Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
J Cardiovasc Electrophysiol ; 34(4): 947-956, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36709469

RESUMO

INTRODUCTION: Thoracic impedance (TI) drops measured by implantable cardioverter-defibrillators (ICDs) have been reported to correlate with ventricular tachycardia/fibrillation (VT/VF). The aim of our study was to assess the temporal association of decreasing TI trends with VT/VF episodes through a longitudinal analysis of daily remote monitoring data from ICDs and cardiac resynchronization therapy defibrillators (CRT-Ds). METHODS AND RESULTS: Retrospective data from 2384 patients were randomized 1:1 into a derivation or validation cohort. The TI decrease rate was defined as the percentage of rolling weeks with a continuously decreasing TI trend. The derivation cohort was used to determine a TI decrease rate threshold for a ≥99% specificity of arrhythmia prediction. The associated risk of VT/VF episodes was estimated in the validation cohort by dividing the available follow-up into 60-day assessment intervals. Analyses were performed separately for 1354 ICD and 1030 CRT-D patients. During a median follow-up of 2.0 years, 727 patients (30.4%) experienced 3298 confirmed VT/VF episodes. In the ICD group, a TI decrease rate of >60% was associated with a higher risk of VT/VF episode in a 60-day assessment interval (stratified hazard ratio, 1.42; 95% confidence interval (CI), 1.05-1.92; p = .023). The TI decrease preceded (40.8%) or followed (59.2%) the VT/VF episodes. In the CRT-D group, no association between TI decrease and VT/VF episodes was observed (p = .84). CONCLUSION: In our longitudinal analysis, TI decrease was associated with VT/VF episodes only in ICD patients. Preventive interventions may be difficult since episodes can occur before or after TI decrease.


Assuntos
Arritmias Cardíacas , Taquicardia Ventricular , Humanos , Arritmias Cardíacas/terapia , Impedância Elétrica , Estudos Retrospectivos , Fibrilação Ventricular , Desfibriladores Implantáveis
2.
Int J Clin Pract ; 2022: 2582923, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35936060

RESUMO

Cancer-associated thrombosis (CAT) is the second main cause of cancer death with high related mortality and morbidity, leading to anticancer agent delays and interruptions. The recommended therapy, low-molecular-weight heparin (LMWH), however, is burdensome for patients and costly for society, as treatment should last until cancer is no longer active, even indefinitely. Tinzaparin is a manageable, efficient, safe, and cost-effective option. Compared to the other LMWHs, advantages are single-daily dose and safety in the elderly and those with renal impairment (RI). The purpose of this review is to critically discuss recent data on its efficacy and safety in CAT.


Assuntos
Neoplasias , Insuficiência Renal , Trombose , Heparina de Baixo Peso Molecular/uso terapêutico , Humanos , Neoplasias/complicações , Trombose/tratamento farmacológico , Tinzaparina
3.
Medicine (Baltimore) ; 101(34): e29429, 2022 Aug 26.
Artigo em Inglês | MEDLINE | ID: mdl-36042679

RESUMO

RATIONALE: Venous thromboembolism is a feared frequent complication of cancer with a 2-way relationship. Low molecular weight heparin is the mainstay of treatment. The use of direct oral anticoagulants is supported by established evidence for the treatment of deep vein thrombosis also in active cancer and they are prioritized over low molecular weight heparin for cancer-associated thrombosis according to current guidelines. However, upper limb deep vein thrombosis is poorly studied with scant data on the use of direct oral anticoagulants in noncatheter-related deep vein thrombosis. We report the case of a patient with noncatheter-related deep vein thrombosis and a rare tumor site effectively and safely treated with a direct oral anticoagulant, edoxaban, after lack of efficacy with low molecular weight heparin. PATIENT CONCERNS: A 35-year-old man with primitive mediastinal seminoma presented at our Cardio-Oncology Unit for prechemotherapy assessment. DIAGNOSIS: Persistent brachiocephalic deep vein thrombosis, despite full-dose enoxaparin, was detected at ultrasonography. INTERVENTION: We decided to switch the anticoagulant treatment from enoxaparin to edoxaban. OUTCOME: The 3-month ultrasonography showed almost total regression of the deep vein thrombosis without any adverse effects and a good patient compliance. LESSONS: We conducted a literature review on upper limb deep vein thrombosis, since its management is challenging due to inconsistency of evidence. This report highlights the benefits of direct oral anticoagulants compared to low molecular weight heparins in cancer-associated thrombosis therapy in terms of efficacy, safety and ease of use.


Assuntos
Seminoma , Neoplasias Testiculares , Trombose , Trombose Venosa , Adulto , Anticoagulantes , Veias Braquiocefálicas/diagnóstico por imagem , Enoxaparina/uso terapêutico , Heparina de Baixo Peso Molecular/uso terapêutico , Humanos , Masculino , Piridinas , Neoplasias Testiculares/tratamento farmacológico , Tiazóis , Trombose/tratamento farmacológico , Trombose Venosa/induzido quimicamente , Trombose Venosa/etiologia
4.
G Ital Cardiol (Rome) ; 23(4): 295-298, 2022 Apr.
Artigo em Italiano | MEDLINE | ID: mdl-35343481

RESUMO

We report the case of a 50-year-old female patient with breast cancer who, during preoperative workup, presented repeated wide QRS complex tachycardias, recorded by Holter ECG. She was immediately referred to a hub center for electrophysiological study where she was diagnosed with right ventricular outflow tract ventricular tachycardia and underwent catheter ablation. The chemotherapy with paclitaxel that the patient was receiving combined with psychological stress may have triggered the arrhythmias.


Assuntos
Ablação por Cateter , Taquicardia Ventricular , Arritmias Cardíacas/cirurgia , Eletrocardiografia , Feminino , Humanos , Pessoa de Meia-Idade , Paclitaxel/efeitos adversos , Taquicardia Ventricular/induzido quimicamente , Taquicardia Ventricular/diagnóstico
5.
J Cardiovasc Med (Hagerstown) ; 20(4): 192-200, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-30762662

RESUMO

AIMS: About one-third of patients receiving cardiac resynchronization therapy (CRT) are not responders, due to either patient selection or technical issues. Left ventricular quadripolar passive fixation leads (QPL) and bipolar active fixation (BAF) leads have been designed to ensure a targeted left ventricular stimulation area, minimizing lead dislodgments and phrenic nerve stimulation (PNS). The aim was to compare real-world safety and efficacy of BAF (Attain Stability, Medtronic Plc.) and QPL (Attain Performa, Medtronic Plc.). METHODS: We performed a retrospective analysis examining procedural and follow-up data of 261 BAF and 124 QPL (programmed to single-site left ventricular pacing), included in the ClinicalService project from 16 Italian hospitals. RESULTS: At median follow-up of 12 months, no difference in left ventricular pacing threshold was recorded between BAF and QPL (1.3 ±â€Š0.9 V @0.4 ms vs. 1.3 ±â€Š1.0 V @0.4 ms; P = 0.749). Total left ventricular lead dislodgement rate was 1.43/100 patient-years in BAF vs. 2.9/100 patient-years in QPL (P = 0.583). However, no dislodgements occurred among BAF after hospital discharge. Events requiring repeated surgery or permanently turning CRT off occurred in 0.8% of BAF, as compared with 4.0% of QPL (P = 0.025). There was no difference between groups in the echo CRT responders' rate (70% of BAF and 66% of QPL; P = 0.589) or in the annual rate of heart failure hospitalization (P = 0.513). CONCLUSIONS: BAF resulted in noninferior clinical outcome and CRT responders' rate in comparison to QPL. Moreover, BAF ensured more precise and stable placement in cardiac veins, with comparable electrical performance and less than 1% patients with unsolved PNS.


Assuntos
Dispositivos de Terapia de Ressincronização Cardíaca , Terapia de Ressincronização Cardíaca/métodos , Insuficiência Cardíaca/terapia , Função Ventricular Esquerda , Idoso , Idoso de 80 Anos ou mais , Terapia de Ressincronização Cardíaca/efeitos adversos , Desenho de Equipamento , Feminino , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/fisiopatologia , Humanos , Itália , Masculino , Pessoa de Meia-Idade , Recuperação de Função Fisiológica , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
6.
Europace ; 15(4): 531-40, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23407627

RESUMO

AIMS: The long-term impact of implantable device-related complications on the patient outcome has not been thoroughly evaluated. The aims of this retrospective, bi-centre study were to analyse the rate and nature of device-related complications requiring surgical revision in a large series of patients undergoing device implantation, elective generator replacement and pacing system upgrade and to systematically assess the impact of such complications on patient outcome and healthcare utilization. METHODS AND RESULTS: Data from 2671 consecutive procedures (1511 device implantations, 1034 elective generator replacements, and 126 pacing system upgrades) performed between January 2006 and March 2011 were retrospectively analysed. The outcome measures recorded were complication-related mortality, number of re-operations, need for complex surgical procedures, number of re-hospitalizations, and additional hospital treatment days. Over a median follow-up of 27 months, the overall rate of complications was 2.8% per procedure-year [9.5% in cardiac resynchronisation therapy (CRT) device implantation, 6.1% in pacing system upgrade, 3.5% in implantable cardioverter defibrillator implantation, 1.7% in pacemaker implantation, and 1.7% in generator replacement). The procedure with the highest risk of complications was CRT device implantation (odds ratio: 6.6; P < 0.001); these complications primarily involved coronary sinus lead dislodgement and device infection. Patients with complications had a significantly higher number of device-related hospitalizations (2.3 ± 0.6 vs. 1.0 ± 0.1; P < 0.001) and hospital treatment days (15.7 ± 25.1 vs. 3.6 ± 1.1; P < 0.001) than those without complications. Device infection was the complication with the greatest negative impact on patient outcome. CONCLUSION: Cardiac resynchronisation therapy implantation was the procedure with the highest risk of complications requiring surgical revision. Complications were associated with substantial clinical consequences and a significant increase in the number and length of hospitalizations.


Assuntos
Dispositivos de Terapia de Ressincronização Cardíaca , Terapia de Ressincronização Cardíaca , Desfibriladores Implantáveis , Remoção de Dispositivo , Cardioversão Elétrica/instrumentação , Falha de Equipamento , Falha de Prótese , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Terapia de Ressincronização Cardíaca/efeitos adversos , Terapia de Ressincronização Cardíaca/mortalidade , Dispositivos de Terapia de Ressincronização Cardíaca/efeitos adversos , Distribuição de Qui-Quadrado , Desfibriladores Implantáveis/efeitos adversos , Remoção de Dispositivo/efeitos adversos , Remoção de Dispositivo/mortalidade , Intervalo Livre de Doença , Cardioversão Elétrica/efeitos adversos , Cardioversão Elétrica/mortalidade , Feminino , Hematoma/etiologia , Hematoma/mortalidade , Hematoma/cirurgia , Hospitalização , Humanos , Itália , Estimativa de Kaplan-Meier , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Modelos de Riscos Proporcionais , Infecções Relacionadas à Prótese/etiologia , Infecções Relacionadas à Prótese/mortalidade , Infecções Relacionadas à Prótese/cirurgia , Reoperação , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Infecção da Ferida Cirúrgica/etiologia , Infecção da Ferida Cirúrgica/mortalidade , Infecção da Ferida Cirúrgica/cirurgia , Fatores de Tempo , Resultado do Tratamento , Adulto Jovem
7.
Europace ; 14(7): 1038-43, 2012 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-22247273

RESUMO

AIMS: Closed-loop stimulation (CLS) pacing has shown greater efficacy in preventing the recurrence of vasovagal syncope (VVS) in patients with a cardioinhibitory response to head-up tilt test (HUTT) compared with conventional pacing. Moreover, there is no conclusive evidence to support the superiority of CLS over the conventional algorithms for syncope prevention. This study retrospectively evaluated the effectiveness of CLS pacing compared with dual-chamber pacing with conventional specialized sensing and pacing algorithms for syncope prevention in the prevention of syncope recurrence in patients with refractory VVS and a cardioinhibitory response to HUTT during a long-term follow-up. METHODS AND RESULTS: Forty-one patients (44% male, 53 ± 16 years) with recurrent, refractory VVS (26% with trauma) and a cardioinhibitory response to HUTT who had undergone pacemaker implantation were included in the analysis. Twenty-five patients received a dual-chamber CLS pacemaker (CLS group) and 16 patients received a dual-chamber pacemaker with conventional algorithms for syncope prevention (conventional pacing group): 9 patients with Medtronic rate drop response algorithm and 7 patients with Guidant-Boston Scientific sudden brady response algorithm. During the follow-up (mean 4.4 ± 3.0 years, interquartile range 2.2-7.4 years) one patient (4%) in the CLS group and six (38%) in the conventional pacing group had syncope recurrences (P= 0.016). The Kaplan-Meier actuarial estimate of first recurrence of syncope after 8 years was 4% in the CLS group and 40% in the conventional pacing group (P= 0.010). CONCLUSIONS: The results of this retrospective analysis show that, in order to prevent a recurrence of VVS in patients with a cardioinhibitory response to HUTT, dual-chamber CLS pacing was more effective than dual-chamber pacing with conventional algorithms for syncope prevention in preventing bradycardia-related syncope.


Assuntos
Algoritmos , Estimulação Cardíaca Artificial/métodos , Diagnóstico por Computador/métodos , Eletrocardiografia/métodos , Síncope Vasovagal/diagnóstico , Síncope Vasovagal/prevenção & controle , Terapia Assistida por Computador/métodos , Retroalimentação , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Método Simples-Cego , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA