Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Curr Med Imaging ; 20: e15734056273891, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38204241

RESUMO

BACKGROUND: While cerebral cavernous malformations (CCMs) have been extensively described, few reports have described the imaging appearance of giant CCMs (GCCMs). OBJECTIVE: To describe the imaging characteristics of GCCMs and study the reasons for preoperative misdiagnosis. METHODS: We retrospectively analyzed the data of 12 patients (5 men, 7 women; mean age, 35.23 ± 12.64 years) with histopathologically confirmed GCCMs. Two radiologists analyzed the CT (n = 12) and MRI (n = 10) features: location, number, size, shape, boundary, signal intensity, and enhancement. RESULTS: The sellar region, cerebral hemisphere, skull bone, and ventricle were involved in 5, 4, 2, and 1 patients, respectively. Three tumors were irregularly shaped, while nine were oval. Eleven lesions showed slightly high- and/or high-density on CT; 1 lesion appeared as a low-density cyst. Calcifications were found in 11 lesions. Four tumors showed uniform hypointensity on T1-weighted imaging (T1WI) and hyperintense signals on T2-weighted imaging (T2WI). Six tumors showed mixed low-, equal-, and high-intensity signals on T1WI and T2WI. Noticeable contrast enhancement and gradual strengthening were noted on T1WI. Ten lesions showed hemorrhage and hemosiderin deposition. The GCCMs were wrongly diagnosed as cartilage-derived tumors/ meningioma (3 patients); tumor and hematoma (2 patients each); and pituitary tumor/ meningioma, chondroma, chordoma, ependymoma, and macroadenoma (1 patient each). CONCLUSIONS: GCCMs present as an oval mass with slightly high- and/or high-density calcifications on CT and show hemorrhage and hemosiderin accumulation on MRI. Therefore, slightly high- and/or high-density calcification and hemosiderin accumulation are critical clinical characteristics of GCCMs.


Assuntos
Erros de Diagnóstico , Hemangioma Cavernoso do Sistema Nervoso Central , Imageamento por Ressonância Magnética , Tomografia Computadorizada por Raios X , Humanos , Masculino , Feminino , Adulto , Imageamento por Ressonância Magnética/métodos , Hemangioma Cavernoso do Sistema Nervoso Central/diagnóstico por imagem , Estudos Retrospectivos , Pessoa de Meia-Idade , Tomografia Computadorizada por Raios X/métodos , Adulto Jovem , Neoplasias Encefálicas/diagnóstico por imagem
2.
PLoS One ; 17(9): e0275297, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36155982

RESUMO

OBJECTIVES: Evaluation of the clinical performance of ultra-low-dose computed tomography (CT) images of the shoulder joint on image-based diagnosis and three-dimensional (3D) printing surgical planning. MATERIALS AND METHODS: A total of 93 patients with displaced shoulder fractures were randomly divided into standard-dose, low-dose, and ultra-low-dose groups. Three-dimensional printing models of all patients' shoulder joints were fabricated. The subjective image quality and 3D-printing model were evaluated by two senior orthopedic surgeons who were blinded to any scanning setting. A 3-point scale system was used to quantitatively assess the image quality and 3D printing model, where more than 2 points meant adequate level for clinical application. RESULTS: Compared with the standard dose protocol, ultra-low-dose technique reduced the radiation dose by 99.29% without loss of key image quality of fracture pattern. Regarding the subjective image quality, the assessment scores for groups of standard, low, and ultra-low doses were 3.00, 2.76, 2.00 points on scapula and humerus, and 3.00, 2.73, 2.44 points on clavicle. Scores of the three groups for the assessment of 3D printing models were 3.00, 2.80, 1.34 on scapula and humerus, and 3.00, 2.90, 2.06 on clavicle. In the ultra-low-dose group, 24 out of 33 (72.7%) 3D printing models of scapula and humerus received lower than 2 points of the evaluation score, while nearly 94% of the clavicle models reached the adequate level. CONCLUSION: An ultra-low-dose protocol is adequate for the diagnosis of either displaced or non-displaced fractures of the shoulder joint even though minor flaws of images are present. Three-dimensional printing models of shoulder joints created from ultra-low-dose CT scans can be used for surgical planning at specific bone like the clavicle but perform insufficiently in the overall surgical planning for shoulder injuries due to the significant geometric flaws.


Assuntos
Fraturas do Ombro , Ombro , Clavícula , Humanos , Impressão Tridimensional , Ombro/diagnóstico por imagem , Fraturas do Ombro/cirurgia , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA