Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Eur J Nutr ; 61(3): 1621-1636, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35013789

RESUMO

PURPOSE: Numerous studies, including our previous work with lemon juice, have reported that low-pH meals reduce the glycemic response to starchy foods. However, the underlying mechanism is not yet understood. Tea, for its polyphenol content, has also been investigated. The main objective of this research was to concurrently study gastric emptying, appetite perceptions and glycemic responses to bread consumed with water, tea, or lemon juice. METHODS: In this randomized, crossover intervention, ten participants consumed equal portions of bread (100 g) with 250 mL of water, water-diluted lemon juice, or black tea at breakfast. Gastric volumes, blood glucose concentrations and appetite perceptions were alternately assessed over 180 min using magnetic resonance imaging, the finger-prick method and visual analogue scales, respectively. RESULTS: Compared to water, lemon juice led to a 1.5 fold increase of the volume of gastric contents, 30 min after the meal (454.0 ± 18.6 vs. 298.4 ± 19.5 mL, [Formula: see text] ± SEM P < 0.00001). Gastric emptying was also 1.5 times faster (P < 0.01). Conversely, lemon juice elicited a lower glycemic response than water (blood glucose concentrations at t = 55 min were 35% lower, P = 0.039). Tea had no effect. Changes in appetite perceptions and gastric volumes correlated well, but with no significant differences between the meals. CONCLUSIONS: Lemon juice lowered the glycemic response and increased both gastric secretions and emptying rate. The results are compatible with the hypothesis that the reduction of the glycemic response is mainly due to the interruption of starch hydrolysis via the acid-inhibition of salivary α-amylase. TRIAL REGISTRATION NUMBER: NCT03265392, August 29, 2017.


Assuntos
Glicemia , Pão , Estudos Cross-Over , Esvaziamento Gástrico/fisiologia , Humanos , Imageamento por Ressonância Magnética , Período Pós-Prandial , Resposta de Saciedade , Chá , Água
2.
Adv Healthc Mater ; 10(16): e2100656, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-34212539

RESUMO

AGuIX are emerging radiosensitizing nanoparticles (NPs) for precision radiotherapy (RT) under clinical evaluation (Phase 2). Despite being accompanied by MRI thanks to the presence of gadolinium (Gd) at its surface, more sensitive and quantifiable imaging technique should further leverage the full potential of this technology. In this study, it is shown that 89 Zr can be labeled on such NPs directly for positron emission tomography (PET) imaging with a simple and scalable method. The stability of such complexes is remarkable in vitro and in vivo. Using a glioblastoma orthotopic rat model, it is shown that injected 89 Zr-AGuIX is detectable inside the tumor for at least 1 week. Interestingly, the particles seem to efficiently infiltrate the tumor even in necrotic areas, which places great hope for the treatment of radioresistant tumor. Lastly, the first PET/MR whole-body imaging is performed in non-human primate (NHP), which further demonstrates the translational potential of these bimodal NP.


Assuntos
Glioblastoma , Nanopartículas , Animais , Meios de Contraste , Glioblastoma/diagnóstico por imagem , Humanos , Macaca , Imageamento por Ressonância Magnética , Imagem Multimodal , Ratos
3.
Magn Reson Med ; 85(2): 926-935, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-32936490

RESUMO

PURPOSE: Because of short signal lifetimes and respiratory motion, 3D lung MRI is still challenging today. Zero-TE (ZTE) pulse sequences offer promising solutions as they overcome the issue of short T2∗ . Nevertheless, as they rely on continuous readout gradients, the trajectories they follow in k-space are not adapted to retrospective gating and inferred motion correction. THEORY AND METHODS: We propose AZTEK (adaptive ZTE k-space trajectories), a set of 3D radial trajectories featuring three tuning parameters, to adapt the acquisition to any moving organ while keeping seamless transitions between consecutive spokes. Standard ZTE and AZTEK trajectories were compared for static and moving phantom acquisitions as well as for human thoracic imaging performed on 3 volunteers (1 healthy and 2 patients with lung cancer). RESULTS: For the static phantom, we observe comparable image qualities with standard and AZTEK trajectories. For the moving phantom, spatially coherent undersampling artifacts observed on gated images with the standard trajectory are alleviated with AZTEK. The same improvement in image quality is obtained in human, so details are more delineated in the lung with the use of the adaptive trajectory. CONCLUSION: The AZTEK technique opens the possibility for 3D dynamic ZTE lung imaging with retrospective gating. It enables us to uniformly sample the k-space for any arbitrary respiratory motion gate, while preserving static image quality, improving dynamic image quality and guaranteeing continuous readout gradient transitions between spokes, which makes it appropriate to ZTE.


Assuntos
Imageamento Tridimensional , Imageamento por Ressonância Magnética , Artefatos , Humanos , Imagens de Fantasmas , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA