017 to July 2022. Cervical disc height was measured using the preoperative and one-year postoperative magnetic resonance imaging (MRI) examinations. Lordotic angle (LA), global alignment angle (GAA), segmental alignment angle (SAA), and slippage distance (SD) at the surgical level were measured on radiographs in the neutral, flexion, and extension positions. Results: Thirty-eight patients who underwent posterior PECD (PPECD) and five patients who underwent anterior PECD (APECD) were included in the evaluation. The mean age of the patients was 47.4 years (range: 29-69 years). There was a significant difference in the preoperative and one-year postoperative GAA and SAA in extension in the PPECD group (p = 0.003 and 0.031, respectively). The mean decreased disc height one-year postoperative was 1.30 mm in the APECD group and 0.3 mm in the PPECD group by MRI. A significant disc height decrease was observed in the APECD group (p < 0.001). Conclusions: Treating CDH with PPECD or APECD is feasible, as it can relieve symptoms and reduce disability. Stability remained unaffected during the first year after surgery, even though there was an increase in angulation during extension. Despite a significant decrease in disc space following APECD, patients reported significant symptom improvement and no new symptoms.

2.
J Neurosurg Spine ; 40(6): 773-781, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38518295

RESUMO

OBJECTIVE: This retrospective study was designed to evaluate the incidence and predisposing factors of heterotopic ossification (HO) after cervical disc arthroplasty (CDA) with a specific implant at 1 and 2 levels, and to investigate the biomechanical effects related to HO. The study goal was to identify ways to reduce the likelihood of HO formation after surgery. METHODS: The study included patients who underwent only 1- or 2-level CDA with the Baguera C disc between November 2014 and December 2021 at a single medical center. All patients were operated on by the same neurosurgeon. The surgical indication included 1-level or 2-level disc herniation between C3 and C7 with radiculopathy, myelopathy, or both, with minimal spondylosis. The various factors were assessed by evaluating plain radiographs and cervical CT scans. The presence of HO was evaluated at different intervals postsurgery, and HO severity was graded using the McAfee classification. RESULTS: Of 107 patients who underwent CDA, 47 (43.9%) had HO at 63 of 171 levels (36.8%). Most cases with HO were grade 1, and no grade 4 was observed. Statistically significant risk factors for HO were the length of endplate coverage ratio and inferior anterior residual exposed endplate (AREE); sex, age, implant height and width, shell angle, and pre- and postoperative functional spinal unit (FSU) angle were not significant. More AREE and greater kyphotic postoperative FSU angle in the flexion position were significant factors differentiating HO grades 0 and 1 from grades 2 and 3. Furthermore, the non-HO group showed a trend of higher range of motion at any postoperative time compared to the HO group, especially at 1 month after surgery. CONCLUSIONS: The HO incidence after CDA was correlated with the residual length of endplate coverage and inferior AREE. Additionally, the AREE and kyphotic postoperative FSU angle in the flexion position were associated with HO grade progression. Patients with HO also showed a trend of lower range of motion at 1 month after surgery. Using an adequately sized implant and encouraging neck motion may help prevent HO development and progression.


Assuntos
Vértebras Cervicais , Ossificação Heterotópica , Humanos , Ossificação Heterotópica/etiologia , Ossificação Heterotópica/epidemiologia , Ossificação Heterotópica/diagnóstico por imagem , Feminino , Masculino , Fatores de Risco , Vértebras Cervicais/cirurgia , Vértebras Cervicais/diagnóstico por imagem , Incidência , Pessoa de Meia-Idade , Estudos Retrospectivos , Adulto , Deslocamento do Disco Intervertebral/cirurgia , Substituição Total de Disco/efeitos adversos , Substituição Total de Disco/métodos , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Disco Intervertebral/cirurgia , Disco Intervertebral/diagnóstico por imagem , Idoso , Artroplastia/efeitos adversos , Artroplastia/métodos , Radiculopatia/cirurgia , Radiculopatia/etiologia , Radiculopatia/epidemiologia
3.
Int J Rheum Dis ; 26(10): 1996-2006, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37565304

RESUMO

AIM: An estimated 88% of rheumatoid arthritis (RA) patients experience various degrees of cervical spine involvement. The excessive movement of the atlantoaxial joint, which connects the occiput to the upper cervical spine, results in atlantoaxial instability (AAI). AAI stabilization is usually achieved by C1 lateral mass-to-C2 pedicle screw-rod fixation (LC1-PC2 fixation), which is technically challenging in RA patients who often show destructive changes in anatomical structures. This study aimed to analyze the clinical results and operative experiences of C1-C2 surgery, with emphasis on the advancement of image-guided surgery and augmented reality (AR) assisted navigation. METHODS: We presented our two decades of experience in the surgical management of AAI from April 2004 to November 2022. RESULTS: We have performed surgery on 67 patients with AAI, including 21 traumatic odontoid fractures, 20 degenerative osteoarthritis, 11 inflammatory diseases of RA, 5 congenital anomalies of the os odontoideum, 2 unknown etiologies, 2 movement disorders, 2 previous implant failures, 2 osteomyelitis, 1 ankylosing spondylitis, and 1 tumor. Beginning in 2007, we performed LC1-PC2 fixation under C-arm fluoroscopy. As part of the progress in spinal surgery, since 2011 we used surgical navigation from presurgical planning to intraoperative navigation, using the preoperative computed tomography (CT) -based image-guided BrainLab navigation system. In 2021, we began using intraoperative CT scan and microscope-based AR navigation. CONCLUSION: The technical complexities of C1-C2 surgery can be mitigated by CT-based image-guided surgery and microscope-based AR navigation, to improve accuracy in screw placement and overall clinical outcomes, particularly in RA patients with AAI.

4.
Medicine (Baltimore) ; 102(5): e32832, 2023 Feb 03.
Artigo em Inglês | MEDLINE | ID: mdl-36749265

RESUMO

The effect of spinal anatomical anomalies on the efficacy of percutaneous endoscopic lumbar discectomy (PELD) for disc herniation repair is unclear. This retrospective review aims to assess the safety and effectiveness of PELD for treating L5-S1 disc herniation with a range of characteristics and to determine the prevalence of lumbosacral transitional vertebrae (LSTV) anatomical anomalies to facilitate pre-surgical planning. From July 2005 to June 2019, 345 patients with L5-S1 disc herniations were treated with PELD. The primary outcome was 1-year postoperative visual analogue scale scores for low back and lower limb pain. The secondary outcomes included the surgical approach used, lumbosacral bony anomalies, presence of a ruptured disc or severely calcified disc, pediatric lumbar disc herniation, recurrent disc herniation management, and the long-term outcome. visual analogue scale scores for most patients were significantly improved after surgery. The prevalence of LSTVs was 4.05% (14/345 patients) in lumbar sacralization and 7.53% (26/345 patients) in sacral lumbarization. The prevalence of ruptured and severely calcified discs was 18.55% (64/345) and 5.79% (20/345), respectively. The prevalence of pediatric lumbar disc herniation was 2.02% (7/345). The recurrence rate was 4.34% (15/345). Two durotomy cases without sequelae and 8 cases of lower limb dysesthesia lasting longer than 3 months postoperatively were reported. PELD is safe and effective for treating L5-S1 disc herniation, including cases complicated by calcified lumbar disc herniation, disc rupture with migration, and the presence of LSTV. Appropriate imaging is essential to identify case-specific factors, including the prevalent LSTV anatomical anomalies, before surgery.


Assuntos
Discotomia Percutânea , Deslocamento do Disco Intervertebral , Humanos , Criança , Deslocamento do Disco Intervertebral/cirurgia , Discotomia Percutânea/métodos , Estudos Retrospectivos , Vértebras Lombares/cirurgia , Endoscopia/métodos , Região Lombossacral/cirurgia , Resultado do Tratamento
5.
Biomed Res Int ; 2023: 8010223, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36794256

RESUMO

Objectives: The objectives of this study were to identify the risk factors and incidence of anterior bone loss (ABL) after Baguera C cervical disc arthroplasty (CDA) and identify whether design differences in artificial discs affect ABL. Methods: In this retrospective radiological review of patients who underwent single-level Baguera C CDA in a medical center, the extent of ABL and the following radiological parameters were recorded: global and segmental alignment angle, lordotic angle (or functional spinal unit angle), shell angle, global range of motion (ROM), and ROM of the index level. ABL at the index level was grade 0-2. Grade 0 was defined as no remodeling, grade 1 as spur disappearance or mild change in body contour, and grade 2 as obvious bone regression with Baguera C Disc exposure. Results: Combining grade 1 and grade 2, ABL was found in 56 upper adjacent vertebrae and 52 lower adjacent vertebrae of the 77 patients. Only 18 patients (23.4%) had no ABL. Shell angle differed significantly between ABL grades of both the upper and lower adjacent level: 0.0° in grade 0 and 1 ABL vs. 2.0° in grade 2 ABL of the upper adjacent level (p < 0.05); and 0.0° in grade 0 and 1 ABL vs. 3.5° in grade 2 ABL of the lower adjacent level (p < 0.05). A female predominance of ABL was found. Hybrid surgery and artificial disc size were also related to ABL. Conclusions: ABL is more common in Baguera C Disc arthroplasty than Bryan Disc arthroplasty. Larger shell angle was related to ABL after CDA with Baguera C Discs, which may indicate that shell angle is pivotal in determining the incidence of ABL after CDA. Females had more ABL with Baguera C Disc arthroplasty; this might be related to shorter endplate lengths as well as a smaller endplate-implant mismatch.


Assuntos
Doenças Ósseas Metabólicas , Degeneração do Disco Intervertebral , Disco Intervertebral , Substituição Total de Disco , Humanos , Feminino , Masculino , Estudos Retrospectivos , Vértebras Cervicais/diagnóstico por imagem , Vértebras Cervicais/cirurgia , Artroplastia/efeitos adversos , Pescoço/cirurgia , Próteses e Implantes , Resultado do Tratamento , Degeneração do Disco Intervertebral/diagnóstico por imagem , Degeneração do Disco Intervertebral/cirurgia , Amplitude de Movimento Articular , Disco Intervertebral/diagnóstico por imagem , Disco Intervertebral/cirurgia , Substituição Total de Disco/efeitos adversos
6.
Int J Mol Sci ; 24(1)2022 Dec 20.
Artigo em Inglês | MEDLINE | ID: mdl-36613448

RESUMO

Gold nanoparticles (AuNPs) are well known to interact with cells, leading to different cell behaviors such as cell proliferation and differentiation capacity. Biocompatibility and biological functions enhanced by nanomedicine are the most concerning factors in clinical approaches. In the present research, AuNP solutions were prepared at concentrations of 1.25, 2.5, 5 and 10 ppm for biocompatibility investigations. Ultraviolet-visible spectroscopy was applied to identify the presence of AuNPs under the various concentrations. Dynamic Light Scattering assay was used for the characterization of the size of the AuNPs. The shape of the AuNPs was observed through a Scanning Electron Microscope. Afterward, the mesenchymal stem cells (MSCs) were treated with a differentiation concentration of AuNP solutions in order to measure the biocompatibility of the nanoparticles. Our results demonstrate that AuNPs at 1.25 and 2.5 ppm could significantly enhance MSC proliferation, decrease reactive oxygen species (ROS) generation and attenuate platelet/monocyte activation. Furthermore, the MSC morphology was observed in the presence of filopodia and lamellipodia while being incubated with 1.25 and 2.5 ppm AuNPs, indicating that the adhesion ability was enhanced by the nanoparticles. The expression of matrix metalloproteinase (MMP-2/9) in MSCs was found to be more highly expressed under 1.25 and 2.5 ppm AuNP treatment, relating to better cell migrating ability. Additionally, the cell apoptosis of MSCs investigated with Annexin-V/PI double staining assay and the Fluorescence Activated Cell Sorting (FACS) method demonstrated the lower population of apoptotic cells in 1.25 and 2.5 ppm AuNP treatments, as compared to high concentrations of AuNPs. Additionally, results from a Western blotting assay explored the possibility that the anti-apoptotic proteins Cyclin-D1 and Bcl-2 were remarkably expressed. Meanwhile, real-time PCR analysis demonstrated that the 1.25 and 2.5 ppm AuNP solutions induced a lower expression of inflammatory cytokines (TNF-α, IL-1ß, IFN-γ, IL-6 and IL-8). According to the tests performed on an animal model, AuNP 1.25 and 2.5 ppm treatments exhibited the better biocompatibility performance, including anti-inflammation and endothelialization. In brief, 1.25 and 2.5 ppm of AuNP solution was verified to strengthen the biological functions of MSCs, and thus suggests that AuNPs become the biocompatibility nanomedicine for regeneration research.


Assuntos
Células-Tronco Mesenquimais , Nanopartículas Metálicas , Animais , Ouro/farmacologia , Ouro/química , Nanopartículas Metálicas/química , Apoptose
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA