Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Ann Thorac Surg ; 115(6): 1403-1410, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-35643333

RESUMO

BACKGROUND: Valve-sparing aortic root replacement with the David procedure is an alternative to the Bentall procedure in patients with aortic root aneurysm. The aim of this study was to describe our long-term experience with this technique and the predictive factors of late failure. METHODS: Between January 1998 and August 2019, 300 consecutive patients underwent a David procedure. Clinical and echocardiographic early- and long-term outcomes were analyzed. Median follow-up was 7.0 years (range, 4.1-11.5), with 98.3% complete. RESULTS: Early mortality was 1%. No early valve-related reoperations occurred. There were 9 cardiac-related deaths and 22 reinterventions (19 valve-related). All patients survived reoperation. In 3 patients reintervention consisted of transcatheter aortic valve implantation. Overall survival rates were 95.3% (95% confidence interval [CI], 92.0-97.2), 91.1% (95% CI, 86.5-94.2), and 82.9% (95% CI, 75.3-88.4) at 5, 10, and 15 years, respectively. Freedom from postoperative aortic insufficiency (AI) grade ≥ 2 was 84.8% (95% CI, 79.9-88.6) and 74.3% (95% CI, 67.4-79.9) at 5 and 10 years, respectively. Freedom from reintervention for aortic valve disease was 97.1% (95% CI, 94.2-98.5), 92.9% (95% CI, 88.2-95.7), and 92.5% (95% CI, 87.1-95.7) at 5, 10, and 15 years, respectively. Preoperative AI ≥ 2 (hazard ratio, 1.782; 95% CI, 1.352-2.350) and a ventriculoaortic junction ≥ 29 mm (hazard ratio, 3.379; 95% CI, 1.726-6.616) were predictive factors for postoperative AI ≥ 2 in a multivariate analysis (P < .001). CONCLUSIONS: Preoperative AI ≥ 2 and a ventriculoaortic junction ≥ 29 mm were identified as risk factors for late postoperative AI ≥ 2.


Assuntos
Insuficiência da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Humanos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Resultado do Tratamento , Estudos Retrospectivos , Insuficiência da Valva Aórtica/etiologia , Aorta/cirurgia , Reoperação/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos
2.
Heart Lung Circ ; 31(1): e1-e4, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34600813

RESUMO

Minimally invasive cardiac surgery is mainly dedicated to acquired left-sided valve diseases. Ministernotomy is widely used for aortic valve repair or replacement, whereas pulmonary valve repair via this approach has been reported only recently. This article aims to describe the use of ministernotomy for pulmonary valve replacement in adult congenital patients.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Implante de Prótese de Valva Cardíaca , Valva Pulmonar , Adulto , Humanos , Procedimentos Cirúrgicos Minimamente Invasivos , Valva Pulmonar/diagnóstico por imagem , Valva Pulmonar/cirurgia , Resultado do Tratamento
3.
J Card Surg ; 35(5): 981-987, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-32176383

RESUMO

BACKGROUND: After an emergent surgery for type A acute aortic syndrome, medical management is based on optimal blood pressure (BP) control. We assessed the prognostic significance of BP monitoring and its relationship with aortic morphology following type A acute aortic syndrome. METHODS: The data of 120 patients who underwent BP monitoring after a type A acute aortic syndrome from January 2005 to June 2016 were retrospectively collected. The first CT angiogram performed after surgery was used for the morphological analysis. RESULTS: The population included 79 males, with an overall mean age of 60 ± 12 years. Seven patients (5.8%) died during a median follow-up of 5.5 years. The median delay between BP monitoring and discharge was 3 (1-5) months. The mean 24-hour BP of the cohort was 127/73 mm Hg ± 10/17. During follow-up, different parameters of BP monitoring were not associated with the risk of aortic events. However, the diameter of the false lumen of the descending thoracic aorta was the best predictor associated with the risk of new aortic events during follow-up, particularly for the threshold of 28 mm or more (P < .001; Hazard ratio 4.7[2.7-8.2]). The diameter of the false lumen was associated with night-time systolic BP (P = .025; r = .2), 24-hour pulse pressure (P = .002; r = .28), and night-time pulse pressure (P = .008; r = .24). CONCLUSION: The risk of new aortic events following type A acute aortic syndrome is associated with the size of the residual false lumen, but not directly with BP parameters. Night-time BP parameters are associated with the size of the residual false lumen.


Assuntos
Aorta Torácica/diagnóstico por imagem , Aorta Torácica/patologia , Dissecção Aórtica/patologia , Dissecção Aórtica/fisiopatologia , Monitorização Ambulatorial da Pressão Arterial , Pressão Sanguínea , Idoso , Dissecção Aórtica/diagnóstico por imagem , Aorta , Angiografia por Tomografia Computadorizada , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Prognóstico , Estudos Retrospectivos , Risco
4.
Ann Thorac Surg ; 110(3): 856-861, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32084372

RESUMO

BACKGROUND: The best valvular substitute remains controversial in young adults with active aortic valve endocarditis. The Ross procedure has gained interest because of its theoretical resistance to infection. We aimed to report our long-term outcomes of the Ross procedure in this indication. METHODS: Between March 1992 and January 2019, 511 patients underwent a Ross procedure in our institution. Among them, we included 38 patients who suffered from an active aortic valve infective endocarditis. The mean age was 33.9 ± 8.1 years. Six patients had emergent procedures and 17 patients had perivalvular involvement. A pulmonary autograft was implanted using the full root technique in 78.9% of patients. Median follow-up was 12 (interquartile range, 1.75-16.25) years. RESULTS: The hospital mortality rate was 5.3%. Estimated overall survival was 84.2% ± 6.6% at 10 years. There were 2 cases of recurrent endocarditis, both requiring reoperation. Six other patients required reoperation on an autograft or homograft. Estimated freedom from recurrent endocarditis or reoperation was 89.4% ± 5.9% at 10 years. CONCLUSIONS: In experienced centers, the Ross procedure is a reliable alternative to prosthetic or homograft valve replacement in young adults experiencing active aortic valve endocarditis, with a low operative risk and good long-term results.


Assuntos
Valva Aórtica/diagnóstico por imagem , Endocardite/cirurgia , Previsões , Implante de Prótese de Valva Cardíaca/efeitos adversos , Adolescente , Adulto , Valva Aórtica/cirurgia , Endocardite/diagnóstico , Endocardite/epidemiologia , Feminino , Seguimentos , França/epidemiologia , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/cirurgia , Reoperação , Estudos Retrospectivos , Taxa de Sobrevida/tendências , Resultado do Tratamento , Adulto Jovem
5.
N Engl J Med ; 375(4): 335-44, 2016 Jul 28.
Artigo em Inglês | MEDLINE | ID: mdl-27464202

RESUMO

BACKGROUND: Postprocedural aortic regurgitation occurs in 10 to 20% of patients undergoing transcatheter aortic-valve replacement (TAVR) for aortic stenosis. We hypothesized that assessment of defects in high-molecular-weight (HMW) multimers of von Willebrand factor or point-of-care assessment of hemostasis could be used to monitor aortic regurgitation during TAVR. METHODS: We enrolled 183 patients undergoing TAVR. Patients with aortic regurgitation after the initial implantation, as identified by means of transesophageal echocardiography, underwent additional balloon dilation to correct aortic regurgitation. HMW multimers and the closure time with adenosine diphosphate (CT-ADP), a point-of-care measure of hemostasis, were assessed at baseline and 5 minutes after each step of the procedure. Mortality was evaluated at 1 year. A second cohort (201 patients) was studied to validate the use of CT-ADP in order to identify patients with aortic regurgitation. RESULTS: After the initial implantation, HMW multimers normalized in patients without aortic regurgitation (137 patients). Among the 46 patients with aortic regurgitation, normalization occurred in 20 patients in whom additional balloon dilation was successful but did not occur in the 26 patients with persistent aortic regurgitation. A similar sequence of changes was observed with CT-ADP. A CT-ADP value of more than 180 seconds had sensitivity, specificity, and negative predictive value of 92.3%, 92.4%, and 98.6%, respectively, for aortic regurgitation, with similar results in the validation cohort. Multivariable analyses showed that the values for HMW multimers and CT-ADP at the end of TAVR were each associated with mortality at 1 year. CONCLUSIONS: The presence of HMW-multimer defects and a high value for a point-of-care hemostatic test, the CT-ADP, were each predictive of the presence of aortic regurgitation after TAVR and were associated with higher mortality 1 year after the procedure. (Funded by Lille 2 University and others; ClinicalTrials.gov number, NCT02628509.).


Assuntos
Difosfato de Adenosina/sangue , Insuficiência da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Complicações Pós-Operatórias/diagnóstico , Substituição da Valva Aórtica Transcateter , Fator de von Willebrand/análise , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/sangue , Estenose da Valva Aórtica/mortalidade , Biomarcadores/sangue , Feminino , Hemostasia/fisiologia , Humanos , Masculino , Análise Multivariada , Testes Imediatos , Complicações Pós-Operatórias/sangue , Curva ROC , Sensibilidade e Especificidade , Fator de von Willebrand/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA