Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Retina ; 43(3): 529-530, 2023 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-32516226

RESUMO

PURPOSE: To introduce a new surgical technique that can keep constant intraocular pressure of the eyeball during peeling epiretinal membrane under silicone oil status. METHODS: A viscoelastic agent was injected into the air pump of the constellation system via the metal tip. This procedure offers a buffer zone to keep constant pressure within the eyeball without disturbing the surgical field by an air bubble. RESULTS: Three cases were performed efficiently (15 ± 5 minutes) under this technique with improvement in anatomical feature and visual function after the surgery. CONCLUSION: Using this simple yet important technique can provide us the constant intraocular pressure without hypotony and avoid the traditional complicated procedures.


Assuntos
Membrana Epirretiniana , Descolamento Retiniano , Humanos , Membrana Epirretiniana/etiologia , Vitrectomia/métodos , Óleos de Silicone , Pressão Intraocular
2.
J Chin Med Assoc ; 85(7): 793-798, 2022 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-35648158

RESUMO

BACKGROUND: Although teleophthalmology has gained traction in recent years, it is at the center of the coronavirus disease pandemic. However, most hospitals are not ready owing to a severe lack of real-world experience. Furthermore, a limited number of studies have evaluated telemedicine applications on remote islands. This study aimed to evaluate real-world clinical and referral accuracy, image quality, physician-perceived diagnostic certainty, and patient satisfaction with telemedicine eye screening using a novel handheld fundus camera in a rural and medically underserved population. METHODS: This prospective study included 176 eyes from a remote island. All participants underwent a comprehensive ophthalmic examination. Nonmydriatic retinal images obtained using a handheld fundus camera were reviewed by two retinal specialists to determine image quality, diagnosis, and need for referrals. The agreement of diagnosis between image-based assessments was compared with that of binocular indirect ophthalmoscopic assessments. RESULTS: Image quality of fundus photographs was considered acceptable or ideal in 97.7% and 95.5% of eyes assessed by two reviewers, respectively. There was considerable agreement in diagnosis between the indirect ophthalmoscopic assessment and image-based assessment by two reviewers (Cohen's kappa = 0.80 and 0.78, respectively). Likewise, substantial agreement was achieved in the referrals. The sensitivity for referable retinopathy from the two reviewers was 78% (95% confidence interval [CI], 57%-91%) and 78% (95% CI, 57%-91%), whereas specificity was 99% (95% CI, 95%-99%] and 98% (95% CI, 93%-99%), respectively. For physicians' perceived certainty of diagnosis, 93.8% and 90.3% were considered either certain or reliable. Overall, 97.4% of participants were satisfied with their experiences and greatly valued the telemedicine services. CONCLUSION: Novel fundus camera-based telemedicine screening demonstrated high accuracy in detecting clinically significant retinopathy in real-world settings. It achieved high patient satisfaction and physician-perceived certainty in diagnosis with reliable image quality, which may be scaled internationally to overcome geographical barriers under the global pandemic.


Assuntos
Retinopatia Diabética , Oftalmologia , Médicos , Doenças Retinianas , Telemedicina , Retinopatia Diabética/diagnóstico por imagem , Humanos , Estudos Prospectivos , Telemedicina/métodos
3.
Medicine (Baltimore) ; 100(48): e27793, 2021 Dec 03.
Artigo em Inglês | MEDLINE | ID: mdl-35049178

RESUMO

RATIONALE: Proliferative diabetic retinopathy (PDR) may lead to severe visual impairment, and visual field (VF) loss in such patients has been reported. Vitrectomy is performed in PDR cases complicated with either vitreous hemorrhage or tractional retinal detachment to restore their visual acuity. However, its effect on VF defects is limited in data. Herein, we report the recovery of VF defects following vitrectomy in a patient with PDR. PATIENT CONCERNS: A 25-year-old female with bilateral PDR and vitreous hemorrhage received 2 monthly intravitreal injections of aflibercept in both eyes. Six months after her last injection, she presented with fibrovascular membrane formation in both eyes and VF defects of -9.02 dB and -20.05 dB in the right and left eye, respectively. DIAGNOSES: Proliferative diabetic retinopathy in both eyes. INTERVENTIONS: The patient underwent vitrectomy for her left eye. OUTCOMES: Although her visual acuity did not improve as expected, results from the Humphrey visual field analyzer showed notably improvement of her left eye (-9.05 dB) after the surgery. LESSONS: Vitrectomy potentially allows recovery of VF defects in patients with PDR.


Assuntos
Diabetes Mellitus , Retinopatia Diabética/cirurgia , Vitrectomia/métodos , Hemorragia Vítrea/cirurgia , Adulto , Retinopatia Diabética/complicações , Feminino , Humanos , Resultado do Tratamento , Transtornos da Visão/etiologia , Acuidade Visual , Campos Visuais , Hemorragia Vítrea/etiologia
4.
J Chin Med Assoc ; 84(1): 108-113, 2021 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-32947505

RESUMO

BACKGROUND: To evaluate the effectiveness and safety of the XEN45 Gel Stent in East Asian patients with primary open angle glaucoma (POAG). METHODS: We retrospectively reviewed 37 medically uncontrolled POAG patients who received XEN45 Gel Stent. The primary outcomes were reduction in intraocular pressure (IOP) and in the number of glaucoma medications 12 months after surgery. The secondary outcomes were requirement for intervention and further glaucoma surgery. The adverse intraoperative and postoperative events were investigated. RESULTS: At the 12-month postoperative follow-up, the mean IOP was significantly reduced from the preoperative value of 21.7 ± 7.7 mmHg to 15.0 ± 2.0 mmHg (p = 0.001). The mean number of glaucoma medications decreased from 3.4 ± 0.9 to 1.3 ± 1.5 (p < 0.001). Seventeen patients (45.9%) required postoperative interventions. Four patients (10.8%) received additional glaucoma surgery. Postoperative IOP at month 1 was significantly associated with outcomes at the 12-month follow-up and the need for subsequent intervention and additional glaucoma surgery. CONCLUSION: The XEN45 Gel Stent effectively reduced the IOP values and number of glaucoma medications in East Asian patients with POAG. No major complications were observed, but almost half of the eyes in the study required intervention for wound healing modification. Postoperative IOP at month 1 was a predictor of surgical success at 12 months after surgery.


Assuntos
Glaucoma de Ângulo Aberto/cirurgia , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Stents , Adulto , Idoso , Feminino , Humanos , Pressão Intraocular , Masculino , Pessoa de Meia-Idade , Procedimentos Cirúrgicos Minimamente Invasivos/efeitos adversos , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA