Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J Neural Eng ; 19(1)2022 02 22.
Artigo em Inglês | MEDLINE | ID: mdl-35120337

RESUMO

Objective. High frequency oscillations (HFOs) recorded by intracranial electrodes have generated excitement for their potential to help localize epileptic tissue for surgical resection. However, the number of HFOs per minute (i.e. the HFO 'rate') is not stable over the duration of intracranial recordings; for example, the rate of HFOs increases during periods of slow-wave sleep. Moreover, HFOs that are predictive of epileptic tissue may occur in oscillatory patterns due to phase coupling with lower frequencies. Therefore, we sought to further characterize between-seizure (i.e. 'interictal') HFO dynamics both within and outside the seizure onset zone (SOZ).Approach. Using long-term intracranial EEG (mean duration 10.3 h) from 16 patients, we automatically detected HFOs using a new algorithm. We then fit a hierarchical negative binomial model to the HFO counts. To account for differences in HFO dynamics and rates between sleep and wakefulness, we also fit a mixture model to the same data that included the ability to switch between two discrete brain states that were automatically determined during the fitting process. The ability to predict the SOZ by model parameters describing HFO dynamics (i.e. clumping coefficients and coefficients of variation) was assessed using receiver operating characteristic curves.Main results. Parameters that described HFO dynamics were predictive of SOZ. In fact, these parameters were found to be more consistently predictive than HFO rate. Using concurrent scalp EEG in two patients, we show that the model-found brain states corresponded to (1) non-REM sleep and (2) awake and rapid eye movement sleep. However the brain state most likely corresponding to slow-wave sleep in the second model improved SOZ prediction compared to the first model for only some patients.Significance. This work suggests that delineation of SOZ with interictal data can be improved by the inclusion of time-varying HFO dynamics.


Assuntos
Epilepsia , Convulsões , Biomarcadores , Eletrocorticografia , Eletroencefalografia/métodos , Epilepsia/cirurgia , Humanos , Convulsões/diagnóstico
2.
Epilepsia ; 61(8): 1553-1569, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32729943

RESUMO

High-frequency oscillations (HFOs) in intracranial electroencephalography (EEG) are a promising biomarker of the epileptogenic zone and tool for surgical planning. Many studies have shown that a high rate of HFOs (number per minute) is correlated with the seizure-onset zone, and complete removal of HFO-generating brain regions has been associated with seizure-free outcome after surgery. In order to use HFOs as a biomarker, these transient events must first be detected in electrophysiological data. Because visual detection of HFOs is time-consuming and subject to low interrater reliability, many automated algorithms have been developed, and they are being used increasingly for such studies. However, there is little guidance on how to select an algorithm, implement it in a clinical setting, and validate the performance. Therefore, we aim to review automated HFO detection algorithms, focusing on conceptual similarities and differences between them. We summarize the standard steps for data pre-processing, as well as post-processing strategies for rejection of false-positive detections. We also detail four methods for algorithm testing and validation, and we describe the specific goal achieved by each one. We briefly review direct comparisons of automated algorithms applied to the same data set, emphasizing the importance of optimizing detection parameters. Then, to assess trends in the use of automated algorithms and their potential for use in clinical studies, we review evidence for the relationship between automatically detected HFOs and surgical outcome. We conclude with practical recommendations and propose standards for the selection, implementation, and validation of automated HFO-detection algorithms.


Assuntos
Algoritmos , Encéfalo/fisiopatologia , Eletrocorticografia/tendências , Epilepsia/diagnóstico , Processamento de Sinais Assistido por Computador , Artefatos , Mapeamento Encefálico , Ondas Encefálicas , Eletroencefalografia/tendências , Epilepsia/fisiopatologia , Humanos , Reprodutibilidade dos Testes
3.
Epilepsia Open ; 5(2): 263-273, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32524052

RESUMO

OBJECTIVE: High-frequency oscillations (HFOs) are a promising biomarker for the epileptogenic zone. However, no physiological definition of an HFO has been established, so detection relies on the empirical definition of an HFO derived from visual observation. This can bias estimates of HFO features such as amplitude and duration, thereby hindering their utility as biomarkers. Therefore, we set out to develop an algorithm that detects high-frequency events in the intracranial EEG that are morphologically distinct from background without requiring assumptions about event amplitude or shape. METHOD: We propose the anomaly detection algorithm (ADA), which uses unsupervised machine learning to identify segments of data that are distinct from the background. We apply ADA and a standard HFO detector using a root mean square amplitude threshold to intracranial EEG from 11 patients undergoing evaluation for epilepsy surgery. The rate, amplitude, and duration of the detected events and the percent overlap between the two detectors are compared. RESULT: In the seizure onset zone (SOZ), ADA detected a subset of conventional HFOs. In non-SOZ channels, ADA detected at least twice as many events as the standard approach, including some conventional HFOs; however, ADA also identified many low and intermediate amplitude events missed by the standard amplitude-based method. The rate of ADA events was similar across all channels; however, the amplitude of ADA events was significantly higher in SOZ channels (P < .0045), and the amplitude measurement was more stable over time than the HFO rate, as indicated by a lower coefficient of variation (P < .0125). SIGNIFICANCE: ADA does not require human supervision, parameter optimization, or prior assumptions about event shape, amplitude, or duration. Our results suggest that the algorithm's estimate of event amplitude may differentiate SOZ and non-SOZ channels. Further studies will examine the utility of HFO amplitude as a biomarker for epilepsy surgical outcome.

4.
J Neural Eng ; 13(2): 026031, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26975603

RESUMO

OBJECTIVE: Quantifying the relationship between microelectrode-recorded multi-unit activity (MUA) and local field potentials (LFPs) in distinct brain regions can provide detailed information on the extent of functional connectivity in spatially widespread networks. These methods are common in studies of cognition using non-human animal models, but are rare in humans. Here we applied a neuronal spike-triggered impulse response to electrophysiological recordings from the human epileptic brain for the first time, and we evaluate functional connectivity in relation to brain areas supporting the generation of seizures. APPROACH: Broadband interictal electrophysiological data were recorded from microwires adapted to clinical depth electrodes that were implanted bilaterally using stereotactic techniques in six presurgical patients with medically refractory epilepsy. MUA and LFPs were isolated in each microwire, and we calculated the impulse response between the MUA on one microwire and the LFPs on a second microwire for all possible MUA/LFP pairs. Results were compared to clinical seizure localization, including sites of seizure onset and interictal epileptiform discharges. MAIN RESULTS: We detected significant interictal long-range functional connections in each subject, in some cases across hemispheres. Results were consistent between two independent datasets, and the timing and location of significant impulse responses reflected anatomical connectivity. However, within individual subjects, the spatial distribution of impulse responses was unique. In two subjects with clear seizure localization and successful surgery, the epileptogenic zone was associated with significant impulse responses. SIGNIFICANCE: The results suggest that the spike-triggered impulse response can provide valuable information about the neuronal networks that contribute to seizures using only interictal data. This technique will enable testing of specific hypotheses regarding functional connectivity in epilepsy and the relationship between functional properties and imaging findings. Beyond epilepsy, we expect that the impulse response could be more broadly applied as a measure of long-range functional connectivity in studies of cognition.


Assuntos
Potenciais de Ação/fisiologia , Encéfalo/fisiopatologia , Epilepsia/fisiopatologia , Rede Nervosa/fisiopatologia , Neurônios/fisiologia , Adulto , Mapeamento Encefálico/métodos , Epilepsia/diagnóstico , Feminino , Humanos , Masculino , Microeletrodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA