Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 114
Filtrar
1.
World J Gastrointest Surg ; 16(6): 1933-1938, 2024 Jun 27.
Artigo em Inglês | MEDLINE | ID: mdl-38983322

RESUMO

BACKGROUND: The combination of magnetic compression anastomosis (MCA) and endoscopy has been used to treat biliary stricture after liver transplantation. However, its use for the treatment of complex biliary obstruction after major abdominal trauma has not been reported. This case report describes the successful use of MCA for the treatment of biliary obstruction resulting from major abdominal trauma. CASE SUMMARY: A 23-year-old man underwent major abdominal surgery (repair of liver rupture, right half colon resection, and ileostomy) following a car accident one year ago. The abdominal drainage tube, positioned at the Winslow foramen, was draining approximately 600-800 mL of bile per day. During the two endoscopic retrograde cholangiopancreatography procedures, the guide wire was unable to enter the common bile duct, which prevented placement of a biliary stent. MCA combined with endoscopy was used to successfully achieve magnetic anastomosis of the peritoneal sinus tract and duodenum, and then a choledochoduodenal stent was placed. Finally, the external biliary drainage tube was removed. The patient achieved internal biliary drainage leading to the removal of the external biliary drainage tube, which improved the quality of life. CONCLUSION: Magnetic compression technique can be used for the treatment of complex biliary obstruction with minimal operative trauma.

2.
World J Gastrointest Surg ; 16(6): 1926-1932, 2024 Jun 27.
Artigo em Inglês | MEDLINE | ID: mdl-38983326

RESUMO

BACKGROUND: The treatment of postoperative anastomotic stenosis after excision of rectal cancer is challenging. Endoscopic balloon dilation and radial incision are not effective in all patients. We present a new endoscopy-assisted magnetic compression technique (MCT) for the treatment of rectal anastomotic stenosis. We successfully applied this MCT to a patient who developed an anastomotic stricture after radical resection of rectal cancer. CASE SUMMARY: A 50-year-old man had undergone laparoscopic radical rectal cancer surgery at a local hospital 5 months ago. A colonoscopy performed 2 months ago indicated that the rectal anastomosis was narrow due to which ileostomy closure could not be performed. The patient came to the Magnetic Surgery Clinic of the First Affiliated Hospital of Xi'an Jiaotong University after learning that we had successfully treated patients with colorectal stenosis using MCT. We performed endoscopy-assisted magnetic compression surgery for rectal stenosis. The magnets were removed 16 d later. A follow-up colonoscopy performed after 4 months showed good anastomotic patency, following which, ileostomy closure surgery was performed. CONCLUSION: MCT is a simple, non-invasive technique for the treatment of anastomotic stricture after radical resection of rectal cancer. The technique can be widely used in clinical settings.

3.
J Surg Oncol ; 2024 Jun 18.
Artigo em Inglês | MEDLINE | ID: mdl-38894619

RESUMO

OBJECTIVES: The objective of the current study was to characterize prognostic factors related to long-term recurrence-free survival after curative-intent resection of intrahepatic cholangiocarcinoma (ICC). METHODS: Data on patients who underwent curative-intent resection for ICC between 2000 and 2020 were collected from an international multi-institutional database. Prognostic factors were investigated among patients who recurred within 5 years versus long-term survivors who survived more than 5 years with no recurrence. RESULTS: Among 635 patients who underwent curative-intent resection for ICC, 104 (16.4%) patients were long-term survivors with no recurrence beyond 5 years after surgery. Patients who survived for more than 5 years with no recurrence were more likely to have less aggressive tumor features, as well as have undergone an R0 resection versus patients who recurred within 5 years after resection. On multivariable analysis, tumor size (>5 cm) (HR: 1.535, 95% CI: 1.254-1.879), satellite lesions (HR: 1.253, 95% CI: 1.003-1.564), and lymph node metastasis (HR: 1.733, 95% CI: 1.349-2.227) were independently associated with recurrence within 5 years. Patients who recurred beyond 5 years (n = 23), 2-5 years (n = 60), and within 2 years (n = 471) had an incrementally worse post-recurrence survival (PRS, 28.0 vs. 20.0 vs. 12.0 months, p = 0.032). Among patients with N0 status, tumor size (>5 cm) (HR: 1.612, 95% CI: 1.087-2.390) and perineural invasion (PNI) (HR: 1.562,95% CI: 1.081-2.255) were risk factors associated with recurrence. Among patients with N1 disease, only a minority (5/128, 3.9%) of patients survived with no recurrence to 5 years. CONCLUSION: Roughly 1 in 6 patients survived for more than 5 years with no recurrence following curative-intent resection of ICC. Among N0 patients, tumor recurrence was associated with tumor size and PNI. Only a small subset of N1 patients experienced long-term survival.

4.
iScience ; 27(6): 110029, 2024 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-38883844

RESUMO

Sorafenib, a first-line drug for advanced hepatocellular carcinoma (HCC), unfortunately encounters resistance in most patients, leading to disease progression. Traditional approaches to counteract this resistance, particularly those targeting the RAF-MEK-ERK pathway, often face clinical feasibility limitations. Magnetic hyperthermia (MH), unlike conventional thermal therapies, emerges as a promising alternative. It uniquely combines magnetothermal effects with an increase in reactive oxygen species (ROS). This study found the potential of intracellular MH enhanced the efficacy of sorafenib, increased cellular sensitivity to sorafenib, and reversed sorafenib resistance by inhibiting the RAF-MEK-ERK pathway in an ROS-dependent manner in a sorafenib-resistant HCC cell. Further, in a sorafenib-resistant HCC mouse model, MH significantly sensitized tumors to sorafenib therapy, resulting in inhibited tumor growth and improved survival rates. This presents a promising strategy to overcome sorafenib resistance in HCC, potentially enhancing therapeutic outcomes for patients with this challenging condition.

5.
BMC Med Imaging ; 24(1): 112, 2024 May 16.
Artigo em Inglês | MEDLINE | ID: mdl-38755567

RESUMO

Accurate preoperative differentiation of the chronic rhinosinusitis (CRS) endotype between eosinophilic CRS (eCRS) and non-eosinophilic CRS (non-eCRS) is an important topic in predicting postoperative outcomes and administering personalized treatment. To this end, we have constructed a sinus CT dataset, which comprises CT scan data and pathological biopsy results from 192 patients of chronic rhinosinusitis with nasal polyps (CRSwNP), treated at the Second Affiliated Hospital of Shantou University Medical College between 2020 and 2022. To differentiate CRSwNP endotype on preoperative CT and improve efficiency at the same time, we developed a multi-view fusion model that contains a mini-architecture with each network of 10 layers by modifying the deep residual neural network. The proposed model is trained on a training set and evaluated on a test set. The multi-view deep learning fusion model achieved the area under the receiver-operating characteristics curve (AUC) of 0.991, accuracy of 0.965 and F1-Score of 0.970 in test set. We compared the performance of the mini-architecture with other lightweight networks on the same Sinus CT dataset. The experimental results demonstrate that the developed ResMini architecture contribute to competitive CRSwNP endotype identification modeling in terms of accuracy and parameter number.


Assuntos
Aprendizado Profundo , Pólipos Nasais , Rinite , Sinusite , Tomografia Computadorizada por Raios X , Humanos , Tomografia Computadorizada por Raios X/métodos , Sinusite/diagnóstico por imagem , Rinite/diagnóstico por imagem , Pólipos Nasais/diagnóstico por imagem , Pólipos Nasais/cirurgia , Pólipos Nasais/patologia , Doença Crônica , Redes Neurais de Computação , Feminino , Masculino , Adulto , Pessoa de Meia-Idade , Curva ROC
6.
Int J Surg ; 2024 May 29.
Artigo em Inglês | MEDLINE | ID: mdl-38814355

RESUMO

BACKGROUND: Some cases of laparoscopic-assisted liver transplantation (LA-LT) with utilization of reduced-size grafts has been reported. We here introduced successful utilization of LA-LT with whole liver grafts and magnetic portal vein anastomosis. METHODS: Eight patients with liver cirrhosis were included for LA-LT using donor organs after cardiac death. The surgical procedures included purely laparoscopic explant hepatectomy and whole-liver graft implantation via the midline incision. After explant removal, the whole-liver graft was then placed in situ, and a side-to-side cavo-caval anastomosis with 4-5 cm oval opening was performed. The magnetic rings were everted on the donor and recipient portal vein, respectively, and the instant attachment of the two magnets at the donor and recipient portal vein allowed fast blood reperfusion, followed by continuous suturing on the surface of the magnets. RESULTS: The median operation time was 495 (range 420-630). The median time of explant hepatectomy and IVC anastomosis was 239 (range 150-300) min and 14.5 (range 10-19) min, respectively. Of note, the median anhepatic time was 25 (range 20-35) min. All the patients were discharged home with no major complications after more than six months follow-up. CONCLUSION: LA-LT with full-size graft is feasible and utilization of magnetic anastomosis would further simplify the procedure.

7.
Bioelectrochemistry ; 158: 108726, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38733722

RESUMO

Mucus hypersecretion resulting from excessive proliferation and metaplasia of goblet cells in the airways is the pathological foundation for Chronic obstructive pulmonary disease (COPD). Clinical trials have confirmed the clinical efficacy of pulsed electric field ablation (PFA) for COPD, but its underlying mechanisms is poorly understood. Cellular and animal models of COPD (rich in goblet cells) were established in this study to detect goblet cells' sensitivity to PFA. Schwan's equation was adopted to calculate the cells' transmembrane potential and the electroporation areas in the cell membrane. We found that goblet cells are more sensitive to low-intensity PFA (250 V/cm-500 V/cm) than BEAS-2B cells. It is attributed to the larger size of goblet cells, which allows a stronger transmembrane potential formation under the same electric field strength. Additionally, the transmembrane potential of larger-sized cells can reach the cell membrane electroporation threshold in more areas. Trypan blue staining confirmed that the cells underwent IRE rate was higher in goblet cells than in BEAS-2B cells. Animal experiments also confirmed that the airway epithelium of COPD is more sensitive to PFA. We conclude that lower-intensity PFA can selectively kill goblet cells in the COPD airway epithelium, ultimately achieving the therapeutic effect of treating COPD.


Assuntos
Eletroporação , Células Caliciformes , Doença Pulmonar Obstrutiva Crônica , Células Caliciformes/patologia , Doença Pulmonar Obstrutiva Crônica/patologia , Doença Pulmonar Obstrutiva Crônica/metabolismo , Doença Pulmonar Obstrutiva Crônica/terapia , Animais , Humanos , Eletroporação/métodos , Linhagem Celular , Potenciais da Membrana , Masculino , Técnicas de Ablação/métodos , Eletricidade , Camundongos
8.
World J Gastroenterol ; 30(16): 2272-2280, 2024 Apr 28.
Artigo em Inglês | MEDLINE | ID: mdl-38690021

RESUMO

BACKGROUND: The magnetic compression technique has been used to establish an animal model of tracheoesophageal fistula (TEF), but the commonly shaped magnets present limitations of poor homogeneity of TEF and poor model control. We designed a T-shaped magnet system to overcome these problems and verified its effectiveness via animal experiments. AIM: To investigate the effectiveness of a T-shaped magnet system for establishing a TEF model in beagle dogs. METHODS: Twelve beagles were randomly assigned to groups in which magnets of the T-shaped scheme (study group, n = 6) or normal magnets (control group, n = 6) were implanted into the trachea and esophagus separately under gastroscopy. Operation time, operation success rate, and accidental injury were recorded. After operation, the presence and timing of cough and the time of magnet shedding were observed. Dogs in the control group were euthanized after X-ray and gastroscopy to confirm establishment of TEFs after coughing, and gross specimens of TEFs were obtained. Dogs in the study group were euthanized after X-ray and gastroscopy 2 wk after surgery, and gross specimens were obtained. Fistula size was measured in all animals, and then harvested fistula specimens were examined by hematoxylin and eosin (HE) and Masson trichrome staining. RESULTS: The operation success rate was 100% for both groups. Operation time did not differ between the study group (5.25 min ± 1.29 min) and the control group (4.75 min ± 1.70 min; P = 0.331). No bleeding, perforation, or unplanned magnet attraction occurred in any animal during the operation. In the early postoperative period, all dogs ate freely and were generally in good condition. Dogs in the control group had severe cough after drinking water at 6-9 d after surgery. X-ray indicated that the magnets had entered the stomach, and gastroscopy showed TEF formation. Gross specimens of TEFs from the control group showed the formation of fistulas with a diameter of 4.94 mm ± 1.29 mm (range, 3.52-6.56 mm). HE and Masson trichrome staining showed scar tissue formation and hierarchical structural disorder at the fistulas. Dogs in the study group did not exhibit obvious coughing after surgery. X-ray examination 2 wk after surgery indicated fixed magnet positioning, and gastroscopy showed no change in magnet positioning. The magnets were removed using a snare under endoscopy, and TEF was observed. Gross specimens showed well-formed fistulas with a diameter of 6.11 mm ± 0.16 mm (range, 5.92-6.36 mm), which exceeded that in the control group (P < 0.001). Scar formation was observed on the internal surface of fistulas by HE and Masson trichrome staining, and the structure was more regular than that in the control group. CONCLUSION: Use of the modified T-shaped magnet scheme is safe and feasible for establishing TEF and can achieve a more stable and uniform fistula size compared with ordinary magnets. Most importantly, this model offers better controllability, which improves the flexibility of follow-up studies.


Assuntos
Modelos Animais de Doenças , Imãs , Traqueia , Fístula Traqueoesofágica , Animais , Cães , Fístula Traqueoesofágica/cirurgia , Fístula Traqueoesofágica/patologia , Fístula Traqueoesofágica/etiologia , Traqueia/cirurgia , Traqueia/patologia , Esôfago/cirurgia , Esôfago/patologia , Esôfago/diagnóstico por imagem , Gastroscopia/instrumentação , Gastroscopia/métodos , Duração da Cirurgia , Masculino , Magnetismo/instrumentação , Desenho de Equipamento , Humanos
9.
Sci Rep ; 14(1): 12462, 2024 05 30.
Artigo em Inglês | MEDLINE | ID: mdl-38816430

RESUMO

Various surgical methods have so far been developed for treating rectovaginal fistula (RVF), each with its own advantages and disadvantages. The lack of standardized animal models of RVF is a major reason for the failure to establish a unified and effective surgical method for the treatment of RVF. This study aimed to explore the feasibility of an RVF animal model by magnetic compression and compare it with the traditional modeling method. Thirty-two female Japanese white rabbits were randomly divided into four groups: A, B, C, and D, based on how the rectovaginal septum was treated. The operation time, intraoperative blood loss, and model success rate of each group were determined. The experimental animals were euthanized 2 weeks after the operation. Their rectovaginal septum specimens were obtained. RVF was observed by the naked eye. The fistula size was measured. Histological changes of fistula were observed by hematoxylin and eosin and Masson staining. All rabbits completed the RVF model and survived 2 weeks after the operation. Groups A and B had no bleeding, while groups C and D had < 0.5 mL of bleeding. The magnet detached in 4-6 days in group A, while it remained in place for 2 weeks after surgery in group B. Only one group D rabbit had a plastic hose for 2 weeks after surgery. The RVFs of groups A and C healed by themselves. In group B, the fistula was well formed. In group D, fistula healing was observed in three animals and the diameter of the fistulas was only 2.82-4.64 mm in the other four animals. Groups B and D had a scar on the inner surface of fistulas. Our study shows that the magnetic compression technique based on the T-shaped magnet is a highly useful method to establishing a continuous and stable RVF model in rabbits.


Assuntos
Modelos Animais de Doenças , Fístula Retovaginal , Animais , Coelhos , Feminino , Fístula Retovaginal/cirurgia , Fístula Retovaginal/patologia
10.
Sci Rep ; 14(1): 10602, 2024 05 08.
Artigo em Inglês | MEDLINE | ID: mdl-38719935

RESUMO

Although the application of magnetic compression anastomosis is becoming increasingly widespread, the magnets used in earlier studies were mostly in the shape of a whole ring. Hence, a deformable self-assembled magnetic anastomosis ring (DSAMAR) was designed in this study for gastrointestinal anastomosis. Furthermore, its feasibility was studied using a beagle model. The designed DSAMAR comprised 10 trapezoidal magnetic units. Twelve beagles were used as animal models, and DSAMARs were inserted into the stomach and colon through the mouth and anus, respectively, via endoscopy to achieve gastrocolic magnamosis. Surgical time, number of failed deformations, survival rate of the animals, and the time of magnet discharge were documented. A month later, specimens of the anastomosis were obtained and observed with the naked eye as well as microscopically. In the gastrocolic anastomosis of the 12 beagles, the procedure took 65-120 min. Although a deformation failure occurred during the operation in one of the beagles, it was successful after repositioning. The anastomosis was formed after the magnet fell off 12-18 days after the operation. Naked eye and microscopic observations revealed that the anastomotic specimens obtained 1 month later were well-formed, smooth, and flat. DSAMAR is thus feasible for gastrointestinal anastomosis under full endoscopy via the natural orifice.


Assuntos
Anastomose Cirúrgica , Estudos de Viabilidade , Animais , Cães , Anastomose Cirúrgica/métodos , Estômago/cirurgia , Imãs , Magnetismo , Cirurgia Endoscópica por Orifício Natural/métodos , Cirurgia Endoscópica por Orifício Natural/instrumentação , Colo/cirurgia , Masculino
11.
World J Gastrointest Surg ; 16(5): 1336-1343, 2024 May 27.
Artigo em Inglês | MEDLINE | ID: mdl-38817276

RESUMO

BACKGROUND: Magnetic anchor technique (MAT) has been applied in laparoscopic cholecystectomy and laparoscopic appendectomy, but has not been reported in laparoscopic partial hepatectomy. AIM: To evaluate the feasibility of the MAT in laparoscopic left lateral segment liver resection. METHODS: Retrospective analysis was conducted on the clinical data of eight patients who underwent laparoscopic left lateral segment liver resection assisted by MAT in our department from July 2020 to November 2021. The Y-Z magnetic anchor devices (Y-Z MADs) was independently designed and developed by the author of this paper, which consists of the anchor magnet and magnetic grasping apparatus. Surgical time, intraoperative blood loss, intraoperative accidents, operator experience, postoperative incision pain score, postoperative complications, and other indicators were evaluated and analyzed. RESULTS: All eight patients underwent a MAT-assisted laparoscopic left lateral segment liver resection, including three patients undertaking conventional 5-port and five patients having a transumbilical single-port operation. The mean operation time was 138 ± 34.32 min (range 95-185 min) and the mean intraoperative blood loss was 123 ± 88.60 mL (range 20-300 mL). No adverse events occurred during the operation. The Y-Z MADs showed good workability and maneuverability in both tissue and organ exposure. In particular, the operators did not experience either a "chopstick" or "sword-fight" effect in the single-port laparoscopic operation. CONCLUSION: The results show that the MAT is safe and feasible for laparoscopic left lateral segment liver resection, especially, exhibits its unique abettance for transumbilical single-port laparoscopic left lateral segment liver resection.

12.
World J Gastrointest Surg ; 16(5): 1443-1448, 2024 May 27.
Artigo em Inglês | MEDLINE | ID: mdl-38817285

RESUMO

BACKGROUND: The treatment of postoperative anastomotic stenosis (AS) after resection of colorectal cancer is challenging. Endoscopic balloon dilation is used to treat stenosis in such cases, but some patients do not show improvement even after multiple balloon dilations. Magnetic compression technique (MCT) has been used for gastrointestinal anastomosis, but its use for the treatment of postoperative AS after colorectal cancer surgery has rarely been reported. CASE SUMMARY: We report a 72-year-old man who underwent radical resection of colorectal cancer and ileostomy one year ago. An ileostomy closure was prepared six months ago, but colonoscopy revealed a narrowing of the rectal anastomosis. Endoscopic balloon dilation was performed three times, but colonoscopy showed no significant improvement in stenosis. The AS was successfully treated using MCT. CONCLUSION: MCT is a minimally invasive method that can be used for the treatment of postoperative AS after colorectal cancer surgery.

13.
World J Gastrointest Surg ; 16(3): 860-870, 2024 Mar 27.
Artigo em Inglês | MEDLINE | ID: mdl-38577092

RESUMO

BACKGROUND: Despite much work having been conducted on magnetic compression anastomosis (MCA) in the digestive tract, there are no reports on the influence of magnetic force on the anastomosis. AIM: To investigate the effect of different magnetic force magnets on the MCA of the digestive tract. METHODS: Two groups of magnets of the same sizes but different magnetic forces were designed and produced. A total of 24 Sprague-Dawley rats were randomly assigned into two groups (powerful magnet group and common magnet group), with 12 rats in each group. Two types of magnets were used to complete the colonic side-to-side anastomosis of the rats. The operation time and magnet discharge time were recorded. The anastomotic specimens were obtained 4 wk after the operation and then the burst pressure and diameter of the anastomosis were measured, and the anastomosis was observed via the naked eye and subjected to histological examination. RESULTS: The magnetic forces of the powerful and common magnet groups at zero distance were 8.26 N and 4.10 N, respectively. The colonic side-to-side anastomosis was completed in all 24 rats, and the operation success rate and postoperative survival rate were 100%. No significant difference was noted in the operation time between the two groups. The magnet discharge time of the powerful magnet group was slightly longer than that of the common magnet group, but the difference was not statistically significant (P = 0.513). Furthermore, there was no statistical difference in the burst pressure (P = 0.266) or diameter of magnetic anastomosis (P = 0.095) between the two groups. The gross specimens of the two groups showed good anastomotic healing, and histological observation indicated good mucosal continuity without differences on healing. CONCLUSION: In the rat colonic side-to-side MCA model, both the powerful magnet with 8.26 N and the common magnet with 4.10 N showed no significant impact on the anastomosis establishment process or its effect.

14.
World J Gastroenterol ; 30(6): 599-606, 2024 Feb 14.
Artigo em Inglês | MEDLINE | ID: mdl-38463020

RESUMO

BACKGROUND: Treatment of postoperative anastomotic stenosis for colorectal cancer is often challenging, especially for patients who do not respond well to endoscopy. In cases where patients have undergone an enterostomy, the stenosis can be easily resolved through magnetic compression. However, common magnetic compression techniques cannot be performed on those without enterostomy. We designed a novel Y-Z deformable magnetic ring (Y-Z DMR) and successfully applied it to a patient with a stenosis rectal anastomosis and without enterostomy after rectal cancer surgery. CASE SUMMARY: We here report the case of a 57-year-old woman who had undergone a laparoscopic radical rectum resection (Dixon) for rectal cancer. However, she started facing difficulty in defecation 6 months after surgery. Her colonoscopy indicated stenosis of the rectal anastomosis. Endoscopic balloon dilation was performed six times on her. However, the stenosis still showed a trend of gradual aggravation. Because the patient did not undergo an enterostomy, the conventional endoscopic magnetic compression technique could not be performed. Hence, we implemented a Y-Z DMR implemented through the anus under single channel. The magnetic ring fell off nine days after the operation and the rectal stenosis was relieved. The patient was followed up for six months and reported good defecation. CONCLUSION: The Y-Z DMR deformable magnetic ring is an excellent treatment strategy for patients with rectal stenosis and without enterostomy.


Assuntos
Laparoscopia , Neoplasias Retais , Humanos , Feminino , Pessoa de Meia-Idade , Constrição Patológica/cirurgia , Constrição Patológica/etiologia , Neoplasias Retais/complicações , Neoplasias Retais/cirurgia , Reto/diagnóstico por imagem , Reto/cirurgia , Laparoscopia/efeitos adversos , Anastomose Cirúrgica/efeitos adversos , Complicações Pós-Operatórias/etiologia , Fenômenos Magnéticos , Estudos Retrospectivos
15.
Nano Lett ; 24(9): 2894-2903, 2024 Mar 06.
Artigo em Inglês | MEDLINE | ID: mdl-38407042

RESUMO

Harnessing the potential of tumor-associated macrophages (TAMs) to engulf tumor cells offers promising avenues for cancer therapy. Targeting phagocytosis checkpoints, particularly the CD47-signal regulatory protein α (SIRPα) axis, is crucial for modulating TAM activity. However, single checkpoint inhibition has shown a limited efficacy. In this study, we demonstrate that ferrimagnetic vortex-domain iron oxide (FVIO) nanoring-mediated magnetic hyperthermia effectively suppresses the expression of CD47 protein on Hepa1-6 tumor cells and SIRPα receptor on macrophages, which disrupts CD47-SIRPα interaction. FVIO-mediated magnetic hyperthermia also induces immunogenic cell death and polarizes TAMs toward M1 phenotype. These changes collectively bolster the phagocytic ability of macrophages to eliminate tumor cells. Furthermore, FVIO-mediated magnetic hyperthermia concurrently escalates cytotoxic T lymphocyte levels and diminishes regulatory T cell levels. Our findings reveal that magnetic hyperthermia offers a novel approach for dual down-regulation of CD47 and SIRPα, reshaping the tumor microenvironment to stimulate immune responses, culminating in significant antitumor activity.


Assuntos
Hipertermia Induzida , Neoplasias , Humanos , Antígeno CD47 , Regulação para Baixo , Imunoterapia , Fagocitose , Fenômenos Magnéticos , Neoplasias/patologia , Microambiente Tumoral
16.
Sci Rep ; 14(1): 1865, 2024 01 22.
Artigo em Inglês | MEDLINE | ID: mdl-38253773

RESUMO

Magnetic compression anastomosis has been reported to have remarkable clinical outcomes. Here, we tested the applicability of a Y-Z deformable magnetic ring (DMR) for non-surgical manipulation of rectal stenosis (RS) in a beagle dog model under a transanal single-access condition. RS was modeled in 8 beagle dogs using partial ligation with silk thread. Under X-ray guidance, the Y-Z DMR was positioned at the proximal and distal ends of the RS, and the magnetic ring was bent into an "O" shape, such that the two rings were magnetically attracted. Operation time, complications during or after operation, and discharge time of the magnetic rings were recorded. The anastomosis bursting pressure was measured two weeks after removing the rings, and its formation was assessed through gross and histological examination. Partial ligation with a silk thread successfully established the canine RS model. After Y-Z DMR installation, the magnetic ring was successfully reconfigured from an "S" to an "O" shape. Strong attraction existed between the rings. The operation time was 9-15 min (average: 11.75 ± 1.98 min). No rectal bleeding or perforation occurred during or after operation. The ring was naturally expelled 7-10 days after surgery. A pressure of > 300 mmHg was recorded at the point of anastomosis rupture. The rectal anastomosis appeared to have healed properly on the surface, which was confirmed histologically, signifying the success of this procedure. A Y-Z DMR facilitated the successful recanalization of transanal single-channel RS without needing surgery in an animal model.


Assuntos
Fenômenos Magnéticos , Seda , Animais , Cães , Constrição Patológica/cirurgia , Fenômenos Físicos , Anastomose Cirúrgica
17.
BMC Gastroenterol ; 24(1): 20, 2024 Jan 05.
Artigo em Inglês | MEDLINE | ID: mdl-38182996

RESUMO

BACKGROUND: To investigate the feasibility of a deformable self-assembled magnetic anastomosis ring (DSAMAR), designed and developed by us, for endoscopic gastrointestinal bypass anastomosis. METHODS: Ten experimental pigs were used as model animals. The DSAMAR comprises 10 trapezoidal magnetic units, arranged in a straight line under the constraint of a guide wire. When the desired anastomosis site is reached under the guidance of an endoscope, the catheter pushes the magnetic unit along the guide wire. The linear DSAMAR can be assembled into a circular DSAMAR. Two DSAMARs were inserted, one at the end of the duodenum and the other into the stomach successively. They attracted each other and compressed the wall of the stomach and duodenum to establish gastrointestinal bypass anastomosis. The experimental pigs were euthanized 4 weeks after the operation, and the gastrointestinal bypass anastomosis specimens were obtained. The anastomosis formation was evaluated by the naked eye and histology. RESULTS: Gastrointestinal bypass anastomosis with DSAMARs was successfully performed. The average operation time under an endoscope was 70.30 ± 19.05 min (range: 43-95 min). The DSAMARs were discharged through the anus 10-17 days after surgery. There were no complications such as gastrointestinal bleeding, perforation, anastomotic fistula, and gastrointestinal obstruction during and after the operation. Gastroscopy and gross specimen of the anastomosis showed a well-formed magnetic anastomosis. Histological observation showed good continuity of the serous membrane and the mucosa of magnetic anastomosis. CONCLUSION: The DSAMAR is a safe and feasible device for fashioning gastrointestinal bypass anastomosis in this animal model.


Assuntos
Gastroscopia , Estômago , Suínos , Animais , Anastomose Cirúrgica , Estômago/cirurgia , Duodeno , Fenômenos Magnéticos
18.
Biomed Pharmacother ; 170: 116077, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38154274

RESUMO

Hepatitis D virus (HDV), which co-infects or superinfects patients with hepatitis B virus, is estimated to affect 74 million people worldwide. Chronic hepatitis D is the most severe form of viral hepatitis and can result in liver cirrhosis, liver failure, and hepatocellular carcinoma (HCC). Currently, there are no efficient HDV-specific drugs. Therefore, there is an urgent need for novel HDV therapies that can achieve a functional cure or even eliminate the viral infection. In the HDV life cycle, agents targeting the entry step of HDV infection preemptively reduce the intrahepatic viral RNA. Human sodium taurocholate co-transporting polypeptide (hNTCP), a transporter of bile acids on the plasma membrane of hepatocytes, is an essential entry receptor of HDV and is a promising molecular target against HDV infection. Here, we investigated the effect of ergosterol peroxide (EP) on HDV infection in vitro and in vivo. EP inhibited HDV infection of hNTCP-expressing dHuS-E/2 hepatocytes by interrupting the early fusion/endocytosis step of HDV entry. Furthermore, molecular modeling suggested that EP hinders LHBsAg binding to hNTCP by blocking access to S267 and V263. In addition, we generated hNTCP-expressing transgenic (Tg) C57BL/6 mice using the Cre/loxP system for in vivo study. EP reduced the liver HDV RNA level of HDV-challenged hNTCP-Cre Tg mice. Intriguingly, EP downregulated the mRNA level of liver IFN-γ. We demonstrate that EP is a bona fide HDV entry inhibitor that acts on hNTCP and has the potential for use in HDV therapies.


Assuntos
Carcinoma Hepatocelular , Hepatite D , Neoplasias Hepáticas , Simportadores , Camundongos , Animais , Humanos , Vírus Delta da Hepatite/genética , Vírus Delta da Hepatite/metabolismo , Carcinoma Hepatocelular/tratamento farmacológico , Carcinoma Hepatocelular/metabolismo , Neoplasias Hepáticas/metabolismo , Camundongos Endogâmicos C57BL , Hepatite D/tratamento farmacológico , Hepatite D/patologia , Vírus da Hepatite B/fisiologia , Hepatócitos , Camundongos Transgênicos , Simportadores/metabolismo
19.
World J Gastrointest Endosc ; 15(11): 658-665, 2023 Nov 16.
Artigo em Inglês | MEDLINE | ID: mdl-38073763

RESUMO

BACKGROUND: Gastric cancer (GC) has high morbidity and mortality. Moreover, because GC has no typical symptoms in the early stages, most cases are already in the advanced stages by the time the symptoms appear, thus resulting in poor prognosis and a low survival rate. Endoscopic submucosal dissection (ESD) can realize the early detection and diagnosis of GC and become the main surgical method for early GC. However, ESD has a steep learning curve and high technical skill requirements for endoscopists, which is not conducive to its widespread implementation and advancement. Therefore, a series of auxiliary techniques have been derived. AIM: To evaluate the safety and efficacy of magnetic anchor technique (MAT)-assisted ESD in early GC. METHODS: This was an ex vivo animal experiment. The experimental models were the isolated stomachs of pigs, which were divided into two groups, namely the study group (n = 6) with MAT-assisted ESD and the control group (n = 6) with traditional ESD. Comparing the total surgical time, incidence of surgical complications, complete mucosal resection rate, specimen size, and the scores of endoscopist's satisfaction with the procedure reflected their feelings about convenience during the surgical procedure between the two groups. The magnetic anchor device for auxiliary ESD in the study group comprised three parts, an anchor magnet (AM), a target magnet (TM), and a soft tissue clip. Under gastroscopic guidance, the soft tissue clip and the TM were delivered to the pre-marked mucosal lesion through the gastroscopic operating hole. The soft tissue clip and the TM were connected by a thin wire through the TM tail structure. The soft tissue clip was released by manipulating the operating handle of the soft tissue clip in a way that the soft tissue clip and the TM were fixed to the lesion mucosa. In vitro, ESD is aided by maneuvering the AM such that the mucosal dissection surface is exposed. RESULTS: The total surgical time was shorter in the study group than in the control group (26.57 ± 0.19 vs 29.97 ± 0.28, P < 0.001), and the scores of endoscopist's satisfaction with the procedure were higher in the study group than in the control group (9.53 ± 0.10 vs 8.00 ± 0.22, P < 0.001). During the operation in the study group, there was no detachment of the soft tissue clip and TM and no mucosal tearing. The magnetic force between the AM and TM provided good mucosal exposure and sufficient tissue tension for ESD. The mucosal lesion was completely peeled off, and the operation was successful. There were no significant differences in the incidence of surgical complications (100% vs 83.3%), complete mucosal resection rate (100% vs 66.7%, P = 0.439), and specimen size (2.44 ± 0.04 cm vs 2.49 ± 0.02, P = 0.328) between the two groups. CONCLUSION: MAT-ESD is safe and effective for early GC. It provides a preliminary basis for subsequent internal animal experiments and clinical research.

20.
Signal Transduct Target Ther ; 8(1): 445, 2023 12 08.
Artigo em Inglês | MEDLINE | ID: mdl-38062078

RESUMO

Ligand-induced receptor dimerization or oligomerization is a widespread mechanism for ensuring communication specificity, safeguarding receptor activation, and facilitating amplification of signal transduction across the cellular membrane. However, cell-surface antigen-induced multimerization (dubbed AIM herein) has not yet been consciously leveraged in chimeric antigen receptor (CAR) engineering for enriching T cell-based therapies. We co-developed ciltacabtagene autoleucel (cilta-cel), whose CAR incorporates two B-cell maturation antigen (BCMA)-targeted nanobodies in tandem, for treating multiple myeloma. Here we elucidated a structural and functional model in which BCMA-induced cilta-cel CAR multimerization amplifies myeloma-targeted T cell-mediated cytotoxicity. Crystallographic analysis of BCMA-nanobody complexes revealed atomic details of antigen-antibody hetero-multimerization whilst analytical ultracentrifugation and small-angle X-ray scattering characterized interdependent BCMA apposition and CAR juxtaposition in solution. BCMA-induced nanobody CAR multimerization enhanced cytotoxicity, alongside elevated immune synapse formation and cytotoxicity-mediating cytokine release, towards myeloma-derived cells. Our results provide a framework for contemplating the AIM approach in designing next-generation CARs.


Assuntos
Mieloma Múltiplo , Receptores de Antígenos Quiméricos , Humanos , Receptores de Antígenos Quiméricos/genética , Mieloma Múltiplo/genética , Mieloma Múltiplo/terapia , Imunoterapia Adotiva/métodos , Antígeno de Maturação de Linfócitos B , Linfócitos T
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA