Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Sci Rep ; 13(1): 18811, 2023 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-37914714

RESUMO

The relationship between Needle Track Bleeding (NTB) and the occurrence of postoperative immediate pneumothorax remains unclear. In our cross-sectional study, we conducted a retrospective collected of data from 674 consecutive patients who underwent CT-guided percutaneous transthoracic lung biopsies between 2019 and 2022. A logistic regression model was employed to explore the association between NTB and postoperative immediate pneumothorax, and restricted cubic spline curves was used to investigate the link and its explicit curve shape. A sensitivity analysis was performed by transforming the continuous NTB into categorical variable and calculated an E-value. A total of 453 participants (47.90% male) were included in our analysis. The postoperative immediate pneumothorax rate was 41.05% (186/453). We found a negative correlation between NTB and postoperative immediate pneumothorax (OR = 0.91, 95%CI 0.88-0.95) after adjusting for confounding factors. This relationship was nonlinear, with a key inflection point at NTB of 8 mm. No significant link was noted for NTB > 8 mm (OR = 0.98, 95%CI 0.95-1.02), while a protective association was observed for NTB ≤ 8 mm (OR = 0.74, 95%CI 0.66-0.81). NTB showed a nonlinear, protective correlation with postoperative immediate pneumothorax. However, when NTB exceeded 8 mm, the protective association was not observed.


Assuntos
Pneumotórax , Humanos , Masculino , Feminino , Pneumotórax/diagnóstico por imagem , Pneumotórax/etiologia , Pneumotórax/epidemiologia , Estudos Transversais , Estudos Retrospectivos , Fatores de Risco , Pulmão/diagnóstico por imagem , Pulmão/patologia , Hemorragia/patologia , Tomografia Computadorizada por Raios X , Biópsia Guiada por Imagem/efeitos adversos
2.
Quant Imaging Med Surg ; 11(7): 3209-3218, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-34249647

RESUMO

BACKGROUND: The iliotibial band (ITB) has a wide patellar insertion that provides lateral restraint to the patella and maintains the patellofemoral joint's stability. There has been limited investigation into the relationship between patellofemoral malalignment and iliotibial band syndrome (ITBS). METHODS: We retrospectively analyzed 47 knees with ITBS by retrieving magnetic resonance imaging (MRI) data collected over an approximately 6-year period from our database. The Insall-Salvati ratio, lateral patellofemoral angle (LPA), lateral patellar tilt (LPT), lateral trochlear length (LTL), angle of the non-weight-bearing facet of the lateral femoral condyle (nwb-LFCA), and the ITB-lateral femoral condyle (IT-LFC) distance were measured on MR images. The knees of 47 age- and gender-matched subjects were enrolled as the normal group. RESULTS: In the ITBS group, over one third (34%, 16/47) of knees had abnormal patellofemoral measurements, including 8 (17%, 8/47) knees with patellar alta, 11 (23.4%, 11/47) knees with an abnormally decreased LPA, and 5 (10.6%, 5/47) knees with an abnormally increased LPT indicating lateral patellar tilt. Moreover, 8 knees had simultaneous combinations of two or three abnormality parameters, and 8 (17%, 8/47) knees presented with superolateral Hoffa's fat pad edema. The Insall-Salvati ratio, LPT, and nwb-LFCA in the ITBS group were significantly higher than those in the normal group (P=0.001, P<0.001, and P<0.001, respectively); the LPA and IT-LFC distances in the ITBS group were significantly lower (P=0.003, P<0.001, respectively) than those in the normal group. There were mild to moderate correlations between the MRI parameters and ITBS (P=0.006, P<0.001, respectively). CONCLUSIONS: This study confirmed that a higher position or lateral tilt of the patella and a steeper morphology of the anterior part of the lateral femoral condyle were associated with the development of ITBS, which is helpful in understanding and further exploring the mechanism of ITBS.

3.
Int J Hyperthermia ; 37(1): 175-181, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32031430

RESUMO

Purpose: To evaluate endopelvic fascial swelling in patients with uterine fibroids after high-intensity focused ultrasound (HIFU) ablation on magnetic resonance imaging (MRI) and investigate the factors that influence endopelvic fascial swelling.Methods: MRI and clinical data from 188 patients with uterine fibroids who were treated with HIFU were analyzed retrospectively. The patients were divided into a fascial swelling group and a non-swelling group, and the degree of swelling was graded. Fascial swelling was set as the dependent variable, and factors such as baseline characteristics and HIFU parameters, were set as the independent variables. The relationship between these variables and fascial swelling was analyzed by univariate and multivariate analyses. Correlations between the factors and the degree of fascial swelling were evaluated by Kruskal-Wallis test.Results: The univariate analysis revealed that the fibroid location, distance from the fibroid to the sacrum, sonication time, treatment time, treatment intensity, therapeutic dose (TD), and energy efficiency (EEF) all affected the endopelvic fascial swelling (p < 0.05). Subsequently, multivariate analysis showed that the distance from the fibroid to the sacrum was significantly correlated with fascial swelling (p < 0.05). Moreover, TD and sonication time were significantly positively correlated with the degree of fascial swelling (p < 0.05). The incidence of sacrococcygeal pain was significantly correlated with fascial swelling (p < 0.05).Conclusion: The distance from the fibroid to the sacrum was a protective factor for fascial swelling. TD and sonication time were significantly positively correlated with the degree of fascial swelling.


Assuntos
Ablação por Ultrassom Focalizado de Alta Intensidade/métodos , Leiomioma/complicações , Leiomioma/diagnóstico por imagem , Leiomioma/cirurgia , Imageamento por Ressonância Magnética/métodos , Adulto , Feminino , Humanos , Pessoa de Meia-Idade , Adulto Jovem
4.
J Magn Reson Imaging ; 48(1): 266-273, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29251798

RESUMO

BACKGROUND: In fetuses with prenatal ventriculomegaly (VM), ventricular volume on MRI has been shown to correlate with poor postnatal outcomes and in utero death. 3D magnetic resonance hydrography (MRH) has been widely used for MR cholangiopancreatography. PURPOSE: To investigate the reliability of 3D MRH for lateral ventricular volume measurement in fetuses with VM and normal lateral ventricles, using manual multisection planimetry (MSP) as a reference standard. STUDY TYPE: Prospective study. POPULATION: Thirty-five fetuses with VM at 24-37 gestational weeks (GA) and 35 fetuses with normal lateral ventricles at 24-38 GA. FIELD STRENGTH/SEQUENCE: 1.5T MRI with 3D MRH and T2 -weighted single-shot fast-spin echo sequence. ASSESSMENT: Left, right, and total lateral ventricle volumes in fetuses were acquired from 3D MRH and manual MSP. All image analysis was performed by a radiologist twice and another radiologist once, blindly. STATISTICAL TESTS: Analysis of linear regression analysis, Pearson's correlation coefficient, Bland-Altman plots, intraclass correlation coefficient (ICC), and independent samples t-test were used for statistical analyses. RESULTS: There were highly significant relationships between all 3D MRH and manual MSP measurements of lateral ventricular volumes (rVM = 0.92-0.98; rN = 0.95-0.98; all P < 0.0001; VM: VM group, N: normal group), although left, right, and total lateral ventricular volumes measured by 3D MRH tended to be slightly larger than MSP (biasVM 0.1 ± 0.95, 0.26 ± 0.63, and 0.3 ± 0.68 mL, respectively; biasN 0.1 ± 0.95, 0.26 ± 0.63, and 0.3 ± 0.68 mL, respectively). Interrater agreement and intrarater repeatability were also excellent for 3D MRH (ICCVM = 0.994-0.99, ICCN = 0.989-0.992; ICCVM = 0.975-0.987, ICCN = 0.958-0.971, respectively). 3D MRH showed significantly reduced measurement time (VM: 3.55 ± 0.42 vs. 11.81 ± 0.13 min; N: 3.08 ± 0.39 vs. 12.12 ± 0.11 min; all P < 0.0001). DATA CONCLUSION: Lateral ventricular volume measurement by 3D MRH was comparable to manual MSP. LEVEL OF EVIDENCE: 1 Technical Efficacy Stage 1 J. Magn. Reson. Imaging 2017.


Assuntos
Colangiopancreatografia por Ressonância Magnética , Imageamento por Ressonância Magnética , Neoplasias da Bexiga Urinária/diagnóstico por imagem , Feminino , Idade Gestacional , Humanos , Hidrocefalia/diagnóstico por imagem , Imageamento Tridimensional , Inflamação , Ventrículos Laterais/diagnóstico por imagem , Modelos Lineares , Variações Dependentes do Observador , Gravidez , Diagnóstico Pré-Natal/métodos , Estudos Prospectivos , Padrões de Referência , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA