Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Urol Case Rep ; 47: 102355, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36866338

RESUMO

Diffuse large B-cell lymphoma (DLBCL) of the genitourinary tract is a rare diagnosis. A 66-year-old male with a history of multiple myeloma and prostate cancer presented with gross hematuria and concern for urinary clot retention. Imaging demonstrated an incidental mass in the left kidney and urinary bladder. Resection of the urinary bladder tumor and biopsy of the kidney revealed Epstein-Barr Virus positive DLBCL. Significant lymphadenopathy was found during staging, and this lymphoma was classified as stage IV. The patient was referred to medical oncology, initiated on chemotherapy, and scheduled for follow up with urology for the renal mass.

2.
Pediatr Pulmonol ; 57(10): 2568-2570, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35856236

RESUMO

Pneumothorax as a sequela of vaping is a relatively recent complication being described in the literature. Smoking has classically been associated with an increased risk of pneumothorax, and emerging evidence is showing that electronic cigarettes (e-cigarettes) likely carry some of the same risks. Since e-cigarettes increased in popularity, especially among the adolescent population, there has been a reported increased incidence of lung injury, including pneumothorax. We present a case of a 15-year-old female with a history of e-cigarette use admitted for recurrent pneumothorax with failure to re-expand requiring surgical intervention.


Assuntos
Sistemas Eletrônicos de Liberação de Nicotina , Pneumotórax , Abandono do Hábito de Fumar , Vaping , Adolescente , Feminino , Humanos , Pneumotórax/diagnóstico por imagem , Pneumotórax/etiologia , Pneumotórax/terapia , Fumar Tabaco , Vaping/efeitos adversos , Vaping/epidemiologia
3.
Biomaterials ; 217: 119289, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-31254935

RESUMO

Intramyocardial hydrogel injection is an innovative and promising treatment for myocardial infarction (MI) and has recently entered clinical trials. By providing mechanical support to the ventricular wall, hydrogel injectate may act to preserve cardiac function and slow the remodeling process that leads to heart failure. However, improved outcomes will likely depend on the use of hydrogels specifically designed for this unique application, and better understanding of the mechanisms affected by the intervention. In this work, we present the first large animal study achieving functional and geometrical improvements in treating MI using a relatively stiff, fully synthetic hydrogel designed for intramyocardial injection. In addition, the renin-angiotensin system coincided with the mechanical effects of hydrogel injection and attenuated left ventricular remodeling, even after significant hydrogel degradation had occurred in vivo. These results may inspire further optimization of hydrogel materials used in intramyocardial hydrogel injection therapy and a better description of physiologic pathways affected by its implementation to facilitate successful clinical translation.


Assuntos
Hidrogéis/administração & dosagem , Hidrogéis/farmacologia , Infarto do Miocárdio/fisiopatologia , Miocárdio/patologia , Remodelação Ventricular/efeitos dos fármacos , Animais , Feminino , Testes de Função Cardíaca , Humanos , Células-Tronco Pluripotentes Induzidas/citologia , Células-Tronco Pluripotentes Induzidas/efeitos dos fármacos , Injeções , Macrófagos/efeitos dos fármacos , Imageamento por Ressonância Magnética , Infarto do Miocárdio/diagnóstico por imagem , Neovascularização Fisiológica/efeitos dos fármacos , Ratos Endogâmicos Lew , Suínos
4.
J Thorac Cardiovasc Surg ; 157(5): 1809-1816, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-30578064

RESUMO

OBJECTIVE: Ideal heart valve solutions aim to provide thrombosis-free durability. A scaffold-based polycarbonate urethane urea tissue-engineered heart valve designed to mimic native valve microstructure and function was used. This study examined the acute in vivo function of a stented tissue-engineered heart valve in a porcine model. METHODS: Trileaflet valves were fabricated by electrospinning polycarbonate urethane urea using double component fiber deposition. The tissue-engineered heart valve was mounted on an AZ31 magnesium alloy biodegradable stent frame. Five 80-kg Yorkshire pigs underwent open tissue-engineered heart valve implantation on cardiopulmonary bypass in the pulmonary position. Tissue-engineered heart valve function was echocardiographically evaluated immediately postimplant and at planned study end points at 1, 4, 8, and 12 hours. Explanted valves underwent biaxial mechanical testing and scanning electron microscopy for ultrastructural analysis and thrombosis detection. RESULTS: All 5 animals underwent successful valve implantation. All were weaned from cardiopulmonary bypass, closed, and recovered until harvest study end point except 1 animal that was found to have congenital tricuspid valve dysplasia and that was euthanized postimplant. All 5 cases revealed postcardiopulmonary bypass normal leaflet function, no regurgitation, and an average peak velocity of 2 m/s, unchanged at end point. All tissue-engineered heart valve leaflets retained microstructural architecture with no platelet activation or thrombosis by scanning electron microscopy. There was microscopic evidence of fibrin deposition on 2 of 5 stent frames, not on the tissue-engineered heart valve. Biaxial stress examination revealed retained postimplant mechanics of tissue-engineered heart valve fibers without functional or ultrastructural degradation. CONCLUSIONS: A biodegradable elastomeric heart valve scaffold for in situ tissue-engineered leaflet replacement is acutely functional and devoid of leaflet microthrombosis.


Assuntos
Implantes Absorvíveis , Ligas/química , Elastômeros/química , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Valva Pulmonar/cirurgia , Engenharia Tecidual/métodos , Alicerces Teciduais , Animais , Implante de Prótese de Valva Cardíaca/efeitos adversos , Teste de Materiais , Modelos Animais , Desenho de Prótese , Falha de Prótese , Valva Pulmonar/diagnóstico por imagem , Valva Pulmonar/ultraestrutura , Estresse Mecânico , Sus scrofa , Trombose/etiologia , Fatores de Tempo
5.
J Thorac Cardiovasc Surg ; 157(1): 176-183, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-30274840

RESUMO

OBJECTIVES: The present study compared physical, mechanical, and biologic characteristics of 4 clinically available surgical sealants for cardiovascular repair. METHODS: BioGlue (Cryolife Inc, Kennesaw, Ga), PreveLeak (Mallinckrodt Pharmaceuticals, St Louis, Mo), Tridyne VS (BD, Franklin Lakes, NJ), and Coseal (Baxter Healthcare Corporation, Westlake Village, Calif) were compared for the following properties: hydrated swelling, cytocompatibility, burst strength, biaxial stretching (elasticity), and in vitro degradation. RESULTS: Sealants showed a wide range of swelling upon hydration. By gravimetric and volumetric measurement, swelling was greatest for Coseal followed by Tridyne VS, BioGlue, and PreveLeak. Tridyne VS was the most cytocompatible based on Alamar Blue assay results, supporting 85% cell survival compared with 36% to 39% survival with the other sealants. All sealants withstood pressure above mean arterial pressure (70-110 mm Hg) and physiologic systolic blood pressure (90-140 mm Hg) in an ex vivo arterial flow burst model; lowest peak pressure at failure was PreveLeak at 235 ± 48 mm Hg, and highest peak pressure at failure was BioGlue at 596 ± 72 mm Hg. Biaxial tensile testing showed no differences in elasticity between ex vivo porcine aorta and carotid arteries and Tridyne VS or Coseal, and BioGlue and PreveLeak were significantly stiffer. In vitro degradation time for Coseal was 6 days and 21 days for Tridyne VS. No degradation was observed in BioGlue or PreveLeak for 30 days. CONCLUSIONS: Although all sealants withstood supraphysiologic arterial pressure, there were differences in characteristics that may be important in clinical outcome. Coseal degradation time was short compared with other sealants, whereas BioGlue and PreveLeak showed a significant compliance mismatch with native porcine carotid artery. Tridyne VS was significantly more cytocompatible than the other 3 sealants.


Assuntos
Materiais Biocompatíveis/uso terapêutico , Adesivos Teciduais/uso terapêutico , Animais , Aorta/cirurgia , Procedimentos Cirúrgicos Cardiovasculares , Artérias Carótidas/cirurgia , Elasticidade , Humanos , Fenômenos Mecânicos , Polietilenoglicóis/uso terapêutico , Pressão , Proteínas/uso terapêutico , Suínos , Resistência à Tração
6.
J Thorac Cardiovasc Surg ; 156(5): 1814-1822.e3, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-30057192

RESUMO

OBJECTIVE: Tissue-engineered vascular grafts containing adipose-derived mesenchymal stem cells offer an alternative to small-diameter vascular grafts currently used in cardiac and lower-extremity revascularization procedures. Adipose-derived, mesenchymal stem cell-infused, tissue-engineered vascular grafts have been shown to promote remodeling and vascular homeostasis in vivo and offer a possible treatment solution for those with cardiovascular disease. Unfortunately, the time needed to cultivate adipose-derived mesenchymal stem cells remains a large hurdle for tissue-engineered vascular grafts as a treatment option. The purpose of this study was to determine if stromal vascular fraction (known to contain progenitor cells) seeded tissue-engineered vascular grafts would remain patent in vivo and remodel, allowing for a "same-day" process for tissue-engineered vascular graft fabrication and implantation. METHODS: Stromal vascular fraction, obtained from adult human adipose tissue, was seeded within 4 hours after acquisition from the patient onto poly(ester urethane)urea bilayered scaffolds using a customized rotational vacuum seeding device. Constructs were then surgically implanted as abdominal aortic interposition grafts in Lewis rats. RESULTS: Findings revealed patency in 5 of 7 implanted scaffolds at 8 weeks, along with neotissue formation and remodeling occurring in patent tissue-engineered vascular grafts. Patency was documented using angiography and gross inspection, and remodeling and vascular components were detected using immunofluorescent chemistry. CONCLUSIONS: A "same-day" cell-seeded, tissue-engineered vascular graft can remain patent after implantation in vivo, with neotissue formation and remodeling occurring by 8 weeks.


Assuntos
Tecido Adiposo/citologia , Aorta Abdominal/cirurgia , Bioprótese , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Transplante de Células-Tronco/instrumentação , Células Estromais/fisiologia , Células Estromais/transplante , Engenharia Tecidual/métodos , Alicerces Teciduais , Adulto , Animais , Aorta Abdominal/metabolismo , Aorta Abdominal/patologia , Aorta Abdominal/fisiopatologia , Biomarcadores/metabolismo , Células Cultivadas , Estudos de Viabilidade , Feminino , Humanos , Pessoa de Meia-Idade , Neointima , Fenótipo , Desenho de Prótese , Ratos Endogâmicos Lew , Células Estromais/metabolismo , Fatores de Tempo , Transplante Heterólogo , Grau de Desobstrução Vascular , Remodelação Vascular , Fluxo de Trabalho
7.
J Biomed Mater Res B Appl Biomater ; 106(2): 659-671, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-28296198

RESUMO

In pediatric cardiovascular surgery, there is a significant need for vascular prostheses that have the potential to grow with the patient following implantation. Current clinical options consist of nonexpanding conduits, requiring repeat surgeries as the patient outgrows the device. To address this issue, PECA Labs has developed a novel ePTFE vascular conduit with the capability of being radially expanded via balloon catheterization. In the described study, a systematic characterization and comparison of two proprietary ePTFE expandable conduits was conducted. Conduit sizes of 8 and 16 mm inner diameters for both conduits were evaluated before and after expansion with a 26 mm balloon. Comprehensive mechanical testing was completed, including quantification of circumferential, and longitudinal tensile strength, suture retention strength, burst strength, water entry pressure, dynamic compliance, and kink radius. Scanning electron microscopy was used to investigate the microstructural properties. Automated extraction of the fiber architectural features for each scanning electron micrograph was achieved with an algorithm for each conduit before and after expansion. Results showed that both conduits were able to expand significantly, to as much as 2.5× their original inner diameter. All mechanical properties were within clinically acceptable values following expansion. Analysis of the microstructure properties of the conduits revealed that the circumferential main angle of orientation, orientation index, and spatial periodicity did not significantly change following expansion, whereas the node area fraction decreased post expansion. Successful proof-of-concept of this novel product represents a critical step toward clinical translation and provides hope for newborns and growing children with congenital heart disease. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 106B: 659-671, 2018.


Assuntos
Prótese Vascular , Procedimentos Cirúrgicos Cardiovasculares , Cardiopatias/congênito , Cardiopatias/cirurgia , Politetrafluoretileno/química , Desenho de Prótese , Doenças Vasculares/cirurgia , Cateterismo Cardíaco , Cateteres Cardíacos , Criança , Humanos , Recém-Nascido , Retenção da Prótese , Resistência à Tração , Doenças Vasculares/congênito
8.
ACS Appl Mater Interfaces ; 6(24): 22796-806, 2014 Dec 24.
Artigo em Inglês | MEDLINE | ID: mdl-25415875

RESUMO

For applications where degradable polymers are likely to have extended blood contact, it is often important for these materials to exhibit high levels of thromboresistance. This can be achieved with surface modification approaches, but such modifications may be transient with degradation. Alternatively, polymer design can be altered such that the bulk polymer is thromboresistant and this is maintained with degradation. Toward this end a series of biodegradable, elastic polyurethanes (PESBUUs) containing different zwitterionic sulfobetaine (SB) content were synthesized from a polycaprolactone-diol (PCL-diol):SB-diol mixture (100:0, 75:25, 50:50, 25:75 and 0:100) reacted with diisocyanatobutane and chain extended with putrescine. The chemical structure, tensile mechanical properties, thermal properties, hydrophilicity, biodegradability, fibrinogen adsorption and thrombogenicity of the resulting polymers was characterized. With increased SB content some weakening in tensile properties occurred in wet conditions and enzymatic degradation also decreased. However, at higher zwitterionic molar ratios (50% and 75%) wet tensile strength exceeded 15 MPa and breaking strain was >500%. Markedly reduced thrombotic deposition was observed both before and after substantial degradation for both of these PESBUUs and they could be processed by electrospinning into a vascular conduit format with appropriate compliance properties. The mechanical and degradation properties as well as the acute in vitro thrombogenicity assessment suggest that these tunable polyurethanes could provide options appropriate for use in blood contacting applications where a degradable, elastomeric component with enduring thromboresistance is desired.


Assuntos
Implantes Absorvíveis , Betaína/análogos & derivados , Materiais Biocompatíveis/síntese química , Materiais Biocompatíveis/farmacologia , Coagulação Sanguínea/efeitos dos fármacos , Poliuretanos/química , Animais , Betaína/química , Coagulação Sanguínea/fisiologia , Bovinos , Fibrinolíticos/síntese química , Fibrinolíticos/farmacologia , Dureza , Teste de Materiais , Resistência à Tração
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA