Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Eur J Vasc Endovasc Surg ; 52(6): 758-763, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27771318

RESUMO

OBJECTIVE/BACKGROUND: The management of aortic graft infection (AGI) is highly complex and in the absence of a universally accepted case definition and evidence-based guidelines, clinical approaches and outcomes vary widely. The objective was to define precise criteria for diagnosing AGI. METHODS: A process of expert review and consensus, involving formal collaboration between vascular surgeons, infection specialists, and radiologists from several English National Health Service hospital Trusts with large vascular services (Management of Aortic Graft Infection Collaboration [MAGIC]), produced the definition. RESULTS: Diagnostic criteria from three categories were classified as major or minor. It is proposed that AGI should be suspected if a single major criterion or two or more minor criteria from different categories are present. AGI is diagnosed if there is one major plus any criterion (major or minor) from another category. (i) Clinical/surgical major criteria comprise intraoperative identification of pus around a graft and situations where direct communication between the prosthesis and a nonsterile site exists, including fistulae, exposed grafts in open wounds, and deployment of an endovascular stent-graft into an infected field (e.g., mycotic aneurysm); minor criteria are localized AGI features or fever ≥38°C, where AGI is the most likely cause. (ii) Radiological major criteria comprise increasing perigraft gas volume on serial computed tomography (CT) imaging or perigraft gas or fluid (≥7 weeks and ≥3 months, respectively) postimplantation; minor criteria include other CT features or evidence from alternative imaging techniques. (iii) Laboratory major criteria comprise isolation of microorganisms from percutaneous aspirates of perigraft fluid, explanted grafts, and other intraoperative specimens; minor criteria are positive blood cultures or elevated inflammatory indices with no alternative source. CONCLUSION: This AGI definition potentially offers a practical and consistent diagnostic standard, essential for comparing clinical management strategies, trial design, and developing evidence-based guidelines. It requires validation that is planned in a multicenter, clinical service database supported by the Vascular Society of Great Britain & Ireland.


Assuntos
Aorta/cirurgia , Aortografia/métodos , Técnicas Bacteriológicas , Implante de Prótese Vascular/efeitos adversos , Prótese Vascular/efeitos adversos , Angiografia por Tomografia Computadorizada , Procedimentos Endovasculares/efeitos adversos , Infecções Relacionadas à Prótese/diagnóstico , Stents/efeitos adversos , Terminologia como Assunto , Antibacterianos/uso terapêutico , Aorta/diagnóstico por imagem , Aorta/microbiologia , Aortografia/normas , Técnicas Bacteriológicas/normas , Implante de Prótese Vascular/instrumentação , Tomada de Decisão Clínica , Angiografia por Tomografia Computadorizada/normas , Consenso , Remoção de Dispositivo , Procedimentos Endovasculares/instrumentação , Inglaterra , Humanos , Valor Preditivo dos Testes , Infecções Relacionadas à Prótese/diagnóstico por imagem , Infecções Relacionadas à Prótese/microbiologia , Infecções Relacionadas à Prótese/terapia , Medicina Estatal , Fatores de Tempo
2.
Eur J Nucl Med Mol Imaging ; 41(12): 2310-8, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25156330

RESUMO

PURPOSE: Aortic metabolic activity is suggested to correlate with presence and progression of aneurysmal disease, but has been inadequately studied. This study investigates the 2-[(18)F] fluoro-2-deoxy-D-glucose ((18)F-FDG) uptake in a population of infra-renal abdominal aortic aneurysms (AAA), compared to a matched non-aneurysmal control group. METHODS: The Positron Emission Tomography - Computed Tomography (PET/CT) database was searched for infra-renal AAA. Exclusion criteria were prior repair, vasculitis, and saccular/mycotic thoracic or thoraco-abdominal aneurysms. Matching of 159 non-aneurysmal (<3 cm diameter) controls from the same population was assessed. Infra-renal aortic wall FDG uptake was assessed using visual analysis; maximum standardized uptake value (SUVmax) and target to background mediastinal blood pool ratio (TBR) were documented. Predictors of FDG uptake (age, sex, aortic diameter, hypertension, statin use, and diabetes) were assessed using univariate analysis. Follow-up questionnaires were sent to referring clinicians. RESULTS: Aneurysms (n = 151) and controls (n = 159) were matched (p > 0.05) for age, sex, diabetes, hypertension, smoking status, statin use, and indication for PET/CT. Median aneurysm diameter was 5.0 cm (range 3.2-10.4). On visual analysis there was no significant difference in the overall numbers with increased visual uptake 24% (36/151) in the aneurysm group vs. 19% (30/159) in the controls, p = ns. SUVmax was slightly lower in the aneurysm group vs. controls (mean (2 SD) 1.75(0.79) vs. 1.84(0.58), p = 0.02). However there was no difference in TBR between the AAA group and controls (mean (2 SD) 1.03 (0.46) vs. 1.05(0.31), p = 0.36). During a median 18 (interquartile range 8-35) months' follow-up 20 were repaired and four were confirmed ruptured. CONCLUSIONS: The level of metabolic activity as assessed by (18)F-FDG PET/CT in infra-renal AAA does not correlate with aortic size and does not differ between aneurysms and matched controls.


Assuntos
Aneurisma da Aorta Abdominal/diagnóstico por imagem , Fluordesoxiglucose F18 , Tomografia por Emissão de Pósitrons , Compostos Radiofarmacêuticos , Idoso , Estudos de Casos e Controles , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Imagem Multimodal , Tomografia Computadorizada por Raios X
4.
Eur J Vasc Endovasc Surg ; 46(3): 306-13, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23702108

RESUMO

OBJECTIVES: The management of thoracic and abdominal aortic endograft infection is complex and associated with high mortality. Cases are rare: a recent systematic review identified 117 reported cases; the largest reported series comprises 12 infected endografts. METHODS: We report 22 consecutive patients with infected abdominal or thoracic aortic endovascular devices implanted from 1998 to 2012. Management included extension with new devices, aneurysm sac drainage of pus/irrigation with antibiotics, endograft explantation, and axillo-(bi)femoral reconstruction. RESULTS: Twenty-two patients (16 men) were identified. Median age was 71 years (range, 43-88 years). Index devices were infra-renal endovascular repair (n = 13), and thoracic endovascular repair (n = 9) all for aneurysmal or pseudoaneurysmal disease. Seven (32%) had prior aortic surgery. Follow-up was complete in all cases; in survivors follow-up was a median of 29 (range, 12-45) months. The mortality from explantation of ten infra-renal devices was 1/10 (10%) on-table and a further 2/10 (20%) within 30 days. Device retention led to disease progression and death in all patients with infected endografts. Sac drainage/irrigation provided only temporary control of sepsis. Device extension can treat rupture, but additional devices became infected. CONCLUSION: Abdominal endograft explantation is high risk but may be curative. Appropriate selection of patients for infected endograft explantation remains a major challenge.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Torácica/cirurgia , Prótese Vascular , Infecções Relacionadas à Prótese/terapia , Adulto , Idoso , Idoso de 80 Anos ou mais , Antibacterianos/uso terapêutico , Antifúngicos/uso terapêutico , Implante de Prótese Vascular , Remoção de Dispositivo , Progressão da Doença , Drenagem , Procedimentos Endovasculares , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Seleção de Pacientes , Infecções Relacionadas à Prótese/microbiologia , Infecções Relacionadas à Prótese/mortalidade , Estudos Retrospectivos , Taxa de Sobrevida , Irrigação Terapêutica , Resultado do Tratamento
5.
Eur J Vasc Endovasc Surg ; 43(4): 386-91, 2012 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22326695

RESUMO

OBJECTIVES: To assess the durability of endovascular repair (TEVAR) in chronic type B dissection (CD) and identify factors predictive of outcome. DESIGN: Retrospective analysis of a prospective database. MATERIALS: Patients undergoing TEVAR for CD at a tertiary referral centre 2000-2010. METHODS: Analysis of pre-operative characteristics, operative outcome, false lumen thrombosis, aortic diameter and survival. RESULTS: 58 consecutive patients were included (49 elective, 9 urgent, mean age 66 years). Mean aortic diameter was 6.4 cm (Standard deviation SD 1.3 cm). Three patients died perioperatively (5%, 1 urgent, 2 elective). Complications included retrograde type A dissection (n = 3), paraplegia (1), and transient ischaemic attack (1). Estimated survival (Kaplan-Meier) was 89% (1-year) and 64% (3-years). Forty-seven patients had mid-term imaging follow-up at mean 38 months. Reintervention rate was 15% at 1-year and 29% at 3-years. Aortic diameter decreased in 24, was stable in 15 and increased in 8. Mid-term survival was higher in patients with aortic remodelling (reduction of aortic diameter >0.5 cm; 3-year 89%) than without (54%; Log Rank p = 0.005). Remodelling occurred with extensive false lumen thrombosis. CONCLUSION: Satisfactory mid-term outcome after TEVAR for CD remains a challenge. Survival is associated with aortic remodelling, which is related to persistence of flow in the false lumen.


Assuntos
Aneurisma Aórtico/cirurgia , Dissecção Aórtica/cirurgia , Procedimentos Endovasculares , Idoso , Dissecção Aórtica/classificação , Aneurisma Aórtico/classificação , Doença Crônica , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/epidemiologia , Prognóstico , Estudos Retrospectivos , Taxa de Sobrevida , Fatores de Tempo
6.
Eur J Vasc Endovasc Surg ; 38(5): 608-9, 2009 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-19695909

RESUMO

A 61-year-old man presented with an acute type B aortic dissection for which a stent-graft was introduced. He remains complication-free 4 years onwards and has since been diagnosed with Ehlers-Danlos syndrome type IV (EDS IV). His particular mutation is predicted to result in lesser levels of normal collagen and may explain his favourable outcome from endovascular intervention. Understanding the genotype-phenotype correlation may influence the choice of therapy offered to patients with EDS IV.


Assuntos
Aneurisma da Aorta Torácica/cirurgia , Dissecção Aórtica/cirurgia , Implante de Prótese Vascular , Síndrome de Ehlers-Danlos/diagnóstico , Doença Aguda , Dissecção Aórtica/diagnóstico por imagem , Dissecção Aórtica/etiologia , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/etiologia , Aortografia/métodos , Prótese Vascular , Implante de Prótese Vascular/instrumentação , Colágeno Tipo III/genética , Análise Mutacional de DNA , Síndrome de Ehlers-Danlos/complicações , Síndrome de Ehlers-Danlos/genética , Predisposição Genética para Doença , Humanos , Masculino , Pessoa de Meia-Idade , Mutação , Fenótipo , Stents , Fatores de Tempo , Tomografia Computadorizada por Raios X , Resultado do Tratamento
7.
Ann Vasc Surg ; 21(6): 816-8, 2007 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-17697765

RESUMO

Alport's syndrome is a rare genetic disorder of type IV basement membrane collagen synthesis that typically presents with nephropathy, deafness, and ocular abnormalities. To the best of our knowledge, this is the first report in the world's literature of ruptured thoracoabdominal aortic aneurysm in a young patient with Alport's syndrome and a renal transplant. Hypotheses on an association between collagen disease in Alport's syndrome and aortic aneurysms are discussed.


Assuntos
Aneurisma da Aorta Torácica/etiologia , Ruptura Aórtica/etiologia , Transplante de Rim , Nefrite Hereditária/cirurgia , Adulto , Anastomose Cirúrgica , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/cirurgia , Ruptura Aórtica/diagnóstico por imagem , Ruptura Aórtica/cirurgia , Implante de Prótese Vascular , Remoção de Dispositivo , Oclusão de Enxerto Vascular/cirurgia , Humanos , Masculino , Nefrite Hereditária/complicações , Tomografia Computadorizada por Raios X , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA