RESUMO

AIM: The implementation of 3D mapping systems plays an important role in interventional electrophysiology (EP) in recent years. The aim of the present study was to evaluate use of 3D mapping systems regarding fluoroscopy and procedure duration. METHOD: In the "Go for Zero Fluoroscopy" project 25 European centers provided data of consecutive EP procedures. Data on use of 3D mapping systems as well as utilization of contact force catheters and multipolar mapping catheters were associated with fluoroscopy time, dose area product (DAP), and procedure duration. RESULT: A 3D mapping system was used in 966 (54%) cases. Use of 3D mapping for atrioventricular nodal reentry tachycardia (AVNRT) was associated with reduced fluoroscopy time (p < 0.001), DAP (p = 0.04) but increased procedure time (p = 0.029). Moreover, fluoroscopy time (p < 0.001) and DAP (p = 0.005) were significantly lower in the 3D mapping group in ablation of typical atrial flutter. However, the procedure time (p < 0.001) increased. Use of 3D mapping in the ablation of accessory pathway (AP) was associated with reduced fluoroscopy time (p < 0.001) and DAP (p < 0.001) with no significant increase in procedure time (p = 0.066). In the case of atrial fibrillation, a 3D mapping system was used in 485 patients (75.8%). Additional use of a contact force catheter was associated with lower fluoroscopy time (p < 0.001) and DAP (p < 0.001). Use of a multipolar mapping catheter was associated with lower fluoroscopy time (p = 0.002). The implementation of 3D mapping systems in the ablation of ventricular tachycardias resulted in a significant increase in the procedure time (p = 0.001) without significant differences regarding the DAP (p = 0.773) and fluoroscopy time (p = 0.249). CONCLUSION: Use of 3D mapping systems in ablation of supraventricular tachycardias is associated with lower radiation exposure. Nevertheless, the procedure time often increases, except in the case of ablation for AP. Use of contact force catheters and multipolar mapping catheters is associated with yet lower radiation exposure values. Prospective randomized studies are needed to further elucidate potential benefit of these technological tools.


Assuntos
Feixe Acessório Atrioventricular , Fibrilação Atrial , Ablação por Cateter , Humanos , Estudos Prospectivos , Resultado do Tratamento , Fibrilação Atrial/cirurgia , Feixe Acessório Atrioventricular/cirurgia , Eletrofisiologia Cardíaca , Fluoroscopia/métodos , Ablação por Cateter/métodos
2.
Herzschrittmacherther Elektrophysiol ; 33(1): 49-54, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34825951

RESUMO

Non-invasive stereotactic radioablation of ventricular tachycardia (VT) substrate has been proposed as a novel treatment modality for patients not eligible for catheter-based ablation or in whom this approach has failed. Initial clinical results are promising with good short-term efficacy in VT suppression and tolerable side effects. This article reviews the current clinical evidence for cardiac radioablation and gives an overview of important preclinical and translational results. Practical guidance is provided, and a cardiac radioablation planning and treatment workflow based on expert consensus and the authors' institutional experience is set out.


Assuntos
Ablação por Cateter , Taquicardia Ventricular , Arritmias Cardíacas/cirurgia , Coração , Humanos , Imageamento Tridimensional , Taquicardia Ventricular/terapia , Resultado do Tratamento
3.
Herzschrittmacherther Elektrophysiol ; 32(2): 285-287, 2021 Jun.
Artigo em Alemão | MEDLINE | ID: mdl-33944993

RESUMO

Many young women in cardiology are concerned about radiation exposure, and this issue contributes to the low number of female interventional cardiologists. The proportion of women in interventional electrophysiology is particularly low. However, radiation exposure during catheter ablation of arrhythmias can be minimized and even avoided completely using modern 3D mapping systems. The "zero fluoro" approach can improve patients' safety but also motivate more women to become interventional electrophysiologists.


Assuntos
Cardiologia , Ablação por Cateter , Exposição à Radiação , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/cirurgia , Eletrofisiologia Cardíaca , Feminino , Humanos
4.
ESC Heart Fail ; 8(2): 1502-1508, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33538124

RESUMO

AIMS: Patients with adult congenital heart disease (ACHD) carry an increased risk for sudden cardiac death. Implantable cardioverter-defibrillator (ICD) therapy may be challenging in these patients due to anatomical barriers, repeated cardiac surgery, or complicated transvenous access. Thus, the subcutaneous ICD (S-ICD) can be a promising alternative in this patient population. Patients with ACHD show significant electrocardiogram (ECG) abnormalities, which could affect S-ICD sensing because it depends on surface ECG. METHODS AND RESULTS: One hundred patients with ACHD were screened for S-ICD eligibility. Standard ECG-based screening test and automated S-ICD screening test were performed in all patients. Sixty-six patients (66%) were male. Underlying congenital heart disease (CHD) was mainly CHD of great complexity (71%) and moderate complexity (29%), including repaired tetralogy of Fallot (20%), which was the most common entity. Thirty-seven patients (37%) already had a pacemaker (23%) or ICD (14%) implanted. Automated screening test identified 83 patients (83%) eligible for S-ICD implantation in either left parasternal position (78%) or right parasternal position (75%). Absence of sinus rhythm, QRS duration, and a paced QRS complex were associated with S-ICD screening failure in univariate analysis. Receiver operating characteristic curve and multivariate analysis revealed a QRS duration ≥148 ms as the only independent predictor for S-ICD screening failure. CONCLUSIONS: Patients with ACHD show satisfactory eligibility rates (83%) for S-ICD implantation utilizing the automated screening test, including patients with CHD of high complexity. S-ICD therapy should be considered with caution in ACHD patients with a QRS duration ≥148 ms and/or need for ventricular pacing.


Assuntos
Desfibriladores Implantáveis , Cardiopatias Congênitas , Adulto , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/etiologia , Morte Súbita Cardíaca/prevenção & controle , Definição da Elegibilidade , Cardiopatias Congênitas/complicações , Cardiopatias Congênitas/diagnóstico , Cardiopatias Congênitas/terapia , Humanos , Masculino , Seleção de Pacientes