Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 30
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
BMC Ophthalmol ; 24(1): 51, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38302908

RESUMO

BACKGROUND: Artificial intelligence (AI) has the potential to increase the affordability and accessibility of eye disease screening, especially with the recent approval of AI-based diabetic retinopathy (DR) screening programs in several countries. METHODS: This study investigated the performance, feasibility, and user experience of a seamless hardware and software solution for screening chronic eye diseases in a real-world clinical environment in Germany. The solution integrated AI grading for DR, age-related macular degeneration (AMD), and glaucoma, along with specialist auditing and patient referral decision. The study comprised several components: (1) evaluating the entire system solution from recruitment to eye image capture and AI grading for DR, AMD, and glaucoma; (2) comparing specialist's grading results with AI grading results; (3) gathering user feedback on the solution. RESULTS: A total of 231 patients were recruited, and their consent forms were obtained. The sensitivity, specificity, and area under the curve for DR grading were 100.00%, 80.10%, and 90.00%, respectively. For AMD grading, the values were 90.91%, 78.79%, and 85.00%, and for glaucoma grading, the values were 93.26%, 76.76%, and 85.00%. The analysis of all false positive cases across the three diseases and their comparison with the final referral decisions revealed that only 17 patients were falsely referred among the 231 patients. The efficacy analysis of the system demonstrated the effectiveness of the AI grading process in the study's testing environment. Clinical staff involved in using the system provided positive feedback on the disease screening process, particularly praising the seamless workflow from patient registration to image transmission and obtaining the final result. Results from a questionnaire completed by 12 participants indicated that most found the system easy, quick, and highly satisfactory. The study also revealed room for improvement in the AMD model, suggesting the need to enhance its training data. Furthermore, the performance of the glaucoma model grading could be improved by incorporating additional measures such as intraocular pressure. CONCLUSIONS: The implementation of the AI-based approach for screening three chronic eye diseases proved effective in real-world settings, earning positive feedback on the usability of the integrated platform from both the screening staff and auditors. The auditing function has proven valuable for obtaining efficient second opinions from experts, pointing to its potential for enhancing remote screening capabilities. TRIAL REGISTRATION: Institutional Review Board of the Hamburg Medical Chamber (Ethik-Kommission der Ärztekammer Hamburg): 2021-10574-BO-ff.


Assuntos
Retinopatia Diabética , Glaucoma , Degeneração Macular , Humanos , Inteligência Artificial , Retinopatia Diabética/diagnóstico , Programas de Rastreamento/métodos , Software , Degeneração Macular/diagnóstico , Glaucoma/diagnóstico
2.
Expert Rev Cardiovasc Ther ; 17(12): 883-915, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31829751

RESUMO

Introduction: The revised Ghent nosology presents the classical features of Marfan syndrome. However, behind its familiar face, Marfan syndrome hides less well-known features.Areas covered: The German Marfan Organization listed unusual symptoms and clinical experts reviewed the literature on clinical features of Marfan syndrome not listed in the Ghent nosology. Thereby we identified the following features: (1) bicuspid aortic valve, mitral valve prolapse, pulmonary valve prolapse, tricuspid valve prolapse, (2) heart failure and cardiomyopathy, (3) supraventricular arrhythmia, ventricular arrhythmia, and abnormal repolarization, (4) spontaneous coronary artery dissection, anomalous coronary arteries, and atherosclerotic coronary artery disease, tortuosity-, aneurysm-, and dissection of large and medium-sized arteries, (5) restrictive lung disease, parenchymal lung disease, and airway disorders, (6) obstructive- and central sleep apnea, (7) liver and kidney cysts, biliary tract disease, diaphragmatic hernia, and adiposity, (8) premature labor, and urinary incontinence, (9) myopathy, reduced bone mineral density, and craniofacial manifestations, (10) atrophic scars, (11) caries, and craniomandibular dysfunction, (12) headache from migraine and spontaneous cerebrospinal fluid leakage, (13) cognitive dysfunction, schizophrenia, depression, fatigue, and pain, (14) and activated fibrinolysis, thrombin, platelets, acquired von Willebrand disease, and platelet dysfunction.Expert commentary: Future research, nosologies, and guidelines may consider less well-known features of Marfan syndrome.


Assuntos
Doenças Cardiovasculares/etiologia , Síndrome de Marfan/fisiopatologia , Osso e Ossos/patologia , Doenças Cardiovasculares/fisiopatologia , Humanos , Pulmão/fisiopatologia
3.
J Cataract Refract Surg ; 45(7): 952-958, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-31262484

RESUMO

PURPOSE: To investigate the prevalence of preoperative, intraoperative, and postoperative angle κ in hyperopic eyes and its effect on the refractive outcomes of excimer laser vision correction. SETTING: University Hospital Hamburg and Care Vision Refractive Centers, Germany. DESIGN: Retrospective multicenter study. METHODS: Hyperopic patients after laser in situ keratomileusis and before retreatment because of hyperopic regression were included. Three treatment groups were defined based on the magnitude of preoperative angle κ defined as low (<0.25 mm), moderate (0.25 to 0.50 mm), or high (>0.50 mm). RESULTS: The study analyzed 170 hyperopic eyes of 112 patients (mean age 29.8 years ± 10.04 [SD], range 21 to 62 years). The preoperative angle κ was low, moderate, or high in 23, 49, and 98 cases, respectively. In eyes with a preoperative angle κ of 0.25 mm or more, changes in the x-axes and y-axes of angle κ and its magnitude were statistically significant (P < .05) between preoperative and intraoperative measurements. In these eyes, intraoperative angle κ (offset) was statistically significantly smaller (P < .05), and Purkinje images were statistically significantly more caudal (P < .001). Treatment predictability was independent from using preoperative or intraoperative angle κ, and there were no statistically significant differences in efficacy or safety. CONCLUSIONS: A preoperative magnitude of angle κ as high as 0.50 mm or higher was present in more than 50% of regressed hyperopic eyes. Measuring angle κ preoperatively did not reflect its real-time intraoperative magnitude. Using the preoperatively larger angle κ as an intraoperative offset might result in a too nasally centered ablation that causes topographic and optical drawbacks; therefore, centering the ablation based on the intraoperative measured offset is recommended.


Assuntos
Astigmatismo/cirurgia , Córnea/cirurgia , Hiperopia/cirurgia , Ceratomileuse Assistida por Excimer Laser In Situ/métodos , Refração Ocular/fisiologia , Acuidade Visual , Adulto , Astigmatismo/fisiopatologia , Córnea/patologia , Topografia da Córnea , Feminino , Humanos , Hiperopia/fisiopatologia , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento , Adulto Jovem
4.
J Refract Surg ; 34(12): 840-847, 2018 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-30540367

RESUMO

PURPOSE: To analyze the potential benefit of the newly developed Tomography and Biomechanical Index (TBI) for early keratoconus screening. METHODS: In this retrospective study, the discriminatory power of the corneal tomography Belin/Ambrósio Enhanced Ectasia Display (BAD-D) index and the newly developed Corvis Biomechanical Index (CBI) and TBI to differentiate between normal eyes, manifest keratoconus eyes (KCE), very asymmetric keratoconus eyes with ectasia (VAE-E), and their fellow eyes with either regular topography (VAE-NT) or regular topography and tomography (VAE-NTT) were analyzed by applying the t test (for normal distribution), Wilcoxon matched-pairs test (if not normally distributed), and receiver operating characteristic curve (ROC). The DeLong test was used to compare the area under the ROC (AUROC). Further, the cut-offs of the analyzed indices presented in a study by Ambrósio et al. from 2017 were applied in the study population to enable a cross-validation in an independent study population. RESULTS: All indices demonstrated a high discriminative power when comparing normal and advanced keratoconus, which decreased when comparing normal and VAE-NT eyes and further when analyzing normal versus VAE-NTT eyes. The difference between the AUROCs reached a statistically significant level when comparing TBI versus BAD-D analyzing normal versus all included keratoconic eyes (P = .02). The TBI presented with the highest AUROCs throughout all conducted analyses when comparing different keratoconus stages, although not reaching a statistically significant level. Applying the cut-offs presented by Ambrósio et al. to differentiate between normal and VAE-NT in the study population, the accuracy was reproducible (accuracy in our study population with an optimized TBI cut-off: 0.72, with the cut-off defined by Ambrósio et al. 0.67). CONCLUSIONS: The TBI enables karatoconus screening in topographical and tomographical regular keratoconic eyes. To further improve the screening accuray, prospective studies should be conducted. [J Refract Surg. 2018;34(12):840-847.].


Assuntos
Córnea/fisiopatologia , Elasticidade/fisiologia , Ceratocone/diagnóstico por imagem , Ceratocone/fisiopatologia , Adulto , Fenômenos Biomecânicos , Paquimetria Corneana , Topografia da Córnea , Feminino , Humanos , Masculino , Curva ROC , Estudos Retrospectivos , Tomografia
6.
J Cataract Refract Surg ; 43(11): 1436-1442, 2017 11.
Artigo em Inglês | MEDLINE | ID: mdl-29223233

RESUMO

PURPOSE: To evaluate the efficacy, predictability, and safety of laser in situ keratomileusis (LASIK) retreatment in eyes with hyperopia. SETTING: Multicenter refractive surgery centers and University Hospital, Germany. DESIGN: Retrospective case series. METHODS: This multicenter study included hyperopic patients with a preoperative difference between cycloplegic and manifest refraction of 1.00 diopter (D) or less who had LASIK retreatment based on manifest refraction. The refractive outcome was analyzed according to standard graphs for reporting the efficacy, predictability, and safety of refractive surgery. RESULTS: One hundred thirteen eyes of 113 consecutive hyperopic patients were enrolled. Efficacy (P < .001) and safety (P = .004) were statistically significantly improved by retreatment without being negatively influenced by preoperative manifest spherical equivalent (SE), manifest cylinder, or keratometry. In cases still showing a trend toward undercorrection, retreatment resulted in 88 eyes (78.0%) being within ±0.50 D of the attempted correction. The optical zone (OZ) diameter of the retreatment did not correlate with efficacy, predictability, or safety. CONCLUSIONS: Retreatment after hyperopic LASIK resulted in high efficacy, predictability, and safety outcomes. The efficacy and safety of the retreatment were not affected by preoperative manifest SE, manifest cylinder, keratometry, or OZ diameter.


Assuntos
Hiperopia , Ceratomileuse Assistida por Excimer Laser In Situ , Humanos , Hiperopia/cirurgia , Midriáticos , Retratamento , Estudos Retrospectivos , Acuidade Visual
7.
J Refract Surg ; 33(11): 773-778, 2017 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-29117418

RESUMO

PURPOSE: This proof-of-concept study was designed to analyze the ability of in vivo biomechanical corneal analyses with the corneal visualization Scheimpflug technology (CorvisST; Oculus Optikgeräte, Wetzlar, Germany) to differentiate between normal eyes and eyes with manifest keratoconus after strictly eliminating the potential confounding factors intraocular pressure (IOP) and central corneal thickness (CCT). METHODS: In this retrospective, cross-sectional study, after pairwise matching for CCT and IOP, 29 normal eyes and 29 keratoconic eyes (one eye from each patient) were selected as study population. Older CorvisST parameters and the new Corvis Biomechanical Index (CBI), including several biomechanical and one tomographic parameter, as well as an adjusted CBI (aCBI) (including only biomechanical parameters), were compared regarding their discriminative ability between both groups. RESULTS: None of the CorvisST parameters of the former software version demonstrated statistically significant differences between normal and keratoconic eyes. On the other hand, the CBI and aCBI reached accuracies of 0.91 and 0.93, respectively, to discriminate between CCT- and IOP-matched normal and keratoconic eyes (CBI: [AUC/sensitivity/specificity]: 0.961/0.90/0.93; aCBI: [AUC/sensitivity/specificity]: 0.986/0.93/0.93). CONCLUSIONS: This study demonstrated that the concept of keratoconus screening with the CorvisST is effective in differentiating keratoconic from non-keratoconic eyes. The next steps will be testing the indices in subclinical keratoconus cases and hopefully combining biomechanical analyses with already established topography and tomography indices to further improve current keratoconus screening. [J Refract Surg. 2017;33(11):773-778.].


Assuntos
Córnea/fisiopatologia , Topografia da Córnea/métodos , Ceratocone/diagnóstico , Adulto , Córnea/diagnóstico por imagem , Estudos Transversais , Elasticidade , Feminino , Humanos , Ceratocone/fisiopatologia , Masculino , Pessoa de Meia-Idade , Curva ROC , Estudos Retrospectivos , Adulto Jovem
8.
Br J Ophthalmol ; 101(2): 97-102, 2017 02.
Artigo em Inglês | MEDLINE | ID: mdl-26892634

RESUMO

AIM: To explore the application of intraoperative wavefront aberrometry (IWA) for aphakia-based biometry using three existing formulae derived from autorefractive retinoscopy and introducing new improved formulae. METHODS: In 74 patients undergoing cataract surgery, three repeated measurements of aphakic spherical equivalent (SE) were taken. All measurements were objectively graded for their quality and evaluated with the 'limits of agreement' approach. ORs were calculated and analysis of variance was applied. The intraocular lens (IOL) power that would have given the target refraction was back-calculated from manifest refraction at 3 months postoperatively. Regression analysis was performed to generate two aphakic SE-based formulae for predicting this IOL. The accuracy of the formulae was determined by comparing them to conventional biometry and published aphakia formulae. RESULTS: In 32 eyes, three consecutive aphakic measurements were successful. Objective parameters of IWA map quality significantly impacted measurement variability (p<0.05). The limits of agreement of repeated aphakic SE readings were +0.66 dioptre (D) and -0.69 D. Intraoperative biometry by our formula resulted in 25% and 53% of all cases ±0.50D and ±1.00 D within SE target, respectively. A second formula that took axial length (AL) into account resulted in improved ratios of 41% and 70%, respectively. CONCLUSIONS: A reliable application of IWA to calculate IOL power during routine cataract surgery may not be feasible given the high rate of measurement failures and the large variations of the readings. To enable reliable IOL calculation from IWA, measurement precision must be improved and aphakic IOL formulae need to be fine-tuned.


Assuntos
Aberrometria/métodos , Afacia/fisiopatologia , Biometria/métodos , Lentes Intraoculares , Facoemulsificação , Refração Ocular/fisiologia , Adulto , Idoso , Feminino , Humanos , Período Intraoperatório , Implante de Lente Intraocular , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Análise de Regressão
9.
Int Ophthalmol ; 37(4): 957-964, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-27665612

RESUMO

PURPOSE: This study was initiated to introduce the term non-corneal ocular residual astigmatism (N-CORA) as a new parameter in astigmatic change analysis after implantation of two different types of non-toric, multifocal intraocular lenses (MIOL). METHODS: Seventy-two eyes from 72 consecutive patients after MIOL surgery were studied in terms of a retrospective, cross-sectional data analysis. Two types of spherical MIOL were used. Surgical technique in all patients was a 2.4-mm incision phacoemulsification, performed by one surgeon. To investigate the magnitude and axis of astigmatic changes, the true corneal astigmatism and Alpins vector method were applied. RESULTS: There were no statistically significant between-group differences related to the preoperative refraction or ocular residual astigmatism (ORA). After surgery, the mean refractive surgically induced astigmatism (RSIA) and the topographic SIA (TSIA) did not differ significantly between the lenses. The magnitude and orientation of ORA and N-CORA changed after surgery. CONCLUSIONS: There are no statistically significant differences in postoperative ORA in magnitude or axis when implanting different types of MIOL. The similarity of N-CORA between both MIOL types shows that both diffractive and refractive asymmetric MIOLs with plate haptics have the same pseudolentogenic astigmatic effect which could be presented in terms of the newly introduced parameter N-CORA.


Assuntos
Astigmatismo/cirurgia , Córnea/patologia , Lentes Intraoculares , Facoemulsificação/efeitos adversos , Segmento Posterior do Olho/cirurgia , Refração Ocular/fisiologia , Adulto , Idoso , Astigmatismo/diagnóstico , Astigmatismo/fisiopatologia , Córnea/cirurgia , Topografia da Córnea , Estudos Transversais , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias , Desenho de Prótese , Estudos Retrospectivos , Resultado do Tratamento
10.
Int Ophthalmol ; 37(4): 859-865, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-27624172

RESUMO

The purpose of this study was to analyze ocular residual astigmatism (ORA) before and after implantation of two different optical types of non-toric multifocal intraocular lenses (MIOL) in pre-cataract patients. This retrospective cohort study analyzed 72 eyes from 72 consecutive patients after MIOL surgery . To investigate magnitude and axis of astigmatic changes, the concepts of true corneal astigmatism and Alpins vector method were applied. There were no statistically significant between-group differences prior to surgery. The mean refractive surgically induced astigmatism (RSIA) (P = 0.063) and the topographic SIA (TSIA) (P = 0.828) did not differ significantly between the lenses, and the summated vector mean for ORA was reduced in terms of magnitude by approximately 0.30 Diopter. ORA in pseudophakic eyes mainly results from the posterior corneal surface and less from IOL tilting, postoperative posterior capsule shrinkage, or secondary cataract.


Assuntos
Câmara Anterior/cirurgia , Astigmatismo/diagnóstico , Catarata/complicações , Córnea/diagnóstico por imagem , Lentes Intraoculares , Pseudofacia/cirurgia , Refração Ocular/fisiologia , Adulto , Idoso , Astigmatismo/fisiopatologia , Topografia da Córnea , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Período Pós-Operatório , Desenho de Prótese , Estudos Retrospectivos , Fatores de Tempo , Acuidade Visual
11.
J Refract Surg ; 32(1): 34-9, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26812712

RESUMO

PURPOSE: To evaluate the effect of corneal cross-linking (CXL) in progressive keratoconus by applying in vivo static and dynamic Scheimpflug analyses. METHODS: In this longitudinal retrospective study, corneal topography and tomography (Pentacam HD) and dynamic Scheimpflug-based biomechanical analyses (CorvisST [CST]) of 24 eyes of 24 patients with progressive keratoconus before and 6 months after CXL were reviewed. New dynamic curve analyses, provided by Oculus Optikgeräte, were performed to analyze corneal dynamics throughout the entire response to the CST air puff impulse. RESULTS: Besides subtle changes of topography and tomography, only the CorvisST predefined parameters peak distance (-0.5 mm) and radius of the intended cornea (+0.5 mm; P < .05) demonstrated statistically significant differences 6 months after CXL. Using new dynamic curve analyses, additional distinct changes of the corneal biomechanical characteristics after CXL were noted. CONCLUSIONS: Published results of corneal biomechanical changes after CXL for progressive keratoconus based on single, predefined CST parameters are inconsistent. The new dynamic curve analyses demonstrate distinct changes of the biomechanical properties of the cornea and might therefore be the next step in understanding in vivo analyses of corneal biomechanics.


Assuntos
Córnea/fisiopatologia , Reagentes de Ligações Cruzadas , Elasticidade/fisiologia , Ceratocone/tratamento farmacológico , Fotoquimioterapia , Adolescente , Adulto , Fenômenos Biomecânicos , Colágeno/metabolismo , Substância Própria/metabolismo , Topografia da Córnea , Feminino , Humanos , Ceratocone/metabolismo , Ceratocone/fisiopatologia , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Fármacos Fotossensibilizantes/uso terapêutico , Refração Ocular/fisiologia , Estudos Retrospectivos , Riboflavina/uso terapêutico , Tomografia , Raios Ultravioleta , Acuidade Visual/fisiologia , Adulto Jovem
12.
J Cataract Refract Surg ; 41(6): 1160-7, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26189377

RESUMO

PURPOSE: To compare the effect of a rotating microkeratome (M2) and a linear microkeratome (SBK) on the change in the astigmatic component in eyes with preoperative plano refractive cylinder. SETTING: University Medical Centre Hamburg-Eppendorf, Hamburg, Germany. DESIGN: Retrospective case series. METHODS: An Allegretto excimer laser was used to perform laser ablation in myopic eyes of consecutive patients. The laser in situ keratomileusis (LASIK) procedure included mechanical flap preparation using a microkeratome, either a linear type with a single-use 90 µm head to create a nasal hinge or a rotating type with a single-use 90 µm head to create a superior hinge. The Alpins vector method was applied to describe the effects of LASIK on postoperative refractive cylinder. RESULTS: The study evaluated 1045 eyes of 852 patients. Although the mean overall efficacy and safety indices indicate the procedure was highly precise, safe, and efficient, there were statistically significant differences in surgically induced astigmatism (SIA) between the microkeratomes (P = .002). The postoperative refractive cylinder (ie, SIA) was 0.75 diopter (D) or more in 116 eyes (11.1%), 44 (12.8%) of 344 linear cases and 72 (10.3%) of 701 rotating cases. Independent of the type of microkeratome used, the SIA was slightly higher in eyes treated first; the mean magnitude of the induced astigmatism was 0.35 D. CONCLUSIONS: In approximately 10% of eyes with preoperative plano refractive myopia, the astigmatic component tended to be overcorrected. Nevertheless, independent of the type of microkeratome, the maximum mean magnitude of refractive cylinder documented was 0.35 D. FINANCIAL DISCLOSURE: No author has a financial or proprietary interest in any material or method mentioned.


Assuntos
Astigmatismo/fisiopatologia , Substância Própria/cirurgia , Ceratomileuse Assistida por Excimer Laser In Situ/métodos , Lasers de Excimer/uso terapêutico , Miopia/cirurgia , Retalhos Cirúrgicos , Adulto , Substância Própria/patologia , Topografia da Córnea , Feminino , Humanos , Ceratomileuse Assistida por Excimer Laser In Situ/instrumentação , Masculino , Pessoa de Meia-Idade , Miopia/fisiopatologia , Refração Ocular/fisiologia , Estudos Retrospectivos , Acuidade Visual/fisiologia , Adulto Jovem
13.
PLoS One ; 10(3): e0120944, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25781907

RESUMO

The impact of using a Femtosecond laser on final functional results of penetrating keratoplasty is low. The corneal incisions presented here result from laser ablations with ultrafast desorption by impulsive vibrational excitation (DIVE). The results of the current study are based on the first proof-of-principle experiments using a mobile, newly introduced picosecond infrared laser system, and indicate that wavelengths in the mid-infrared range centered at 3 µm are efficient for obtaining applanation-free deep cuts on porcine corneas.


Assuntos
Córnea/cirurgia , Ceratoplastia Penetrante , Terapia a Laser , Animais , Ceratoplastia Penetrante/instrumentação , Ceratoplastia Penetrante/métodos , Terapia a Laser/instrumentação , Terapia a Laser/métodos , Suínos
14.
Graefes Arch Clin Exp Ophthalmol ; 253(7): 1097-104, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25655649

RESUMO

PURPOSE: This study was initiated to investigate whether the presence of macular oedema influenced intraocular lens (IOL) power calculation in eyes with epiretinal membrane. METHODS: The files of patients undergoing combined phacoemulsification were retrospectively reviewed. Two groups were defined according to presence of macular oedema. The main outcome measure was the IOL power prediction error (PE). Secondary outcome measures were the correlation between preoperative macular thickness, absolute change of macular thickness and dioptric shift. The mean postoperative PE achieved with the Haigis formula was compared with the PE that would have been obtained had the SRKII and HofferQ formulas been used. RESULTS: We investigated 47 eyes of 47 consecutive patients. Regardless of the IOL formula used, the PE was on average higher in eyes without macula oedema (group 1). The myopic dioptric shift was dependent on preoperative macular thickness and absolute change of macular thickness. This association was more markedly pronounced in group 1. CONCLUSIONS: Increased retinal thickness is the main cause for underestimation of the cornea-photoreceptor layer distance, and therefore could contribute to inaccuracy in IOL power calculations. The current results show that a myopic shift tends to be less pronounced in cases where a macula oedema is present. Eyes with pure traction have less predictable refractive results in terms of higher PE and dioptric shift.


Assuntos
Membrana Epirretiniana/cirurgia , Edema Macular/complicações , Facoemulsificação , Complicações Pós-Operatórias , Erros de Refração/etiologia , Vitrectomia , Idoso , Idoso de 80 Anos ou mais , Membrana Epirretiniana/fisiopatologia , Feminino , Humanos , Implante de Lente Intraocular , Lentes Intraoculares , Edema Macular/fisiopatologia , Masculino , Pessoa de Meia-Idade , Óptica e Fotônica , Erros de Refração/fisiopatologia , Retina/patologia , Estudos Retrospectivos
15.
Clin Ophthalmol ; 9: 305-11, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25709393

RESUMO

PURPOSE: This study was initiated to evaluate biomechanical changes using the Corvis ST tonometer (CST) on the cornea after laser in situ keratomileusis (LASIK). SETTING: University Medical Center Hamburg-Eppendorf, Germany, and Care Vision Refractive Centers, Germany. DESIGN: Retrospective cohort study. METHODS: This retrospective study included 37 eyes of 37 refractive patients. All CST measurements were performed 1 day before surgery and at the 1-month follow-up examination. The LASIK procedure included mechanical flap preparation using a Moria SBK microkeratome and an Allegretto excimer laser platform. RESULTS: Statistically significant differences were observed for mean first applanation length, mean first and second deflection lengths, mean first and second deflection amplitudes, radius of curvature, and peak distance. Significant positive correlations were found between the change (Δ) of radius of curvature and manifest refraction spherical equivalent (MRSE), ablation depth, and Δintraocular pressure as well as between AD and ΔHC-time. Each diopter of myopic correction in MRSE resulted in an increase in Δradius of curvature of 0.2 mm. CONCLUSION: Several CST parameters were statistically significantly altered by LASIK, thereby indicating that flap creation, ablation, or both, significantly change the ability of the cornea to absorb or dissipate energy.

16.
Br J Ophthalmol ; 98(11): 1484-91, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-24879809

RESUMO

OBJECTIVE: To provide the first clinical data in determining the feasibility, quality and precision of intraoperative wavefront aberrometry (IWA)-based refraction in patients with cataract. DESIGN: IWA refraction was recorded at 7 defined measurement points during standardised cataract surgery in 74 eyes of 74 consecutive patients (mean age 69±11.3 years). Precision and measurement quality was evaluated by the 'limits of agreement' approach, regression analysis, correlation analysis, Analysis of variance (ANOVA) and ORs for predicting measurement failure. Wavefront map (WFM) quality was objectivised and compared with the Pentacam Nuclear Staging analysis. RESULTS: Out of 814 IWA measurement attempts, 462 WFMs could be obtained. The most successful readings (n=63) were achieved in aphakia with viscoelastic. The highest (50.63%, SD 20.23) and lowest (29.19%, SD 13.94) quality of WFMs across all measurement points were found after clear corneal incision and in pseudophakia with viscoelastic, respectively. High consistency across repeated measures were found for mean spherical equivalent (SE) differences in aphakia with -0.01D and pseudophakia with -0.01D, but ranges were high (limits of agreement +0.69 D and -0.72 D; +1.53 D and -1.54 D, respectively). With increasing WFM quality, higher precision in measurements was observed. CONCLUSIONS: This is the first report addressing quality and reproducibility of WA in a large sample. IWA refraction in aphakia, for instance, appears to be reliable once stable and pressurised anterior chamber conditions are achieved. More efforts are required to improve the precision and quality of measurements before IWA can be used to guide the surgical refractive plan in cataract surgery.


Assuntos
Aberrometria/métodos , Extração de Catarata , Refração Ocular/fisiologia , Acuidade Visual/fisiologia , Idoso , Afacia/fisiopatologia , Estudos de Viabilidade , Feminino , Humanos , Período Intraoperatório , Masculino , Estudos Prospectivos , Pseudofacia/fisiopatologia , Reprodutibilidade dos Testes
17.
BMC Ophthalmol ; 14: 1, 2014 Jan 06.
Artigo em Inglês | MEDLINE | ID: mdl-24393469

RESUMO

BACKGROUND: This study examined the refractive and visual outcome of wavefront-optimized laser in situ keratomileusis (LASIK) in eyes with low myopia and compound myopic astigmatism ≤ 0.75 diopter (D). METHODS: 153 eyes from 153 consecutive myopic patients (74 male, 79 female; mean age at surgery 40.4 ± 10.4 years) who had a preoperative refractive cylinder ≤ 0.75 D and a manifest sphere between -0.25 D and -2.75 D, and who had completed 4-month follow-up. Three subgroups defined by the magnitude of preoperative manifest refractive cylinder (0.25, 0.50, and 0.75 D) were formed. Manifest refraction, uncorrected and corrected visual acuity were assessed pre- and postoperatively. The astigmatic changes achieved were determined using the Alpins vector analysis. RESULTS: After 4 months (120.0 ± 27.6 days) of follow-up, a mean uncorrected distant visual acuity of 0.07 ± 0.11 logMAR and a mean manifest refraction spherical equivalent of -0.06 ± 0.56 D were found. There was no statistically significant difference in efficacy and safety between the preoperative cylinder groups. Astigmatic overcorrection for preoperative cylinder of ≤ 0.50 D was suggested by the correction index, the magnitude of error, the index of success, and the flattening index. CONCLUSIONS: Low myopic eyes with a preoperative cylinder of ≤ 0.50 D were significantly overcorrected with regard to cylinder correction when combined with low myopic LASIK. Accordingly, we are cautious in recommending full astigmatic correction for eyes with low myopia and manifest cylinder of ≤ 0.50 D.


Assuntos
Astigmatismo/cirurgia , Ceratomileuse Assistida por Excimer Laser In Situ , Miopia/cirurgia , Adulto , Astigmatismo/fisiopatologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Miopia/fisiopatologia , Refração Ocular/fisiologia , Estudos Retrospectivos , Acuidade Visual/fisiologia
18.
Optom Vis Sci ; 91(2): 178-86, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24445720

RESUMO

PURPOSE: To evaluate anterior and posterior changes in corneal topography and tomography after corneal crosslinking (CXL) in eyes with progressive keratoconus. METHODS: Scheimpflug analyses (Pentacam, Oculus) of 20 eyes with keratoconus performed before and after corneal CXL were included into retrospective analysis. Mean follow-up was 2 years. Changes in topographic, tomographic, and pachymetric values were statistically analyzed applying analysis of variance. Further, the distance and direction between the anterior maximum keratometry (K(max)) and the apex as well as the distance and direction between the thinnest point in corneal thickness (TPCT) and the corneal apex before and after CXL were studied. RESULTS: Two years after CXL, a statistically significant reduction of the keratometry at the flat meridian (-0.8 D, p < 0.05), the steep meridian (-0.5 D, p < 0.05), the "index of surface variance" (-5.3, p < 0.05), and the "index of highest decentration" (-0.05, p < 0.05) could be demonstrated. While the elevation of the front surface at the apex decreased (-1.5 µm, p < 0.05), the back elevation at the apex (+2 µm, p < 0.05) increased. Although not reaching statistical significance, the maximum front and back elevation demonstrated the same trend; while maximum front elevation data remained stable (-0.3 µm, p = 0.961), maximum back elevation data increased (+6.7 µm, p = 0.122). The corneal thickness at the apex (-22.0 µm, p < 0.001) and the TPCT (-20.0 µm, p < 0.001) decreased, leading to an increase of the corneal thickness progression from the corneal apex to the periphery. The position of K(max) and TPCT remained stable. CONCLUSIONS: Corneal topography proved to be useful in the follow-up for CXL because of significant changes in the keratometry. Increasing posterior elevation values, despite a stabilized anterior corneal surface, might be a sign of ongoing ectatic changes in the posterior corneal surface.


Assuntos
Córnea/patologia , Reagentes de Ligações Cruzadas/uso terapêutico , Ceratocone/tratamento farmacológico , Ceratocone/patologia , Fotoquimioterapia , Adolescente , Adulto , Colágeno/metabolismo , Paquimetria Corneana , Substância Própria/metabolismo , Topografia da Córnea , Feminino , Humanos , Ceratocone/metabolismo , Masculino , Pessoa de Meia-Idade , Fármacos Fotossensibilizantes/uso terapêutico , Estudos Retrospectivos , Riboflavina/uso terapêutico , Tomografia de Coerência Óptica , Raios Ultravioleta , Adulto Jovem
19.
J Cataract Refract Surg ; 40(2): 232-8, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24333012

RESUMO

PURPOSE: To analyze the influence of demographic and ocular factors on ocular residual astigmatism (ORA) in myopic laser in situ keratomileusis (LASIK). SETTING: University Medical Center Hamburg-Eppendorf, Hamburg, Germany. DESIGN: Retrospective cross-sectional data analysis. METHODS: Eyes of consecutive myopic patients scheduled for LASIK were studied to evaluate the influence on preexisting ORA of age, sex, ocular dominance, subjective cylinder and topographic astigmatism, subjective sphere, and mesopic pupil size. The ORA was determined using Alpins vector analysis. Two subgroups, defined by the ratio of ORA to preoperative refractive cylinder (R), were formed: ORA:R ≥ 1.0 and ORA:R <1.0). RESULTS: The study comprised 2991 eyes (2991 patients). The mean ORA was 0.75 diopter (D) ± 0.39 (SD) (range 0.00 to 2.00 D); 1372 (46%) eyes had ORA of 1.00 D or more. Ordinary least square estimations and odds ratios showed that subjective sphere, male sex, and dominant eye were negative predictors of the degree of preoperative ORA, while increasing age and larger mesopic pupils did not indicate ORA orientation. With-the-rule astigmatism meridian was more likely in eyes with low ORA, while oblique and against-the-rule meridians were related to high ORA. CONCLUSIONS: The preoperative assessment of refractive surgery candidates should consider the interaction between topographic, refractive, and ORA because corneal refractive surgery is more successful in eyes in which the cylinder mainly originates from the anterior cornea. The current data can help identify patients at high risk for having a significant difference between subjective cylinder and topographic astigmatism. FINANCIAL DISCLOSURE: No author has a financial or proprietary interest in any material or method mentioned.


Assuntos
Astigmatismo/fisiopatologia , Córnea/fisiopatologia , Demografia , Ceratomileuse Assistida por Excimer Laser In Situ , Lasers de Excimer/uso terapêutico , Miopia/cirurgia , Adolescente , Adulto , Idoso , Astigmatismo/diagnóstico , Topografia da Córnea , Estudos Transversais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Miopia/fisiopatologia , Razão de Chances , Período Pré-Operatório , Estudos Retrospectivos , Fatores de Risco , Adulto Jovem
20.
Invest Ophthalmol Vis Sci ; 54(13): 7819-27, 2013 Dec 02.
Artigo em Inglês | MEDLINE | ID: mdl-24222305

RESUMO

PURPOSE: In most mammalian species, retinal ganglion cell (RGC) axons are myelinated in the optic nerve, but remain nonmyelinated in the retinal nerve fiber layer and the most proximal (i.e., retina-near) region of the nerve. Here we analyzed whether RGCs are involved in the control of this characteristic distribution of oligodendrocytes and myelin in the primary visual pathway of mice. METHODS: Neurospheres were enriched in oligodendrocyte progenitor cells (OPCs) by a short-term exposure to platelet-derived growth factor (PDGF) and grafted into the retina of young postnatal mice close to the optic disc. Immunohistochemistry was performed to study the integration and differentiation of the grafted cells, and the formation of donor-derived myelin in the normally nonmyelinated retinal nerve fiber layer and intrabulbar and most proximal retrobulbar region of the optic nerve. RESULTS: Intraretinal transplantations of small-sized PDGF-treated neurospheres into young postnatal mice resulted in extensive integration of the grafted cells into host retinas. A significant fraction of the donor cells differentiated into oligodendrocytes that myelinated the nerve fiber layer. Importantly, RGC axon segments within the normally nonmyelinated intrabulbar and most proximal retrobulbar region of the nerve also became myelinated in a fraction of animals. CONCLUSIONS: This is the first report demonstrating that the normally nonmyelinated intrabulbar and retrobulbar segments of RGC axons are competent to become myelinated. Results support the view that the differential distribution of myelin and oligodendrocytes in the primary visual pathway is controlled by nonneuronal factors rather than by the RGCs themselves.


Assuntos
Animais Recém-Nascidos , Axônios/metabolismo , Bainha de Mielina/metabolismo , Células Ganglionares da Retina/metabolismo , Animais , Diferenciação Celular , Células Cultivadas , Imuno-Histoquímica , Hibridização In Situ , Camundongos , Camundongos Endogâmicos C57BL , Microscopia Eletrônica , Células Ganglionares da Retina/citologia , Transplante de Células-Tronco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA