Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
JACC Cardiovasc Interv ; 15(16): 1639-1648, 2022 08 22.
Artigo em Inglês | MEDLINE | ID: mdl-35981838

RESUMO

BACKGROUND: Contrast-induced nephropathy (CIN) can occur after cardiovascular procedures using contrast media, which is associated with increased morbidity and mortality. RenalGuard is a closed-loop system designed to match intravenous hydration with diuretic-induced diuresis that has shown mixed results in the prevention of CIN in previous randomized controlled trials. OBJECTIVES: The STRENGTH (Study Evaluating the Use of RenalGuard to Protect Patients at High Risk of AKI) study assessed whether RenalGuard (PLC Medical Systems) is superior to standard intravenous hydration for CIN prevention in patients with chronic kidney disease undergoing complex cardiovascular procedures. METHODS: STRENGTH is a multicenter, international, open-label, postmarket, prospective, randomized (1:1) study monitored by the Cardiovascular European Research Center (Massy, France) that included a total of 259 patients with moderate to severe chronic kidney disease (estimated glomerular filtration 15-40 mL/min/m2) requiring a complex coronary, structural, or peripheral procedure with an expected contrast injection of at least 3 times the estimated glomerular filtration rate. Patients were randomized to either RenalGuard or intravenous saline hydration according to current guidelines. RESULTS: The primary endpoint, the incidence of CIN at day 3 after the procedure, was similar between the 2 groups (17/107 [15.9%] in the RG group vs 15/110 [13.9%] in the control group; P = 0.62). In addition, none of the secondary endpoints differed between the 2 groups. CONCLUSIONS: In high-risk patients undergoing complex cardiovascular interventions in experienced centers, furosemide-induced high urine output with matched hydration using the RenalGuard system did not reduce the risk of CIN and adverse outcomes at 12 months compared with conventional intravenous hydration.


Assuntos
Injúria Renal Aguda , Insuficiência Renal Crônica , Injúria Renal Aguda/induzido quimicamente , Injúria Renal Aguda/diagnóstico , Injúria Renal Aguda/prevenção & controle , Meios de Contraste/efeitos adversos , Angiografia Coronária , Hidratação/efeitos adversos , Humanos , Estudos Prospectivos , Ensaios Clínicos Controlados Aleatórios como Assunto , Insuficiência Renal Crônica/complicações , Insuficiência Renal Crônica/diagnóstico , Fatores de Risco , Resultado do Tratamento
2.
Eur J Heart Fail ; 23(11): 1971-1978, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34288287

RESUMO

AIMS: To determine the effects of percutaneous mitral annuloplasty on symptoms, walk distance and left ventricular (LV) structure and function in patients with mild or moderate secondary mitral regurgitation (SMR). METHODS AND RESULTS: This was a pooled analysis of patients (n = 68) who, despite guideline-directed medical therapy had symptomatic heart failure (HF) with mild (n = 25) or moderate (n = 43) SMR treated with percutaneous mitral annuloplasty as part of the TITAN, TITAN II, or REDUCE-FMR trials. Primary outcomes were changes in symptoms, 6-min walk distance, and quality of life assessed by the Kansas City Cardiomyopathy Questionnaire (KCCQ) after 1 year. Secondary analyses included changes in LV structure and function. At 1 year, New York Heart Association class status was maintained (48%) or improved (46%) in most patients, mean KCCQ scores increased from baseline by 10 units [95% confidence interval (CI) 3 to17; P < 0.01] and mean 6-min walk test distance increased by 34 m (95% CI 12 to 57; P < 0.01). SMR grade improved in 25% of patients and was maintained in 58% of patients with changes in mean regurgitant volume of -7 mL (95% CI -11 to -3; P < 0.001), vena contracta -0.11 cm (95% CI -0.20 to -0.02; P < 0.05), and effective regurgitant orifice area -0.03 cm2 (95% CI -0.06 to -0.01; P < 0.05). There were non-significant improvements in LV ejection fraction and volumes. Survival over 1 year was 89% with no difference between mild (96%) and moderate (86%) SMR (log-rank P = 0.22). Progression-free survival was 70% (82% in mild vs. 63% in moderate SMR; P = 0.16). Freedom from HF hospitalization was 73% (87% in mild SMR vs. 66% in moderate SMR; P = 0.07). CONCLUSION: Among patients with symptomatic HF and mild or moderate SMR on guideline-directed medical therapy, percutaneous mitral annuloplasty was associated with improvements in symptoms, SMR, a stabilization of LV structure and function, and high survival rates.


Assuntos
Insuficiência Cardíaca , Anuloplastia da Valva Mitral , Insuficiência da Valva Mitral , Ecocardiografia , Insuficiência Cardíaca/cirurgia , Humanos , Insuficiência da Valva Mitral/diagnóstico , Insuficiência da Valva Mitral/cirurgia , Qualidade de Vida , Resultado do Tratamento
3.
JACC Heart Fail ; 7(11): 945-955, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-31521683

RESUMO

OBJECTIVES: This study sought to evaluate the effects of the Carillon device on mitral regurgitation severity and left ventricular remodeling. BACKGROUND: Functional mitral regurgitation (FMR) complicates heart failure with reduced ejection fraction and is associated with a poor prognosis. METHODS: In this blinded, randomized, proof-of-concept, sham-controlled trial, 120 patients receiving optimal heart failure medical therapy were assigned to a coronary sinus-based mitral annular reduction approach for FMR or sham. The pre-specified primary endpoint was change in mitral regurgitant volume at 12 months, measured by quantitative echocardiography according to an intention-to-treat analysis. RESULTS: Patients (69.8 ± 9.5 years of age) were randomized to either the treatment (n = 87) or the sham-controlled (n = 33) arm. There were no significant differences in baseline characteristics between the groups. In the treatment group, 73 of 87 (84%) had the device implanted. The primary endpoint was met, with a statistically significant reduction in mitral regurgitant volume in the treatment group compared to the control group (decrease of 7.1 ml/beat [95% confidence interval [CI]: -11.7 to -2.5] vs. an increase of 3.3 ml/beat [95% CI: -6.0 to 12.6], respectively; p = 0.049). Additionally, there was a significant reduction in left ventricular volumes in patients receiving the device versus those in the control group (left ventricular end-diastolic volume decrease of 10.4 ml [95% CI: -18.5 to -2.4] vs. an increase of 6.5 ml [95% CI: -5.1 to 18.2]; p = 0.03 and left ventricular end-systolic volume decrease of 6.2 ml [95% CI: -12.8 to 0.4] vs. an increase of 6.1 ml [95% CI: -1.42 to 13.6]; p = 0.04). CONCLUSIONS: The Carillon device significantly reduced mitral regurgitant volume and left ventricular volumes in symptomatic patients with functional mitral regurgitation receiving optimal medical therapy. (Carillon Mitral Contour System for Reducing Functional Mitral Regurgitation [REDUCE FMR]; NCT02325830).


Assuntos
Anuloplastia da Valva Mitral/instrumentação , Insuficiência da Valva Mitral/cirurgia , Idoso , Método Duplo-Cego , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Anuloplastia da Valva Mitral/métodos , Estudo de Prova de Conceito , Índice de Gravidade de Doença , Remodelação Ventricular
4.
Nephrol Ther ; 5(7): 648-51, 2009 Dec.
Artigo em Francês | MEDLINE | ID: mdl-19617020

RESUMO

The dramatic occurrence, during haemodialysis sessions, of hemodynamic and cerebral symptoms in a 53-year-old haemodialysed woman with a history of aortocoronary bypass leads to discovery and treatment by percutaneous angioplasty and stenting of a significant stenosis of proximal subclavian artery, ipsilateral to the arteriovenous fistula, with retrograde flow in internal mammary artery graft and vertebral artery. All symptoms resume after interventional radiology. Analysis of literature confirms possibility of coronary artery steal induced by use of the arteriovenous fistula in haemodialysed patients with ipsilateral internal mammary bypass, especially if there is concomitant subclavian artery stenosis, and leading us to discuss the diagnostic and therapeutic implications.


Assuntos
Ponte de Artéria Coronária/efeitos adversos , Artéria Torácica Interna , Diálise Renal , Doenças Vasculares/etiologia , Feminino , Humanos , Pessoa de Meia-Idade
5.
Circ Cardiovasc Interv ; 1(2): 134-42, 2008 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-20031668

RESUMO

The coronary venous system is routinely targeted during electrophysiological measurements or cardiac resynchronization therapy. However, several novel interventional techniques require coronary venous catheterization and visualization as well as transvenous delivery of devices and/or therapeutic agents. Recent reports suggest the possibility of a transvenous approach for the interventional treatment of refractory angina and mitral valve regurgitation. In addition, the coronary venous system has been used as a route for the delivery of stem cells in patients with left ventricular dysfunction due to ischemic heart disease. We review the potential value of using a coronary venous approach in association with recent therapeutic developments in the interventional treatment of structural and ischemic heart disease. We will also discuss techniques related to coronary venous catheterization.


Assuntos
Cateterismo Venoso Central/métodos , Insuficiência da Valva Mitral/terapia , Isquemia Miocárdica/terapia , Disfunção Ventricular Esquerda/terapia , Vasos Coronários/patologia , Sistemas de Liberação de Medicamentos , Eletrodiagnóstico , Humanos , Insuficiência da Valva Mitral/diagnóstico , Isquemia Miocárdica/fisiopatologia , Próteses e Implantes , Transplante de Células-Tronco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA