Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
J Cardiovasc Electrophysiol ; 35(3): 601-607, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38287171

RESUMO

The subcutaneous implantable cardioverter defibrillator (S-ICD) was developed as an alternative to the traditional transvenous implantable cardioverter defibrillator (TV-ICD), aiming to provide easier implantation, simplified detection algorithm of malignant ventricular arrhythmias and prevention from placing components in the cardiovascular system. The S-ICD is implanted subcutaneously or intramuscularly with the generator placed in the left midaxillary line and the lead tunneled subcutaneously in the left para-sternal region. Preimplant electrocardiogram screening is recommended to prevent implantation in patients at high risk of T wave over-sensing. Currently, the S-ICD is unsuitable for patients requiring pacing or cardiac resynchronization. Since the beginning, the S-ICD underwent extensive preclinical investigation until the first prospective multicentre trial demonstrating high efficacy and safety led to market release. While earlier studies focused on younger patients with higher ejection fraction, more recent studies showed favorable outcomes even in patients with comorbidities similar to those typically observed in patients receiving TV-ICD. The development of second and third generation devices has contributed to reduce inappropriate shocks and overcome previous limitations. The aim of this paper is to review the evidence in the literature over the past decade supporting S-ICD as a valid alternative to TV-ICD in terms of safety and efficacy, highlighting the improvements in technology, as well as outcomes.


Assuntos
Morte Súbita Cardíaca , Desfibriladores Implantáveis , Humanos , Morte Súbita Cardíaca/prevenção & controle , Estudos Prospectivos , Resultado do Tratamento , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/terapia , Arritmias Cardíacas/etiologia , Desfibriladores Implantáveis/efeitos adversos , Estudos Multicêntricos como Assunto
2.
Nutrients ; 15(4)2023 Feb 14.
Artigo em Inglês | MEDLINE | ID: mdl-36839298

RESUMO

Background. Overweight and obesity are associated with atrial fibrillation (AF), and bariatric surgery (BS), able to induce sustained and prolonged weight loss, might represent the ideal treatment in the prevention of AF. Previous studies could not definitely establish a role for weight loss and BS in preventing incident AF so far. During the last few years, several studies on the effect of bariatric surgery on cardiovascular diseases have been published, and we performed a systematic review and meta-analysis to evaluate the role of weight loss through BS in the prevention of incident AF in obesity. Methods. This meta-analysis followed the PRISMA guideline. Eligible studies were controlled trials evaluating the appearance of atrial fibrillation in patients undergoing weight loss through BS as compared with patients receiving medical treatment. Quality of studies was assessed according to the Newcastle-Ottawa Quality Assessment Scale, and risk-of-bias was evaluated employing the Egger's test. All analyses were run by a random-effects model according to Hartung and Knapp and sensitivity analyses were performed. Heterogeneity was assessed through Q and I2 statistics for each comparison, and potential publication bias was formally investigated. Results. Ten studies were included in the meta-analysis, and the overall result was statistically significant [OR = 0.665 (0.475-0.929), p = 0.017], with significant heterogeneity (Q = 48.98, p < 0.001; I2 = 81.6%), but with no publication bias. In sensitivity analyses, the amount of weight loss, percentage of patients with diabetes and value of the Newcastle-Ottawa Quality Assessment Scale, were all associated with significance of effect. Since age was different in one study, a sensitivity analysis was performed by excluding this study; OR was similar [OR = 0.608 (0.454-0.814), p < 0.001]; heterogeneity was reduced but still significant (Q = 35.74, p < 0.001, I2 = 77.6%) and again no publication bias was detected. Conclusions. Bariatric surgery as compared to medical treatment is associated with reduced appearance of incident AF.


Assuntos
Fibrilação Atrial , Cirurgia Bariátrica , Humanos , Fibrilação Atrial/complicações , Obesidade , Redução de Peso , Cirurgia Bariátrica/métodos , Sobrepeso/complicações
3.
Circulation ; 143(14): 1359-1373, 2021 04 06.
Artigo em Inglês | MEDLINE | ID: mdl-33401956

RESUMO

BACKGROUND: Left ventricular (LV) scar on late gadolinium enhancement (LGE) cardiac magnetic resonance has been correlated with life-threatening arrhythmic events in patients with apparently idiopathic ventricular arrhythmias (VAs). We investigated the prognostic significance of a specific LV-LGE phenotype characterized by a ringlike pattern of fibrosis. METHODS: A total of 686 patients with apparently idiopathic nonsustained VA underwent contrast-enhanced cardiac magnetic resonance. A ringlike pattern of LV scar was defined as LV subepicardial/midmyocardial LGE involving at least 3 contiguous segments in the same short-axis slice. The end point of the study was time to the composite outcome of all-cause death, resuscitated cardiac arrest because of ventricular fibrillation or hemodynamically unstable ventricular tachycardia and appropriate implantable cardioverter defibrillator therapy. RESULTS: A total of 28 patients (4%) had a ringlike pattern of scar (group A), 78 (11%) had a non-ringlike pattern (group B), and 580 (85%) had normal cardiac magnetic resonance with no LGE (group C). Group A patients were younger compared with groups B and C (median age, 40 vs 52 vs 45 years; P<0.01), more frequently men (96% vs 82% vs 55%; P<0.01), with a higher prevalence of family history of sudden cardiac death or cardiomyopathy (39% vs 14% vs 6%; P<0.01) and more frequent history of unexplained syncope (18% vs 9% vs 3%; P<0.01). All patients in group A showed VA with a right bundle-branch block morphology versus 69% in group B and 21% in group C (P<0.01). Multifocal VAs were observed in 46% of group A patients compared with 26% of group B and 4% of group C (P<0.01). After a median follow-up of 61 months (range, 34-84 months), the composite outcome occurred in 14 patients (50.0%) in group A versus 15 (19.0%) in group B and 2 (0.3%) in group C (P<0.01). After multivariable adjustment, the presence of LGE with ringlike pattern remained independently associated with increased risk of the composite end point (hazard ratio, 68.98 [95% CI, 14.67-324.39], P<0.01). CONCLUSIONS: In patients with apparently idiopathic nonsustained VA, nonischemic LV scar with a ringlike pattern is associated with malignant arrhythmic events.


Assuntos
Arritmias Cardíacas/diagnóstico , Ventrículos do Coração/fisiopatologia , Adulto , Arritmias Cardíacas/mortalidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Estudos Retrospectivos , Análise de Sobrevida
4.
Europace ; 18(2): 288-93, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26333380

RESUMO

AIMS: Malfunctions of cardiac implantable electronical devices (CIED) have been described after high-energy radiation therapy even in the absence of direct exposure to ionizing radiation, due to diffusion of neutrons (n) causing soft errors in inner circuits. The purpose of the study was to analyse the effect of scattered radiation on different types and models of CIED and the possible sources of malfunctions. METHODS AND RESULTS: Fifty-nine explanted CIED were placed on an anthropomorphous phantom of tissue-equivalent material, and a high-energy photon (15 MV) radiotherapy course (total dose = 70 Gy) for prostate treatment was performed. All devices were interrogated before and after radiation. Radiation dose, the electromagnetic field, and neutron fluence at the CIED site were measured. Thirty-four pacemakers (PM) and 25 implantable cardioverter-defibrillators (ICD) were analysed. No malfunctions were detected before radiation. After radiation a software malfunction was evident in 13 (52%) ICD and 6 (18%) PM; no significant electromagnetic field or photon radiations were detected in the thoracic region. Neutron capture was demonstrated by the presence of the (198)Au((197)Au + n) or (192)Ir((191)Ir + n) isotope activation; it was significantly greater in ICD than in PM and non-significantly greater in damaged devices. A greater effect in St Jude PM (2/2 damaged), Boston (9/11), and St Jude ICD (3/6) and in older ICD models was observed; the year of production was not relevant in PM. CONCLUSION: High-energy radiation can cause different malfunctions on CIED, particularly ICD, even without direct exposure to ionizing radiation due to scattered radiation of neutrons produced by the linear accelerator.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Radioterapia/efeitos adversos , Análise de Falha de Equipamento , Humanos , Teste de Materiais , Nêutrons , Desenho de Prótese , Falha de Prótese , Dosagem Radioterapêutica , Espalhamento de Radiação , Design de Software
5.
Am J Cardiol ; 109(5): 729-35, 2012 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-22176998

RESUMO

To assess the proportion and long-term outcomes of patients with idiopathic dilated cardiomyopathy and potential indications for implantable cardioverter-defibrillator before and after optimization of medical treatment, 503 consecutive patients with idiopathic dilated cardiomyopathy were evaluated from 1988 to 2006. A total of 245 patients (49%) satisfied the "Sudden Cardiac Death in Heart Failure Trial (SCD-HeFT) criteria," defined as a left ventricular ejection fraction of ≤0.35 and New York Heart Association (NYHA) class II-III on registration. Among these, 162 (group A) were re-evaluated 5.4 ± 2 months later with concurrent ß-blockers and angiotensin-converting enzyme inhibitor use. Of the 162 patients, 50 (31%) still had "SCD-HeFT criteria" (group A1), 109 (67%) had an improved left ventricular ejection fraction and/or New York Heart Association class (group A2), and 3 (2%) were in NYHA class IV. Of the 227 patients without baseline "SCD-HeFT criteria" (left ventricular ejection fraction >0.35 or NYHA class I), 125 were evaluated after 5.5 ± 2 months. Of these 227 patients, 13 (10%) developed "SCD-HeFT criteria" (group B1), 111 (89%) remained without "SCD-HeFT criteria" (group B2), and 1 (1%) had worsened to NYHA class IV. The 10-year mortality/heart transplantation and sudden death/sustained ventricular arrhythmia rate was 57% and 37% in group A1, 23% and 20% in group A2 (p <0.001 for mortality/heart transplantation and p = 0.014 for sudden death/sustained ventricular arrhythmia vs group A1), 45% and 41% in group B1 (p = NS vs group A1), 16% and 14% in group B2 (p = NS vs group A2), respectively. In conclusion, two thirds of patients with idiopathic dilated cardiomyopathy and "SCD-HeFT criteria" at presentation did not maintain implantable cardioverter-defibrillator indications 3 to 9 months later with optimal medical therapy. Their long-term outcome was excellent, similar to that observed for patients who had never met the "SCD-HeFT criteria."


Assuntos
Antagonistas Adrenérgicos beta/uso terapêutico , Inibidores da Enzima Conversora de Angiotensina/uso terapêutico , Cardiomiopatia Dilatada/terapia , Desfibriladores Implantáveis/estatística & dados numéricos , Procedimentos Desnecessários/estatística & dados numéricos , Antagonistas Adrenérgicos beta/administração & dosagem , Adulto , Inibidores da Enzima Conversora de Angiotensina/administração & dosagem , Cardiomiopatia Dilatada/diagnóstico , Cardiomiopatia Dilatada/mortalidade , Relação Dose-Resposta a Droga , Eletrocardiografia Ambulatorial , Feminino , Seguimentos , Humanos , Itália/epidemiologia , Masculino , Estudos Retrospectivos , Fatores de Risco , Taxa de Sobrevida/tendências , Fatores de Tempo , Resultado do Tratamento
6.
J Antimicrob Chemother ; 66(1): 192-200, 2011 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-21037251

RESUMO

BACKGROUND: the darunavir genotypic inhibitory quotient (gIQ) has been suggested as one of the predictors of virological response to darunavir-containing salvage regimens. Nevertheless, which resistance algorithm should be used to optimize the calculation of gIQ is still debated. The aim of our study was to compare seven different free-access resistance algorithms and their derived gIQs as predictors of 48 week virological response to darunavir-based salvage therapy in the clinical setting. METHODS: patients placed on two nucleoside reverse transcriptase inhibitors + 600/100 mg of darunavir/ritonavir twice daily  ±â€Š enfuvirtide were prospectively evaluated. Virological response was assessed at 48 weeks. Darunavir resistance interpretation was performed according to seven different algorithms, of which two were weighted algorithms. Analysis of other factors potentially associated with virological response at 48 weeks was performed. RESULTS: fifty-six treatment-experienced patients were included. Overall, 35 patients (62.5%) had a virological response at 48 weeks. Receiver operator characteristic curve analysis showed that De Meyer's weighted score (WS) and its derived gIQ (gIQ WS) were the most accurate parameters defining virological response, and related cut-offs showed the best sensitivity/specificity pattern. In univariate logistic regression analysis, baseline log viral load (P = 0.028), optimized background score ≥ 2 (P = 0.048), WS >5 (P = 0.001) and WS gIQ ≥ 600 (P < 0.0001) were independently associated with virological response. In multivariate analysis, only baseline log viral load (P = 0.008) and WS gIQ ≥ 600 (P < 0.0001) remained in the model. CONCLUSIONS: in our study, although different resistance interpretation algorithms and derived gIQs were associated with virological response, gIQ WS was the most accurate predictive model for achieving a successful virological response.


Assuntos
Algoritmos , Fármacos Anti-HIV/administração & dosagem , Farmacorresistência Viral , Infecções por HIV/tratamento farmacológico , HIV/efeitos dos fármacos , Terapia de Salvação/métodos , Sulfonamidas/administração & dosagem , Adulto , Fármacos Anti-HIV/farmacologia , Darunavir , Feminino , Genótipo , HIV/genética , Infecções por HIV/virologia , Humanos , Masculino , Testes de Sensibilidade Microbiana/métodos , Prognóstico , Estudos Retrospectivos , Sulfonamidas/farmacologia , Resultado do Tratamento , Carga Viral
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA