1.
J Vasc Interv Radiol ; 31(10): 1691-1696.e1, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32178944

RESUMO

PURPOSE: To characterize the effect of hepatic vessel flow using 4-dimensional (4D) flow magnetic resonance (MR) imaging and correlate their effect on microwave ablation volumes in an in vivo non-cirrhotic porcine liver model. MATERIALS AND METHODS: Microwave ablation antennas were placed under ultrasound guidance in each liver lobe of swine (n = 3 in each animal) for a total of 9 ablations. Pre- and post-ablation 4D flow MR imaging was acquired to quantify flow changes in the hepatic vasculature. Flow measurements, along with encompassed vessel size and vessel-antenna spacing, were then correlated with final ablation volume from segmented MR images. RESULTS: The linear regression model demonstrated that the preablation measurement of encompassed hepatic vein size (ß = -0.80 ± 0.25, 95% confidence interval [CI] -1.15 to -0.22; P = .02) was significantly correlated to final ablation zone volume. The addition of hepatic vein flow rate found via 4D flow MRI (ß = -0.83 ± 0.65, 95% CI -2.50 to 0.84; P = .26), and distance from antenna to hepatic vein (ß = 0.26 ± 0.26, 95% CI -0.40 to 0.92; P = .36) improved the model accuracy but not significantly so (multivariate adjusted R2 = 0.70 vs univariate (vessel size) adjusted R2 = 0.63, P = .24). CONCLUSIONS: Hepatic vein size in an encompassed ablation zone was found to be significantly correlated with final ablation zone volume. Although the univariate 4D flow MR imaging-acquired measurements alone were not found to be statistically significant, its addition to hepatic vein size improved the accuracy of the ablation volume regression model. Pre-ablation 4D flow MR imaging of the liver may assist in prospectively optimizing thermal ablation treatment.


Assuntos
Técnicas de Ablação , Veias Hepáticas/diagnóstico por imagem , Circulação Hepática , Fígado/irrigação sanguínea , Fígado/cirurgia , Imagem Cinética por Ressonância Magnética , Micro-Ondas , Imagem de Perfusão/métodos , Animais , Velocidade do Fluxo Sanguíneo , Estudos de Viabilidade , Veias Hepáticas/fisiopatologia , Modelos Animais , Valor Preditivo dos Testes , Sus scrofa
2.
Magn Reson Imaging ; 26(3): 426-32, 2008 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-17826943

RESUMO

The focus of this report was to test the performance of a novel piezoelectric motor under high magnetic field strength conditions and to investigate its potential applications in small animal magnetic resonance imaging (MRI). The device is made entirely of nonferrous materials and consists of four piezoelectric ceramic plates connected to a threaded metal tube through which a screw migrates. Ultrasonic vibrations of the threads inherent to the tube result in rotational and translational motion of the screw. Potential applications of the piezoelectric motor were investigated at 4.7 T. Firstly, phantom studies showed the motor was capable of accurately delivering low injection volumes ( approximately 0.01 ml). Dynamic contrast-enhanced MRI (DCE-MRI) studies performed in vivo using serially acquired T1-weighted, spin-echo imaging demonstrated the ability of the motor to reliably administer MR contrast-enhancing agent into live tumor-bearing mice without the introduction of image artifacts. In a second set of experiments, the motor allowed for controlled, dynamic repositioning of an anatomic slice of interest in a live animal to magnetic field isocenter, which resulted in reduced geometric distortion and image artifact due to improved radiofrequency and gradient field homogeneity. In conclusion, piezoelectric motors are MR compatible and offer great potential for improving MRI efficiency and throughput, particularly in a preclinical setting. Further investigation into applications such as automated capacitor tuning and impedance matching for MR transceiver coils is warranted.


Assuntos
Fontes de Energia Elétrica , Imageamento por Ressonância Magnética/instrumentação , Animais , Carcinoma Pulmonar de Células não Pequenas/patologia , Cerâmica , Meios de Contraste , Desenho de Equipamento , Análise de Falha de Equipamento , Feminino , Gadolínio DTPA , Neoplasias Pulmonares/patologia , Camundongos , Camundongos Nus , Imagens de Fantasmas , Transplante Heterólogo