Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 59
Filtrar
1.
Surg Today ; 54(1): 73-79, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37490071

RESUMO

PURPOSE: Culture of extracted drains or epicardial pacing wires is an easy and noninvasive method for detecting mediastinitis after open-heart surgery, although studies on its sensitivity and specificity are limited. We, therefore, investigated the usefulness of this approach for diagnosing mediastinitis. METHODS: We retrospectively studied the culture results of drains and epicardial pacing wires extracted from 3308 patients. Prediction models of mediastinitis with and without culture results added to clinical risk factors identified by a logistic regression analysis were compared. RESULTS: The incidence of mediastinitis requiring surgery was 1.89% (n = 64). Staphylococcus was the causative bacterium in 64.0% of cases. The sensitivity, specificity, and positive and negative predictive values of positive culture results were 50.8%, 91.8%, 10.7%, and 99.0%, respectively. Methicillin-resistant Staphylococcus aureus had the highest positive predictive value (61.5%). A multivariate analysis identified preoperative hemodialysis (OR 5.40 [2.54-11.5], p < 0.01), long operative duration (p < 0.01), postoperative hemodialysis (OR 2.25 [1.01-4.98], p < 0.05), and positive culture result (OR 10.2 [5.88-17.7], p < 0.01) as independent risk factors. The addition of culture results to pre- and postoperative hemodialysis and a lengthy operative time improved the prediction of mediastinitis. CONCLUSIONS: A culture survey using extracted drains and epicardial pacing wires may provide useful information for diagnosing mediastinitis.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Mediastinite , Staphylococcus aureus Resistente à Meticilina , Humanos , Estudos Retrospectivos , Mediastinite/diagnóstico , Mediastinite/etiologia , Mediastinite/terapia , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Staphylococcus
2.
Cardiovasc Interv Ther ; 38(4): 414-423, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37278956

RESUMO

The outcome of transcatheter aortic valve replacement (TAVR) for patients with bicuspid aortic valve (BAV) remains unclear, particularly among Asian patients that are known to have different valvular morphology and lower body habitus. This study investigated patient characteristics, procedural and 1-year outcome of TAVR for BAV within national TAVR registry in Japan. The patient-level data were extracted from the J-TVT (Japanese Transcatheter Valvular Therapy) registry between August 2013 and December 2018; overall, there were 423 patients (2.5%) with BAV and 16,802 patients with tricuspid aortic valve (TAV). At baseline, patients with BAV were younger and had less arteriosclerotic comorbidities. There was no statistically significant difference between BAV and TAV groups in conversion to surgery (0.5% vs. 1.1%, p = 0.34) and 30-day mortality (0.5% vs. 1.3%, p = 0.18). Cumulative all-cause survival and survival from major adverse events were analyzed. Cox proportional hazard regression model was used to estimate the hazard ratio. All-cause mortality and major adverse event rate at 1 year were comparable between the two groups. Relative hazard for all-cause mortality for BAV compared to TAV was 1.01 (0.70-1.45; p = 0.96), and for major adverse event was 0.94 (0.69-1.27; p = 0.67). From the Japanese nationwide TAVR registry, procedural and 1-year outcome of TAVR in BAV was as favorable as TAVR in TAV.


Assuntos
Estenose da Valva Aórtica , Doença da Válvula Aórtica Bicúspide , Doenças das Valvas Cardíacas , Estenose da Valva Mitral , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Doença da Válvula Aórtica Bicúspide/complicações , Doença da Válvula Aórtica Bicúspide/cirurgia , Constrição Patológica/etiologia , População do Leste Asiático , Resultado do Tratamento , Doenças das Valvas Cardíacas/cirurgia , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Estenose da Valva Mitral/complicações , Sistema de Registros
3.
J Vasc Surg Cases Innov Tech ; 9(2): 101162, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37168704

RESUMO

Secondary aortoduodenal fistula (sADF) is a critical late complication of abdominal aortic repair, requiring complete excision of the infected prosthesis. However, this is a highly invasive procedure for the elderly. We describe a case of sADF repair in a 76-year-old woman. Through 18F (fluorine-18)-fluorodeoxyglucose (FDG) positron emission tomography/computed tomography mapping, focal high FDG uptake at the sADF site, right medial limb, and ligated left lateral limb of the prosthesis was detected. The duodenal and prosthetic grafts were partially resected. The proximal and distal anastomotic segments, with no FDG uptake, were retained. The abdominal aorta was reconstructed using a bovine pericardium roll and femorofemoral bypass. Thus, FDG positron emission tomography/computed tomography mapping of the infection site could help in such cases.

4.
J Cardiol ; 81(1): 68-75, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-35985870

RESUMO

BACKGROUND: Long-term survival after surgery for severe aortic stenosis (AS) provides important information regarding the choice between surgical (SAVR) and transcatheter (TAVR) aortic valve replacement. This study investigated the long-term survival of AS patients with low or intermediate surgical risk who underwent SAVR or TAVR in our institution versus that of the Japanese general population. METHODS: From 2009 to 2019, 1276 consecutive patients underwent SAVR or TAVR for severe AS. Among them, we retrospectively investigated those with low (n = 383) or intermediate (n = 137) surgical risk treated with SAVR and those with low (n = 86) or intermediate (n = 333) surgical risk treated with TAVR. Their post-intervention survival was compared with that of an age- and gender-matched Japanese general population. RESULTS: The overall 5-year survival rate of SAVR for patients with low surgical risk (mean age, 72 ±â€¯9 years) was not significantly different from that of the general population (90 % vs. 89 %, respectively; p = 0.58), whereas that of patients with intermediate surgical risk (77 ±â€¯6 years) was significantly lower than that of the general population (77 % vs. 84 %, respectively; p = 0.03). After TAVR, the 5-year survival of patients with low (78 ±â€¯8 years) or intermediate (83 ±â€¯5 years) surgical risk was significantly lower than that of the general population (low risk, 64 % vs. 81 %, p < 0.01; intermediate risk, 66 % vs. 71 %, respectively, p = 0.01). CONCLUSIONS: Our study demonstrated that long-term survival after SAVR for AS patients with low surgical risk was as good as that of the age- and gender-matched general population, while the long-term survival after SAVR for intermediate-risk or TAVR for low- or intermediate-risk patients was lower than that of the general population. These findings suggest that SAVR is an appropriate option for AS patients with low surgical risk and good life expectancy, especially in Japan, where the life expectancy is the longest worldwide.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Substituição da Valva Aórtica Transcateter , Humanos , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Substituição da Valva Aórtica Transcateter/efeitos adversos , Estudos Retrospectivos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Resultado do Tratamento , Valva Aórtica/cirurgia , Fatores de Risco
5.
Circ J ; 86(11): 1764-1768, 2022 10 25.
Artigo em Inglês | MEDLINE | ID: mdl-36184556

RESUMO

BACKGROUND: The use of hybrid operating rooms (HOR) for transcatheter aortic valve implantation (TAVI) has increased, so radiation exposure during procedures that use X-ray fluoroscopy is a fundamental problem not only for patients but also for surgeons and interventional cardiologists, increasing the risk of cataracts among operators. We investigated the efficacy of leaded glasses and protective sheets for ocular radiation protection.Methods and Results: Between January 2020 and February 2021 we enrolled 54 TAVI procedures using the transfemoral approach. The subjects were divided into a curtain protection group (Group C, n=20), glass protection group (Group G, n=17), and sheet protection group (Group S, n=17). The cumulative dose (CD) of the operators showed a decreasing trend in Group S compared with the other two groups. The CD normalized by dose area product (CD/DAP) of the operators was significantly reduced in Group S compared with Group C. However, Group G showed no significant difference compared with Group C. Regarding the distribution of CD/DAP, Group S had a significantly lower distribution than that in groups C and G. CONCLUSIONS: Protective sheets provide more stable radiation protection than conventional curtains or leaded glasses.


Assuntos
Estenose da Valva Aórtica , Exposição à Radiação , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Estenose da Valva Aórtica/cirurgia , Doses de Radiação , Fatores de Risco , Exposição à Radiação/efeitos adversos , Exposição à Radiação/prevenção & controle , Fluoroscopia/efeitos adversos , Valva Aórtica/cirurgia , Resultado do Tratamento
6.
Artigo em Inglês | MEDLINE | ID: mdl-36002292

RESUMO

An 82-year-old man who underwent transcatheter aortic valve replacement (TAVR) using a 34-mm Evolut PRO (Medtronic, Minneapolis, MN, USA) for severe aortic stenosis 21 months previously presented with fever. Transesophageal echocardiography showed thickening of the valve leaflets of the transcatheter heart valve and movable structures such as verrucae on the upper edge of the Evolut PRO stent. Contrast-enhanced cardiac computed tomography showed a 72-mm saccular pseudoaneurysm on the dorsal aspect of the ascending aorta at the superior border of the Evolut PRO stent. Because of a suspected infected aortic aneurysm caused by prosthetic valve endocarditis (PVE), we performed aortic valve replacement using 23 mm Avalus (Medtronic, Minneapolis, MN, USA) and ascending aortic replacement using 26 mm Gelweave (Vascutek Terumo Inc, Scotland, UK). The postoperative course was uneventful. This report highlights that patients with PVE after TAVR may develop pseudoaneurysms of the ascending aorta.

7.
Artigo em Inglês | MEDLINE | ID: mdl-36002299

RESUMO

The INSPIRIS RESILIA valve is designed to dilate its valve annulus in transcatheter aortic valve-in-surgical aortic valve (TAV-in-SAV), a catheter therapy for biological valve deterioration. RESILIA tissue has improved anti-calcification properties. An 83-year-old man on hemodialysis undergoing surgical aortic valve replacement (SAVR) with a 25-mm INSPIRIS for severe aortic stenosis 22 months ago presented with general malaise. Transthoracic echocardiography revealed severe bioprosthetic stenosis (peak velocity: 3.5 m/s, mean pressure gradient: 32 mmHg, and effective orifice area: 0.45 cm2) and severely reduced left ventricular function (ejection fraction: 17%). Because redo-SAVR was extremely risky (society of thoracic surgeons [STS] risk score: 31%), the patient underwent transfemoral-TAV-in-SAV using a 26-mm SAPIEN 3️. Pre- and postoperative computed tomography showed that the internal diameter of the INSPIRIS had expanded from 22.2 mm to 24.2 mm. This case demonstrated the dilatable design of INSPIRIS but not the durability of RESILIA tissue.

8.
Artigo em Inglês | MEDLINE | ID: mdl-35732432

RESUMO

A 94-year-old man who underwent transcatheter aortic valve (TAV) replacement 6 years ago was admitted because of exertional dyspnea. Transthoracic echocardiography revealed severe aortic regurgitation owing to TAV dysfunction. The patient was considered to have a high risk of occlusion of the sinus of Valsalva during TAV-in-TAV. Therefore, we performed TAV-in-TAV concomitant with coronary artery bypass grafting (CABG). The postoperative course was uneventful, and computed tomography 9 months later revealed patency of both the grafts. Concomitant CABG could be considered as one of the options in patients with a high risk of coronary occlusion during TAV-in-TAV.

9.
J Am Heart Assoc ; 11(6): e023848, 2022 03 15.
Artigo em Inglês | MEDLINE | ID: mdl-35243902

RESUMO

Background The practice pattern and outcome of medical devices following their regulatory approval may differ by country. The aim of this study is to compare postapproval national clinical registry data on transcatheter aortic valve replacement between the United States and Japan on patient characteristics, periprocedural outcomes, and the variability of outcomes as a part of a partnership program (Harmonization-by-Doing) between the 2 countries. Methods and Results The patient-level data were extracted from the US Society of Thoracic Surgeons /American College of Cardiology Transcatheter Valve Therapy (STS/ACC TVT) and the J-TVT (Japanese Transcatheter Valvular Therapy) registry, respectively, to analyze transcatheter aortic valve replacement outcomes between 2013 and 2019. Data entry for these registries was mandated by the federal regulators, and the majority of variable definitions were harmonized to allow direct data comparison. A total of 244 722 transcatheter aortic valve replacements from 646 institutions in the United States and 26 673 transcatheter aortic valve replacements from 171 institutions in Japan were analyzed. Median volume per site was 65 (interquartile range, 45-97) in the United States and 28 (interquartile range, 19-41) in Japan. Overall, patients in J-TVT were older (United States: mean-age, 80.1±8.7 versus Japan: 84.4±5.2; P<0.001), were more frequently women (45.9% versus 68.1%; P<0.001), and had higher median Society of Thoracic Surgeons Predicted Risk of Mortality (5.27% versus 6.20%; P<0.001) than patients in the United States. Japan had lower unadjusted 30-day mortality (1.3% versus 3.2%; P<0.001) and composite outcomes of death, stroke, and bleeding (17.5 versus 22.5%; P<0.001) but had higher conversion to open surgery (0.94% versus 0.56%; P<0.001). Conclusions This collaborative analysis between the United States and Japan demonstrated the feasibility of international comparison using the national registries coded under mutual variable definitions. Both countries obtained excellent outcomes, although the Japanese had lower 30-day mortality and major morbidity. Harmonization-by-Doing is one of the key steps needed to build global-level learning to improve patient outcomes.


Assuntos
Estenose da Valva Aórtica , Cardiologia , Cirurgiões , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/cirurgia , Feminino , Humanos , Japão/epidemiologia , Sistema de Registros , Fatores de Risco , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento , Estados Unidos/epidemiologia
10.
Gen Thorac Cardiovasc Surg ; 70(6): 584-587, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35201550

RESUMO

Perioperative stroke is one of the most serious complications after transcatheter aortic valve replacement (TAVR), and it should be especially noted in patients with an atheroma in the ascending aorta. Here, we report the first experience of transfemoral (TF)-TAVR with the insertion of a filter device for two patients with severe aortic stenosis who were incidentally detected a grade 4 atheroma in the ascending aorta preoperatively. The patients had a favorable postoperative course without any cerebrovascular events or procedure-related complications.


Assuntos
Estenose da Valva Aórtica , Placa Aterosclerótica , Substituição da Valva Aórtica Transcateter , Aorta/cirurgia , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Humanos , Placa Aterosclerótica/complicações , Placa Aterosclerótica/cirurgia , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
11.
Artigo em Inglês | MEDLINE | ID: mdl-36604286

RESUMO

BACKGROUND: Coronary artery access after repeat transcatheter aortic valve replacement (TAV-in-TAV) is reportedly more difficult because leaflet displacement of the first transcatheter heart valve (THV) impairs coronary cannulation; however, its effects in small patients are unknown. This study aimed to simulate coronary accessibility after TAV-in-TAV in patients of small body size. METHODS: We retrospectively analyzed computed tomography scans after initial THV implantation and classified patients by THV and coronary artery location, valve-to-aorta distance, and valve-to-coronary distance. Risks were compared between the SAPIEN and CoreValve/Evolut series, among THV generations, and between bicuspid and tricuspid aortic valves in the CoreValve/Evolut series. RESULTS: A total of 254 patients (SAPIEN series, n = 164; CoreValve/Evolut series, n = 90) were enrolled. The average body surface area of the patients was 1.44 m2. Patients were classified as "feasible" (26%), "theoretically feasible with low risk" (19.7%), "theoretically feasible with high risk" (8.7%), or "unfeasible" (45.8%). The "unfeasible" rate was significantly higher in the CoreValve/Evolut series than in the SAPIEN series (78.9% vs 26.2%; P < .001). A significantly higher "unfeasible" rate was identified in the current model of SAPIEN (SAPIEN, 8.3%; SAPIENXT, 1.8%; SAPIEN3, 48.2%; P < .001), but not in the CoreValve/Evolut series (CoreValve, 83.3%; Evolut R, 80.0%; Evolut PRO, 71.4%; P = .587). Patients with a bicuspid aortic valve had a lower "unfeasible" rate compared to those with a tricuspid aortic valve (60.0% vs 86.2%; P = .014). CONCLUSIONS: Patients of small body size may have a high probability of "unfeasible" coronary access after TAV-in-TAV, especially when treated with current high-frame devices, suggesting the need for careful strategic planning for initial THV implantation.

12.
Gen Thorac Cardiovasc Surg ; 69(12): 1570-1574, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34580812

RESUMO

An 86-year-old woman with severe aortic stenosis was thought to be at a high risk for surgical aortic valve replacement and inoperability due to old age and porcelain aorta. Furthermore, transcatheter aortic valve replacement (TAVR) was considered difficult due to high risk of coronary obstruction secondary to the aortic root anatomy and poor vascular access associated with marked atherosclerotic lesions on the distal aortic arch with peripheral artery disease. We successfully treated her with TAVR via the brachiocephalic artery in combination with prophylactic off-pump coronary artery bypass grafting.


Assuntos
Estenose da Valva Aórtica , Ponte de Artéria Coronária sem Circulação Extracorpórea , Substituição da Valva Aórtica Transcateter , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Feminino , Humanos , Fatores de Risco , Resultado do Tratamento
13.
Gen Thorac Cardiovasc Surg ; 69(1): 44-50, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-32656706

RESUMO

BACKGROUND: Current guidelines for transcatheter aortic valve replacement (TAVR) recommend that TAVR should be performed in patients with a life expectancy > 1 year. However, it is challenging to estimate the patients' life expectancy because it is related to various factors, including frailty and nutritional status. HYPOTHESIS: A new risk model can estimate the prognosis of patients after TAVR. METHODS: We randomly divided 388 patients with aortic stenosis (AS) undergoing TAVR from October 2009 to August 2016 into two groups (2:1 ratio; training cohort, 259; validation cohort, 129). Using 94 baseline factors in the training cohort, we developed possible scoring models by the Cox proportional hazard regression model with the overall survival as the endpoint. Then, cross-validated 5-year C-statistics were calculated to assess the accuracy of the model. RESULTS: Of 94 baseline factors, 12 factors were finally identified (5-year C-statistics in the training cohort: 0.709)-age, gender, body mass index, left ventricular ejection fraction, % vital capacity, forced expiratory volume 1.0 (s) %, albumin, hemoglobin, creatine, platelet, creatine kinase, and prothrombin time-international normalized ratio. The cross-validated 1-, 3-, and 5-year C-statistics in the validation cohort were 0.792, 0.758, and 0.778, respectively. Furthermore, calibration plots in the validation cohort revealed that 5-year survival is well predicted (r = 0.962). CONCLUSIONS: The new survival prediction model after TAVR could provide appropriate guidance during decision making regarding the TAVR implementation.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Humanos , Prognóstico , Fatores de Risco , Índice de Gravidade de Doença , Volume Sistólico , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento , Função Ventricular Esquerda
14.
Ann Thorac Cardiovasc Surg ; 27(4): 264-266, 2021 Aug 20.
Artigo em Inglês | MEDLINE | ID: mdl-30568074

RESUMO

Transcatheter aortic valve implantation (TAVI) through a peripheral arterial access is often complicated by concomitant arteriopathy. We describe here the first successful case of TAVI through the carotid artery in Japan. The patient was an 83-year-old woman with severe aortic stenosis (AS). Preoperative computed tomography (CT) revealed a shaggy distal aortic arch and left subclavian artery ostium, along with severely calcified bilateral iliofemoral arteries. Trans-apical and direct aortic approaches were abandoned because of frailty. Following the thorough cerebrovascular assessment, the left common carotid artery was selected for arterial access and a CoreValve transcatheter aortic valve was successfully implanted without neurologic complications.


Assuntos
Artérias Carótidas , Substituição da Valva Aórtica Transcateter , Idoso de 80 Anos ou mais , Artérias Carótidas/cirurgia , Feminino , Humanos , Japão , Resultado do Tratamento
15.
J Card Surg ; 36(1): 386-389, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33135298

RESUMO

A 50-year-old man with decompensated aortic stenosis displayed significantly reduced ejection fraction, an ascending aortic aneurysm (55 mm in diameter), and bilateral giant bullae, and was evaluated as having extremely high surgical risk. Therefore, as a bridge to definitive treatment, he simultaneously underwent transcatheter aortic valve replacement (TAVR) and upper left lung lobectomy. His heart function recovered 6 months later and he underwent surgical aortic valve replacement (SAVR) and graft replacement of the ascending aorta. TAVR may serve as a bridge procedure before SAVR for aortic stenosis in younger patients with high surgical risk.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Fatores de Risco , Resultado do Tratamento
16.
J Thorac Cardiovasc Surg ; 158(1): 61-69.e4, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-30685162

RESUMO

OBJECTIVE: This study aimed to assess the predictors of patient-prosthesis mismatch (PPM) after surgical aortic valve replacement (SAVR) or transcatheter aortic valve replacement (TAVR) using preoperative computed tomography. METHODS: We enrolled 323 patients undergoing SAVR (n = 85) or TAVR (n = 238) for aortic stenosis. The end point was any degree of PPM (effective orifice area index <0.85 cm2/m2). We assessed the predictors of PPM after SAVR or TAVR and compared the incidence of PPM between both arms. Furthermore, we compared the hemodynamic performance using the propensity score matching. RESULTS: The occurrence of PPM was significantly higher in the SAVR arm (24.7% vs 7.1%; P < .001). A small sinotubular junction was an independent predictor of PPM in the SAVR arm (odds ratio, 0.79; 95% confidence interval, 0.65-0.96; P = .015), but not a significant predictor in the TAVR arm. In patients with a small sinotubular junction, the prevalence of PPM in the SAVR arm was higher (57.9% vs 2.9%; P < .001). Furthermore, among the propensity score-matched patients, the incidence of PPM in the SAVR arm was higher than that in the TAVR arm (26.3% vs 12.5%; P = .031). CONCLUSIONS: In patients with a small sinotubular junction detected by preoperative computed tomography assessment, the incidence of PPM in patients undergoing SAVR was higher.


Assuntos
Aorta/cirurgia , Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Próteses Valvulares Cardíacas/efeitos adversos , Idoso , Idoso de 80 Anos ou mais , Aorta/diagnóstico por imagem , Aorta/patologia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/patologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/patologia , Estenose da Valva Aórtica/cirurgia , Angiografia por Tomografia Computadorizada , Ecocardiografia Doppler , Feminino , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Masculino , Tomografia Computadorizada Multidetectores , Pontuação de Propensão , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos
17.
Surg Case Rep ; 4(1): 139, 2018 Dec 03.
Artigo em Inglês | MEDLINE | ID: mdl-30511270

RESUMO

BACKGROUND: The age of patients with lung cancer is advancing, and the number of patients with lung cancer who have cardiac diseases is expected to increase. Recently, the rate of transcatheter aortic valve implantation (TAVI) has increased as treatment for aortic stenosis (AS). TAVI is minimally invasive compared with conventional aortic valve replacement. We herein report two patients with lung cancer who underwent lobectomy after TAVI for severe AS. CASE PRESENTATION: Two patients with AS and lung cancer were treated with two-stage surgery of TAVI followed by lobectomy. In patient 1 (77 years of age), conventional aortic valve replacement was considered to be risky because of his history of coronary artery disease and thoracic aortic aneurysm and his relatively high logistic euroSCORE. He underwent TAVI followed by right middle and lower lobectomy. In patient 2 (75 years of age), TAVI was chosen because the patient had poor ADL due to spinal canal stenosis and had taken immunosuppressant agents after a kidney transplantation. He underwent TAVI followed by right lower lobectomy. The postoperative course of the two patients was uneventful. CONCLUSIONS: Two-stage surgery of TAVI and lung resection could be a viable option for patients with both lung cancer and severe AS, for whom conventional AVR by an open-heart operation is not indicated.

18.
Circ J ; 82(8): 1985-1990, 2018 07 25.
Artigo em Inglês | MEDLINE | ID: mdl-29952343

RESUMO

The 82nd Annual Scientific Meeting of the Japanese Circulation Society was held in Osaka, Japan, on March 23-25, 2018, when the cherry blossoms were just opening everywhere around the venue. This was the 5th Annual Scientific Meeting of JCS in which a cardiovascular surgeon served as Congress Chairperson. The main theme of this meeting was "Futurability: Pioneering the Future of Circulatory Medicine". The word, futurability, is a neologism of future ability, because we now have to contemplate what constitutes the essence of cardiovascular medicine, how it should develop as medicine for future generations, and how its ability should be displayed. The meeting was favored by splendid weather and the number of participants was recorded as being higher than 18,700. There were heated and profound discussions about the "futurability" of cardiology, cardiovascular surgery, and heart team medical care as well, in every session. The meeting was successfully completed and we sincerely appreciate the great cooperation and support from all affiliates.


Assuntos
Circulação Sanguínea , Congressos como Assunto , Sociedades Médicas , Cardiologia/tendências , Procedimentos Cirúrgicos Cardiovasculares/tendências , Previsões , Humanos , Japão
19.
Interact Cardiovasc Thorac Surg ; 26(1): 91-97, 2018 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-29049529

RESUMO

OBJECTIVES: Stent graft-induced distal re-dissection (SIDR) is a burdensome complication after thoracic endovascular aortic repair (TEVAR) for Type B aortic dissection. We developed a novel method to prevent SIDR by placing a small-diameter short stent graft [Excluder Aortic Extender (Cuff)] at the distal landing zone (DLZ) and reviewed its effectiveness in this study. METHODS: Ninety patients who underwent TEVAR for Type B aortic dissection using commercially available devices between January 2008 and September 2016 were retrospectively reviewed. Among them, TEVAR with the Cuff technique was performed in 36 (40%) cases, in which a Cuff was placed at the DLZ in the descending aorta prior to the main stent graft deployment to avoid excessive stent graft oversizing at the distal end. The effectiveness of the Cuff technique was assessed by evaluating mid-term clinical results, including the incidence of SIDR. RESULTS: Technical success was achieved in all 90 cases. During a median follow-up time of 40.4 months (range 0.2-90.6 months), 8 SIDRs were documented using multidetector computed tomography images. Freedom from SIDR was significantly lower in the Cuff group (Cuff: 100%/5 years vs non-Cuff: 84.6%/5 years; P = 0.04), whereas no difference was observed between both groups in the oversizing rate at the DLZ (19.9 ± 8.5% vs 17.8 ± 9.9%; P = 0.29). CONCLUSIONS: Placement of a small-diameter short stent graft at the DLZ (Cuff technique) in TEVAR for aortic dissection is an easy procedure that may reduce the incidence of SIDR.


Assuntos
Aneurisma da Aorta Torácica/cirurgia , Dissecção Aórtica/prevenção & controle , Dissecção Aórtica/cirurgia , Implante de Prótese Vascular/efeitos adversos , Prótese Vascular/efeitos adversos , Complicações Pós-Operatórias/prevenção & controle , Stents/efeitos adversos , Adulto , Idoso , Dissecção Aórtica/epidemiologia , Aortografia , Procedimentos Endovasculares/efeitos adversos , Feminino , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/epidemiologia , Recidiva , Estudos Retrospectivos , Fatores de Risco , Tomografia Computadorizada por Raios X , Resultado do Tratamento
20.
Eur J Cardiothorac Surg ; 52(4): 718-724, 2017 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-29156021

RESUMO

OBJECTIVES: Type 1a endoleak is one of the most severe complications after thoracic endovascular aortic repair (TEVAR), because it carries the risk of aortic rupture. The association between bird-beak configuration and Type 1a endoleak remains unclear. The purpose of this study was to analyse the predictors of Type 1a endoleak following Zone 1 and Zone 2 TEVAR, with a particular focus on the effect of bird-beak configuration. METHODS: From April 2008 to July 2015, 105 patients (mean age 68.6 years) who underwent Zone 1 and 2 landing TEVAR were enrolled, with a mean follow-up period of 4.3 years. The patients were categorized into 2 groups, according to the presence (Group B, n = 32) or the absence (Group N, n = 73) of bird-beak configuration on the first postoperative multidetector computed tomography. RESULTS: The Kaplan-Meier event-free rate curve showed that Type 1a endoleak and bird-beak progression occurred less frequently in Group N than in Group B. Five-year freedom from Type 1a endoleak rates were 79.7% and 100% for Groups B and N, respectively (P = 0.007). Multivariable logistic regression analysis showed that dissecting aortic aneurysm (odds ratio 3.72, 95% confidence interval 1.30-11.0; P = 0.014) and shorter radius of inner curvature (odds ratio 1.09, 95% confidence interval 0.85-0.99; P = 0.025) were significant risk factors for bird-beak configuration. Multivariable Cox proportional hazard regression showed that Z-type stent graft (hazard ratio 2.69, 95% confidence interval 1.11-6.51; P = 0.030) was a significant risk factor for bird-beak progression. CONCLUSIONS: Appropriate stent grafts need to be chosen carefully to prevent Type 1a endoleak and bird-beak configuration after landing Zone 1 and 2 TEVAR. Patients with bird-beak configuration on early postoperative multidetector computed tomography require closer follow-up to screen for Type 1a endoleak.


Assuntos
Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/cirurgia , Dissecção Aórtica/cirurgia , Endoleak/etiologia , Procedimentos Endovasculares/efeitos adversos , Stents , Idoso , Dissecção Aórtica/diagnóstico , Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/diagnóstico , Aortografia , Endoleak/diagnóstico , Endoleak/cirurgia , Feminino , Seguimentos , Humanos , Imageamento Tridimensional , Masculino , Tomografia Computadorizada Multidetectores , Desenho de Prótese , Reoperação , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA