RESUMO
OBJECTIVES: To localize and quantify mitral calcification associated with severe aortic stenosis and severe mitral regurgitation and determine its association with cardiac remodeling, operative management, and long-term survival. METHODS: From July 1998 to July 2010, 158 patients with severe aortic stenosis, severe mitral regurgitation, and mitral calcification underwent surgical aortic valve replacement (SAVR, n=49) or SAVR plus mitral valve repair (SAVR+MVr, n=67) or replacement (SAVR+MVR, n=42). Mitral calcium was localized and quantified on preoperative computed tomography. Random forest methodology was used to correlate calcium volume with cardiac morphology and function. Median follow-up for survival was 4.1 years; 25% were followed ≥14 years. RESULTS: Larger calcium volume was associated with degenerative mitral disease, higher ejection fraction, smaller left ventricular end-systolic volume, and SAVR+MVR (median calcium volume 3.4 cm3) versus SAVR (median calcium volume 1.0 cm3) or SAVR+MVr (median calcium volume 0.41 cm3). Ten-year mortality was higher in patients with more mitral calcification (terciles: 7.1% vs 16% vs 25%), subvalvular involvement (8.1% vs 18%), and SAVR+MVR (5.4% vs SAVR=13% vs SAVR+MVr=26%). Multivariable analysis demonstrated early postoperative mortality was strongly associated with subvalvular mitral calcification, but late mortality was not associated with calcium volume or location. CONCLUSIONS: Larger mitral calcium volume is a marker of late-stage cardiac remodeling associated with more extensive mitral valve intervention, but it is not associated with long-term mortality. Quantitative analysis of mitral calcification with computed tomography can aid in patient selection and surgical management decisions in this complex patient population.
RESUMO
BACKGROUND: Open approaches for esophagectomy are often still useful; of these, left thoracoabdominal esophagectomy (TAE) is poorly understood and often criticized. Hence, we examined TAE's worldwide utilization, survival, and present-day use and outcomes at our institution compared with contemporary national averages. METHODS: The Worldwide Esophageal Cancer Collaboration database includes 8854 patients who underwent esophagectomy for cancer between 2005 and 2014, a period when TAE was our center's most common approach. Two propensity score-matched models were constructed: worldwide TAE vs worldwide non-TAE (751 matched pairs); and our high-volume center TAE vs worldwide non-TAE (273 matched pairs). All-cause mortality was compared between matched groups. Institutional TAE data from 2017 to 2021 were assessed for present-day use and outcomes. RESULTS: Worldwide, propensity score-matched patients undergoing TAE had a median of 20 lymph nodes resected vs 17 after non-TAE (P < .0001). Five-year survival was 34% for worldwide TAE vs 42% for worldwide non-TAE groups (P = .04). Three-year matched survival was 52% for high-volume TAE compared with 54% for worldwide non-TAE groups (P = .1). From 2017 to 2021 at our institution, 90 (26%) of 346 esophagectomies were performed by TAE. Pneumonia developed in 5 patients (5.6%), with 88 patients (98%) alive at 30 days, comparable to contemporary averages of The Society of Thoracic Surgeons. CONCLUSIONS: When it is performed as the primary approach in high volumes, TAE can have comparable outcomes to non-TAE with low morbidity. At present, we find that TAE is most useful in patients with truncal obesity, prior abdominal operations, and locally advanced cardia tumors with potential for variable extent of resection.
Assuntos
Neoplasias Esofágicas , Esofagectomia , Humanos , Esofagectomia/métodos , Masculino , Neoplasias Esofágicas/cirurgia , Neoplasias Esofágicas/mortalidade , Feminino , Pessoa de Meia-Idade , Idoso , Pontuação de Propensão , Estudos Retrospectivos , Taxa de Sobrevida/tendênciasRESUMO
OBJECTIVE: The objectives of this study were to investigate patient characteristics, valve pathology, bacteriology, and surgical techniques related to outcome of patients who underwent surgery for isolated native (NVE) or prosthetic (PVE) mitral valve endocarditis. METHODS: From January 2002 to January 2020, 447 isolated mitral endocarditis operations were performed, 326 for NVE and 121 for PVE. Multivariable analysis of time-related outcomes used random forest machine learning. RESULTS: Staphylococcus aureus was the most common causative organism. Of 326 patients with NVE, 88 (27%) underwent standard mitral valve repair, 43 (13%) extended repair, and 195 (60%) valve replacement. Compared with NVE with standard repair, patients who underwent all other operations were older, had more comorbidities, worse cardiac function, and more invasive disease. Hospital mortality was 3.8% (n = 17); 0 (0%) after standard valve repair, 3 (7.0%) after extended repair, 8 (4.1%) after NVE replacement, and 6 (5.0%) after PVE re-replacement. Survival at 1, 5, and 10 years was 91%, 75%, and 62% after any repair and 86%, 62%, and 44% after replacement, respectively. The most important risk factor for mortality was renal failure. Risk-adjusted outcomes, including survival, were similar in all groups. Unadjusted extended repair outcomes, particularly early, were similar or worse than replacement in terms of reinfection, reintervention, regurgitation, gradient, and survival. CONCLUSIONS: A patient- and pathology-tailored approach to surgery for isolated mitral valve endocarditis has low mortality and excellent results. Apparent superiority of standard valve repair is related to patient characteristics and pathology. Renal failure is the most powerful risk factor. In case of extensive destruction, extended repair shows no benefit over replacement.
Assuntos
Endocardite Bacteriana , Endocardite , Infecções Relacionadas à Prótese , Insuficiência Renal , Humanos , Endocardite Bacteriana/diagnóstico , Endocardite Bacteriana/cirurgia , Endocardite Bacteriana/microbiologia , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Valva Mitral/microbiologia , Valva Aórtica/cirurgia , Infecções Relacionadas à Prótese/diagnóstico , Infecções Relacionadas à Prótese/cirurgia , Infecções Relacionadas à Prótese/microbiologia , Endocardite/patologia , Resultado do TratamentoRESUMO
OBJECTIVES: Bicuspid aortic valve (BAV) aortopathy is defined by 3 phenotypes-root, ascending, and diffuse-based on region of maximal aortic dilation. We sought to determine the association between aortic mechanical behavior and aortopathy phenotype versus other clinical variables. METHODS: From August 1, 2016, to March 1, 2023, 375 aortic specimens were collected from 105 patients undergoing elective ascending aortic aneurysm repair for BAV aortopathy. Planar biaxial data (191 specimens) informed constitutive descriptors of the arterial wall that were combined with in vivo geometry and hemodynamics to predict stiffness, stress, and energy density under physiologic loads. Uniaxial testing (184 specimens) evaluated failure stretch and failure Cauchy stress. Boosting regression was implemented to model the association between clinical variables and mechanical metrics. RESULTS: There were no significant differences in mechanical metrics between the root phenotype (N = 33, 31%) and ascending/diffuse phenotypes (N = 72, 69%). Biaxial testing demonstrated older age was associated with increased circumferential stiffness, decreased stress, and decreased energy density. On uniaxial testing, longitudinally versus circumferentially oriented specimens failed at significantly lower Cauchy stress (50th [15th, 85th percentiles]: 1.0 [0.7, 1.6] MPa vs 1.9 [1.3, 3.1] MPa; P < .001). Age was associated with decreased failure stretch and stress. Elongated ascending aortas were also associated with decreased failure stress. CONCLUSIONS: Aortic mechanical function under physiologic and failure conditions in BAV aortopathy is robustly associated with age and poorly associated with aortopathy phenotype. Data suggesting that the root phenotype of BAV aortopathy portends worse outcomes are unlikely to be related to aberrant, phenotype-specific tissue mechanics.
RESUMO
OBJECTIVES: We evaluate the independent effects of patient and aortic tissue characteristics on biaxial physiologic mechanical metrics in aneurysmal and nonaneurysmal tissues, and uniaxial failure metrics in aneurysmal tissue, comparing longitudinal and circumferential behavior. METHODS: From February 2017 to October 2022, 382 aortic specimens were collected from 134 patients; 268 specimens underwent biaxial testing, and 114 specimens underwent uniaxial testing. Biaxial testing evaluated Green-Lagrange transition strain and low and high tangent moduli. Uniaxial testing evaluated failure stretch, Cauchy stress, and low and high tangent moduli. Longitudinal gradient boosting models were implemented to estimate mechanical metrics and covariates of importance. RESULTS: On biaxial testing, nonaneurysmal tissue was less deformable and exhibited a lower transition strain than aneurysmal tissue in the longitudinal (0.18 vs 0.30, P < .001) and circumferential (0.25 vs 0.30, P = .01) directions. Older age and increasing ascending aortic length contributed most to predicting transition strain. On uniaxial testing, longitudinal specimens failed at lower stretch (1.4 vs 1.5, P = .003) and Cauchy stress (1.0 vs 1.9 kPa, P < .001) than circumferential specimens. Failure stretch and Cauchy stress were most strongly associated with tissue orientation and decreased sharply with older age. Age, ascending aortic length, and tissue thickness were the most frequent covariates predicting mechanical metrics across 10 prediction models. CONCLUSIONS: Age was the strongest predictor of mechanical behavior. After adjusting for age, nonaneurysmal tissue was less deformable than aneurysmal tissue. Differences in longitudinal and circumferential mechanics contribute to tissue dysfunction and failure in ascending aneurysms. This highlights the need to better understand the effects of age, ascending aortic length, and thickness on clinical aortic behavior.
RESUMO
BACKGROUND: As risks of repairing the descending thoracic and thoracoabdominal aorta diminish, common complications that may prolong hospital stay, or actually increase risk, require attention. One such complication is postoperative atrial fibrillation (AF). Therefore, we characterized prevalence of, risk factors for, and effects of postoperative atrial fibrillation (PoAF) after descending and thoracoabdominal aorta repair. METHODS: From January 2000 to January 2011, 696 patients underwent open descending or thoracoabdominal aorta repair at Cleveland Clinic. Operations approached via median sternotomy (n = 178) and patients treated preoperatively for arrhythmias (32 amiodarone, 9 paced) or in AF on preoperative electrocardiogram (n = 14) were excluded, leaving 463. Logistic regression analysis identified risk factors for PoAF. Temporal relation of PoAF with postoperative morbidities was determined, and outcomes following PoAF were compared between propensity-matched pairs. RESULTS: New-onset PoAF occurred in 101 patients (22%) at a median 68 hours of postincision. Risk factors included older age (p = 0.002) and history of remote AF (p = 0.0004) but not operative details, such as pericardiotomy for cardiac cannulation. Hypoperfusion and neurologic complications tended to precede PoAF, whereas sepsis, respiratory failure, and dialysis followed. Among 94 propensity-matched patient pairs, those developing PoAF were more likely to experience hypoperfusion (p = 0.006), respiratory failure (p = 0.009), dialysis (p = 0.04), paralysis (p < 0.0001), longer intensive care unit stay (median 7 vs. 5 d, p = 0.02), and longer postoperative hospital stay (median 15 vs. 13 d, p = 0.004). However, hospital death was similar (6/94 PoAF [6.4%] vs. 7/94 no PoAF [7.4%], p = 0.8). CONCLUSION: PoAF after descending thoracic aorta surgery is relatively common and a part of a constellation of other serious complications prolonging postoperative recovery. While PoAF was associated with adverse events, it did not impact postoperative cost and mortality. Descending thoracic aorta surgery is by itself comorbid enough, which is likely why PoAF does not have a more significant effect on postoperative recovery and cost.
RESUMO
To characterize patient risk profiles and outcomes associated with staged ultra-hybrid repair of extensive aortic disease, in which open thoracoabdominal completion was performed after thoracic stent grafting. From 1/2006 to 1/2021, 92 patients underwent open thoracoabdominal repair of chronic dissection (n=58, 63%), degenerative aneurysm (n=28, 30%), endoleak (n=4, 4.3%), or symptomatic acute type B dissection (n=2, 2.2%) after descending thoracic stent grafting (69, 75%), frozen elephant trunk (5, 5%), or both (18, 20%). The surgical graft was sewn to the distal endovascular device in situ, reducing the extent of the open procedure and eliminating the need for hypothermic circulatory arrest. Mean age was 58±13 years, 89 (97%) were hypertensive, 38 (43%) had chronic obstructive pulmonary disease, 63 (72%) were smokers, 20 (24%) had a prior stroke, and 33 (36%) had a suspected or confirmed heritable aortic condition. Hospital mortality was 7.6% (n=7). Complications included dialysis (16, 20%), tracheostomy (8, 8.7%), stroke (5, 5.7%), and permanent paralysis (6, 6.9%). Survival at 1, 3, and 5 years was 80%, 71%, and 66%, respectively. Mortality was associated with higher blood urea nitrogen and longer distance between the distal endograft edge and proximal patent visceral vessel (P=0.004 and .01, respectively). Patients with extensive aortic disease undergoing open aortic repair after thoracic stent grafting are often young with chronic dissection, multiple comorbidities, or a heritable aortic condition. Success of staged ultra-hybrid operations demonstrates open and endovascular repair strategies are complementary, even when performed in a high-risk patient population.
RESUMO
OBJECTIVES: Reoperation for structural valve deterioration (SVD) of bioprosthetic mitral valves carries a presumed high operative risk, and transcatheter mitral valve-in-valve implantation has emerged as an alternative. However, surgical risk and long-term outcome following mitral valve re-replacement in these patients remain ill-defined. Hence, we sought to evaluate outcomes and long-term survival following surgical mitral valve re-replacement and to identify risk factors for mortality. METHODS: From January 1990 to January 2017, 525 patients underwent surgical mitral valve re-replacement at Cleveland Clinic for bioprosthetic SVD: 133 (25%) isolated operations and 392 (75%) with concomitant procedures. Surgical complications and modes of death were compiled, long-term mortality assessed, and risk factors identified using a multivariable nonproportional hazards model and random forest analysis. RESULTS: SVD was characterized by bioprosthetic regurgitation in 81% (425 out of 525) and stenosis in 44% (231 out of 525). One in-hospital death occurred after isolated valve re-replacement (0.75%) and 28 deaths occurred (7.1%; P = .003) after nonisolated re-replacement, 19 (68%) of which were from coagulopathy, vasoplegia, and multisystem organ failure. In the nonisolated group, incremental risk factors for time-related death after re-replacement included New York Heart Association functional class IV symptoms, concomitant coronary artery bypass grafting, prolonged cardiopulmonary bypass time, and transfusions. CONCLUSIONS: Mitral valve re-replacement for bioprosthetic SVD was associated with low surgical risk and excellent long-term survival. Isolated mitral valve re-replacement for bioprosthetic SVD had near-zero surgical risk. Excessive cardiopulmonary bypass duration and multiple transfusions correlated with increased early mortality in nonisolated procedures, as did preoperative severe heart failure. Optimal surgical plan and timing of surgery are keys to success.
Assuntos
Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Valva Aórtica/cirurgia , Bioprótese/efeitos adversos , Próteses Valvulares Cardíacas/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Mortalidade Hospitalar , Humanos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Reoperação/métodos , Estudos Retrospectivos , Resultado do TratamentoRESUMO
BACKGROUND: Patients undergoing surgery for thoracic aortic aneurysms receive statin therapy out of proportion to cardiovascular comorbidity. We sought to determine the prevalence of statin use among patients presenting for thoracic aortic aneurysm surgery and investigate its effect on outcomes. METHODS: From January 1, 2005 to January 1, 2011, 1,839 consecutive patients underwent aortic replacement for degenerative thoracic aortic aneurysm at Cleveland Clinic. Of these, 771 (42%) were on statins preoperatively. Statin users (vs. nonstatin users) were older (65 ± 11 vs. 56 ± 16 years) and had more hypertension (78 vs. 59%). Propensity matching based on 56 preoperative variables other than lipid levels was used to compare outcomes among 570 matched patient pairs (74% of possible pairs). RESULTS: Propensity-matched statin and nonstatin users were aged 64 ± 11 years, 394 (69%) versus 387 (68%) were male, and 437 (77%) versus 442 (78%) had ascending aortic aneurysms, respectively. Overall, 25% of patients were followed for more than 8.2 years and 10% for more than 10 years. Perioperative outcomes were similar, including hospital mortality (11 [1.9%] vs. 5 [0.88%]) and stroke (22 [3.9%] vs. 13 [2.3%]), but 16 statin users (2.8%) versus 5 nonstatin users (0.88%) required temporary dialysis after surgery (p = 0.02). At 6 years, 3.7% of statin users versus 5.1% of nonstatin users (p[log-rank] = 0.5) underwent further aortic surgery, and at 10 years, mortality was 25% in both groups (p > 0.5). CONCLUSION: Patients presenting for thoracic aortic aneurysm surgery frequently receive unnecessary statins. Additionally, statin use was associated with more postoperative renal failure, but not less intermediate-term risk for aortic reintervention or all-cause mortality after surgery. Therefore, presence of a thoracic aortic aneurysm should not be considered an indication for statin therapy in the absence of well-established indications.
RESUMO
BACKGROUND: Transfemoral access is the most common approach for transcatheter aortic valve replacement (TAVR). However, a subset of patients require alternative access. This study describes the evolution and outcomes of alternative-access TAVR at Cleveland Clinic. METHODS: From January 2006 to January 2019, 2446 patients underwent TAVR, 414 (17%) through alternative access (247 transapical, 95 transaortic, 56 transaxillary, 2 transcarotid, 10 transiliac, 4 transcaval). Patients undergoing alternative-access TAVR had high preoperative risk. Propensity-matched comparisons were targeted at comparing transfemoral versus transaxillary approaches since 2012. RESULTS: Over time, the favored alternative-access approach shifted from transapical and transaortic to transaxillary. Pacemaker requirement was similar for alternative-access and transfemoral approaches. Compared with transfemoral access, major vascular injuries were higher in the alternative-access group (12 [2.9%] vs 27 [1.3%], P = .02), but minor vascular injuries were lower (13 [3.1%] vs 198 [9.8%], P < .0001). Non-risk-adjusted 5-year survival was lower in the alternative-access group (45% vs 59%). Compared with intrathoracic approaches (transapical and transaortic), transaxillary access was associated with fewer blood transfusions (12 [21%] vs 176 [51%], P < .0001), less prolonged ventilation (1 [1.8%] vs 38 [11%], P = .03), and shorter length of stay (median, 5 vs 7.5 days, P < .0001). Survival and major morbidity were similar in matched comparisons of the transfemoral and transaxillary approaches. No brachial plexus injuries occurred with transaxillary access. CONCLUSIONS: The transaxillary approach has emerged as our preferred alternative-access strategy for TAVR. It is associated with superior operative outcomes compared with transthoracic approaches, and results are comparable with those of the transfemoral approach.
Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas , Medição de Risco/métodos , Cirurgia Assistida por Computador/métodos , Substituição da Valva Aórtica Transcateter/métodos , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/diagnóstico , Feminino , Fluoroscopia/métodos , Seguimentos , Humanos , Incidência , Masculino , Ohio/epidemiologia , Complicações Pós-Operatórias/epidemiologia , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do TratamentoRESUMO
OBJECTIVES: Repair outcomes of tricuspid regurgitation (TR) associated with ischaemic mitral regurgitation (IMR) are inferior to functional TR in terms of TR recurrence and right ventricular (RV) reverse remodelling. Our objective is to analyse right versus left heart reverse remodelling after surgery for IMR-associated TR. METHODS: From 2001 to 2011, 568 patients with severe IMR underwent mitral valve surgery (repair 87%, replacement 13%), and 131 had concomitant tricuspid valve repair. Median follow-up was 3.0 years; 25% of living patients were followed up for 6.3 years. Longitudinal analysis of 1527 follow-up echocardiograms was performed to assess ventricular reverse remodelling and function. RESULTS: Unlike the left heart, the right heart failed to reverse remodel (failed to recover ventricular function or halt dilatation). During follow-up after surgery, the right ventricle continued to dilate while the left ventricle regressed in size. RV ejection fraction decreased (46% at 1 month and 44% at 5 years), while left ventricular ejection fraction increased (33% and 37%, respectively). RV strain showed early (-11% at 1 month) and late (-12% at 5 years) dysfunction. Patients who underwent tricuspid valve repair had worse RV function. Mitral regurgitation remained stable after surgical intervention, and TR gradually recurred (37% moderate, 20% severe at 7 years). CONCLUSIONS: Surgical treatment of IMR and TR along with revascularization failed to induce reverse remodelling of the right heart. These findings warrant further investigations to identify optimal timing and approach of intervention for IMR-associated TR with respect to RV remodelling.
RESUMO
OBJECTIVE: The study objective was to determine whether adding prophylactic aorta replacement increases the risk of a cardiac operation when cardiac rather than aortic disease is the primary indication for operation. METHODS: Patients undergoing cardiac operations with aorta replacement (cardioaortic group), with or without circulatory arrest, were propensity matched to identify patients whose combined operation was not primarily indicated by aortic disease (n = 684). These patients were further propensity matched without accounting for thoracic-aortic measurements to patients undergoing cardiac operations without aorta replacement (cardiac-surgery only group), 647 pairs, for comparing outcomes. RESULTS: Most (n = 431/503 [86%]) propensity-matched patients undergoing cardioaortic operations had ascending aorta dilatation with a maximum aortic diameter of less than 5.5 cm. There was no evidence of an incremental increase in risk of in-hospital stroke (cardioaortic, n = 9/1.4% vs cardiac only, n = 7/1.1%; P = .6) or mortality (cardioaortic, n = 6/0.93% vs cardiac only, n = 3/0.46%; P = .5). Unmatched patients undergoing concomitant aortic surgery had advanced aortic disease distal to the ascending aorta (arch, 3.8 ± 0.98 cm vs 3.2 ± 0.51 cm; descending, 4.4 ± 1.7 cm vs 3.2 ± 0.99 cm) as the primary indication for their operation and had a high occurrence of in-hospital stroke (6.5% vs 1.5%, P = .0007) and death (7% vs 1.2%, P = .0001). CONCLUSIONS: Prophylactic aorta replacement can be safely performed during a cardioaortic operation, without added penalty, when aortic disease is less severe and not the primary indication for surgery. Risks after an aorta replacement combined with cardiac surgery can be substantial, however, when advanced aortic disease is the primary indication for operation. These distinctive risks should be taken into consideration at the time of surgical decision-making.
Assuntos
Aorta Torácica/cirurgia , Doenças da Aorta/cirurgia , Implante de Prótese Vascular , Procedimentos Cirúrgicos Cardíacos , Cardiopatias/cirurgia , Idoso , Aorta Torácica/diagnóstico por imagem , Doenças da Aorta/complicações , Doenças da Aorta/diagnóstico por imagem , Doenças da Aorta/mortalidade , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/mortalidade , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Procedimentos Cirúrgicos Cardíacos/mortalidade , Tomada de Decisão Clínica , Registros Eletrônicos de Saúde , Feminino , Cardiopatias/complicações , Cardiopatias/diagnóstico por imagem , Cardiopatias/mortalidade , Mortalidade Hospitalar , Humanos , Masculino , Pessoa de Meia-Idade , Seleção de Pacientes , Sistema de Registros , Medição de Risco , Fatores de Risco , Índice de Gravidade de Doença , Acidente Vascular Cerebral/mortalidade , Resultado do TratamentoRESUMO
OBJECTIVES: Multisite procedure-based randomized trials may be confounded by performance variability and variability among sites. Therefore, we studied variability in mortality and stroke after patients were randomized to surgical (SAVR) or transcatheter aortic valve replacement (TAVR) in the Placement of Aortic Transcatheter Valves-2A (PARTNER-2A) randomized trial. METHODS: Patients at intermediate risk for SAVR were randomized to SAVR (n = 1017) or TAVR (n = 1011) with a SAPIEN XT device (Edwards Lifesciences, Irvine, Calif) at 54 sites. Patients were followed to 2 years. A mixed-effect model quantified variability at intersite and intrasite levels. RESULTS: There were 336 deaths (SAVR 170, TAVR 166) and 176 strokes (SAVR 85, TAVR 91). Intersite variability for mortality was similar across sites for SAVR (hazard ratios ranging from 0.52-1.93 among sites) and TAVR (hazard ratios ranging from 0.49-2.03), but intersite variability for stroke was greater for SAVR (hazard ratios ranging from 0.44-2.26) than for TAVR (no detectable variability). Case mix and lower site trial volume accounted for 37% of mortality intersite variability for SAVR and 73% for TAVR, but only 14% for stroke for SAVR. Intrasite mortality hazard ratios demonstrated all but 1 site's 95% confidence interval overlapped 1.0, indicating generally similar SAVR and TAVR mortalities within sites. CONCLUSIONS: Intersite variability was similar for mortality in SAVR and TAVR, but variability for stroke was greater for SAVR than for TAVR. Intrasite events were similar for both SAVR and TAVR. These findings suggest that in performance-based trials, site variability and its sources should be taken into account in analyzing and interpreting trial results.
Assuntos
Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/cirurgia , Complicações Pós-Operatórias/etiologia , Acidente Vascular Cerebral/etiologia , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Canadá , Feminino , Humanos , Masculino , Fatores de Risco , Índice de Gravidade de Doença , Análise de Sobrevida , Estados UnidosRESUMO
OBJECTIVES: Consensus regarding initial cannulation site for acute type A dissection repair is lacking. Objectives were to review our experience with systematic initial axillary artery cannulation, characterize patients on the basis of cannulation site, and assess outcomes. METHODS: From January 2000 to January 2017, 775 patients underwent emergency acute type A dissection repair. Initial axillary cannulation was performed in 617 (80%), femoral in 93 (12%), and central in 65 (8.4%). In-hospital mortality and stroke risk factors were identified using logistic regression. RESULTS: Reasons for selecting initial central or femoral instead of axillary cannulation included unsuitable axillary anatomy (n = 67; 42%), surgeon preference (n = 38; 24%), hemodynamic instability (n = 34; 22%), and preexisting cannulation (n = 19; 12%). Cannulation site was shifted or added intraoperatively in 82 (11%), with initial cannulation site being axillary (n = 23 of 617; 3.7%), central (6 of 65; 9.2%), or femoral (n = 53 of 93; 57%), for surgeon preference (n = 60; 73%), high flow resistance (n = 13; 16%), increased aortic false lumen flow (n = 6; 7.3%), and other (n = 3; 3.7%). In-hospital mortality was 8.6% (n = 67; lowest for axillary, 7.3% [P = .02]) and stroke 8.3% (n = 64). Hemodynamic instability (odds ratio [OR], 7.6; 95% confidence interval [CI], 4.2-14), limb ischemia (OR, 3.7; 95% CI, 1.5-9.3), stroke (OR, 5.5; 95% CI, 2.2-14), and aortic regurgitation (OR, 2.2; 95% CI, 1.2-4.2) at presentation were risk factors for mortality and central cannulation site (OR, 2.3; 95% CI, 1.05-5.1) and aortic stenosis (OR, 2.4; 95% CI, 1.2-4.6) for stroke. CONCLUSIONS: Systematic initial axillary cannulation for acute type A dissection repair is safe and effective and can be tailored to patients' specific needs. With this strategy, comparable outcomes are observed among cannulation sites and are largely determined according to patient presentation rather than cannulation site.
Assuntos
Aneurisma Aórtico/cirurgia , Dissecção Aórtica/cirurgia , Artéria Axilar , Cateterismo Periférico , Procedimentos Endovasculares , Doença Aguda , Idoso , Dissecção Aórtica/mortalidade , Aneurisma Aórtico/mortalidade , Cateterismo Periférico/efeitos adversos , Cateterismo Periférico/mortalidade , Emergências , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/mortalidade , Feminino , Mortalidade Hospitalar , Humanos , Masculino , Pessoa de Meia-Idade , Punções , Medição de Risco , Fatores de Risco , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/mortalidade , Fatores de Tempo , Resultado do TratamentoRESUMO
OBJECTIVES: At a center where surgeons favor mitral valve (MV) repair for all subsets of leaflet prolapse, we compared results of patients undergoing repair for simple versus complex degenerative MV disease. METHODS: From January 1985 to January 2016, 6153 patients underwent primary isolated MV repair for degenerative disease, 3101 patients underwent primary isolated MV repair for simple disease (posterior prolapse), and 3052 patients underwent primary isolated MV repair for complex disease (anterior or bileaflet prolapse), based on preoperative echocardiographic images. Logistic regression analysis was used to generate propensity scores for risk-adjusted comparisons (n = 2065 matched pairs). Durability was assessed by longitudinal recurrence of mitral regurgitation and reoperation. RESULTS: Compared with patients with simple disease, those undergoing repair of complex pathology were more likely to be younger and female (both P values < .0001) but with similar symptoms (P = .3). The most common repair technique was ring/band annuloplasty (3055/99% simple vs 3000/98% complex; P = .5), followed by leaflet resection (2802/90% simple vs 2249/74% complex; P < .0001). Among propensity-matched patients, recurrence of severe mitral regurgitation 10 years after repair was 6.2% for simple pathology versus 11% for complex pathology (P = .007), reoperation at 18 years was 6.3% for simple pathology versus 11% for complex pathology, and 20-year survival was 62% for simple pathology versus 61% for complex pathology (P = .6). CONCLUSIONS: Early surgical intervention has become more common in patients with degenerative MV disease, regardless of valve prolapse complexity or symptom status. Valve repair was associated with similarly low operative risk and time-related survival but less durability in complex disease. Lifelong annual echocardiographic surveillance after MV repair is recommended, particularly in patients with complex disease.
Assuntos
Implante de Prótese Vascular , Anuloplastia da Valva Mitral , Insuficiência da Valva Mitral/cirurgia , Prolapso da Valva Mitral/cirurgia , Valva Mitral/cirurgia , Adulto , Idoso , Implante de Prótese Vascular/efeitos adversos , Ecocardiografia , Feminino , Hemodinâmica , Humanos , Masculino , Pessoa de Meia-Idade , Valva Mitral/diagnóstico por imagem , Valva Mitral/fisiopatologia , Anuloplastia da Valva Mitral/efeitos adversos , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/fisiopatologia , Prolapso da Valva Mitral/diagnóstico por imagem , Prolapso da Valva Mitral/fisiopatologia , Recuperação de Função Fisiológica , Recidiva , Fatores de Risco , Fatores de Tempo , Resultado do TratamentoRESUMO
BACKGROUND: Surgical outcomes of patients with chronic lymphocytic leukemia (CLL) undergoing cardiac surgery are limited. Our objectives were to investigate hospital morbidity and mortality after open cardiac surgery in CLL versus non-CLL patients. METHODS: From May 1995 to May 2015, 157 patients with CLL and 55,917 without and older than 47 years underwent elective cardiac surgery at Cleveland Clinic. By Rai criteria, 79 CLL patients (56%) were low risk (class 0), 13 (9.1%) intermediate risk (classes I and II), and 38 (27%) high risk (classes III and IV); 12 (8.5%) were in remission. Mean age of CLL patients was 72 ± 9.0 years, and 18% were women. CLL patients were propensity-score matched to 3 non-CLL patients to compare surgical outcomes. RESULTS: High-risk CLL patients received more blood products than matched non-CLL patients (33/38 [87%] versus 74/114 [65%], p = 0.01), but were less likely to receive cryoprecipitate (0% versus 15/114 [13%], p = .02). Intermediate-risk CLL patients received more platelet units, mean 12 versus 4.6 (p = 0.008). Occurrence of deep sternal wound infection (0% versus 5/471 [1.1%]), septicemia (5/157 [3.2%] versus 14/471 [3.0%]), and hospital mortality (4/157 [2.5%] versus 14/471 [3.0%]) were similar (p > 0.3), independent of prior chemotherapy treatment for CLL. CONCLUSIONS: Although CLL patients did not have higher hospital mortality than non-CLL patients, high-risk CLL patients were more likely to receive blood products. Risks associated with transfusion should be considered when evaluating CLL patients for elective cardiac surgery. Appropriate preoperative management, such as blood product transfusions, and alternative treatment options that decrease blood loss, should be considered for high-risk patients.
Assuntos
Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Cardiopatias/complicações , Cardiopatias/cirurgia , Leucemia Linfocítica Crônica de Células B/complicações , Idoso , Idoso de 80 Anos ou mais , Transfusão de Sangue , Estudos de Casos e Controles , Feminino , Cardiopatias/mortalidade , Mortalidade Hospitalar , Humanos , Leucemia Linfocítica Crônica de Células B/mortalidade , Leucemia Linfocítica Crônica de Células B/cirurgia , Masculino , Pessoa de Meia-Idade , Pontuação de PropensãoRESUMO
OBJECTIVE: The study objective was to assess the technical and process improvement and clinical outcomes of robotic mitral valve surgery by examining the first 1000 cases performed in a tertiary care center. METHODS: We reviewed the first 1000 patients (mean age, 56 ± 10 years) undergoing robotic primary mitral valve surgery, including concomitant procedures (n = 185), from January 2006 to November 2013. Mitral valve disease cause was degenerative (n = 960, 96%), endocarditis (n = 26, 2.6%), rheumatic (n = 10, 1.0%), ischemic (n = 3, 0.3%), and fibroelastoma (n = 1, 0.1%). All procedures were performed via right chest access with femoral perfusion for cardiopulmonary bypass. RESULTS: Mitral valve repair was attempted in 997 patients (2 planned replacements and 1 resection of fibroelastoma), 992 (99.5%) of whom underwent valve repair, and 5 (0.5%) of whom underwent valve replacement. Intraoperative postrepair echocardiography showed that 99.7% of patients receiving repair (989/992) left the operating room with no or mild mitral regurgitation, and predischarge echocardiography showed that mitral regurgitation remained mild or less in 97.9% of patients (915/935). There was 1 hospital death (0.1%), and 14 patients (1.4%) experienced a stroke; stroke risk declined from 2% in the first 500 patients to 0.8% in the second 500 patients. Over the course of the experience, myocardial ischemic and cardiopulmonary bypass times (P < .0001), transfusion (P = .003), and intensive care unit and postoperative lengths of stay (P < .05) decreased. CONCLUSIONS: Robotic mitral valve surgery is associated with a high likelihood of valve repair and low operative mortality and morbidity. The combination of algorithm-driven patient selection and increased experience enhanced clinical outcomes and procedural efficiency.
Assuntos
Doenças das Valvas Cardíacas/cirurgia , Implante de Prótese de Valva Cardíaca , Anuloplastia da Valva Mitral , Valva Mitral/cirurgia , Procedimentos Cirúrgicos Robóticos , Idoso , Feminino , Doenças das Valvas Cardíacas/mortalidade , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Implante de Prótese de Valva Cardíaca/estatística & dados numéricos , Humanos , Masculino , Pessoa de Meia-Idade , Valva Mitral/patologia , Anuloplastia da Valva Mitral/efeitos adversos , Anuloplastia da Valva Mitral/métodos , Anuloplastia da Valva Mitral/estatística & dados numéricos , Ohio/epidemiologia , Avaliação de Processos e Resultados em Cuidados de Saúde , Seleção de Pacientes , Estudos Retrospectivos , Procedimentos Cirúrgicos Robóticos/efeitos adversos , Procedimentos Cirúrgicos Robóticos/métodos , Procedimentos Cirúrgicos Robóticos/estatística & dados numéricosRESUMO
BACKGROUND: Bicuspid aortic valves (BAV) are associated with incompletely characterized aortopathy. Our objectives were to identify distinct patterns of aortopathy using machine-learning methods and characterize their association with valve morphology and patient characteristics. METHODS: We analyzed preoperative 3-dimensional computed tomography reconstructions for 656 patients with BAV undergoing ascending aorta surgery between January 2002 and January 2014. Unsupervised partitioning around medoids was used to cluster aortic dimensions. Group differences were identified using polytomous random forest analysis. RESULTS: Three distinct aneurysm phenotypes were identified: root (n = 83; 13%), with predominant dilatation at sinuses of Valsalva; ascending (n = 364; 55%), with supracoronary enlargement rarely extending past the brachiocephalic artery; and arch (n = 209; 32%), with aortic arch dilatation. The arch phenotype had the greatest association with right-noncoronary cusp fusion: 29%, versus 13% for ascending and 15% for root phenotypes (P < .0001). Severe valve regurgitation was most prevalent in root phenotype (57%), followed by ascending (34%) and arch phenotypes (25%; P < .0001). Aortic stenosis was most prevalent in arch phenotype (62%), followed by ascending (50%) and root phenotypes (28%; P < .0001). Patient age increased as the extent of aneurysm became more distal (root, 49 years; ascending, 53 years; arch, 57 years; P < .0001), and root phenotype was associated with greater male predominance compared with ascending and arch phenotypes (94%, 76%, and 70%, respectively; P < .0001). Phenotypes were visually recognizable with 94% accuracy. CONCLUSIONS: Three distinct phenotypes of bicuspid valve-associated aortopathy were identified using machine-learning methodology. Patient characteristics and valvular dysfunction vary by phenotype, suggesting that the location of aortic pathology may be related to the underlying pathophysiology of this disease.
Assuntos
Aorta Torácica/diagnóstico por imagem , Aneurisma Aórtico/diagnóstico por imagem , Valva Aórtica/anormalidades , Aortografia/métodos , Angiografia por Tomografia Computadorizada/métodos , Diagnóstico por Computador/métodos , Doenças das Valvas Cardíacas/diagnóstico por imagem , Aprendizado de Máquina , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Seio Aórtico/diagnóstico por imagem , Adulto , Idoso , Aorta Torácica/fisiopatologia , Aneurisma Aórtico/classificação , Aneurisma Aórtico/etiologia , Aneurisma Aórtico/fisiopatologia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/etiologia , Estenose da Valva Aórtica/fisiopatologia , Doença da Válvula Aórtica Bicúspide , Estudos Transversais , Feminino , Doenças das Valvas Cardíacas/classificação , Doenças das Valvas Cardíacas/complicações , Doenças das Valvas Cardíacas/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Reconhecimento Automatizado de Padrão , Fenótipo , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Seio Aórtico/fisiopatologiaRESUMO
BACKGROUND: The Placement of Aortic Transcatheter Valves 2A (PARTNER-2A) randomized trial compared outcomes of transfemoral transcatheter and surgical aortic valve replacement (SAVR) in intermediate-risk patients with severe aortic stenosis. The purpose of the present study was to perform an in-depth analysis of outcomes after SAVR in the PARTNER-2A trial. METHODS: From January 2012 to January 2014, 937 patients underwent SAVR at 57 centers. Mean age was 82 ± 6.7 years and 55% were men. Less-invasive operations were performed in 140 patients (15%) and concomitant procedures in 198 patients (21%). Major outcomes and echocardiograms were adjudicated by an independent events committee. Follow-up was 94% complete to 2 years. RESULTS: Operative mortality was 4.1% (n = 38, Society of Thoracic Surgeons predicted risk of mortality: 5.2% ± 2.3%), observed to expected ratio (O/E) was 0.8, and in-hospital stroke was 5.4% (n = 51), twice expected. Aortic clamp and bypass times were 75 ± 30 minutes and 104 ± 46 minutes, respectively. Patients having severe prosthesis-patient mismatch (n = 260, 33%) had similar survival to patients without (p > 0.9), as did patients undergoing less-invasive SAVR (p = 0.3). Risk factors for death included cachexia (p = 0.004), tricuspid regurgitation (p = 0.01), coronary artery disease (p = 0.02), preoperative atrial fibrillation (p = 0.001), higher white blood cell count (p < 0.0001), and lower hemoglobin (p = 0.0002). CONCLUSIONS: In this adjudicated prospective study, SAVR in intermediate-risk patients had excellent results at 2 years. However, there were more in-hospital strokes than expected, most likely attributable to mandatory neurologic assessment after the procedure. No pronounced structural valve deterioration was found during 2-year follow-up. Continued long-term surveillance remains important.
Assuntos
Estenose da Valva Aórtica/cirurgia , Complicações Pós-Operatórias/epidemiologia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/mortalidade , Estudos de Coortes , Feminino , Mortalidade Hospitalar , Humanos , Tempo de Internação , Masculino , Fatores de Risco , Taxa de Sobrevida , Resultado do TratamentoRESUMO
Importance: Use of transcatheter aortic valve replacement (TAVR) for severe aortic stenosis is growing rapidly. However, to our knowledge, the durability of these prostheses is incompletely defined. Objective: To determine the midterm hemodynamic performance of balloon-expandable transcatheter heart valves. Design, Setting, and Participants: In this study, we analyzed core laboratory-generated data from echocardiograms of all patients enrolled in the Placement of Aortic Transcatheter Valves (PARTNER) 1 Trial with successful TAVR or surgical AVR (SAVR) obtained preimplantation and at 7 days, 1 and 6 months, and 1, 2, 3, 4, and 5 years postimplantation. Patients from continued access observational studies were included for comparison. Interventions: Successful implantation after randomization to TAVR vs SAVR (PARTNER 1A; TAVR, n = 321; SAVR, n = 313), TAVR vs medical treatment (PARTNER 1B; TAVR, n = 165), and continued access (TAVR, n = 1996). Five-year echocardiogram data were available for 424 patients after TAVR and 49 after SAVR. Main Outcomes and Measures: Death or reintervention for aortic valve structural indications, measured using aortic valve mean gradient, effective orifice area, Doppler velocity index, and evidence of hemodynamic deterioration by reintervention, adverse hemodynamics, or transvalvular regurgitation. Results: Of 2795 included patients, the mean (SD) age was 84.5 (7.1) years, and 1313 (47.0%) were female. Population hemodynamic trends derived from nonlinear mixed-effects models showed small early favorable changes in the first few months post-TAVR, with a decrease of -2.9 mm Hg in aortic valve mean gradient, an increase of 0.028 in Doppler velocity index, and an increase of 0.09 cm2 in effective orifice area. There was relative stability at a median follow-up of 3.1 (maximum, 5) years. Moderate/severe transvalvular regurgitation was noted in 89 patients (3.7%) after TAVR and increased over time. Patients with SAVR showed no significant changes. In TAVR, death/reintervention was associated with lower ejection fraction, stroke volume index, and aortic valve mean gradient up to 3 years, with no association with Doppler velocity index or valve area. Reintervention occurred in 20 patients (0.8%) after TAVR and in 1 (0.3%) after SAVR and became less frequent over time. Reintervention was caused by structural deterioration of transcatheter heart valves in only 5 patients. Severely abnormal hemodynamics on echocardiograms were also infrequent and not associated with excess death or reintervention for either TAVR or SAVR. Conclusions and Relevance: This large, core laboratory-based study of transcatheter heart valves revealed excellent durability of the transcatheter heart valves and SAVR. Abnormal findings in individual patients, suggestive of valve thrombosis or structural deterioration, were rare in this protocol-driven database and require further investigation. Trial Registration: clinicaltrials.gov Identifier: NCT00530894.