1.
Circ Cardiovasc Interv ; 10(8)2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28801540

RESUMO

BACKGROUND: The frequency of complex percutaneous coronary interventions (PCIs) has increased in the last few years, with a growing concern on the radiation dose received by the patients. Multicenter data from large unselected populations on patients' radiation doses during coronary angiography (CA) and PCI and temporal trends are lacking. This study sought to evaluate the temporal trends in patients' exposure to radiation from CA and PCI. METHODS AND RESULTS: Data were taken from the CARDIO-ARSIF registry that prospectively collects data on all CAs and PCIs performed in the 36 catheterization laboratories in the Greater Paris Area, the most populated regions in France with about 12 million inhabitants. Kerma area product and Fluoroscopy time from 152 684 consecutive CAs and 103 177 PCIs performed between 2009 and 2013 were analyzed. A continuous trend for a decrease in median [interquartile range] Kerma area product was observed, from 33 [19-55] Gy cm2 in 2009 to 27 [16-44] Gy cm2 in 2013 for CA (P<0.0001), and from 73 [41-125] to 55 [31-91] Gy cm2 for PCI (P<0.0001). Time-course differences in Kerma area product remained highly significant after adjustment on Fluoroscopy time, PCI procedure complexity, change of x-ray equipment, and other patient- and procedure-related covariates. CONCLUSIONS: In a large patient population, a steady temporal decrease in patient radiation exposure during CA and PCI was noted between 2009 and 2013. Kerma area product reduction was consistent in all types of procedure and was independent of patient-related factors and PCI procedure complexity.


Assuntos
Angiografia Coronária/tendências , Intervenção Coronária Percutânea/tendências , Doses de Radiação , Sistema de Registros , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Análise Multivariada
2.
Eur Heart J Cardiovasc Imaging ; 18(4): 392-401, 2017 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-28064155

RESUMO

AIMS: We sought to assess whether global longitudinal strain (GLS) measured early during treatment with anthracyclines (at a cumulative dose of 150 mg/m2) can predict subsequent alterations in left ventricular ejection fraction. METHODS AND RESULTS: Eighty-six patients with Hodgkin's disease, non-Hodgkin's lymphoma, or acute leukaemia and receiving anthracyclines were prospectively included. Patients underwent complete echocardiography on four occasions: baseline (V1); after reaching a cumulative dose of 150 mg/m2 (V2); end of treatment (V3); and 1 year follow-up (V4). Six patients developed cardiotoxicity, defined as a decrease in left ventricular ejection fraction of >10 percentage points, to a value <53%, at V4. GLS measured at V1 and V2 was significantly lower in the cardiotoxicity group vs. the controls (P = 0.042 and P = 0.01, respectively). Compared with GLS at V1, GLS obtained at V2 provided incremental predictive information and appeared to be the strongest predictor of cardiotoxicity (area under the receiver-operating-characteristic curve, 0.82). At a threshold of -17.45% for GLS measured at V2, the sensitivity and specificity of detecting cardiotoxicity were 67% (95% confidence interval 33-100) and 97% (95% confidence interval 94-100), respectively. CONCLUSION: GLS greater than -17.45%, obtained after 150 mg/m2 of anthracycline therapy, is an independent predictor of future anthracycline-induced cardiotoxicity. These findings should encourage physicians to perform echocardiography earlier during treatment with anthracyclines.


Assuntos
Antraciclinas/efeitos adversos , Cardiotoxicidade/diagnóstico por imagem , Neoplasias Hematológicas/tratamento farmacológico , Disfunção Ventricular Esquerda/induzido quimicamente , Disfunção Ventricular Esquerda/diagnóstico por imagem , Adulto , Idoso , Antraciclinas/uso terapêutico , Cardiotoxicidade/etiologia , Cardiotoxicidade/fisiopatologia , Estudos de Coortes , Relação Dose-Resposta a Droga , Esquema de Medicação , Ecocardiografia , Feminino , Neoplasias Hematológicas/patologia , Humanos , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Variações Dependentes do Observador , Seleção de Pacientes , Valor Preditivo dos Testes , Prognóstico , Estudos Prospectivos , Índice de Gravidade de Doença , Volume Sistólico/efeitos dos fármacos
3.
Radiat Prot Dosimetry ; 175(1): 17-25, 2017 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-27624893

RESUMO

The objective of this study was to estimate the French national updated reference levels (RLs) for coronary angiography (CA) and percutaneous coronary intervention (PCI) by a dose audit from a large data set of unselected procedures and in standard-sized patients. Kerma-area product (PKA), air kerma at interventional point (Ka,r), fluoroscopy time (FT), and the number of registered frames (NFs) and runs (NRs) were collected from 51 229 CAs and 42 222 PCIs performed over a 12-month period at 61 French hospitals. RLs estimated by the 75th percentile in CAs and PCIs performed in unselected patients were 36 and 78 Gy.cm² for PKA, 498 and 1285 mGy for Ka,r, 6 and 15 min for FT, and 566 and 960 for NF, respectively. These values were consistent with the RLs calculated in standard-sized patients. The large difference in dose between sexes leads us to propose specific RLs in males and females. The results suggest a trend for a time-course reduction in RLs for interventional coronary procedures.


Assuntos
Angiografia Coronária , Fluoroscopia , Doses de Radiação , Feminino , Humanos , Masculino , Intervenção Coronária Percutânea , Radiografia Intervencionista
4.
Catheter Cardiovasc Interv ; 83(5): 729-38, 2014 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-24323486

RESUMO

OBJECTIVES: To evaluate practices for the protection from radiation of patients during coronary angiography (CA) and percutaneous coronary intervention (PCI), and to update reference values for the main radiation dose parameters. BACKGROUND: Few multicenter data from large populations exist on radiation doses to patients during CA and PCI. METHODS: RAY'ACT is a multicenter, nationwide French survey, with retrospective analysis of radiation parameters routinely registered in professional software from 33,937 CAs and 27,826 PCIs performed at 44 centers from January 1, through December 31, 2010. RESULTS: Kerma-area product (KAP) was registered in 91.7% (44/48) of centers and in 91.5% of procedures for CA (median, 27.2 Gy·cm(2) , interquartile range [IQR], 15.5-45.2) and 91.1% for PCI (median, 56.8 Gy·cm(2) , IQR, 32.8-94.6). Fluoroscopy time was registered in 87.5% (42/48) of centers and in 83.1% of procedures (median, 3.7 min, IQR, 2.3-6.3 for CA; 10.3 min, 6.7-16.2 for PCI). Variability across centers was high. Old equipment and routine left ventriculography were more common and number of registered frames and frame rate were higher in centers delivering high doses. The radial route was associated with lower doses than the femoral route (median KAP 26.8 Gy·cm(2) [15.1-44.25] vs. 28.1 [16.4-46.9] for CA, respectively; and 55.6 Gy·cm(2) [32.2-92.1] vs. 59.4 [24.6-99.9] for PCI, respectively; P < 0.01). CONCLUSIONS: This survey showed a very high rate of compliance with dose registration during CA and PCI in French nonacademic hospitals. Updated diagnostic reference values are established for the main dose parameters (KAP, 45 Gy·cm(2) for CA, 95 Gy·cm(2) for PCI).


Assuntos
Angiografia Coronária , Intervenção Coronária Percutânea , Doses de Radiação , Lesões por Radiação/prevenção & controle , Radiografia Intervencionista , Idoso , Angiografia Coronária/efeitos adversos , Angiografia Coronária/normas , Feminino , Artéria Femoral/diagnóstico por imagem , Fluoroscopia , França , Fidelidade a Diretrizes , Pesquisas sobre Atenção à Saúde , Humanos , Masculino , Pessoa de Meia-Idade , Segurança do Paciente , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/normas , Guias de Prática Clínica como Assunto , Padrões de Prática Médica , Valor Preditivo dos Testes , Artéria Radial/diagnóstico por imagem , Lesões por Radiação/etiologia , Radiografia Intervencionista/efeitos adversos , Radiografia Intervencionista/normas , Valores de Referência , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo
7.
Arch Cardiovasc Dis ; 102(12): 821-7, 2009 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-19963193

RESUMO

BACKGROUND: Exposure of patients to radiation from invasive cardiac procedures is high and may be deleterious. AIMS: To assess the effectiveness of a dose-reduction programme based on radiation-protection training, according to the recommendations of the Euratom Council, the International Commission on Radiological Protection and the French Society of Cardiology. METHODS: In this single-centre survey, dose-area product (DAP, Gy.cm(2)), fluoroscopy time (minutes) and number of runs were evaluated in 3285 consecutive procedures (2077 coronary angiographies [CAs], 1208 percutaneous coronary interventions [PCIs]), performed one year before (2005) and two years after (2006 to 2007) implementation of a programme for radiation dose-reduction. The programme included a 2-day training course in radiological protection for all medical and paramedical staff and recommendations for routine use of low fluoroscopic and acquisition pulse rates (6.25 and 12.5 i/s, respectively), large field size (23cm), maximal collimation and optimal X-ray tube/patient/detector distances. Routine left ventriculography was discouraged. The radial approach was used in>80% of the procedures. RESULTS: Compared with 2005, a significant 50% reduction in DAP was observed in 2006 and 2007 during CA (median [interquartile range] 53 Gy.cm(2) [33-84] vs 26 [16-43] and 21 [14-32], respectively; p<0.0001) and PCI (125 Gy.cm(2) [78-184] vs 49 [31-79] and 44 [27-66], respectively; p<0.0001). Fluoroscopy time and number of runs did not vary significantly in 2006, and decreased slightly in 2007, likely due to an important reduction in rate of left ventriculographies (from 32 to 4%). Inter-operator variability in DAP was reduced. CONCLUSION: Training in radiation protection for interventional cardiologists and use of simple and cost-free dose-reduction techniques were associated with a 50% reduction in radiation exposure to patients undergoing invasive cardiac procedures, without any loss of diagnostic information.


Assuntos
Angioplastia Coronária com Balão/efeitos adversos , Cardiologia/educação , Angiografia Coronária/efeitos adversos , Doses de Radiação , Lesões por Radiação/prevenção & controle , Proteção Radiológica , Radiografia Intervencionista/efeitos adversos , Radiologia Intervencionista/educação , Idoso , Currículo , Relação Dose-Resposta à Radiação , Feminino , Fluoroscopia/efeitos adversos , Fidelidade a Diretrizes , Pesquisas sobre Atenção à Saúde , Humanos , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Guias de Prática Clínica como Assunto , Avaliação de Programas e Projetos de Saúde , Lesões por Radiação/etiologia , Sistema de Registros , Medição de Risco , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA