Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 26
Filtrar
1.
J Vasc Surg Cases Innov Tech ; 8(1): 35-38, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35097245

RESUMO

Subclavian artery aneurysms are rare peripheral artery aneurysms, and open surgical repair is the reference standard treatment. We have reported the case a patient with a right subclavian artery aneurysm who was not indicated for open surgical repair because of comorbidities. Thus, endovascular treatment using the Gore Excluder Iliac Branch Endoprosthesis (WL Gore and Associates, Flagstaff, Ariz) was performed, leading to complete aneurysmal exclusion without perioperative complications. Although anatomic limitations exist, this technique could be alternative treatment option for right subclavian artery aneurysms.

2.
J Vasc Surg ; 75(3): 803-811.e2, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34742885

RESUMO

OBJECTIVE: To evaluate the early outcomes of retrograde in situ branched stent grafting (RIBS) using the gutter balloon technique for complex aortic arch aneurysms (CAAs). METHODS: The RIBS technique is an in situ needle fenestration procedure during thoracic endovascular aortic repair with the reconstruction of cervical branches. The double RIBS (D-RIBS) for the reconstruction of the left common carotid artery and the brachiocephalic artery using the gutter balloon technique was performed in 30 high-risk patients. We describe the early clinical results of the D-RIBS technique for CAAs. Primary end points were technical success and 30-day mortality. Secondary end points were postoperative complications, rates of endoleaks, overall survival, aneurysm-related death, and reinterventions. RESULTS: The mean age was 77.1 ± 6.6 years, and the mean maximum minor-axis aneurysmal diameter was 65.9 ± 8.9 mm. Twenty-six patients underwent D-RIBS for elective arch aortic aneurysm, and four patients were for reintervention after zone 2 thoracic endovascular aortic repair failure. Stent graft puncture was performed 60 times from the common carotid arteries, and technical success was achieved in all cases (100%). Postoperative complications included cerebral infarction in two patients (6.7%) and recurrent nerve palsy in one patient (3.3%). The 30-day mortality was 0%. During the median follow-up period of 14 months (6-56 months), overall survival at 12 months was 92.3% without any aneurysm-related death. Type 1 b and type 2 endoleaks were observed in one each, and no reintervention was encountered. CONCLUSIONS: Early clinical outcomes of the D-RIBS for high-risk patients with CAAs are acceptable. The gutter balloon method enables safe and reliable fenestration. Further studies and dedicated devices are warranted.


Assuntos
Aneurisma da Aorta Torácica/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Procedimentos Endovasculares/instrumentação , Stents , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/mortalidade , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/mortalidade , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/mortalidade , Feminino , Humanos , Masculino , Complicações Pós-Operatórias/etiologia , Desenho de Prótese , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
3.
J Vasc Surg ; 74(6): 1958-1967.e2, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34182032

RESUMO

OBJECTIVE: We assessed the long-term safety and efficacy of endovascular stent grafting to treat long, complex lesions in the superficial femoral artery (SFA). METHODS: The present prospective, multicenter study at 15 Japanese hospitals assessed heparin-bonded stent grafts used to treat long SFA lesions in patients with symptomatic peripheral arterial disease. The inclusion criteria were Rutherford category 2 to 5 symptoms (grade 5 without active infection), an ankle brachial index of ≤0.9, and SFA lesions ≥10 cm long with ≥50% stenosis. The key efficacy and safety outcomes were primary-assisted patency and adverse events through 24 months, respectively. The secondary outcomes included primary patency, secondary patency, freedom from target lesion revascularization (fTLR), and Vascular Quality of Life questionnaire score. RESULTS: Of the 103 patients (mean age, 74.2 ± 7.0 years; 82.5% male), 100 (97.1%) had intermittent claudication. The average lesion length was 21.8 ± 5.8 cm; 87 lesions (84.5%) were TASC (Trans-Atlantic Inter-Society Consensus Document on Management of Peripheral Arterial Disease) C or D (65.7% chronic total occlusions). Of the 103 patients, 92 and 61 were evaluable through 24 and 60 months, respectively. At 24 months, the Kaplan-Meier-estimated primary-assisted patency, primary patency, and secondary patency rate was 85.7% (95% confidence interval [CI], 76.3%-91.5%), 78.8% (95% CI, 68.8%-85.9%), and 92.0% (95% CI, 82.4%-96.5%), respectively. The mean ankle brachial index was 0.64 ± 0.12 at baseline and 0.94 ± 0.19 at 24 months (P < .0001). At 24 and 60 months, the fTLR was 87.2% (95% CI, 78.9%-92.3%) and 79.1% (95% CI, 67.9%-86.8%), respectively. No device- or procedure-related life- or limb-threatening critical events or acute limb ischemia cases were observed through 5 years. No stent fractures were detected on the annually scheduled follow-up radiographs. The vascular quality of life questionnaire and walking impairment questionnaire scores were significantly increased at 1 through 24 months compared with the baseline scores (P < .0001 for both). One patient had required conversion to open bypass during the 5-year follow-up period. CONCLUSIONS: Stent grafting of long and complex SFA lesions in patients with claudication is safe and effective through long-term follow-up, with 79.1% fTLR and no leg amputation, acute limb ischemia, or stent fractures through 5 years.


Assuntos
Anticoagulantes/administração & dosagem , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Materiais Revestidos Biocompatíveis , Procedimentos Endovasculares/instrumentação , Artéria Femoral/cirurgia , Heparina/administração & dosagem , Doença Arterial Periférica/cirurgia , Stents , Idoso , Idoso de 80 Anos ou mais , Anticoagulantes/efeitos adversos , Implante de Prótese Vascular/efeitos adversos , Procedimentos Endovasculares/efeitos adversos , Feminino , Artéria Femoral/diagnóstico por imagem , Artéria Femoral/fisiopatologia , Heparina/efeitos adversos , Humanos , Japão , Masculino , Pessoa de Meia-Idade , Doença Arterial Periférica/diagnóstico por imagem , Doença Arterial Periférica/fisiopatologia , Estudos Prospectivos , Desenho de Prótese , Qualidade de Vida , Retratamento , Fatores de Tempo , Resultado do Tratamento , Grau de Desobstrução Vascular
4.
Eur J Vasc Endovasc Surg ; 60(1): 57-66, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-31883685

RESUMO

OBJECTIVE: The aim of this study was to investigate the correlation between shaggy aorta and embolic complications during thoracic endovascular aneurysm repair (TEVAR), based on a shaggy aorta scoring system. METHODS: The entire aorta was assessed based on 5 mm slice computed tomography (CT) from the sinotubular junction to the aortic bifurcation using a three dimensional workstation. One shaggy point (shaggy score) was given when the following conditions were met: 1) ulcer like thrombus, 2) maximum thrombus thickness ≥ 5 mm, and 3) mural thrombus occupies more than two thirds of the circumference of the aortic diameter on reconstructed CT of the axial statue. Subsequently, each point was added to obtain the total shaggy score. RESULTS: The outcomes of 301 patients undergoing TEVAR were evaluated. Post-operative embolic complications including stroke, acute renal failure, and distal embolisation, were identified in 21 cases (7.0%). The average shaggy score for the entire cohort was 2.4 ± 5.6 points, whereas it was 7.9 ± 7.1 in those patients with embolic complications (E group) and 2.0 ± 5.3 in those without embolic complications (N group, p = .001). There were no statistical differences in 30 day mortality (p = .70), but overall survival at two years was significantly lower in the E group (E: 58.8%, N: 93.3%, p < .001). Multivariable analysis revealed that the predictors of post-operative embolic complication were past history of cerebrovascular disease (p = .001, OR 5.90, 95% CI 2.14-16.29) and shaggy score (p < .001, OR 1.13, 95% CI 1.06-1.19). The area under the ROC curve was 0.77, and the cut off value of the shaggy score using the Youden index was 3 points (sensitivity: 71.4%, specificity: 81.4%). CONCLUSION: This shaggy score is a useful method to predict post-operative embolic complications following TEVAR. Because the risk of embolic complications was relatively high in patients with a high shaggy score, the indication for TEVAR in such patients should be considered carefully.


Assuntos
Aneurisma da Aorta Torácica/cirurgia , Embolia/etiologia , Procedimentos Endovasculares/efeitos adversos , Idoso , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/patologia , Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/patologia , Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/métodos , Angiografia por Tomografia Computadorizada , Feminino , Humanos , Masculino , Medição de Risco/métodos , Stents/efeitos adversos
5.
Surg Today ; 50(11): 1343-1352, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31776776

RESUMO

Open surgical repair (OSR) for thoracoabdominal aortic aneurysms (TAAAs) is maximally invasive and associated with high rates of operative mortality and perioperative complications including spinal cord ischemia (SCI), despite improvements in surgical techniques and perioperative care. Elderly patients, patients with a history of aortic surgery, and patients with severe comorbidities are often considered ineligible for this surgery and endovascular treatment may be their only treatment option. Total endovascular aneurysm repair (t-EVAR) without debranching surgery does not require thoracotomy and laparotomy and could improve the outcomes of these patients. t-EVAR includes fenestrated EVAR (f-EVAR), multi-branched EVAR (b-EVAR), and physician-modified fenestration endograft (PMFG). Although these techniques have achieved lower mortality rates than OSR, there are concerns about perioperative complications including limb ischemia, SCI, and long-term outcomes such as endograft migration and endoleaks (ELs). This article provides an overview of available endovascular devices for TAAAs and reviews the short and mid-term results of t-EVAR, as well as alternative options.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Torácica/cirurgia , Procedimentos Endovasculares/métodos , Procedimentos Endovasculares/tendências , Aneurisma da Aorta Abdominal/diagnóstico , Aneurisma da Aorta Torácica/diagnóstico por imagem , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/mortalidade , Extremidades/irrigação sanguínea , Humanos , Isquemia , Complicações Pós-Operatórias , Medula Espinal/irrigação sanguínea , Stents , Fatores de Tempo , Tomografia Computadorizada por Raios X , Resultado do Tratamento
6.
Ann Vasc Surg ; 66: 212-219, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-30802578

RESUMO

BACKGROUND: Chimney thoracic endovascular aneurysm repair (TEVAR) has advantages that include no requirements for special devices; however, problems have been identified such as gutter leaks. The aim of this study is to evaluate the short- and mid-term results of TEVAR with chimney technique including the safety, efficacy, and risk factors for occurrence of gutter endoleak in this technique. METHODS: A retrospective single-center study was conducted on 55 consecutive patients who underwent first-time chimney TEVAR for arch aneurysms in the past 7 years. This consisted of 33 cases of single-chimney (SC) TEVAR and 22 cases of double-chimney (DC) TEVAR. The outcomes of these 55 cases of SC-TEVAR and DC-TEVAR were retrospectively examined. Risk factors for endoleaks in chimney TEVAR were also examined. RESULTS: Operative mortalities of 3.0% and 4.5% were observed in SC-TEVAR and DC-TEVAR, respectively. Incidences of stroke were 12.1% in the SC-TEVAR and 4.5% in the DC-TEVAR, resulting in endoleaks in 16 patients (48.5%) in SC-TEVAR and 6 patients (27.3%) in DC-TEVAR. Only 1 of the 77 chimney grafts was occluded, with a patency rate of 98.7%. SC-TEVAR and small distance from the common carotid artery were the risk factors of type I endoleaks. Overall survival rates over a period of 1, 3, and 5 years were 82.3%, 78.0%, and 57.7%, respectively, in the SC-TEVAR group and 95.2%, 89.3%, and 76.5%, respectively, in the DC-TEVAR group. Freedom from aneurysm-related death over 1, 3, and 5 years was 82.3%, 69.0%, and 57.7%, respectively, in the SC-TEVAR group and 95.2%, 89.3%, and 89.3% in the DC-TEVAR group. Freedom from secondary intervention over 1, 3, and 5 years was 80.2%, 64.7%, and 47.2%, respectively, in the SC-TEVAR group and 95.0%, 74.0%, and 74.0%, respectively, in the DC-TEVAR group. CONCLUSIONS: The short- and mid-term results of chimney TEVAR were worse than expectation. Especially, the results of SC-TEVAR were not acceptable because of extremely high incidence of type I endoleak and high incidence of stroke.


Assuntos
Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/cirurgia , Implante de Prótese Vascular , Procedimentos Endovasculares , Idoso , Idoso de 80 Anos ou mais , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/fisiopatologia , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/mortalidade , Aneurisma da Aorta Torácica/fisiopatologia , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Implante de Prótese Vascular/mortalidade , Endoleak/etiologia , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Procedimentos Endovasculares/mortalidade , Feminino , Humanos , Masculino , Intervalo Livre de Progressão , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Acidente Vascular Cerebral/etiologia , Fatores de Tempo
7.
J Cardiovasc Surg (Torino) ; 61(1): 78-83, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30168307

RESUMO

BACKGROUND: Percutaneous endovascular aortic repair (PEVAR) is widespread for the treatment of abdominal aortic aneurysm (AAA). The purpose of this study was to present outcomes of PEVAR using simultaneous angiography via microsheath. METHODS: There were 100 punctures in 50 patients undergoing PEVAR for AAA. All cases used the ProGlide closure device (Abbot Vascular, Santa Clara, CA, USA) for PEVAR, and another puncture with microsheath placed on the common femoral artery for a second insertion point of the ProGlide. Basically, a single ProGlide was used for each puncture in the PEVAR. Hemostasis, stenosis, dissection, and distal embolization were confirmed in angiography via the adjunctive microsheath after removal of the delivery system. Since the PEVAR for AAA requires at least two punctures, this procedure was applied to both sites. Primary outcome was technical success and occurrence rates of access-related complications in PEVAR. Technical success was defined as complete hemostasis without surgical intervention and the need for conversion to general anesthesia. RESULTS: Technical success was achieved in 98% (98/100) of the cases. Access-related complications on perioperative periods were identified in two cases. One case involved a tip of the microsheath being transected by the ProGlide that led to a distal embolization, which is why a cut down was required to retrieve the tip of the sheath. Another case required a cut down due to persistent hemorrhage from the puncture site of the microsheath. Although persistent hemorrhage was identified in five punctures (5.0%) via the adjunctive microsheath angiography, additional manual compression or ProGlide achieved complete hemostasis. Both stenosis and dissection following PEVAR were not identified in any case. CONCLUSIONS: A supporting angiography via microsheath in confirming the absence of hemorrhage, stenosis, dissection, and distal embolization may be worthwhile to selectively use for cases of PEVAR.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Cateterismo Periférico/instrumentação , Angiografia por Tomografia Computadorizada/instrumentação , Procedimentos Endovasculares/instrumentação , Artéria Femoral/diagnóstico por imagem , Radiografia Intervencionista/instrumentação , Dispositivos de Acesso Vascular , Idoso , Pontos de Referência Anatômicos , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Cateterismo Periférico/efeitos adversos , Angiografia por Tomografia Computadorizada/efeitos adversos , Procedimentos Endovasculares/efeitos adversos , Desenho de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Punções , Radiografia Intervencionista/efeitos adversos , Estudos Retrospectivos , Resultado do Tratamento
8.
Ann Vasc Surg ; 60: 478.e19-478.e24, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31200042

RESUMO

BACKGROUND: We present a case with multiple visceral artery aneurysms that were treated with a hybrid approach involving both surgical and endovascular treatment. CASE REPORT: The patient was a 48-year-old female. She was diagnosed with multiple visceral artery aneurysms including 2 splenic artery aneurysms, celiac artery aneurysm, and bilateral renal artery aneurysms during an examination for loss of appetite. With regard to 2 splenic artery aneurysms, the proximal aneurysm was treated surgically, whereas the peripheral aneurysm that was located deeply in the abdomen was treated with coil embolization. The celiac artery aneurysm located at the bifurcation of the common hepatic artery and splenic artery, an intracranial aneurysm clip was used. The left and right renal aneurysms were resected and renal arteries were reconstructed surgically. The postoperative course was uneventful. The pathological diagnosis of all aneurysms was segmental arterial mediolysis. The reconstructed vessels were patent without stenosis or recurrence at 1 year after the operation. CONCLUSIONS: Hybrid treatment involving surgical resection, endovascular coil embolization, and obliteration with clips was useful in the treatment of multiple visceral artery aneurysms.


Assuntos
Aneurisma/terapia , Artérias/cirurgia , Embolização Terapêutica , Procedimentos Endovasculares , Procedimentos Cirúrgicos Vasculares , Vísceras/irrigação sanguínea , Aneurisma/diagnóstico por imagem , Aneurisma/fisiopatologia , Artérias/diagnóstico por imagem , Artérias/fisiopatologia , Embolização Terapêutica/instrumentação , Procedimentos Endovasculares/instrumentação , Feminino , Humanos , Pessoa de Meia-Idade , Resultado do Tratamento , Procedimentos Cirúrgicos Vasculares/instrumentação
9.
J Vasc Surg ; 70(1): 181-192, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-30583901

RESUMO

OBJECTIVE: We aimed to retrospectively analyze incidence, risk factors, and management of postoperative stent graft (SG) infection after endovascular aneurysm repair (EVAR). METHODS: We evaluated patients who underwent EVAR for infrarenal abdominal aortic aneurysm at our institution between July 2006 and December 2014. The primary end point was SG infection. We compared patients' demographics between the infection (group I) and noninfection (group NI) groups and reviewed management and outcomes in group I. A risk factor for SG infection was assessed by multivariable logistic regression. Patients without aortoenteric fistula (AEF) were treated with conservative therapy for SG infection. RESULTS: A total of 1202 patients underwent EVAR for infrarenal abdominal aortic aneurysm. During a mean follow-up of 43.9 ± 30.4 months, SG infection occurred in 15 cases (incidence, 3.5/1000 person-years). The median time between initial EVAR and detection of infection was 30 months (range, 14 days-86 months). Freedom from SG infection at 1 year, 3 years, and 5 years was 99.5%, 99.2%, and 98.2%, respectively. There were no differences in age, sex, comorbidities, and SG type between the groups. Coil embolization of the hypogastric artery was more frequent in group I (60% vs 31%). During follow-up before infection, type II endoleak (47% vs 24%), sac enlargement (40% vs 16%), and multiple reinterventions (13% vs 2%) were significantly higher in group I; however, after multivariate analysis, only coil embolization of the hypogastric artery (odds ratio, 3.22; 95% confidence interval, 1.12-9.24; P = .029) remained a significant predictor. Among the 15 patients, four had AEF and six bacteriologic species were detected in five patients (33%). Twelve patients (80%) were treated with conservative therapy; three underwent surgical therapy (two patients with SG resection, omentum patching, and extra-anatomic bypass with fistula closure or partial duodenectomy and one patient with graft preservation, irrigation, omentum patching, and aneurysmorrhaphy). In-hospital mortality occurred in three cases; two cases were due to sepsis after conservative therapy, and one case was due to aortic stump rupture after surgical therapy. Excluding in-hospital mortality cases, during a median follow-up of 31 (range, 2-76) months, five patients were lost because of cancer or senility. There was no aneurysm-related death or recurrence of SG infection. CONCLUSIONS: Concomitant coil embolization was a risk factor for SG infection. For patients with AEF, surgical therapy remains the first-line treatment of SG infection after EVAR; however, conservative therapy is a viable option for SG infection in patients without AEF, particularly considering patients' comorbidities and limited life expectancy.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/efeitos adversos , Prótese Vascular/efeitos adversos , Tratamento Conservador , Remoção de Dispositivo , Procedimentos Endovasculares/efeitos adversos , Infecções Relacionadas à Prótese/terapia , Stents/efeitos adversos , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Abdominal/mortalidade , Implante de Prótese Vascular/instrumentação , Implante de Prótese Vascular/mortalidade , Comorbidade , Tratamento Conservador/efeitos adversos , Tratamento Conservador/mortalidade , Remoção de Dispositivo/efeitos adversos , Remoção de Dispositivo/mortalidade , Embolização Terapêutica/efeitos adversos , Procedimentos Endovasculares/instrumentação , Procedimentos Endovasculares/mortalidade , Feminino , Mortalidade Hospitalar , Humanos , Incidência , Expectativa de Vida , Masculino , Infecções Relacionadas à Prótese/diagnóstico , Infecções Relacionadas à Prótese/microbiologia , Infecções Relacionadas à Prótese/mortalidade , Reoperação , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Tóquio/epidemiologia , Resultado do Tratamento
10.
Ann Vasc Surg ; 55: 196-202, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30287295

RESUMO

BACKGROUND: This study aimed to retrospectively demonstrate the growth rate (mm/year) of abdominal aortic aneurysm (AAA) diameters (ADs) and to analyze risk factors for AAA expansion. METHODS: We retrospectively investigated the clinical data of 319 patients with AAAs who were followed up as outpatients for >2 years after their initial visit and who underwent computed tomography >4 times. RESULTS: The mean follow-up period was 3.7 ± 1.5 years. The annual average growth rates according to varying ADs were as follows: 1.9 ± 0.8 (AD 30-34 mm), 2.6 ± 1.2 (AD 35-39 mm), 2.8 ± 1.1 (AD 40-44 mm), 3.1 ± 1.3 (AD 45-49 mm), 3.4 ± 1.6 (AD 50-54 mm), and 3.5 ± 1.4 mm (AD ≥55 mm). Factors associated with AAA expansion were smoking (P = 0.017), hypertension (P < 0.001), and ADs (P < 0.001). In the subgroup analysis, data regarding growth rates of ≥3 mm were extracted, and a statistically significant difference between smoking status and ADs of ≥40 mm was observed. CONCLUSIONS: Factors associated with AAA expansion in Japanese patients included smoking, hypertension, and ADs, and a statistically significant difference was observed between smoking status and ADs of ≥40 mm.


Assuntos
Aneurisma da Aorta Abdominal/etnologia , Povo Asiático , Idoso , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aortografia/métodos , Angiografia por Tomografia Computadorizada , Progressão da Doença , Feminino , Humanos , Hipertensão/etnologia , Japão/epidemiologia , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Retrospectivos , Fatores de Risco , Fumar/efeitos adversos , Fumar/etnologia , Fatores de Tempo
11.
Ann Vasc Surg ; 49: 123-133, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-29421415

RESUMO

BACKGROUND: To evaluate initial and midterm clinical outcomes of aortic aneurysms involving the proximal anastomotic aneurysm (AAPAAs) following initial open repair for infrarenal abdominal aortic aneurysm. METHODS: Between July 2006 and August 2015, 24 patients underwent elective endovascular repair for the treatment of AAPAAs at our institution. AAPAA classification has been categorized as 3 types. Type I AAPAA is the most extensive, extending from the descending aorta to the prior proximal anastomosis as similar to Crawford type II or III thoracoabdominal aortic aneurysm. Type II AAPAA is limited to the aortic aneurysm below the diaphragm including the abdominal visceral arteries. Finally, similar to pararenal abdominal aortic aneurysm, type III AAPAA involves the renal origins, but does not extend to the celiac and superior mesenteric arteries. Total endovascular aneurysm repair (t-EVAR) consisted of fenestrated EVAR (f-EVAR), multibranched EVAR (t-Branch), and snorkel EVAR (s-EVAR) were performed for patients with high-risk open surgical repair. We retrospectively analyzed 24 cases, which were categorized with 3 types of AAPAA. RESULTS: F-EVAR, t-Branch, and s-EVAR for AAPAAs were performed in 15 patients (62.5%), 5 patients (20.8%), and 4 patients (16.7%), respectively. Type I and type II AAPAA were identified in 13 patients (54.2%) and 7 patients (29.2%), and type III AAPAA was identified in 4 patients (16.7%). Technical success was 95.8%, and clinical success was 79.2% with t-EVAR. Spinal cord ischemia was identified in 2 patients (8.3%) of type I AAPAA, the 30-day mortality rate was 4.2% (n = 1, type I AAPAA). Type II and III endoleaks occurred in 1 (4.2%, type III AAPAA) and 3 patients (12.5%, each case of type I, II, and III AAPAA), respectively. There was no open conversion or aneurysm rupture in the late follow-up period. The estimated overall survival rates of t-EVAR after 1 and 3 years were 95.6% and 76.2%, respectively. Rates of freedom from aneurysm-related death and secondary intervention of t-EVAR at 3 years were 90.1% and 89.7%, respectively. Finally, rates of target vessel patency at 1 and 3 years were 95.3% and 88.8%, respectively. CONCLUSIONS: Our initial to midterm results of t-EVAR for the treatment of AAPAA were generally good with low rates of perioperative mortality and aneurysm-related death. However, more attentions should be paid for the treatment of type I AAPAA with high incidence of major adverse events.


Assuntos
Falso Aneurisma/cirurgia , Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular , Procedimentos Endovasculares , Idoso , Idoso de 80 Anos ou mais , Falso Aneurisma/diagnóstico por imagem , Falso Aneurisma/etiologia , Falso Aneurisma/mortalidade , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/mortalidade , Aortografia/métodos , Prótese Vascular , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Implante de Prótese Vascular/mortalidade , Angiografia por Tomografia Computadorizada , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Procedimentos Endovasculares/mortalidade , Feminino , Humanos , Masculino , Desenho de Prótese , Estudos Retrospectivos , Fatores de Risco , Stents , Fatores de Tempo , Tóquio , Resultado do Tratamento
12.
World J Surg ; 42(5): 1551-1558, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29167953

RESUMO

BACKGROUND: Bleeding from the thoracic aorta is potentially fatal in patients with advanced esophageal cancer. Thoracic endovascular aortic repair (TEVAR) was recently applied for aortic invasion by esophageal cancer. However, only a few case reports have been published. This study was performed to clarify the effectiveness and safety of TEVAR for patients with advanced esophageal cancer. METHODS: We retrospectively reviewed 18 patients who underwent TEVAR for esophageal cancer. We also performed a literature search and reviewed 21 similar cases. RESULTS: From 2007 to 2016, 10 patients were treated on an emergent basis for aortic hemorrhage (salvage group) and 8 patients underwent urgent prophylactic surgery (prophylactic group). Hemostasis was achieved in all cases. One (10%) patient in the salvage group died of aspiration pneumonia on postoperative day 1, while all patients in the prophylactic group survived for >1 month. The median survival period in the salvage and prophylactic group was 3.25 and 11.10 months, respectively. The longest survivor was still alive 9 years after TEVAR and chemoradiotherapy. No fatal adverse events or negative impacts on subsequent treatment for esophageal cancer occurred. CONCLUSIONS: TEVAR is feasible, safe, and effective in preventing fatal aortic hemorrhage secondary to esophageal cancer invasion, although it is palliative in most cases. Because the outcomes of emergent TEVAR after bleeding tended to be worse in the salvage than in prophylactic group, prophylactic TEVAR may be considered a viable treatment option for patients with aortic invasion by advanced esophageal cancer.


Assuntos
Aorta Torácica/cirurgia , Procedimentos Endovasculares , Neoplasias Esofágicas/patologia , Hemorragia/cirurgia , Idoso , Idoso de 80 Anos ou mais , Aorta Torácica/patologia , Procedimentos Endovasculares/mortalidade , Feminino , Hemorragia/etiologia , Hemostasia Cirúrgica , Humanos , Masculino , Pessoa de Meia-Idade , Invasividade Neoplásica , Estudos Retrospectivos , Terapia de Salvação , Stents
13.
J Vasc Surg ; 67(2): 490-497, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-28943006

RESUMO

OBJECTIVE: We developed a mini-incision eversion carotid endarterectomy (CEA) procedure (the Jikei method CEA) to prevent perioperative embolic stroke. The aim of this study was to retrospectively analyze perioperative and midterm outcomes after the Jikei method CEA. METHODS: We evaluated patients with the Jikei method CEA at our institution between January 2006 and June 2014. The primary end point was a major adverse event, which included death, stroke, intracranial hemorrhage, and myocardial infarction, within 30 days of CEA. Secondary end points were postoperative ipsilateral stroke and restenosis. RESULTS: We retrospectively studied 120 lesions in 110 patients. The mean age was 72.2 ± 8.0 years. With regard to the 120 lesions, 56 lesions (46.7%) were symptomatic and 73 lesions (60.8%) showed ≥90% severe stenosis. The mean length of the skin incision was 3.2 ± 0.5 cm. The mean operative time, volume of blood loss, and internal carotid artery clamp time were 171.0 ± 50.7 minutes, 161.6 ± 110.8 mL, and 35.7 ± 10.8 minutes, respectively. There were three perioperative major adverse events (2.5%), including two strokes (1.7%) and one intracranial hemorrhage (0.8%) resulting from hyperperfusion syndrome. The median postoperative hospital stay was 6 days (range, 2-303 days). The mean follow-up was 3.9 ± 2.2 years. There was no case of ipsilateral stroke during the follow-up period. The freedom from ipsilateral stroke at 5 years was 98.3%. Three lesions (2.5%) developed restenosis. The freedom from restenosis was 97.2% at 5 years. The freedom from reintervention at 5 years was 99.0% because carotid artery stent placement was necessary in one patient with severe restenosis. CONCLUSIONS: The Jikei method CEA was safe and effective in preventing perioperative and midterm stroke.


Assuntos
Artéria Carótida Interna/cirurgia , Estenose das Carótidas/cirurgia , Endarterectomia das Carótidas/métodos , Idoso , Idoso de 80 Anos ou mais , Angiografia , Artéria Carótida Interna/diagnóstico por imagem , Estenose das Carótidas/complicações , Estenose das Carótidas/diagnóstico por imagem , Estenose das Carótidas/mortalidade , Intervalo Livre de Doença , Endarterectomia das Carótidas/efeitos adversos , Endarterectomia das Carótidas/mortalidade , Feminino , Humanos , Embolia Intracraniana/etiologia , Embolia Intracraniana/prevenção & controle , Hemorragias Intracranianas/etiologia , Estimativa de Kaplan-Meier , Tempo de Internação , Masculino , Pessoa de Meia-Idade , Recidiva , Estudos Retrospectivos , Fatores de Risco , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Fatores de Tempo , Tóquio , Resultado do Tratamento
14.
Ann Vasc Surg ; 45: 265.e13-265.e16, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-28688876

RESUMO

Snorkel endovascular aortic repair (SEVAR) is reported to be effective for the treatment of pararenal or juxtarenal aortic aneurysms. SEVAR can be performed with an off-the-self device, which is applied for emergency cases. However, there is a concern that SEVAR lead to gutter leak due to insertion of multiple stents. Previously, we performed 2-staged treatment for gutter leak after SEVAR. However, the gutter leaks can also occur late, and it is often difficult to close. Therefore, if a significant gutter leak is identified intraoperatively, performing concomitant gutter coil embolization at the time of the initial surgery may be reasonable.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/métodos , Embolização Terapêutica , Endoleak/terapia , Procedimentos Endovasculares/métodos , Idoso de 80 Anos ou mais , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aortografia/métodos , Prótese Vascular , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Angiografia por Tomografia Computadorizada , Endoleak/diagnóstico por imagem , Endoleak/etiologia , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Stents , Resultado do Tratamento
15.
Ann Vasc Surg ; 44: 146-157, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-28483620

RESUMO

BACKGROUND: In this single-center study, we assessed the clinical outcomes of fenestrated endovascular aortic repair (f-EVAR) and branched EVAR on morbidity and mortality during total endovascular aortic repair for thoracoabdominal aortic aneurysms (TAAAs). METHODS: Between July 2006 and June 2015, elective f-EVAR and multibranched EVAR (t-Branch) for TAAAs were performed in 99 patients at our institution (Crawford classification types I [7], II [13], III [6], IV [55], and V [18]). We retrospectively analyzed 44 patients, excluding those with Crawford type IV TAAAs, and compared 30 patients treated with f-EVAR and 14 treated with t-Branch. Multivariate analysis was performed to determine the factors associated with perioperative spinal cord ischemia (SCI). RESULTS: Technical success was 96.7% with f-EVAR and 100% with t-Branch, and the 30-day mortality rate was 3.3% with f-EVAR and 7.1% with t-Branch (P = 0.646). The incidences of perioperative SCI were higher with t-Branch (n = 5, 35.7%) than those with f-EVAR (n = 2, 6.7%; P = 0.04). Endoleaks were more prevalent with f-EVAR (n = 9, 30.0%) than with t-Branch (n = 1, 7.1%; P = 0.046). Rates of freedom from aneurysm-related death after 1 year for f-EVAR and t-Branch were 96.7 and 92.9%, respectively, and those after 3 years were 88.8 and 92.9% (P = 0.982), respectively. The risk of SCI remarkably increased in the presence of risk factors such as procedure (t-Branch), maximum short axis of ≥65 mm, coverage length of ≥360 mm, internal iliac artery occlusion, and ≥ 5 sacrificed intercostal arteries. CONCLUSIONS: Our initial to mid-term results of f-EVAR and t-Branch were good with low rates of perioperative mortality and high rates of freedom from aneurysm-related death. SCI incidence with t-Branch was significantly high; it is important to develop additional SCI prevention methods for patients with high-risk factors.


Assuntos
Aneurisma da Aorta Torácica/cirurgia , Implante de Prótese Vascular , Prótese Vascular , Procedimentos Endovasculares , Isquemia do Cordão Espinal/etiologia , Stents , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/mortalidade , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Implante de Prótese Vascular/mortalidade , Distribuição de Qui-Quadrado , Endoleak/etiologia , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Procedimentos Endovasculares/mortalidade , Feminino , Humanos , Estimativa de Kaplan-Meier , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Desenho de Prótese , Estudos Retrospectivos , Fatores de Risco , Isquemia do Cordão Espinal/diagnóstico por imagem , Isquemia do Cordão Espinal/mortalidade , Fatores de Tempo , Tóquio , Resultado do Tratamento
16.
J Vasc Surg ; 66(1): 130-142.e1, 2017 07.
Artigo em Inglês | MEDLINE | ID: mdl-28400218

RESUMO

OBJECTIVE: The objective of this study was to assess 1-year safety, efficacy, and invasiveness outcomes of endovascular stent grafting of symptomatic long lesions (≥10 cm) in the superficial femoral artery (SFA) as a substitute for above-knee open bypass surgery. METHODS: This prospective, multicenter (15 hospitals) study assessed heparin-coated stent grafts for the treatment of long SFA lesions in Japanese subjects with peripheral arterial disease. Inclusion criteria were Rutherford category 2 to 5 symptoms (grade 5 without active infection), ankle-brachial index ≤0.9, and color flow duplex ultrasound-assessed SFA lesions with cumulative length ≥10 cm and ≥50% stenosis. Main efficacy and safety outcomes were primary assisted patency and adverse events, respectively. Secondary outcomes included primary patency using the surgical bypass definition, that is, blood flow through a device without requiring target lesion revascularization (TLR) to maintain or to restore flow. For comparison with prior endovascular studies, primary patency-interventional was defined as peak systolic velocity ratio <2.5 without TLR in treated lesions. Other outcomes included freedom from TLR and Vascular Quality of Life questionnaire scoring. General anesthesia avoidance and hospitalization duration were compared with historical data from 68 consecutive patients (n = 51 Rutherford 2/3 claudicants and 17 Rutherford 4/5 subjects) who underwent above-knee bypass surgery at study sites between 2002 and 2012 and met study enrollment criteria. RESULTS: Of 103 enrollees (74.2 ± 7.0 years old; 17.5% female; 97.1% claudicants), 100 subjects were evaluated through postoperative 12 months. Average lesion length was 21.8 ± 5.8 cm, and 65.7% were totally occluded. The whole-cohort Kaplan-Meier estimated primary assisted patency rate was 94.1% (95% confidence interval [CI], 87.3%-97.3%) at 12 months. The primary patency-surgical rate was 92.1% (95% CI, 84.8%-96.0%), the primary patency-interventional rate was 88.1% (95% CI, 80.0%-93.1%), and freedom from TLR was 93.1% (95% CI, 86.1%-96.7%). Mean ankle-brachial index increased from 0.64 ± 0.12 to 0.98 ± 0.12 at 1 month after intervention and 0.94 ± 0 .17 at 12 months (P < .0001 at both follow-ups). Target vessel revascularization, major amputation, or death did not occur through postoperative 30 days. No life- or limb-threatening intraoperative or perioperative adverse events and no acute limb ischemia cases were observed during follow-up. Vascular Quality of Life questionnaire score increased from 58.6% ± 15.7% to 72.9% ± 18.6% at 12 months (P < .0001). No stent fractures were detected. No stent graft participant required general anesthesia, and median postoperative hospital stay was 2.0 days (mean, 3.4 ± 2.9 days) in the Viabahn (W. L. Gore & Associates, Flagstaff, Ariz) claudicant subgroup, values that were significantly lower than the 76.5% general anesthesia rate (P < .0001) and 11.0 days median hospitalization stay (mean, 12.7 ± 5.3 days; P < .0001) in the 51 open bypass claudicant subjects. CONCLUSIONS: Stent grafting appears to be a safe and less invasive alternative to above-knee bypass surgery, providing 88% to 92% primary patency at 12 months in long, complex lesions.


Assuntos
Implante de Prótese Vascular/instrumentação , Prótese Vascular , Procedimentos Endovasculares/instrumentação , Artéria Femoral/cirurgia , Claudicação Intermitente/cirurgia , Doença Arterial Periférica/cirurgia , Stents , Idoso , Idoso de 80 Anos ou mais , Índice Tornozelo-Braço , Implante de Prótese Vascular/efeitos adversos , Intervalo Livre de Doença , Procedimentos Endovasculares/efeitos adversos , Feminino , Artéria Femoral/diagnóstico por imagem , Artéria Femoral/fisiopatologia , Humanos , Claudicação Intermitente/diagnóstico por imagem , Claudicação Intermitente/fisiopatologia , Japão , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Doença Arterial Periférica/diagnóstico por imagem , Doença Arterial Periférica/fisiopatologia , Estudos Prospectivos , Desenho de Prótese , Qualidade de Vida , Fluxo Sanguíneo Regional , Fatores de Risco , Inquéritos e Questionários , Fatores de Tempo , Resultado do Tratamento , Ultrassonografia Doppler em Cores , Grau de Desobstrução Vascular
17.
Surg Today ; 47(11): 1384-1390, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-28389694

RESUMO

PURPOSE: To evaluate the efficiency of using the Ginza forceps (DVx, Tokyo, Japan), which have a long shaft and strong grip, for superficial phlebectomy with the stab avulsion technique, during simultaneous endovenous laser ablation (EVLA) of the great saphenous vein (GSV). METHODS: The subjects were patients treated with EVLA performed by a single operator at one institution. All patients had a GSV diameter of 4-10 mm and an EVLA length of the GSV of >20 cm. We compared 59 limbs treated only with the Varady hook (Group A) with 46 limbs treated with the Ginza forceps (Group G). RESULTS: The mean operative times for Groups A and G were 55.4 ± 17.1 vs. 48.5 ± 13.5 min, respectively (P = 0.002), and the number of stab incisions was 5.9 ± 2.9 (1-13) vs. 3.5 ± 2.3 (1-11), respectively (P < 0.001). The rates of nerve injury and thrombophlebitis were 1.7 vs. 0 and 3.4 vs. 0%, respectively. CONCLUSIONS: Performing superficial phlebectomy with the Ginza forceps reduced the operation time and the number of stab wounds. These initial results suggest that using the Ginza forceps for the procedure is safe and efficient.


Assuntos
Procedimentos Endovasculares/instrumentação , Procedimentos Endovasculares/métodos , Terapia a Laser/instrumentação , Terapia a Laser/métodos , Flebotomia/instrumentação , Flebotomia/métodos , Veia Safena/cirurgia , Instrumentos Cirúrgicos , Idoso , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Duração da Cirurgia , Cuidados Pós-Operatórios , Meias de Compressão , Resultado do Tratamento
18.
Ann Vasc Surg ; 41: 96-104, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-28238929

RESUMO

BACKGROUND: To evaluate the optimal treatment for juxtarenal abdominal aortic aneurysm (JAAA), we compared the outcomes of open surgical repair (OSR) with endovascular aortic repair (EVAR) using a variety of fenestrated and snorkel EVARs. METHODS: We evaluated overall survival, aneurysm-related death, reintervention, and renal impairment in 152 JAAAs retrospectively, excluding cases of aortic dissection and rupture. Cox models were used to assess survival and assessed postoperative dialysis rates following surgery. RESULTS: OSR and EVAR were performed in 81 and 71 patients, respectively. The mean age was significantly higher in the EVAR group (overall, 74.5 years; OSR, 71 years; and EVAR; 77 years). High preoperative serum creatinine levels, cerebrovascular disease, and chronic obstructive pulmonary disease were more prevalent in the EVAR group. Mean operative time, hospital stay, and perioperative blood loss were significantly greater in the OSR group (P < 0.001 for all). The overall 30-day mortality was 1.9% with no statistical difference between 2 groups. The reintervention rate was significantly higher in the EVAR group (P = 0.01). Overall survival rates at 1, 3, 5, and 7 years were 97.4%, 91.6%, 86.3%, and 82.9%, respectively, with no significant difference between groups. Mortality in EVAR was associated with over 3.0 mg/dL of postoperative creatinine, and postoperative dialysis following OSR was associated with operative time and volume of bleeding. CONCLUSIONS: Acceptable outcomes were observed with OSR and EVAR. However, reintervention was more frequently required following EVAR. OSR appears to be the most appropriate first-line treatment for JAAA in good-risk patients; however, EVAR may represent an alternative option in high-risk patients.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular , Procedimentos Endovasculares , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/mortalidade , Prótese Vascular , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Implante de Prótese Vascular/mortalidade , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Procedimentos Endovasculares/mortalidade , Feminino , Humanos , Estimativa de Kaplan-Meier , Tempo de Internação , Masculino , Pessoa de Meia-Idade , Duração da Cirurgia , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/mortalidade , Desenho de Prótese , Estudos Retrospectivos , Fatores de Risco , Stents , Fatores de Tempo , Tóquio , Resultado do Tratamento
19.
Medicine (Baltimore) ; 95(46): e5430, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27861387

RESUMO

BACKGROUND: Hereditary hemorrhagic telangiectasia (HHT) is characterized by mucocutaneous telangiectasia and visceral vascular malformations (VMs). Liver involvement with VMs may lead to high-output cardiac failure, portal hypertension, and biliary disease. There is no curative treatment for the disease, and liver transplantation is indicated for life-threatening complications. Herein, we report a case of multiple hepatic artery aneurysms (HAAs) in a patient with HHT in which open arterial reconstruction was performed. There have only been a few case reports on HAA occurring with HHT. Thus, this case provides important information for the management of HHT-associated HAAs. CASE SUMMARY: A 62-year-old female with known HHT was referred to our facility to seek further treatment for a giant HAA. She denied any symptoms except recurrent epistaxis. A computed tomography (CT) scan revealed a right HAA with a diameter of 72 mm, in addition to 2 other minor HAAs. The CT scan also revealed the VMs that were scattered in the liver, and a continuously dilated and tortuous artery existing from the celiac trunk to the right and left hepatic arteries. We performed open arterial reconstruction of the HAAs. Her postoperative course was uneventful. CONCLUSIONS: When treating HAAs, there are a variety of options. However, hepatic VMs might affect HHT patients in various ways postprocedurally. Ligation and embolization of the hepatic artery may lead to complications, such as massive hepatic necrosis. Hepatectomy should be avoided if possible, because a postoperative hyperperfusive state in the remaining liver can cause adverse events. We believe that arterial reconstruction of HHT-associated HAAs might reduce the risk of postprocedural complications with minimal hemodynamic changes in the liver, thus obviating the need for hepatectomy or liver transplantation.


Assuntos
Aneurisma , Angiografia/métodos , Artéria Hepática , Telangiectasia Hemorrágica Hereditária , Procedimentos Cirúrgicos Vasculares/métodos , Aneurisma/diagnóstico , Aneurisma/etiologia , Aneurisma/cirurgia , Feminino , Artéria Hepática/anormalidades , Artéria Hepática/diagnóstico por imagem , Artéria Hepática/cirurgia , Humanos , Fígado/irrigação sanguínea , Fígado/diagnóstico por imagem , Pessoa de Meia-Idade , Procedimentos de Cirurgia Plástica/métodos , Telangiectasia Hemorrágica Hereditária/complicações , Telangiectasia Hemorrágica Hereditária/fisiopatologia , Tomografia Computadorizada por Raios X/métodos , Resultado do Tratamento
20.
Medicine (Baltimore) ; 95(15): e3335, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-27082585

RESUMO

The aim of the study is to identify the potential risk factors of cerebral infarction associated with thoracic endovascular aneurysm repair (TEVAR). TEVAR was developed as a less invasive surgical alternative to conventional open repair for thoracic aortic aneurysm treatment. However, outcomes following TEVAR of aortic and distal arch aneurysms remain suboptimal. Cerebral infarction is a major concern during the perioperative period. We included 439 patients who underwent TEVAR of aortic aneurysms at a high-volume teaching hospital between July 2006 and June 2013. Univariate and multivariate logistic regression analyses were performed to identify perioperative cerebral infarction risk factors. Four patients (0.9%) died within 30 days of TEVAR; 17 (3.9%) developed cerebral infarction. In univariate analysis, history of ischemic heart disease and cerebral infarction and concomitant cerebrovascular disease were significantly associated with cerebral infarction. "Shaggy aorta" presence, left subclavian artery coverage, carotid artery debranching, and pull-through wire use were identified as independent risk factors of cerebral infarction. In multivariate analysis, history of ischemic heart disease (odds ratio [OR] 6.49, P = 0.046) and cerebral infarction (OR 43.74, P = 0.031), "shaggy aorta" (OR 30.32, P < 0.001), pull-through wire use during surgery (OR 7.196, P = 0.014), and intraoperative blood loss ≥800 mL (OR 24.31, P = 0.017) were found to be independent risk factors of cerebral infarction. This study identified patient- and procedure-related risk factors of cerebral infarction following TEVAR. These results indicate that patient outcomes could be improved through the identification and management of procedure-related risk factors.


Assuntos
Aneurisma da Aorta Torácica/cirurgia , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/métodos , Infarto Cerebral/etiologia , Idoso , Comorbidade , Feminino , Humanos , Masculino , Análise Multivariada , Razão de Chances , Estudos Retrospectivos , Fatores de Risco , Fatores Sexuais
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA